Page 201

Chapter 17 Report Generation

Table 17.C Industrial Terminal Control Codes Control Code Key Sequence

Function

[CTRL][P] [Column #][;] [Line #][A]

Positions the cursor at the specified column and line number [CTRL][P][A] positions the cursor at the top left corner of the screen.

[CTRL][P][F]

Moves the cursor one space to the right.

[CTRL][P][U]

Moves the cursor one line up in the same column.

[CTRL][P][5][C]

Turns cursor on.

[CTRL][P][4][C]

Turns cursor off.

[CTRL][P][5][G]

Turns on graphics capability.

[CTRL][P][4][G]

Turns off graphics capability.

[CTRL][P][5][P]

Turns Channel C outputs on.

[CTRL][P][4][P]

Turns Channel C outputs off.

[CTRL][I]

Horizontal tab that moves the cursor to the next preset 8th position.

[CTRL][K]

Clears the screen from cursor position to end of screen and moves the cursor to the top left corner of the screen.

Key Sequence

Attribute 1

[CTRL][P][0][T]

Attribute 0 = Normal Intensity

[CTRL][P][1][T]

Attribute 1 = Underline

[CTRL][P][2][T]

Attribute 2 = Intensify

[CTRL][P][3][T]

Attribute 3 = Blinking

[CTRL][P][4][T]

Attribute 4 = Reverse Video

1

Any three attributes can be used at one time using the following key sequence: [CTRL][P][Attribute #][;][Attribute #][;][Attribute #][T]

17-7

Page 202

Chapter 17 Report Generation

Table 17.D ASCII Control Codes Control Code 1

1 2 3

17-8

Display 2

ASCII Mnemonic

Name

CTRL 0

3

NU

NUL

NULL

CTRL A

3

SH

SOH

START OF HEADER

CTRL B

3

SX

STX

START OF TEXT

CTRL C

3

EX

ETX

END OF TEST

CTRL D

ET

EOT

END OF TRANSMISSION

CTRL E

EQ

ENQ

ENQUIRE

CTRL F

AK

ACK

ACKNOWLEDGE

CTRL G

BL

BEL

BELL

CTRL H

BS

BS

BACKSPACE

CTRL I

HT

HT

HORIZONTAL TAB

CTRL J

LF

LF

LINE FEED

CTRL K

VT

VT

VERTICAL TAB

CTRL L

FF

FF

FORM FEED

CTRL M

CR

CR

CARRIAGE RETURN

CTRL N

SO

SO

SHIFT OUT

CTRL O

SI

SI

SHIFT IN

CTRL P

DL

DLE

DATA LINK ESCAPE

CTRL Q

D1

DC1

DEVICE CONTROL 1

CTRL R

D2

DC2

DEVICE CONTROL 2

CRTL S

D3

DC3

DEVICE CONTROL 3

CTRL T

D4

DC4

DEVICE CONTROL 4

CTRL U

NK

NAK

NEGATIVE ACKNOWLEDGE

CTRL V

SY

SYN

SYNCHRONOUS IDLE

CTRL W

EB

ETB

END OF TRANSMISSION BLOCK

CTRL X

CN

CAN

CANCEL

CTRL Y

EM

EM

END OF MEDIUM

CTRL Z

SB

SUB

SUBSTITUTE

ESCAPE

EC

ESC

ESCAPE

CTRL,

FS

FS

FILE SEPARATOR

CTRL-

GS

GS

GROUP SEPARATOR

CTRL.

RS

RS

RECORD SEPARATOR

CTRL/

US

US

UNIT SEPARATOR

DELETE

DT

DEL

DELETE

Some ASCII control codes are generated using non standard keystrokes. Will be displayed when Control Code Display option is set ON in Alphanumeric mode, only. (Not in Report Generation mode). Invalid key in Report Generation mode.

Page 203

Chapter 17 Report Generation

The 1770-T3 industrial terminal screen size is 80 columns across by 24 lines down. An example message using graphic and alphanumeric characters is shown in Figure 17.5. Figure 17.5 Example Graphic/ Alphanumeric Message

Tank

Steam Inlet

Liquid

Inlet

Heater Coil Outlet Steam Return

Temperature Sensor PV SP

10261-I

The control code, [CTRL][P]<Column #>[;]<Line #<[A], should be used for cursor positioning to conserve memory when possible. For example, [CTRL][P][3][9][;][9][A] uses 3 words of memory, storing CRTL P in one byte and remaining characters in one byte each. If the cursor had been at column 0, and line 0, normal space, and line feed commands were used, it would have taken 24 words of memory to accomplish the same thing. Note that the column and line numbers begin at zero rather than one.

Report Generation Commands

The report generation function is entered by pressing [RECORD][DISPLAY] on the standard 1770-KCB alphanumeric keytop overlay. There are six report generation commands used to enter control words and to store, print, report and delete messages and to display an index of existing messages. Table 17.E summarizes these commands.

