Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of 1772 Mini PLC-2/05 Processor (Cat. No. 1772-LS, LSP) Programming and Operations Manual

Manual · Allen-Bradley

1772 Mini PLC-2/05 Processor (Cat. No. 1772-LS, LSP) Programming and Operations Manual

Manual289 pagesPDF 1.4 MB

Programming and operations manual for the Allen-Bradley Mini PLC-2/05 processor, catalog numbers 1772-LS and 1772-LSP.

Download the PDF1.4 MB

Covers · 1 model

The models it covers

Summary

What is in it

This Allen-Bradley manual tells you how to program and operate the Mini PLC-2/05 processor (1772-LS and 1772-LSP). It covers the hardware, memory organization and scan theory, then the instruction set: relay-type and program control instructions, timers and counters, data manipulation, math, file instructions, sequencers, jumps and subroutines, block transfer and selectable timed interrupt. Later parts cover program editing, report generation, programming techniques and troubleshooting, with a glossary and quick reference.

Its parts

  1. Before You Begin
  2. An Introduction to Programmable Controllers
  3. Hardware
  4. Memory Organization
  5. Scan Theory
  6. Relay-type Instructions
  7. Program Control Instructions
  8. Timers and Counters
  9. Data Manipulation Instructions
  10. Math Instructions
  11. Data Transfer File Instructions
  12. Sequencers
  13. Jump Instructions and Subroutine
  14. Block Transfer
  15. Selectable Timed Interrupt

From the manual

Key facts from this manual

Each line names its page in the PDF.

Allen-Bradley programming and operations manual for the Mini-PLC-2/05 processor, covering both the 1772-LS and the 1772-LSP (the version with a built-in power supply). It describes the hardware, memory organization, the instruction set, program editing, report generation and program troubleshooting with the 1770-T3 industrial terminal.

Read for this summary: pages 1 to 3, 10 to 14, 27 to 38 and 222 to 230 of 289.

Type
Mini-PLC-2/05 processor with built-in power supply, 120V AC input p. 30, 31
Memory
3K CMOS RAM; data table up to 2944 words (23 blocks); 488 timers p. 27
I/O capacity
Up to 16 I/O modules in the I/O chassis p. 27
Power input
120V AC on terminals L1, N and GND; 1.0 amp fuse p. 31
Battery
Size AA 3.6V lithium, 1.785 amp hr; holds memory up to two years p. 32
EEPROM module
Optional 1772-MJ, 3K non-volatile program backup p. 29, 38
Programming port
15 pin INTFC socket for 1770-T3 or 1784-T50 terminal, 1770-RG, 1770-T11, 1772-KG or 1771-KA p. 29
Cables
1772-TC program panel cable (1784-T50: 1772-TC or 1784-CP2); Data Highway cables 1771-CN, -CO or -CR p. 29
Software
1784-T50 needs PLC-2 6200 software: 6201-PLC2, 6203-PLC2, 6211-PLC2 or 6213-PLC2 p. 29
Keytop overlay
PLC-2 Family Keytop Overlay 1770-KCB; select mode 11 on the 1770-T3 p. 34, 36
Indicators
PROC RUN/FAULT (red/green) and P/S ACTIVE (green) LEDs p. 29, 30
Chassis switches
Switch 8: memory protect; switches 6 and 7: EEPROM to RAM transfer at power-up p. 31
Paralleling
1772-CT cable parallels with a 1772-P3 or 1771-P4 power supply p. 38
Messages
70 stored messages with the 1770-T3; 198 with the 1770-RG module p. 27

What this manual walks you through

  • Connecting the industrial terminal to the processor p. 33, 34, 36
  • Selecting run/program, remote test and remote program modes p. 37
  • Setting the memory protect and power-up switches p. 31
  • Programming timers, counters, math, file, sequencer and block transfer instructions p. 10, 11
  • Diagnosing and fixing run time errors p. 222, 223
  • Monitoring and changing data table bits p. 223, 224
  • Recording a bit's on/off history with the contact histogram p. 224, 225
  • Forcing inputs and outputs on or off p. 226, 227
  • Testing part of a program with a temporary end instruction p. 228, 229
  • Clearing an ERR message from an illegal opcode p. 229, 230

Good to know

  • Series A/Revision A of the 1770-T3 terminal does not work with the memory protect feature. p. 31
  • Set the chassis switches with a ball point pen, not a lead pencil, whose tip can jam the switch. p. 31
  • In run/program mode a run time error gives no indication; in remote test the processor halts. p. 222
  • In remote test mode outputs stay off even when forced on. p. 226
  • All forces clear when the terminal is disconnected, either unit loses ac power, or MODE SELECT is pressed. p. 227

Questions this manual answers

What battery does the Allen-Bradley 1772-LSP use?

