Page 271

Appendix C Quick Reference

Table C.N Block Transfer Instructions Key Sequence BLOCK XFER 0

1770-T3 Display Block Xfer Write Data Addr: Module Addr:

030 100

Block Length:

001

File: BLOCK XFER 1

110- 110 Block Xfer Write

Data Addr: Module Addr:

030 100

Block Length:

001

File: BLOCK XFER 0 BLOCK XFER 1

110- 110

Instruction Notes 010 EN 06 110 DN 06 010 EN 06

Output instruction. Block length depends on kind of module. Entire file transferred in one scan. Done bit remains on for one scan after valid transfer.

Data read from I/O module must be buffered. Uses two words of user program for each instruction

110 DN 06

Enter both instruction blocks for bidirectional block transfer.

Set block lengths equal or to default value for module. Same module address used for read and write instruction. Enable read and write instructions in same scan. Order of operation determined by the module. See the module user's manual.

NOTE: Numbers shown are default values. Numbers in shaded areas must be replaced by user-entered values. The number of default address digits initially displayed (3 or 4) will depend on the size of the data table. To access the Data Monitor Display, enter all instruction parameters. Press key sequence: [DISPLAY][0] for the binary monitor mode; [DISPLAY][1] for the hexadecimal monitor mode.

This Value:

Stores the:

Data Address

First possible address in the timer/counter accumulated value area of the data table

Module Address

RGS for R = rack, G = module, S = slot number

Block Length

Number of words to be transferred (enter 00 for default value or for 64 words)

File

Address of the first word of the file

Enable bit -(EN)-

Automatically entered from the module address Set on when the rung containing the instruction is true

Done bit -(DN)-

Automatically entered from the module address Remains on for 1 program scan following successful transfer

C-15

Page 272

Appendix C Quick Reference

Table C.O Editing Functions 1 Function

Key Sequence

Mode

[INSERT] (Instruction) (Address) or [INSERT][ ] (Instruction) (Address)

Program

Removing a condition instruction

[REMOVE] (instruction)

Program

Position the cursor on the instruction to be removed and press the key sequence.

Inserting a rung

[INSERT] [RUNG]

Program

Position the cursor on any instruction in the preceding rung and press the key sequence. Enter instructions and complete the rung.

Removing a rung

[REMOVE] RUNG]

Program

Position the cursor anywhere on the rung to be removed and press the key sequence.

Inserting a condition instruction

Description Position the cursor on the instruction that will precede the instruction to be inserted. Then press key sequence. Position the cursor on the instruction that will follow the instruction to be inserted. Then press key sequence.

IMPORTANT: Only addresses corresponding to output energize, latch and unlatch instructions are cleared to zero. Change data of a word or block instruction

[INSERT] (Data)

Program

Position the cursor on the word or block instruction whose data is to be changed. Press the key sequence.

Change the address of a word or block instruction

[INSERT] (first Digit) [←] (Address)

Program

Position the cursor on a word or block instruction with data and press [INSERT]. Enter the first digit of the first data value of the instruction. Then use the [ ] and [ ]key as needed to cursor up to the word address. Enter the appropriate digits of the word address.

Online programming

[SEARCH] [5][2]

Replace an instruction or Change address of an instruction without data

[Instruction] (Address)

Program

Position the cursor on the instruction to be replace or whose address is to be changed. Press the desired instruction key (or key sequence) and the required address(es).

Online Data Change

[SEARCH] [5][1] (Data) [RECORD]

Run/Progra m

Position the cursor on the word or block instruction whose data is to be changed. Press sequence. Cursor keys can be used.

Initiates online programming.

Press [RECORD] to enter the new data into memory. To terminate online data change.

[CANCEL COMMAND] All editing functions

[CANCEL COMMAND]

Program

Aborts the operation at the current cursor position.

Run/Progra m

These functions can also be used during online programming. 1

C-16

When bit address exceeds 5 digits, press the [EXPAND ADDR] key before entering address and enter a leading zero if necessary.

Page 273

Appendix C Quick Reference

Table C.P Search Functions Function

Key Sequence

Mode

Locate first rung program

[SEARCH][↑]

Any

Positions cursor on the first instruction of the program.

