Page 69
1756 ControlLogix I/O Modules
1756-IF8 – Differential Current Applications
1756-IF8 – Differential Voltage Applications Channel 0
Channel 0 i
To field device
A
Shield ground Channel 3 2-Wire Transmitter i A
IN-0
2
1 i RTN-0
IN-1
4
3 i RTN-1
IN-2
6
5 i RTN-2
IN-3
8
7 i RTN-3
RTN
10
9
RTN
IN-4
12 11 14 13 i RTN-5
IN-6
16 15 i RTN-6
IN-7
18 17 i RTN-7
Not used
20 19
Not used
Not used
22 21
Not used
Not used
24 23
Not used
Not used
26 25
Not used
Not used
28 27
Not used
Not used
30 29
Not used
Not used
32 31
Not used
Not used
34 33
Not used
Not used
36 35
Not used
+ –
Jumper wires i RTN-4
IN-5
7-9
Shield ground
Channel 3
+ –
Shield ground
IN-0
2
1 i RTN-0
IN-1
4
3 i RTN-1
IN-2
6
5 i RTN-2
IN-3
8
7 i RTN-3
RTN
10
9
RTN
IN-4
12
11 i RTN-4
IN-5
14
13 i RTN-5
IN-6
16
15 i RTN-6
IN-7
18
17 i RTN-7
Not used Not used
20
19
22
21
Not used Not used
Not used
24
23
Not used
Not used
26
25
Not used
Not used
28
27
Not used
Not used
30
29
Not used
Not used
32
31
Not used
Not used
34
33
Not used
Not used
36
35
Not used
NOTES: 1. Use the following chart when wiring your module in differ ential mode NOTES: 1. Use the following chart when wiring your module in differential mode
Thi s channel:
Uses t hese ter minals:
Thi s channel:
Uses these terminals:
This channel:
Uses these terminals:
This channel :
Uses these ter minals:
Channel 0
IN-0 & IN-1
Channel 2
IN-4 & IN-5
Channel 0
IN-0, IN-1 & i RTN-0
Channel 2
IN-4, IN-5 & i RTN-4
Channel 1
IN-2 & IN-3
Channel 3
IN-6 & IN-7
Channel 1
IN-2, IN-3 & i RTN-2
Channel 3
IN-6, IN-7 & i RTN-6
2. When operating in 2 channel, high speed mode, only use channels 0 and 2. 3. All terminals marked RTN are connected internally. 4. If multiple (+) or multiple (-) terminals are tied together, connect that tie point to a RTN terminal to maintain the module’s accuracy. 5. Terminal marked RTN or i RTN are not used in differential voltage applications. 6. Do not connect more than 2 wires to any single terminal.
2. When operating in 2 channel, high speed mode, only use channels 0 and 2. 3. All terminals marked RTN are connected internally. 4. A 249Ω current loop resistor is located between IN-x and i RTN-x terminals. 5. If multiple (+) or multiple (-) terminals are tied together, connect that tie point to a RTN terminal to maintain the module’s accuracy. 6. Place additional loop devices (e.g. strip chart recorders, etc.) at the A location. 7. If separate power sources are used, do not exceed the specified isolation voltage. 8. Do not connect more than 2 wires to any single terminal.