A size AA 3.6V lithium battery (1.785 amp hr) in a holder at the rear; it supports memory for up to two years. p. 32

What is the difference between the 1772-LS and the 1772-LSP?

The 1772-LSP has all the features of the LS plus a power supply section with a P/S ACTIVE LED, power switch, fuse and AC terminal strip. p. 30, 31

Which cable connects a 1770-T3 terminal to the Mini-PLC-2/05?

The 1772-TC PLC-2 Program Panel Interconnect Cable, from channel A on the terminal to the INTFC socket on the processor. p. 33

How much memory does the Mini-PLC-2/05 have?

3K of CMOS RAM; the optional 1772-MJ EEPROM module gives a 3K non-volatile backup. p. 27, 38

What does RUN-TIME ERROR on the industrial terminal mean?

The program contains an instruction the processor cannot carry out, such as a bad jump or label; press 11 to show it, then edit the program and restart. p. 222, 223

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1772-6.8.6, 1772 Mini PLC-2/05 Processor, Programming and Operations Manual1
    1. 1772-6.8.6, Front Cover1
    2. 1772-6.8.6, Inside Cover2
    3. 1772-6.8.6, Summary of Changes3
    4. 1772-6.8.6, Section Dividers4
    5. 1772-6.8.6, Table of Contents10
    6. 1772-6.8.6, 1 - Before You Begin12
    7. 1772-6.8.6, 2 - An Introduction to Programmable Controllers15
    8. 1772-6.8.6, 3 - Hardware27
    9. 1772-6.8.6, 4 - Memory Organization39
    10. 1772-6.8.6, 5 - Scan Theory48
    11. 1772-6.8.6, 6 - Relay-type Instructions53
    12. 1772-6.8.6, 7 - Program Control Instructions62
    13. 1772-6.8.6, 8 - Timers and Counters68
    14. 1772-6.8.6, 9 - Data Manipulation Instructions76
    15. 1772-6.8.6, 10 - Math Instructions89
    16. 1772-6.8.6, 11 - Data Transfer File Instructions110
    17. 1772-6.8.6, 12 - Sequencers127
    18. 1772-6.8.6, 13 - Jump Instructions and Subroutine149
    19. 1772-6.8.6, 14 - Block Transfer156
    20. 1772-6.8.6, 15 - Selectable Timed Interrupt175
    21. 1772-6.8.6, 16 - Program Editing178
    22. 1772-6.8.6, 17 - Report Generation195
    23. 1772-6.8.6, 18 - Programming Techniques209
    24. 1772-6.8.6, 19 - Program Troubleshooting222
    25. 1772-6.8.6, A - Number Systems231
    26. 1772-6.8.6, B - Glossary237
    27. 1772-6.8.6, C - Quick Reference257
    28. 1772-6.8.6, Index282
    29. 1772-6.8.6, Back Cover289

From the PDF’s own bookmarks.

The whole text · 29 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Pages 121 to 130121-130
  14. Pages 131 to 140131-140
  15. Pages 141 to 150141-150
  16. Pages 151 to 160151-160
  17. Pages 161 to 170161-170
  18. Pages 171 to 180171-180
  19. Pages 181 to 190181-190
  20. Pages 191 to 200191-200
  21. Pages 201 to 210201-210
  22. Pages 211 to 220211-220
  23. Pages 221 to 230221-230
  24. Pages 231 to 240231-240
  25. Pages 241 to 250241-250
  26. Pages 251 to 260251-260
  27. Pages 261 to 270261-270
  28. Pages 271 to 280271-280
  29. Pages 281 to 289281-289

The file

Revision and size

Part no.1772-6.8.6
RevisionMay 1994
PublisherAllen-Bradley
Pages289
PDF1.4 MB
TextText from the PDF itself.
1772-6.8.6

The first pages · 3 of 289

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 289
Page 2
Page 2of 289
Page 3
Page 3of 289

More documents · 1

For the same models