Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of AC (120/220V) 16A Power Supply (Cat. No. 1771-P7 Series B) Installation Instructions

Manual · Allen-Bradley

AC (120/220V) 16A Power Supply (Cat. No. 1771-P7 Series B) Installation Instructions

Manual8 pagesPDF 339 KB

Installation instructions for the Allen-Bradley 1771-P7 16A power supply and its 1771-CP1, -CP2 and -CP3 power cables.

Download the PDF339 KB

Covers · 2 models

The models it covers

Summary

What is in it

Allen-Bradley installation instructions for the 1771-P7 Series B AC (120/220V) 16A power supply, an external supply for one 1771 I/O chassis. They cover preparing for installation, setting the chassis configuration jumper, choosing the 1771-CP1, -CP2 or -CP3 power cable, mounting the supply on the side of the chassis or separately, connecting AC power and ground, troubleshooting with the P/S ACTIVE LED, and the specifications and power rating graphs.

Its parts

  1. To the Installer
  2. Prepare for Installation
  3. Install the 1771-P7 and Connect Backplane Power
  4. Connect ac Power Source to the Power Supply
  5. Troubleshooting
  6. Specifications
  7. Power Ratings

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Allen-Bradley installation instructions (publication 1771-2.93, March 1994) for the 1771-P7 Series B AC (120/220V) 16A power supply. They show how to mount it on the side of a 1771 I/O chassis or separately, which 1771-CP1, 1771-CP2 or 1771-CP3 power cable to use, how to wire ac power and how to read its status LED.

What it is
1771-P7: Series B AC (120/220V) 16A external power supply for a 1771 I/O chassis p. 1, 2
1771-CP1 cable
1771-CP1: 0.32m (1.04ft) cable for a 1771-P7 mounted on the left side of a panel-mounted I/O chassis p. 2, 8
Chassis
1771-P7: powers one 1771-A1B, -A2B, -A3B, -A3B1 or -A4B I/O chassis p. 1
Output
1771-P7: 16A max at 5V dc to the chassis backplane p. 8
Input voltage
1771-P7: 120V ac or 220V ac nominal; switch at 115 for 97 to 132V ac, at 230 for 195 to 264V ac p. 6
Processors
1771-P7: for adapters or processors without an internal supply, such as Mini-PLC-2/02, /05, /16, /17 or PLC-5 family p. 1
Other cables
1771-CP2: within 1.52m (5ft); 1771-CP3 (right angle connector): within 1.68m (5.5ft) p. 2
Fuse
1771-P7: 3A, 250V 3AG normal blow (Bussmann AGC 3, Littelfuse 312003) on line L1 p. 7, 8
Chassis jumper
1771-P7: set the I/O chassis power supply configuration jumper to N p. 2
Backplane connector
1771-P7: D-shell connector carries power to the I/O chassis backplane p. 2
Size and weight
1771-P7: 315mm x 115mm x 159mm (12.40" x 4.53" x 6.25"), 1.95kg (4.3 lbs.) p. 8
Line frequency
1771-P7: 47-63Hz p. 8
Status LED
1771-P7: green P/S ACTIVE LED, on in normal operation p. 7

What this manual walks you through

  • Preparing the I/O chassis and setting its configuration jumper p. 2
  • Attaching the supply to the left side of a panel-mounted I/O chassis p. 3, 4
  • Mounting the supply separately and running the power cable p. 5, 6
  • Setting the input voltage switch and wiring ac power p. 6, 7
  • Troubleshooting with the P/S ACTIVE LED p. 7
  • Sizing a transformer and estimating cooling and power cost p. 8

Good to know

  • The 1771-P7 is a stand-alone supply and must not be connected in parallel with another power supply. p. 1
  • The 1771-P7 is not compatible with the 1771-A1, -A2 or -A4 I/O chassis. p. 1
  • A separately mounted supply goes above or next to the chassis, never below, with at least 6 inches of vertical distance. p. 5
  • A 14 AWG wire must run from the GND terminal to the ground bus. p. 7
  • After a shutdown, wait 15 seconds before applying power again. p. 7

Questions this manual answers

What is the 1771-CP1 cable used for?

It is the 0.32m (1.04ft) cable that connects a 1771-P7 mounted on the left side of a panel-mounted I/O chassis to the chassis D-shell connector. p. 2, 3

Which I/O chassis can the 1771-P7 power?

One 1771-A1B, -A2B, -A3B, -A3B1 or -A4B chassis; it does not work with the 1771-A1, -A2 or -A4. p. 1

How do I set the 1771-P7 for 230V?

With the power switch off, set the input voltage selector switch to the 230 position for 195 to 264V ac. p. 6

What fuse does the 1771-P7 take?

A 3A, 250V 3AG normal blow fuse, Bussmann AGC 3 or Littelfuse 312003. p. 8

Why is the 1771-P7 P/S ACTIVE light off?

The input voltage may be out of range, the fuse may be blown, or there may be an overcurrent. p. 7

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1771-2.93, AC (120/220V) 16A Power Supply1
  2. To the Installer1
  3. Prepare for Installation1
  4. Install the 1771 P7 and Connect Backplane Power2
  5. Connect ac Power Source to the Power Supply6
  6. Troubleshooting7
  7. Specifications8
  8. Power Ratings8
  9. Back Cover8

From the PDF’s own bookmarks.

The whole text · 1 part

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8

The file

Revision and size

RevisionPublication 1771-2.93, March 1994
PublisherAllen-Bradley
Pages8
PDF339 KB
TextText from the PDF itself.

The first pages · 3 of 8

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 8
Page 2
Page 2of 8
Page 3
Page 3of 8