1756-IF8 – Single-Ended Current Applications Channel 0 i
To field device
Channel 0 IN-0
2
1 i RTN-0
IN-1
4
3 i RTN-1
IN-2
6
5 i RTN-2
Shield ground
IN-3
8
7 i RTN-3
Channel 5
RTN
10
9
RTN
2-Wire Transmitter
1756-IF8 – Single-Ended Voltage Applications i A
Jumper wires
+ –
Shield ground
IN-0
2
1 i RTN-0
IN-1
4
3 i RTN-1
IN-2
6
5 i RTN-2
IN-3
8
7 i RTN-3
RTN
10
9
RTN
IN-4
12
11 i RTN-4
IN-5
14
13 i RTN-5
IN-6
16
15 i RTN-6
IN-4
12 11 i RTN-4
IN-5
14 13 i RTN-5
IN-6
16 15 i RTN-6
IN-7
18 17 i RTN-7
Not used
20 19
Not used
IN-7
18
17 i RTN-7
Not used
22 21
Not used
Not used
20
19
Not used
Not used
24 23
Not used
Not used
22
21
Not used
Not used
26 25
Not used
Not used
24
23
Not used
Not used
28 27
Not used
Not used
26
25
Not used
Not used
30 29
Not used
Not used
28
27
Not used
Not used
32 31
Not used
Not used
30
29
Not used
Not used
34 33
Not used
Not used
32
31
Not used
Not used
36 35
Not used
Not used
34
33
Not used
Not used
36
35
Not used
NOTES: 1. All terminals marked RTN are connected internally. 2. For current applications, all terminals marked iRTN must be wired to terminals marked RTN. 3. A 249Ω current loop resistor is located between IN-x and i RTN-x terminals. 4. Place additional loop devices (e.g. strip chart recorders, etc.) at the A location. 5. Do not connect more than 2 wires to any single terminal.
Channel 1
+ –
Shield ground
NOTES: 1. All terminals marked RTN are connected internally. 2. Terminals marked iRTN are not used for single-ended voltage wiring. 3. Do not connect more than 2 wires to any single terminal.
Publication CIG-WD001B-EN-P - May 2005
Page 70
7-10
1756 ControlLogix I/O Modules
1756-IG16 2
1
4
3
IN-1 6
5
8
7
IN-5 DC power wire
IN-7 10
1
IN-0
4
3
6
5
IN-1 IN-2
IN-4
DC-3 (-)
GND-3
8
7
IN-3
GND-4 GND-5 GND-6
10 9
IN-4 IN-5 IN-6
GND-7 GND-8
16 15
GND-9 GND-10 GND-11
20 19
GND-12 GND-13
26 25
GND-14 GND-15
30 29 32 31
IN-14 IN-15
GND-15
34 33
Not used
Not used
36 35
Not used
I/O wire
9
DC COM 0 12
DC-7 (-)
11
IN-8
IN-9 14
13
16
15
Jumper bar (Cut to length)
IN-10
IN-11 5V dc power
2
GND-1 GND-2
IN-6
DC-0(+)
–
DC-0 (-) Isolat ed wir ing
GND-0
IN-2
IN-0
IN-3
+
1756-IH16I
Capacitor 0.01µ F typical (See notes below)
IN-12
IN-13 18
17
IN-14
IN-15 20
Non- isolated wi ring
19
DC COM 1
DC-1(+)
DC (-)
12 11 14 13 18 17 22 21 24 23 28 27
IN-7 IN-8
DC-0 (+)
DC-3 (+)
DC-7 (+)
IN-9 IN-10 IN-11 IN-12 IN-13
DC (+)
GENERAL NOTES: 1. We recommend you use Belden M 8761 cable where shielded cables are shown. Daisy chain to other RTBs
2. Do not connect more than two wires to any single terminal. CE REQUIREMENT NOTES: 1. DC power wire and I/O wire should not exceed 10m (30ft) in length. 2. The 0.01µ F capacitors shown above must be rated for 2000V dc.
NOTES: 1. All terminals with the same name are connected together on the module. For example, DC (-) can be connected to either terminal marked GND-15. 2. When you use the second GND-15 terminal to daisy chain to other RTBs, always connect the daisy chain to the terminal directly connected to the supply wire, as shown in the example above. Do not connect more than 2 wires to any single terminal. 3. If separate power sources are used, do not exceed the specified isolation voltage.
