Page 211
Page B-17 Detailed Flow Charts
TRANSMIT INTERRUPT, NOTE: This figure assumes the use of a Z80 $10. { NOTE:UART transmit interrupt must be enabled and disabled without
WAKEUP affecting the current state of the receive and status interrupt enable flags.
Resume Process Sleeping At TXWAIT
1 t INTERRUPT RETURN
11670
Figure B.17, TRANSMIT INTERRUPT Subroutine
Page 212
Page B-18 Detailed Flow Charts
SLEEP
: j
An Implementation Dependent Routine to Suspend Own Process at a Sleep Variable Until Another Process Wakes This One Up
RETURN
WAKEUP
Uo
An Implementation Dependent Routine to Wake Up the Process at a Sleep Variable if Any is Sleeping There l ( RETURN )
Input: ® The Address of a Sleep Variable. Sleep Variables:
¢ Typically an address of a stack or
@ process or context save area.
A process can suspend itself and place its address in a sleep variable.
Subsequently another process can wake up the sleeping process by referring to sleep variable. When no process is sleeping at a sleep variable, a WAKEUP has no effect.
Input:
© The Address of a Sleep Variable
Figure B.18, SLEEP and WAKEUP Subroutines
Page 213
Page B-19 Detailed Flow Charts
NOTE: SLEEP and WAKEUP are always used in connection with some type of indivisible interprocess interlock. Indivisibly is achieved on many processors (e.g. - 2-80) by disabling processor interrupts. For this reason SLEEP and WAKEUP assume that interrupts are off when they are called. They will always return with interrupts off.
The interaction of SLEEP and WAKEUP:
When one process calls SLEEP, the result is a return froma WAKEUP by another process. When a process calls WAKEUP, the result is a return from a call to SLEEP by another process. An interrupt subroutine that calls WAKEUFP is viewed as a subroutine of the interrupted process.
PROCESS A
©
SLEEP el
©
OmxO)
In the example in figure B.18 Process B woke up Process A some time ago. Now, at 1, when A goes to sleep, actual execution resumes after the wakeup call in B at 3 and 4. Sometime later, process C (at an interrupt, for example) calls WAKEUP at 5. Execution flow proceeds to the instructions at 8 following the call to SLEEP in Process A. The next time A calls SLEEP, the WAKEUP call in C will terminate.
NOTE: This is not the only possible implementation of SLEEP and WAKEUP.
Another implementation would allow a process to call WAKEUP without losing immediate control of the processor. Context switching would be deferred until B itself executed a SLEEP.
PROCESS B
A Previous Wakeup
A third alternative would cause a context switch of a process performed a WAKEUP on a higher priority process. If a WAKEUP was performed on a lower priority process the context switch would be deferred until the first process went to SLEEP.
The first alternative is the result of implementing the driver totally at interrupt level. The third alternative would be used if the driver were implemented as tasks, under a multitasking operating system. Such an implementation might be easier, but would probably be limited to lowever baud rates
PROCESS C
Q. - =toe--=-@
NOTE: Sequence of processor execution is indicated by circled numbers.
WAKEUP
11672
Figure B.19, SLEEP and WAKEUP Interaction
Page 214
Page B-20
Detailed Flow Charts
Powerup: At powerup the Z-80 starts executing code at location 0. The powerup routine starts the XMIT and RCVE processes by executing a SPAWN. A SPAWN is very similar to a WAKEUP, except the corresponding SLEEP is imaginary, and is located ahead of the first instruction of the SPAWNed process.
POWERUP
SPAWN RCVE
SPAWN XMIT
Continue Initialization
11673
Figure B.20, POWERUP Routine
Page 215
Page B-21 Detailed Flow Charts
The Address of a Queue is
_ - the Address of its Root.
ROOT
MESSAGE CONTROL BLOCKS
FIRST
NEXT
MESSAGE a
MESSAGES
LAST
SIZE
STATUS
NOTE: Messages are added to the end of the queue and removed from the head.
NEXT
MESSAGE
Network Data Block
SIZE
STATUS
Q
MESSAGE
Network Data Block
SIZE
STATUS
Network Data Block
11674
Figure B.21, Message Queue
Page 216
Page B-22 Detailed Flow Charts
Input:
( UNLINK ) e Address of Queue Output:
¢ Message Control Block
An Implementation Dependent Routine that Removes a Message from a Queue f ( RETURN )
11675
Figure B.22, UNLINK Subroutine
Input: LINK * Address of Queue Message Block
An Implementation Dependent Routine that Places a Message onto a Queue
( RETURN )
11676
Figure B.23, LINK Subroutine
Page 217
Page B-23
Detailed Flow Charts
C=)
Y
Reset Buffer Flag: Set HEADER to Illegal Value
Y
GET BUFFER
Get a Buffer a
.
LAST = NAK
Variables:
LAST: Value of Last Response
HEADER: DST, SRC, CMD, STS and TNS from last message
BUFFER: Whether an Empty Buffer is Read
Receiver error flag
,
Reset Receiver Error Flag i
GET CODE
Get Next Input
Control
Code ?
SEND CTL
DLE ENQ Yes 9
XMSG
Transfer Message to Network Layer
Ignore Flag (0) ?
No
Save Response (ACK or NACK) in LAST
L
Transmit LAST
NOTE: XMSG Returns ACK, NACK, or 0 (for Ignored Message)
11654
Figure B.24, Receiver Routine for Full-Duplex Protocol
Page 218
Page B-24
Detailed Flow Charts
Yes
( XMSG )
j
GETBUF
Check Availability of Receive Buffer r
Clear CRC Accumulator
GETCODE
Get a Code
Link Data
No
Output Flag: e ACK if Message is OK e NAK if Message is in Error
¢ Oif Message is to be Ignored
?
Code =
Station No.
Buffer Available
Buffer
Overflow 2
Save Byte in Buffer
GETCODE
Get Next Code y
Return An Ignore Flag (0)
©
DLE ETX
No
Available ?
Yes
Did
Buffer Yes
Overflow ?
Yes
Message
Too Small
Compare Message with HEADER
Duplicate Message ?
Save New Header y
SENDNET
Send Link Data to Network Layer
GETBUF
Try to Get Another Buffer
Return an ACK
Return a NAK
11678
Figure B.25, XMSG Subroutine
Page 219
Page B-25 Detailed Flow Charts
Y
GETRAW
Get Byte From UART
BCC DLE No ? Add Data Bytes to BCC Yes
GETRAW
Return Byte and Data Flag
Get Byte From UART
Save ACK or NAK in RESP
WAKEUP
Resume XMIT if Sleeping at WTRESP
Return Byte and Control Flag GETRAW Get BCC Output: 1 ® BYTE, What Was Received BCC ® Control Data, Set if BYTE is a control character which was Include in Check preceded by a DLE
NOTE: BCC should Now Equal Zero.
Return EXT and Control Flag
11679
Figure B.26, GETCODE Subroutine
Page 220
Page B-26 Detailed Flow Charts
( GETRAW )
Disable Processor Interrupts
Set Receiver Error Flag
Discard Bad Data
Reset UART Error Flag
Yes
Enable UART Receive Interrupt
Byte in UART
Yes
SLEEP
Wait For RXD Interrupt at RXDWAIT
Disable UART Received Interrupt
Check Parity Framing, and Receiver Overrun
NOTE: This figure assumes the use of a Z80 Si0.
No
Get Byte From UART
J y
Enable Processor Interrupts
RETURN
11680
Figure B.27, GETRAW Subroutine