Page 107

Chapter

10

1764 Controller I/O on MicroLogix 1500 Controllers

Expansion I/O for the MicroLogix 1500 controllers is accomplished with the 1769 Compact I/O modules. For more information on wiring the 1769 Compact I/O modules, see Chapter 11.

IMPORTANT

1764-24AWA

Input Terminals

L2

Terminal Groupings NOT AC IN 1 USED COM 0 NOT USED

IN 0

IN 3

IN 4

IN 6

AC IN 2 COM 1 IN 5

AC IN 9 COM 2

IN 7

IN 8

IN 11

In put Gr oup Group 0 Group 1 Group 2

IN 10

Common Termin al AC COM 0 AC COM 1 AC COM 2

In put Termin al I/0 through I/3 I/4 through I/7 I/8 through I/11

L1 L2 L1 “NOT USED” terminals are not intended for use as connection points.

Output Terminals

CR

CR

L2

Terminal Groupings

(Lo) VAC VAC/ VAC/ VAC/ VAC/ VAC/ NEUT VDC 0 VDC 1 VDC 2 VDC 3 VDC 4 OUT 5 OUT 7 OUT 8 OUT 10 VAC/ 120/240 EARTH OUT 0 OUT 1 OUT 2 OUT 3 OUT 4 OUT 6 OUT 9 OUT 11 VDC 5 VAC GND

(Hi) L1

1

CR

CR

CR

CR

Out put Gr oup Group 0 Group 1 Group 2 Group 3 Group 4 Group 5

Voltage Term inal VAC/VDC 0 VAC/VDC 1 VAC/VDC 2 VAC/VDC 3 VAC/VDC 4 VAC/VDC 5

Ou tput Terminal O/0 O/1 O/2 O/3 O/4 through O/7 O/8 through O/11

Publication CIG-WD001B-EN-P - May 2005

Page 108

10-2

1764 Controller I/O on MicroLogix 1500 Controllers

1764-24BWA - Sinking Inputs Input Terminals

Terminal Groupings +24V DC IN 1 POWER OUT COM 0 COM

IN 0

IN 3

IN 2

IN 4

DC IN 5 COM 1

-DC

DC COM 2

IN 6

IN 7

IN 9

IN 8

In put Gr oup Group 0 Group 1 Group 2

IN 11

IN 10

Common Termin al DC COM 0 DC COM 1 DC COM 2

In put Termin al I/0 through I/3 I/4 through I/7 I/8 through I/11

+DC

Output Terminals

CR

CR

Terminal Groupings

L2 (Lo) VAC VAC/ VAC/ VAC/ VAC/ VAC/ OUT 5 OUT 7 OUT 8 OUT 10 NEUT VDC 0 VDC 1 VDC 2 VDC 3 VDC 4 VAC/ 120/240 EARTH VAC GND OUT 0 OUT 1 OUT 2 OUT 3 OUT 4 OUT 6 VDC 5 OUT 9 OUT 11

(Hi)

CR

L1

CR

CR

Out put Gr oup Group 0 Group 1 Group 2 Group 3 Group 4 Group 5

Voltage Term inal VAC/VDC 0 VAC/VDC 1 VAC/VDC 2 VAC/VDC 3 VAC/VDC 4 VAC/VDC 5

Ou tput Terminal O/0 O/1 O/2 O/3 O/4 through O/7 O/8 through O/11

CR

1764-24BWA - Sourcing Inputs Input Terminals

Terminal Groupings +24V POWER DC IN 1 OUT COM 0 COM

IN 0

IN 2

IN 3

IN 4

IN 6

DC IN 5 COM 1

DC IN 9 COM 2

IN 7

IN 8

In put Gr oup Group 0 Group 1 Group 2

IN 11

IN 10

Common Termin al DC COM 0 DC COM 1 DC COM 2

In put Termin al I/0 through I/3 I/4 through I/7 I/8 through I/11

+DC -DC

Output Terminals

CR L2

CR

Terminal Groupings

(Lo) VAC VAC/ VAC/ VAC/ VAC/ VAC/ NEUT VDC 0 VDC 1 VDC 2 VDC 3 VDC 4 OUT 5 OUT 7 OUT 8 OUT 10 120/240 EARTH VAC/ OUT 0 OUT 1 OUT 2 OUT 3 OUT 4 OUT 6 OUT 9 OUT 11 VAC GND VDC 5