17-9

Page 204

Chapter 17 Report Generation

Table 17.E Report Generation Commands Command

Key Sequence

Description

Enter report generation function

[RECORD][DISPLAY] or Set baud rate, (Message Code Keys)

Puts industrial terminal into report generation function. Same (entered from a peripheral device).

Message store

[M][S][,](Message Number)[RETURN]

Stores message in processor memory. Use [ESC] to end message.

Message print

[M][P][,](Message Number) [RETURN]

Prints message exactly as entered.

Message report

[M][R][,](Message Number) [RETURN]

Prints message with current data table values or bit status.

Message delete

[M][D][,](Message Number) [RETURN]

Removes message from processor memory.

Message index

[M][I][RETURN]

Lists messages used and the number of words in each message.

Automatic report generation.

[SEARCH][4][0] or [M][R][RETURN]

Allows messages to be printed through program control.

Exit automatic report generation

[ESC] or [CANCEL COMMAND] 1

Terminates automatic report generation.

Exit report

[ESC] or [CANCEL COMMAND] 1

Returns to ladder diagram display. Terminates Report Generation Function.

1

[CANCEL COMMAND] can only be used if the function was entered by a command from a peripheral device.

Message Control Word File - MS, 0 Bits from eight consecutive user-selected words control the 64 additional messages (1770-FD series B and all its subsequent revisions). The eight message control words are determined by establishing a 2 -word message in data table, called message 0. Store Message 0 by using the following keystrokes: [M][S][,] 0 [RETURN]

17-10

Page 205

Chapter 17 Report Generation

A prompt, MESSAGE CONTROL WORDS (Y DIGITS REQUIRED): prints. (Y is the number of digits, 3, 4 or 5, of a word address for the selected data table size.) Enter the beginning word address of the message control word file. The industrial terminal calculates and displays the words in the message control word file. You can locate the message control word file in any unused data table area except processor work areas and input image table areas. If memory write protect is active, place the message control word file in the area of data table which can be changed (010-377). Once you choose the start address, the industrial terminal displays a table (Table 17.B) which shows the message numbers associates with each message control word. Message Store - MS Accessible only in the run/program mode, use this command to enter messages in memory. Access the message store command by pressing [M][S][,]<message number>[RETURN]. Valid message numbers are: 001-006 010-017 110-117 210-217 310-317 410-417 510-517 610-617 710-717 After pressing the key sequence, a READY FOR INPUT message appears. Any subsequent keys pressed then become part of the message. If you try to use a message number that already exists, the terminal displays MESSAGE ALREADY EXISTS. While entering a message, each key pressed, except [SHIFT][CTRL][ESC] or [RUB OUT], generates a code that is stored in one byte of memory. This includes ASCII and graphic characters as well as other keys such as [LINE FEED], [RETURN] or the [SPACE]. The [RUB OUT] key is not stored in memory. The [SHIFT] and [CTRL] keys and the next character in the sequence are stored together in one byte of memory. You can enter messages which when reported give the current value of a data table word or byte. The messages can report the on or off status of a data table bit by using the delimiters shown in Table 17.F.

17-11

Page 206

Chapter 17 Report Generation

Table 17.F Address Delimiters Delimiter Format

Explanation

Message Report Format

*XXX*

Enter 3-digit word address between delimiters.

Displays BCD value at assigned word address.

*XXX1* or *XXX0*

Enter 3-digit word address and a for upper byte or a for lower byte between delimiters.

Displays the octal value at assigned byte address.

*XXXXX*

Enter 5-digit bit address between delimiters.

Displays the ON or OFF status of the assigned bit address.

#XXX#

Enter 3,4 or 5-digit word address between delimiters.

Displays the BCD value at assigned word address.

!XXX!

Enter 3, 4, or 5-digit word address between delimiters.

Displays the 4-digit hex value at address.

&XXX1& &XXX0&

Enter 3, 4, or 5 digit word address and a upper byte or a for lower byte between delimiters.

Displays the octal value at the assigned byte address.

XXXXX

Enter 5, 6, or 7-digit bit address between delimiters.

Displays the ON or OFF status of the assigned bit address.

The desired delimiter is entered before and after the bit, byte, or word address. The delimiter is used to tell the industrial terminal to print the current status or value of the bit, byte, or word at the address. You can enter as many consecutive addresses as needed by sharing the same delimiter, such as *XXX*XXX*XXX*. The asterisk delimiters are used if the data table size is less than 512 words (not exceeding address 777). As an example, to report the on/off condition of a device SR6, during each cycle of machine operation. Delimiters are used to denote the output address 013/05, and the cycle counter accumulative value (stored at 030). The desired message, SR6 is (on or off) in cycle (xxx), is entered into memory with the following keystrokes: SR6 [space]IS[space]*01305*[space]IN[space]CYCLE[space]#030#[ESC] Terminate the message entry with the escape [ESC]key. Until [ESC] is pressed, all key strokes become part of the message. Pressing [ESC]again returns to the display to the ladder diagram. Pressing [CANCEL COMMAND] on the PLC-2 family keytop overlay also terminates message store, and the display returns to the ladder diagram if a peripheral device was used to enter report generation mode.

