Page 201
Page B-7
Detailed Flow Charts
< TIMEOUT )
WAKEUP
Wake Up the Process Sleeping at WTRESP (If Any)
RETURN e STARTTIME
Aborted By: ® STOPTIME
11660
Figure B.7, TIMEOUT Subroutine
Page 202
Page B-8 Detailed Flow Charts
GETMSG
SLEEP
Go to Sleep At WTMSG
Indivisible Zone
Lew oh ee ee ee
UNLINK Common:
Remove a « WIMSG
Message From
Queue e Output Queue Output: « A Message
Y RETURN
Boxed area above must be executed indivisibly, i.e., with the scheduler or interrupts disabled, depending on implementation.
11661
Figure B.8, GETMSG Subroutine
Page 203
Page B-9 Detailed Fiow Charts
SIGOK
Place Success Code in Message Control Block
SIGFAIL
Place Failed Code in Message Control BLock
' LINK
Place Message on RETURN Queue
J
WAKEUP-NET
Implementation-Dependent Procedure to Tell Network Layer that RETURN Queue Entry Has Been Made j
RETURN
11662
Figure B.9, SIGOK/SIGFAIL Subroutine
Page 204
Page B-10 Detailed Flow Charts
XMIT RCVE tt TXALLOC “ / t Not-In-Use x << UART Usage Signal \ \ \ Ye TXFREE XMIT RCVE
Since the tramsit side of the UART is shared by the transmit and receive processes, a mutual exclusion mechanism is used to gain sole access during transmission of each indivisible code sequence. The UART is like a small bridge, and the mutual exclusion mechanism is like two flagmen, one at each end of the bridge. If two heavy trucks (one called XMIT and one called RCVE) come to the bridge at the same time, the flagman on that side lets one through and makes the other wait. When the first truck has crossed the bridge, the flagman on the far side signals the first flagman, who then allows the second truck to cross. Ina similar manner, TXALLOC and TXFREE work together to ensure that XMIT and RCVE do not try to use the UART at the same time.
11664
Figure B.10, Sharing the Transmit Side of the UART
Page 205
Page B-11 Detailed Flow Charts
SENDCTL j
Input:
TXALLOC * Control Code
Allocate UART or Wait f
SEND
Transmit DLE j
SEND
Transmit Control Code y
TXFREE
Deallocate UART
'
RETURN
11663
Figure B.11, SENDCTL Subroutine
Page 206
Page B-12 Detailed Flow Charts
( SENDTX )
|
TXALLOC
Allocate UART or Wait d
SEND
Transmit DLE i
SEND
Transmit ETX j
Zero Out Any Previous Response Code at RESP d
SEND
Transmit BCC
TXFREE
Deallocate UART
RETURN
Input: e BCC
Common:
e RESP: The Response Code Variable
11665
Figure B.12, SENDTX Subroutine
Page 207
Page B-13 Detailed Flow Charts
( SEND )
Input: e Link Data Byte Common:
¢ TXWAIT: A Sleep Variable
Disable Processor Interrupts
| I l
Pe a aa mie HC d
Enable UART Transmit Interrupt
UART Transmitter
Empty 9
Yes
SLEEP
Suspend at TXWAIT d
Disable UART Transmit Interrupt y
Output Byte to UART d
Enable Processor Interrupts
[ | I
Indivisible Zone
J RETURN
NOTE: This figure assumes the use of a Z80 SIO
11669
Figure B.13, SEND Subroutine
Page 208
Page B-14 Detailed Flow Charts
( SENDDATA
L
Input: * Link Data Byte
TXALLOC
Allocate UART or Wait
SEND
Transmit Link Data Byte
SEND Is Data Yes Byte DLE Transmit a : Second DLE _ No TXFREE De-allocate UART
Y
( RETURN )
11666
Figure B.l14, SENDDATA Subroutine
Page 209
Page B-15 Detailed Flow Charts
TXALLOC
SLEEP
Wait at TXALWT Until UART is Free
Set IN-USE Flag
RETURN
Indivisible Zone
Common: e IN-USE Flag ® TXALWT: A Sleep Variable
11667
Figure B.15, TXALLOC Subroutine
Page 210
Page B-16 Detailed Flow Charts
( TXFREE }
Reset IN-USE Flag
Common:
® {N-USE Fiag © TXALWT: A Sleep Variable
Y WAKEUP
Continue Any Process at TXALWT
\
RETURN
11668
Figure B.16, TXFREE Subroutine