1756-IH16ISOE Isolated wiring
DC-0 (-)
Source input wiring
DC-6 (-)
Jumper bar (Part number 97739201)
Non-isolated wiring DC (-)
1756-IM16I Sink input wiring
GND-0 GND-1 GND-2 GND-3 GND-4 GND-5 GND-6 GND-7 GND-8 GND-9 GND-10 GND-11 GND-12 GND-13 GND-14 GND-15 GND-15 Not used
2
1
4
3
6
5
8
7
10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35
IN-0 DC-0 (+) IN-1 IN-2 IN-3 IN-4 Source input wiring IN-5 IN-6 DC-6 (+) IN-7 IN-8 IN-9 IN-10 IN-11 Sink input wiring IN-12 IN-13 IN-14 IN-15 Not used Not used DC (+)
Daisy chain to other RTBs NOTES:
1. All terminals with the same name are connected together on the module. For example, DC (-) can be connected to either terminal marked GND-15. 2. When you use the second GND-15 terminal to daisy chain to other RTBs, always connect the daisy chain to the terminal directly connected to the supply wire, as shown in the example above. 3. If separate power sources are used, do not exceed the specified isolation voltage. 4. Do not connect more than 2 wires to any single terminal. 5. The jumper bar is part number 97739201; use this number to order additional bars.
Publication CIG-WD001B-EN-P - May 2005
Is olate d wiri ng L2-0 L2-2 L2-4
Jumper bar (Cut to length)
Non-isol ated wir ing
L2
L2-0
2
1
IN-0
L2-1
4
3
IN-1
L2-2
6
5
IN-2
L2-3
8
7
IN-3
L2-4
10
9
IN-4
L2-5
12 11
IN-5
L2-6
14 13
IN-6
L2-7
16 15
IN-7
L2-8
18 17
IN-8
L2-9
20 19
IN-9
L2-10
22 21
IN-10
L2-11
24 23
IN-11
L2-12
26 25
IN-12
L2-13 L2-14
28 27 30 29
IN-13 IN-14
L2-15
32 31
IN-15
L2-15 Not used
34 33
Not used Not used
36 35
L1-0 L1-2 L1-4
L1 Daisy chain to other RTBs NOTES: 1. All terminals with the same name are connected together on the module. For example, L2 can be connected to either terminal marked L2-15. 2. When you use the second L2-15 terminal to daisy chain to other RTBs, always connect the daisy chain to the terminal directly connected to the supply wire, as shown in the example above. Do not connect more than 2 wires to any single terminal. 3. If separate power sources are used, do not exceed the specified isolation voltage.
Page 71
1756 ControlLogix I/O Modules
1756-IN16
1756-IR6I – 2 or 3-Wire RTD 2
2
1
4
3
6
5
8
7
IN-1 IN-3 IN-5
10
9
14
IN-8
RTN-3/C
IN-10
Not used
13
IN-11 16
15
18
17
IN-13
IN-12
IN-15
Group 1
20
8
7
IN-0/B RTN-0/C 3-Wire RTD IN-2/A 10
9
12
11
IN-2/B
14
13
16
15
18
17
20
19
Not used IN-4/A
IN-5/B
19
L2-1
Shield Ground
RTN-2/C
IN-5/A
IN-14
L2-1
5
IN-3/B
11
IN-9
6
IN-3/A
L2-0 12
Group 1
Group 0 IN-6
L2-0
3
RTN-1/C
IN-4
IN-7
IN-0/A 4
IN-1/B
IN-2
Group 0
L2
1
IN-1/A IN-0
L1
7-11
IN-4/B
RTN-5/C
2-Wire RTD
RTN-4/C
Daisy chain to other RTBs NOTES:
1. All terminals with the same name are connected together on the module.For example, L2 can be connected to any terminal marked L2-0. 2. When you daisy chain from a group to another RTB, always connect the daisy chain to the terminal directly connected to the supply wire, as shown above. 3. This wiring example shows a s ingle voltage source. 4. If separate power sources are used, do n ot exceed the specified isolation voltage. 5. Do not connect more than 2 wires to any single terminal.
NOTES: 1. For 2-wire resistor applications, including calibration, make sure IN-x/B and RTN-x/C are shorted together. The example above shows IN-4/B and RTN-4/C shorted together.
