Appendix

Switch Seitings

Switch Settings Here is a reference for switch settings for a 1771-KE/KF communication controller module. (Prior to revision H.)

Switch Assembly SW-1

Switch 1: Off - Full duplex On - Half duplex Switch 2: Off - Embedded response disabled On - Embedded response enabled Switch 3: Off - Duplicate message detection disabled On - Duplicate message detection enabled Switch 4: Off - RS-232-C handshaking disabled On - RS-232-C handshaking enabled Switch 5: Off - Remote diagnostics pass through On - Remote diagnostics enabled

Here is a reference for switch settings for a 1771-KE/KF communication controller module. {Revision H.)

with Sw-1 error with with If you want to check | parity | embedded select protcol as: as: as: responses: 1 2 3 4 5 full duplex BCG none no off | off | N/A] N/A] off full duplex BCC even no on | off off full duplex BCC none yes off | on off full duplex BCC even yes on] on off half duplex BCC none no off | off on half duplex BCC even no on | off on full duplex CRC none yes off | on on half duplex CRC none no on | on v vy jon If you want the module’s R§-232-C port to: set switch 3: Use handshaking signals on Ignore handshaking signals off

Page 192 read from a scan by OCR; it may hold reading errors

Page A-2 Switch Settings

If you want your module to: set switch 4: detect and ignore duplicate messages on accept all messages regardless of duplication off

A. First Digit Station (SW-2, SW-3, SW-4)

Switch Digit 1 2 Off Off 0 Off On 1 On Off 2 On On 3 B. Second and Third Digits Switch Digit 1 2 3 Off Off Off 0 Off Off On 1 Off On Off 2 Off On On 3 On Off Off 4 On Off On 5 On On Off 6 On On On 7 Data Highway Baud Rate (SW-5) Switch Baud Rate 1 2 38,400 Off Off 57,600 On On 76,800 On Off 115,200 Off On

Recommended

Page 193 read from a scan by OCR; it may hold reading errors

Page A-3 Switch Settings

Computer Link Baud Rate and Parity (SW-6)

Switch Baud Rate 1 2 3

110 Off Off Off 300 On Off Off 600 Off On Off 1200 On On Off 2400 Off Off On 4800 On Off On 9600 Off On On 19,200 On On On

If you have revisions A-G module:

Switch 4: On - Even parity Off - No

If you have revision H module:

Switch 4: On - Execute diagnostic command Off - Pass through diagnostic command

Page 194 read from a scan by OCR; it may hold reading errors

Page A-4 Switch Settings

1771-KE, -KF Communication Controller Module

Switch Data Highway Computer Link Baud Assembly Station Baud Rate Rate and Diagnostic

Pass Through.

O08 Bt 47a EE 4a See

B parity prior to series A revision H.

Page 195 read from a scan by OCR; it may hold reading errors

Appendix

Detailed Flow Charts

B.0 General

This appendix presents flow charts that give detailed views of an example of software logic for implementing full-duplex protocol. The flow charts in chapter 4 gave you a simplified view of this software logic.

We have not shown any error checking or recovery relating to interaction with the modem handshake driver, a third process. To do this would overly complicate the flow charts, and in many cases, such error checking and recovery are not needed.

Page 196 read from a scan by OCR; it may hold reading errors

Figure B.1, Data Flow Diagram for Full-Duplex Protocol

11652

Data Link Layer IN

Row Output Bytes

Multiplexer

Physical Link Layer

UART

Row Input Bytes

SENDCTL SENDDATA SENDETX

Messages

Separator

GETCODE

DLE ENQ

Messages

XMIT

Messages Which Have Been Sent (Or Have Failed)

a

Messages to be sent, -

Empty

DLE ENQ

RCVE

Buffers

Received Messages

Network Layer

Detailed Flow Charts

Page B-2

Page 197 read from a scan by OCR; it may hold reading errors

Page B-3

Detailed Flow Charts

Internal Storage: rr XMIT * NAK Counter

* Timeout Counter at.

Legend: Y « Default value used by the module GETMSG

Get Message from Network Layer

Reset NAK and Timeout Counters

I <a j SENDM

Send Message

_ y

WTAK TL SENDC Wait for ACK, NAK or Timeout Send N DLE ENQ °

3°

Received NAKs Received for this DLE NAK Message . 2?

3* Yes Timeouts for this Message ?

Received DLE ACK f

SIGFAIL SIGOK SIGFAIL Tell Network Tell Network Tell Network Layer of Layer Message Layer of Failure Was Sent Failure

11653

Figure B.2, Transmitter Routine for Full Duplex Protocol

Page 198 read from a scan by OCR; it may hold reading errors

Page B-4 Detailed Flow Charts eT

4 WTAK »

STARTTIME

Start the ACK Timeout

_- - ----- - -- - ---------4

I SLEEP i Receive No 1 a Response Go to Sleep { at WTRESP { - Yes Indivisible Zone { y STOPTIME . Common: Cancel the ® WTRESP: A Sleep Location ACK Timer

Get the Response Code (if Any) From RESP

Y

C RETURN +)

® RESP: A Variable Used to Pass the Response Code From the Receiver to the Transmitter

11657

Figure B.3, WTAK Subroutine

Page 199 read from a scan by OCR; it may hold reading errors

Page B-5 Detailed Flow Charts

SENDM Input: ® Message address e Size of message

Y

Internal: Reset BCC accumulator @ BCC accumulator ® Message pointer ® Message size counter SENDCTL Send DLE STX

BCC Link Data Done Include 9 Byte in BCC SENDETX Send SENDDATA DLE ETX BCC Send Link Data Byte

C RETURN )

11655

Figure B.4, SENDM Subroutine

Page 200 read from a scan by OCR; it may hold reading errors

Page B-6 Detailed Flow Charts

STARTTIME

An ImplementationDependant Routine that Schedules TIMEOUT to Be Executed at the Expiration of an Interval of Time (Typically 12 Character Times)

\ RETURN

11658

Figure B.5, STARTTIME Subroutine

STOPTIME

An Implementation-Dependent Routine to Cancel TIMEOUT

\

RETURN

11689

Figure B.6, STOPTIME Subroutine