17-12

Page 207

Chapter 17 Report Generation

Message Print-MP Accessible in any mode, the message print command is used to print the contents of a message to verify it. This command is accessed by pressing [M][P][,]<message number>[RETURN]. Valid message numbers are listed under MESSAGE STORE. In the example, the message print command would give the following

MP, [RETURN]

The screen does not change. SR6 IS *01305* IN CYCLE #030#

The message print command is self-terminating. You can press [ESC] or [CANCEL COMMAND] to return to ladder diagram display. Message Report- MR Accessible in ay mode, the message report command prints a message with the current data table value or bit status that corresponds to an address between the delimiters. This command is accessed by pressing [M][R][,]<message number>[RETURN]. In the example, the message report command gives the following: (e.g. bit 013/05 is on and counter 030 accumulated value is 5)

MP,

The screen does not change.

[RETURN]

SR6 IS ON IN CYCLE 005

The message report command is self-terminating. When you press [ESC] or [CANCEL COMMAND], ladder diagram operation resumes.

17-13

Page 208

Chapter 17 Report Generation

Message Delete- MD Accessible only in rung/program mode, the message delete command is used to delete messages from memory. This command is accessed by pressing [M][D][,] <message number>[RETURN]. The message delete command cannot be terminated before completion. It self terminates after the message has been cleared from memory and a MESSAGE DELETED prompt is printed. you can enter [ESC] or [CANCEL COMMAND] to return to ladder diagram display. Message Index- MI Accessible in any mode, the message index command prints a list of the message numbers used and the amount of memory (in words) used for each message. In addition, the number of unused memory words available is listed. The message index command is accessed by pressing [M][I][RETURN]. This command cannot be terminated before completion. It self-terminates after the list is completed. To return to ladder diagram display,press [ESC] or [CANCEL COMMAND].

Example Programming

Using Latch and Unlatch instructions, you can easily program automatic report generation to handle multiple or simultaneous message requests. Simultaneous requests are handled by a priority system-the lower the message number, the higher the priority. Figure 17.6 shows a sample program that you can use to activate each message. When the event occurs which requests the message, the request bit is latched. After the event has occurred and the message is printed (the done bit comes on), the request bit is unlatched. This technique also ensures the requested message gets printed once per request. Figure 17.6 Example Program to Request a Message. Event

Done Event

Chapter Summary

17-14

Request L L Request

We showed you how to generate messages that contain ASCII, graphic characters, or variable data. The next chapter shows how to use several special programming technique.

Page 209

Chapter

18

Programming Techniques

Chapter Objectives

This chapter describes several programming techniques you can use for: one-shot programming automatic re-start cascading timers temperature conversions program control bottle filling application

One-Shot

The one-shot programming technique sets a bit for one program scan only. There are two types of one-shots: leading edge trailing edge Leading Edge One-Shot A leading edge one-shot sets a bit for one scan when its input condition has made a false-to-true transition. The false-to-true transition represents the leading edge of the input pulse (Figure 18.1). Figure 18.1 Leading Edge One Shot 112

011

253

04 253

14

04 253

00 011 L 14 011 U 14 010

00

00

00 112

18-1

Page 210

Chapter 18 Programming Techniques

When bit 112/04 makes a false-to-true transition, the one-shot bit (bit 253/00) is set on for one scan. The length of time bit 112/04 remains on does not affect the one-shot bit due to the next two rungs. Bit 011/14 is latched when bit 112/04 is set or bit 011/14 is unlatched when 112/04 is reset. During the next scan, either set of conditions prevents bit 253/00 from being set. The one-shot bit is set for another scan only when bit 112/04 makes a true-to-false and then a false-to-true transition. Trailing Edge One-Shot A trailing edge one-shot sets a bit for one scan when its input condition has made a true-to-false transition. The true-to-false transition represents the trailing edge of the input pulse. Figure 18.2 shows programming for a trailing edge one-shot. Figure 18.2 Trailing Edge One-Shot 112 04 112 04 253

011 14

011 L 00 253

00 253

00 011 U 14 010

00

00

When bit 112/04 is set, bit 011/14 is latched. As soon as bit 112/04 makes a true-to-false transition,the one-shot bit (bit 253/00 is set and bit 011/14 is unlatched. Bit 153/00 remains on for only one scan. The input bit 112/04 makes a false-to-true transition then a true-to-false transition to set the one-shot bit for another scan.

Automatic Restart

18-2

You can control start-up automatically when using the EEPROM memory module. Anytime that an EEPROM to CMOS RAM memory transfer occurs, bit 02701 in the data table is set by the processor. The program must reset this bit. This allows the data table to be updated automatically to the indicated machine position.