2. Do not connect more than 2 wires to any single terminal.
1756-IR6I – 4-Wire RTD 2
1756-IT6I
1
IN-1/A 4
Co ld junc tion sensor
5
RTN-1/C
RTN-0/C 8
4-Wire RTD
7
IN-3/A 9
12
11
IN-3/B
6
5
8
7
10
9
Not used
Lug
RTN-0
Shield Ground
12
11
14
13
16
15
18
17
20
19
RTN-2 Not used
CJC-
14
13
Not used
Not used Wire
16
IN-4/A 18
IN-4/B 20
RTN-5/C
Not used
Not used
17
IN-5/B
IN-4
IN-5
15
IN-5/A
RTN-5
Thermocouple
Not used
RTN-3
RTN-2/C
– IN-2
IN-3 CJC+
IN-2/B
RTN-3/C
3
RTN-1
IN-2/A 10
4
Not used
IN-0/B 6
IN-0
IN-0
3
IN-1/B
+
1
2
IN-0/A
RTN-4
19
RTN-4/C
NOTES: 1. Wiring is exactly the same as the 3-wire RTD with one wire left open. 2. Do not connect more than 2 wires to any single terminal.
NOTES: 1. If separate power sources are used, do not exceed the specified isolation voltage. 2. Do not connect more than 2 wires to any single terminal. 3. The part number for the cold junction sensor used on the 1756-IT6I module is 94238301.
Publication CIG-WD001B-EN-P - May 2005
Page 72
7-12
1756 ControlLogix I/O Modules
1756-IT6I2
1756-IV16
Cold junction sensor Wire
Spade Lug 2
1
Not used 3
6
5
CJC–
CJC+
RTN-0
6
5
Group 0 IN-4
IN-5
Thermocouple
+
8
7
10
9
12
11
14
13
16
15
18
17
20
19
IN-6
IN-7
DC-0 +
DC-0 +
IN-1
IN-8
IN-9
9
RTN-2
IN-2 12
3
IN-2
Group 0
7
RTN-1 10
4
IN-0
IN-0 8
1
IN-3
Not used 4
2
IN-1
RTN-3
Group 1
IN-3 14
13
16
15
18
17
20
19
IN-10
IN-11
–
11
RTN-4
CJC–
IN-14
DC-1 +
IN-5
Group 1
IN-12
IN-15
IN-4
RTN-5
IN-13
DC-1 +
CJC+
+
Not used
–
DC COM
Not used Daisy chain to other RTBs
Wire
Cold junction sensor
Spade Lug
NOTES: 1. Do not connect more than 2 wires to any single terminal. 2. The part number for the cold junction sensor used on the 1756-IT6I2 module is 94286501.
1756-IV32
Group 0
Daisy chain to other RTBs
Jumper wire
Group 1
NOTES: 1. All terminals with the same name are connected together on the module. For example, DC (+) can be connected to either terminal marked DC-1+. If you are daisy chain wiring from one of these terminals to other RTBs, only connect wiring to one terminal. 2. When you daisy chain from a group to another RTB, always connect the daisy chain to the terminal directly connected to the supply wire, as shown above. Do not connect more than 2 wires to any single terminal. 3. This wiring example shows a single voltage source. 4. If separate power sources are used, do not exceed the specified isolation voltage.
1756-MO2AE – Wiring to a Servo Module RTB
IN-1
2
1
IN-0
IN-3
4
3
IN-2
IN-5
6
5
IN-4
IN-7
8
7
IN-6
IN-9
10
9
IN-8
IN-11
12 11
IN-10
IN-13
14 13
IN-12
IN-15
16 15
IN-14
6
5
8
7
10
9
12
11
14
13
16
15
-ENABLE-1
IN-16
REG24V-0
IN-18
REG5V-0
IN-21
24 23
IN-20
+OK
IN-23
26 25
IN-22
CHASSIS
IN-25
28 27
IN-24
IN-27
30 29
IN-26
IN-29
32 31
IN-28 IN-30
34 33
DC-1 (+)
36 35
– DC COM
1. All terminals with the same name are connected together on the module. For example, DC (+) can be connected to either terminal marked DC-1 (+). 2. Do not physically connect more than two wires to a single RTB terminal. When jumpering I/O groups together and daisy chain wiring to adjacent modules, follow the wiring method shown above. 3. This wiring example shows a single voltage source. 4. If separate power sources are used, do not exceed the specified isolation voltage.