Locate last rung program area

[SEARCH][↓]

Any

Positions cursor on the temporary end instruction, subroutine area boundary, or the end statement depending on the cursor's location. Press key sequence again to move to the next boundary.

Locate first instruction of current rung.

[SEARCH] [←]

Remote Prog

Position cursor on first instruction of the current rung.

Move cursor off screen

[SEARCH][←]

Remote Test Run/Program

Moves cursor off screen to left.

Locate output instruction of current rung

[SEARCH][→]

Any

Position cursor on the output instruction of the current rung.

Locate rung without an output instruction

[SHIFT] [SEARCH]

Any

Locates any rung left incomplete due to an interruption in programming.

Locate specific instruction

[SEARCH] [Instruction key] (Address)

Any

Locates instruction searched for. Press [SEARCH] to locate the next occurrence of instruction.

Locate specific word address

[SEARCH] (address)

Any

Locates this address in the program (excluding -| |- and -| / |- instructions and addresses in files). Press [SEARCH] to locate th next occurrence of this address. 1

Single rung display

[SEARCH] [DISPLAY]

Any

Displays the first rung of a multiple rung display by itself. Press key sequence again to view multiple rungs.

Print

[SEARCH] [4] [3]

Any

Prints single rung.

Print

[SEARCH] [4] [4]

Any

Prints ladder diagram dump.

Print

[SEARCH] [4] [5]

Remote Prog

Prints total memory dump.

Print

[SEARCH] [5] [0]

Any

Prints first 20 lines of data table configuration.

Print

[SEARCH] [5] [3]

Any

Prints first 20 lines of bit manipulation.

Print

[SEARCH] [5] [4]

Any

Prints first 20 lines of memory layout display.

Program controls outputs

[SEARCH] [5][9][0]

Run/Program

Places the processor in run/program mode.

Program executes outputs disabled

[SEARCH] [5][9][1]

Remote Test

Places the processor in remote test mode.

Processor awaits commands

[SEARCH] [5][9][2]

Remote Program

Places the processor in remote program mode.

1

Description

Enter leading zeros when bit address exceeds 5 digits or word address exceeds 3 digits.

C-17

Page 274

Appendix C Quick Reference

Table C.Q Clear Memory Functions Function

Key Sequence

Mode

[CLEAR MEMORY] [7][7] (Start Address) (End Address) [CLEAR MEMORY]

Program

User program clear

[CLEAR MEMORY] [8][8]

Program

Position the cursor at the desired location in the program. Clears user program from the position of the cursor to the first boundary: i.e. temporary end, subroutine area, or end statement. Does not clear data table or messages.

Partial memory clear

[CLEAR MEMORY] [8][8]

Program

Clears user program and messages from position of the cursor. Does not clear data table.

Total memory clear

[CLEAR MEMORY] [9][9]

Program

Position the cursor on the first instruction of the program. Clears user program and messages. Does not clear data table, unless the cursor is on the first program instruction.

Data table clear

Description Displays a start address and an end address field. Start and end word addresses determine boundaries for data table clearing. Clears the data table within and including addressed boundaries.

NOTE: When memory write protect is active, memory cannot be cleared except for data table addresses 010-177 with a programmed EPROM installed.

C-18

Page 275

Appendix C Quick Reference

Table C.R Help Directories Function

Key Sequence

Mode

Description

Help directory

[HELP]

Any

Displays a list of the keys that are used with the [HELP] key to obtain further directories.

Control function directory

[SEARCH] [HELP]

Any

Provides a list of all control functions that us the [SEARCH] key.

Record function directory

[RECORD] [HELP]

Any

Provides a list of functions that use the [RECORD] key.

Clear memory directory

[CLEAR MEMORY] [HELP]

Program

Data monitor directory

[DISPLAY] [HELP]

Any

Provides the choice of data monitor display accessed by the [DISPLAY] key.

File instruction directory

[FILE][HELP]

Any

Provides a list of all instructions that use the [FILE] key.

Sequencer directory

[SEQ][HELP]

Any

Provides a list of all instructions that use the instruction [SEQ] key.

Block transfer directory

[BLOCK XFER]

Any

Provides a list of all instructions that use the [BLOCK XFER] key.

[CANCEL COMMAND]

Any

To terminate.