L1

(Hi)

Publication CIG-WD001B-EN-P - May 2005

CR

CR

CR

CR

Out put Gr oup Group 0 Group 1 Group 2 Group 3 Group 4 Group 5

Voltage Term inal VAC/VDC 0 VAC/VDC 1 VAC/VDC 2 VAC/VDC 3 VAC/VDC 4 VAC/VDC 5

Ou tput Terminal O/0 O/1 O/2 O/3 O/4 through O/7 O/8 through O/11

Page 109

1764 Controller I/O on MicroLogix 1500 Controllers

10-3

1764-28BXB - Sinking Inputs Input Terminals -DC +DC

-DC +DC

Terminal Groupings NOT DC IN 1 USED COM 0 NOT IN 0 USED

IN 3

IN 4

DC IN 5 COM 1

IN 2

DC IN 9 COM 2

IN 6

IN 7

IN 11 IN 13 IN 15

IN 10 IN 12 IN 14

IN 8

In put Gr oup Group 0 Group 1 Group 2

Common Termin al DC COM 0 DC COM 1 DC COM 2

In put Termin al I/0 through I/3 I/4 through I/7 I/8 through I/15

Out put Gr oup

Voltage Term inal

Ou tput Terminal

Group 0 Group 1 Group 2 Group 3 Group 4

VAC/VDC 0 VAC/VDC 1 VDC 2, VDC COM 2 VAC/VDC 3 VAC/VDC 4

O/0 O/1 O/2 through O/7 O/8 and O/9 O/10 and O/11

“NOT USED” terminals are not intended for use as connection points.

Output Terminals (FET Outputs are Sourcing Only)

CR

CR

CR

Terminal Groupings

-DC

COM VAC/ VAC/ VDC 2 OUT 3 OUT 5 OUT 7 VAC/ OUT 9 OUT 10 VDC 0 VDC 1 VDC 3 +24v EARTH OUT 0 OUT 1 OUT 2 OUT 4 OUT 6 VDC OUT 8 VAC/ OUT 11 COM 2 GND VDC 4

CR

+DC

CR

CR

Outputs 2 - 7 are FET outputs

1764-28BXB - Sourcing Inputs Input Terminals +DC -DC

+DC -DC

NOT DC IN 1 USED COM 0 NOT IN 0 USED

IN 3

IN 2

IN 4

IN 6

DC IN 5 COM 1

DC IN 9 COM 2

IN 7

IN 8

IN 11 IN 13 IN 15

IN 10 IN 12 IN 14

Terminal Groupings In put Gr oup Group 0 Group 1 Group 2

Common Termin al DC COM 0 DC COM 1 DC COM 2

In put Termin al I/0 through I/3 I/4 through I/7 I/8 through I/15

Out put Gr oup

Voltage Term inal

Ou tput Terminal

Group 0 Group 1 Group 2 Group 3 Group 4

VAC/VDC 0 VAC/VDC 1 VDC 2, VDC COM 2 VAC/VDC 3 VAC/VDC 4

O/0 O/1 O/2 through O/7 O/8 and O/9 O/10 and O/11

“NOT USED” terminals are not intended for use as connection points.

Output Terminals (FET Outputs are Sourcing Only

CR

CR

Terminal Groupings

CR

-DC

VAC/ VAC/ VAC/ COM VDC 2 OUT 3 OUT 5 OUT 7 OUT 9 OUT 10 VDC 0 VDC 1 VDC 3 +24V

+DC

VDC VAC/ EARTH OUT 0 OUT 1 OUT 2 OUT 4 OUT 6 OUT 8 OUT 11 COM 2 VDC 4 GND

CR

CR

CR

Outputs 2 - 7 are FET outputs

Publication CIG-WD001B-EN-P - May 2005

Page 110

10-4

1764 Controller I/O on MicroLogix 1500 Controllers

Notes:

Publication CIG-WD001B-EN-P - May 2005