Publication CIG-WD001B-EN-P - May 2005
IN_COM
General Cable C0720
To home limit switch
General Cable C0720
To registration sensor
HOME-1 18
17
20
19
REG24V-1 REG5V-1 22
21
24
23
26
25
28
27
30
29
32
31
34
33
36
35
-OK CHASSIS +CHA-1
+CHA-0
Group 1
To servo drive
CHASSIS
HOME-0
22 21
General Cable C0721
DRVFLT-1
IN_COM
20 19
To servo drive
+ENABLE-1
CHASSIS
IN-17 IN-19
General Cable C0720
-OUT-1
DRVFLT-0
-CHA-0
-CHA-1
+CHB-0
+CHB-1
-CHB-0
General Cable C0722
To encoder
General Cable C0720
To E-stop relay coil
-CHB-1 +CHZ-1
+CHZ-0 -CHZ-0
NOTES:
+OUT-1
-ENABLE-0
DC-0 (+)
+
3
+ENABLE-0
Group 0
18 17
DC-1 (+)
1
4
-OUT-0
DC-0 (+)
IN-31
2
+OUT-0
-CHZ-1
This is a general wiring example illustrating Axis 1 wiring only. Other configurations are possible with Axis 0 wiring identical to Axis 1.
Page 73
1756 ControlLogix I/O Modules
1756-MO2AE – Wiring to 1394 Servo Drive (in Torque Mode only)
1756-MO2AE – Wiring to an Ultra 100 Series Drive J1 to 50-pin Terminal Block (Kit P/N 9109-1391)
Servo Module RTB +OUT 1 -OUT 1 +ENABLE 1 -ENABLE 1 DRVFLT 1 CHASSIS IN_COM HOME 1 REG24V 1 REG5V 1 -OK CHASSIS +CHA 1 -CHA 1 +CHB 1 -CHB 1 +CHZ 1 -CHZ 1
+OUT 0 -OUT 0 +ENABLE 0 -ENABLE 0 DRVFLT 0 CHASSIS IN_COM HOME 0 REG24V 0 REG5V 0 +OK CHASSIS +CHA 0 -CHA 0 +CHB 0 -CHB 0 +CHZ 0 -CHZ 0
RED BLK WHT BLK RED BLK
A
General Cable C0720
From 1756-M02AE
+5V DC +5 COM
To fault string
General Cable C0721
From 1756-M02AE
24VDC 24VDC READY+ 24VCOM 24VCOM
+OUT
J1-22 COMMAND+
-OUT
J1-23 COMMAND-
P/N 9109-1369-003
-ENABLE
J1-20 ENABLE
DRVFLT
J1-25 READY-
Interface Cable
J1
IN_COM
ENC. PWR -1
1394 Ser vo Drive 24V DC
24V DC Field Power Supply
ENA/DR OK 1
J1-5 J1-26 J1-24 J1-6 J1-13
+ENABLE
RED OK+ BLK OK-
RED BLK
24 VCOM
Ultra 100 Series Digital Servo Drive
1394CCAExx
WHT BLK RED BLK GRN BLK OK
5V DC Field Power Supply
24 VDC
24 VDC Field Power Supply
1756-M02AE
7-13
24V COM
WHT BLK RED BLK
+ENABLE 1 -ENABLE 1 DRVFLT 1 IN_COM
W2 24V DC
General Cable C0722
From 1756-M02AE
W1 24V COM TB2 15 24V ENABLE COM
TB2 7 A1 ENABLE TB2 19 DROK TB2 18 DROK
+CHA
J1-7 AOUT+
-CHA
J1-8 AOUT-
+CHB
J1-9 BOUT+
-CHB
J1-10 BOUT-
+CHZ
J1-11 IOUT+
-CHZ
J1-12 IOUT-
This is general wiring example only. Other configurations are possible. For more information, refer to the Ultra 100 series installation manual, publication number 1398-5.2. A
NOTES:
1394CCAExx
Axis 1
AQB1
1. The wiring diagram illustrates Axis 1 wiring only. Other configurations are possible. 2. The 1394-CCAExx cable is wired to connect to torque command reference input pins. 3. An external +5V power supply is required to power the encoder driver circuit of the 1394 servo drive.Because this connection is shared by all four axis encoder driver circuits, only one connection is needed to the +5V field supply. 4. The xx in the cable number is the length of the cable. Options are 5, 10, 25 and 50 feet.
1756-MO2AE – Wiring to an Ultra 200 Series Drive J1 to 50-pin Terminal Block (Kit P/N 9109-1391)
Ultra 200 Series Digital Servo Drive
J1-5 24VDC J1-24 READY+ J1-6 or 13 24VCOM
From 1756-M02AE
General Cable C0720
+OUT
J1-22 COMMAND+
-OUT
J1-23 COMMAND-
P/N 9109-1369-003
+ENABLE From 1756-M02AE
General Cable C0721
-ENABLE
J1-20 ENABLE
DRVFLT
J1-25 READY-
Interface Cable
J1
IN_COM
From 1756-M02AE
General Cable C0722
+CHA
J1-7 AOUT+
-CHA
J1-8 AOUT-
+CHB
J1-9 BOUT+
-CHB
J1-10 BOUT-
+CHZ
J1-11 IOUT+
-CHZ
J1-12 IOUT-
This is general wiring example only. Other configurations are possible. For more information, refer to the Ultra 200 series installation manual, publication number 1398-5.0.
Publication CIG-WD001B-EN-P - May 2005
Page 74
7-14
1756 ControlLogix I/O Modules
1756-MO2AE – Wiring 24V Registration Sensors 24 VDC Field Power Supply
+
-
1756-MO2AE – Wiring 5V Registration Sensors 5 VDC Field Power Supply
24 V olt Sourcing Type Registration Sensor
5 Volt Sourcing Type Registration Sensor
+ -
Supply
Supply From 1756-M02AE
General Cable C0720
REG24V
Output
IN_COM
Common
General Cable C0720
From 1756-M02AE
REG5V
Output
IN_COM
Common
The registration inputs to the servo module support 24V or 5V registration sensors. These inputs must be wired to receive source current from the sensor. Only use sourcing type registration sensors. 1756-MO2AE – Wiring Home Limit Switch Input
1756-MO2AE – Wiring OK Contacts 24 VDC Field Power Supply
24 VDC Field Power Supply + -
+
-
OK Relay
From 1756-M02AE
General Cable C0720
HOME
From 1756-M02AE
+OK
General Cable C0720
-OK
IN_COM
The home limit switch inputs to the servo module are designed for 24V nominal operation. These inputs should be wired for current sourcing operation.
+ 24 VDC Field Power Supply
OK Relay Contacts +OK
Start
-OK
CR1
-
Stop
CR1
CR1 To User's circuitry M1
When the OK Relay is loaded with an inductive load, use a counter-EMF suppression diode across the load. The maximum rating of the OK relay contacts must not exceed 60V dc.
1756-M08SE and 1756-M16SE
Receiv er Transmitter
Fiber optic connectors
Publication CIG-WD001B-EN-P - May 2005
Page 75
1756 ControlLogix I/O Modules
1756-OA16 2
1756-OA16I Is olate d wiri ng
1
OUT-1
OUT-0 4
Group 0
OUT-2 6
5
OUT-5
OUT-4
L1-2
Group 0 L1-4
7
8
OUT-7
OUT-6 10
9
12
11
L1-0
L2-0
OUT-9
Jumper bar - Cut to length (Part number 97739201)
OUT-8 14
13
OUT-11
OUT-10 16
Group 1
L1-0
3
OUT-3
Daisy chain to other RTBs
15
OUT-13
OUT-12 18
17
OUT-15
Non-isolated wiring
Group 1
OUT-14 20
7-15
19
L1-1
L2-1
L1
L1-0
2
1
OUT-0
L1-1
4
3
OUT-1
L1-2
6
5
OUT-2
L1-3
8
7
OUT-3
L1-4
10
9
OUT-4
L1-5
12 11
OUT-5
L1-6
14 13
OUT-6
L1-7
16 15
OUT-7
L1-8
18 17
OUT-8
L1-9
20 19
OUT-9
L1-10
22 21
OUT-10
L1-11
24 23
OUT-11
L1-12
26 25
OUT-12
L1-13 L1-14
28 27
OUT-13
30 29
OUT-14
L1-15
32 31
OUT-15
L1-15 Not used
34 33
Not used Not used
36 35
L2-0 L2-2 L2-4
L2
L1
Daisy chain to other RTBs
L2
NOTES: 1. This wiring example shows a single voltage source. 2. When you daisy chain from a group to other RTBs, always connect the daisy chain as shown. Do not connect more than 2 wires to any single terminal at any time.
NOTES: 1. All terminals with the same name are connected together on the module. For example, L1 can be connected to either terminal marked L1-15. 2. When you use the second L1-15 terminal to daisy chain to other RTBs, always connect the daisy chain to the terminal directly connected to the supply wire, as shown in the example above. Do not connect more than 2 wires to any single terminal.
1756-OA8 2
1
OUT-0
L1-0 4
OUT-1 6
5
8
7
10
9
12
11
14
13
16
15
Daisy chain to other RTBs
OUT-5
L1-1
Group 1
OUT-6
L1-1 18
OUT-7 20
L1-1
7
10
9
12
11
14
13
16
15
18
17
20
19
OUT-1
OUT-3 OUT-4
L1-1
OUT-5
L1-1
OUT-6
L1-1
L2
L1-1
Group 0
OUT-2
L1-1
19
Not used
8
OUT-0
L1-0
Group 1
17
L1-1
5
L1-0
OUT-4
L1-1
6
L2-0
L1-0
Not used
L1-0
Group 1
Group 0
Group 0
OUT-3
L1-0
1
3
L1-0
OUT-2
L1-0
2
4
Not used
3
L1-0 Group 0
1756-OA8D
Group 1 OUT-7 L2-1 L2
Daisy chain to other RTBs
Daisy chain to other RTBs L1 L1
NOTES: 1. All terminals with the same name are connected together on the module. For example, L1 can be connected to any terminal marked L1-0. 2. When you daisy chain from a group to another RTB, always connect the daisy chain to the terminal directly connected to the supply wire, as shown above. Do not connect more than 2 wires to any single terminal. 3. This wiring example shows a single voltage source.
NOTES: 1. All terminals with the same name are connected together on the module. For example, L1 can be connected to any terminal marked L1-0. 2. When you daisy chain from a group to another RTB, always connect the daisy chain to the terminal directly connected to the supply wire, as shown above. Do not connect more than 2 wires to any single terminal. 3. This wiring example shows a single voltage source.
Publication CIG-WD001B-EN-P - May 2005
Page 76
7-16
1756 ControlLogix I/O Modules
1756-OA8E 2
Daisy chain to other RTBs
1
L2-0
Not used 4
3
OUT-0
L1-0 6
5
L1-0
Group 0
OUT-1 8
Group 0
OUT-2 10
9
12
11
L1-0
OUT-3 OUT-4
L1-1 14
13
L1-1
OUT-5 16
15
OUT-6
L1-1 18
17
OUT-7
L1-1
Group 1
Group 0
7
L1-0
Daisy chain to other RTBs
1756-OB16D
20
Group 1 Group 1
19
L2-1
L1-1
L2 Daisy chain to other RTBs
+DC-0
2
1
OUT-0
+DC-0
4
3
OUT-1
+DC-0
6
5
OUT-2
+DC-0
8
7
OUT-3
+DC-0
10
9
OUT-4
+DC-0
12
11
OUT-5
+DC-0
14
13
OUT-6
GND-0
16
15
OUT-7
+DC-1
18
17
OUT-8
+DC-1 +DC-1
20
19
OUT-9
22
21
OUT-10
+DC-1
24
23
OUT-11
+DC-1
26
25
OUT-12
+DC-1
28
27
OUT-13
+DC-1
30
29
OUT-14
GND-1
32
31
OUT-15
GND-1
34
33
Not used
Not used
36
35
Not used
Group 0
Group 1
Daisy chain to other RTBs L1
+ NOTES:
1. All terminals with the same name are connected together on the module. For example, L1 can be connected to any terminal marked L1-0. 2. When you daisy chain from a group to another RTB, always connect the daisy chain to the terminal directly connected to the supply wire, as shown above. Do not connect more than 2 wires to any single terminal. 3. This wiring example shows a single voltage source.
NOTES 1. All terminals with the same name are connected together on the module. For example, DC COM can be connected to either terminal marked GND-1. 2. When you daisy chain to other RTBs, always connect the daisy chain to the terminal directly connected to the supply wire, as shown in the example above. Do not connect more than 2 wires to any single terminal. 3. This wiring example shows a single voltage source. 4. If separate power sources are used, do not exceed the specified isolation voltage.
1756-OB16E 2
DC-0 (+)
2
1
OUT-0
DC-1 (+)
4
3
OUT-1
DC-2 (+)
6
5
OUT-2
DC-3 (+)
8
7
OUT-3
DC-4 (+)
10
9
OUT-4
DC-5 (+)
12
11
OUT-5
DC-6 (+)
14
13
OUT-6
DC-7 (+)
16
15
OUT-7
Jumper bar - Cut to length
DC-8 (+)
18
17
OUT-8
(Part number 97739201)
DC-9 (+)
20
19
OUT-9
DC-10 (+)
22
21
OUT-10
DC-11 (+)
24
23
OUT-11
DC-12 (+)
26
25
OUT-12
DC-13 (+)
28
27
OUT-13
DC-14 (+)
30
29
OUT-14
DC-15 (+)
32
31
OUT-15
DC-15 (+) Not used
34
33
36
35
Not used Not used
DC-0 (+)
3
OUT-3
OUT-2 6
Daisy chain to other RTBs
Isol ated sour cing out put wir ing
Isolat ed wir ing
OUT-0 4
Group 0
1756-OB16I
1
OUT-1
Group 0 DC-2 (+)
5
OUT-5
OUT-4 8
7
OUT-7
OUT-6 10
Sin k ing outp ut wir ing
9
DC-6 (+)
DC-0(+)
RTN OUT-0 12
11
14
13
OUT-9
OUT-8
OUT-11
OUT-10 16
15
OUT-13
Non-i solated wir ing
OUT-12
Group 1
18
17
20
19
Group 1
OUT-15
OUT-14
DC-1(+)
RTN OUT-1
+
– DC COM
DC(+)
+
–
DC-0 (-) DC-2 (-)
DC-6 (-)
Non-isol ated sourc ing outp ut wir ing
DC(-)
– DC COM
NOTES: 1. When you daisy chain from a group to another RTB, always connect the daisy chain as shown above. Do not connect more than 2 wires to any single terminal. 2. This wiring example shows a single voltage source. 3. If separate power sources are used, do not exceed the specified isolation voltage.
Publication CIG-WD001B-EN-P - May 2005
Daisy chain to other RTBs NOTES:1. All terminals with the same name are connected together on the module. For example, DC (+) can be connected to either terminal marked DC-15. 2. When you use the second DC-15 (+) terminal to daisy chain to other RTBs, always connect the daisy chain to the terminal directly connected to the supply wire, as shown in the example above. Do not connect more than 2 wires to any single terminal. 3. Outputs can be wired in a sink or source configuration as shown above. 4. If separate power sources are used, do not exceed the specified isolation voltages.