All directories

Provides a list of all functions that use the [CLEAR MEMORY] key.

C-19

Page 276

Appendix C Quick Reference

Table C.S Report Generation Commands Command

Key Sequence

Enter report generation function

[RECORD[[DISPLAY] or Set baud rate, (Message Code Keys)

Puts industrial terminal into report generation function.

[M][S][,](Message Number) [RETURN]

Stores message in processor memory.

Message print

[M][P][,](Message Number) [RETURN]

Prints message exactly as entered.

Message report

[M][R][,](Message Number) [RETURN]

Prints message with current data values or bit status.

Message delete

[M][D][,](Message Number) [RETURN]

Removes message from processor memory.

Message index

[M][I][RETURN]

Lists messages used and the number of words in each message.

Automatic report generation

[SEARCH][4][0] or [M][R][RETURN]

Allows messages to be printed through program control.

Message store

Description

Same (entered from a peripheral device). Use [ESC] to end message.

Same (entered from a peripheral device). Exit automatic report generation

[ESC] or [CANCEL COMMAND] 1

Terminates automatic report generation.

Exit report

[ESC] or [CANCEL COMMAND] 1

Returns to ladder diagram display. Terminates Report Generation Function.

1

C-20

[CANCEL COMMAND] can only be used if the function was entered by a command from a peripheral device.

Page 277

Appendix C Quick Reference

Table C.T Address Delimiters Delimiter Format

Explanation

Message Report Format

*XXX*

Enter 3-digit word address between delimiters.

Displays BCD value at assigned word address.

*XXX1* or *XXX0*

Enter 3-digit word address and a for upper byte or a for lower byte between delimiters.

Displays the octal value at assigned byte address.

*XXXXX*

Enter 5-digit bit address between delimiters.

Displays the ON or OFF status of the assigned bit address.

#XXX#

Enter 3,4 or 5-digit word address Displays the 4-digit hex value between delimiters. at address.

&XXX1& &XXX0&

Enter 3,4 or 5-digit word address and a for upper byte or a for lower byte between delimiters.

Displays the octal value at the assigned byte address.

XXXXX

Enter 5,6 or 7-digit bit address between delimiters.

Displays the ON or OFF status of the assigned bit address.

C-21

Page 278

Appendix C Quick Reference

Table C.U Alphanumeric/Graphic Key Definitions Key

C-22

Function

[LINE FEED]

Moves the cursor down one line in the same column.

[RETURN]

Returns the cursor to the beginning of the next line.

[RUB OUT]

Deletes the last character or control code that was entered.

[REPT LOCK]

Allows the next character that is pressed to be repeated continuously until [REPT LOCK] is pressed again.

[SHIFT]

Allows the next key pressed to be a shift character.

[SHIFT LOCK]

Allows all subsequent keys pressed to be shift characters until [SHIFT] or [SHIFT LOCK] is pressed.

[CTRL]

Used as part of a key sequence to generate a control code.

[ESC]

Terminates the present function.

[MODE SELECT]

Terminates all functions and returns the mode select display to the screen.

Blank Yellow Keys

Space keys. Move the cursor one position to the right.

Page 279

Appendix C Quick Reference

Table C.V Industrial Terminal Control Codes Control Code Key Sequence

Function

[CTRL][P] [Column#][;] [Line#][A]

Positions the cursor at the specified column and line number. [CTRL][P][A] will position the cursor at the top left corner of the screen.

[CTRL][P][F]

Moves the cursor one space to the right.

[CTRL][P][U]

Moves the cursor one line up in the same column.

[CTRL][P][5][C]

Turns cursor on.

[CTRL][P][4][C]

Turns cursor off.

[CTRL][P][5][G]

Turns on graphics capability.

[CTRL][P][4][G]

Turns off graphics capability.

[CTRL][P][5][P]

Turns Channel C outputs on.

[CTRL][P][4][P]

Turns Channel C output off.

[CTRL][1]

Horizontal tab that moves the cursor to the next preset 8th position.

[CTRL][K]

Clears the screen from cursor position to end of screen and moves the cursor to the top left corner of the screen.

Key Sequence

Attribute 1

[CTRL][P][0][T]

Attribute 0 = Normal Intensity

[CTRL][P][1][T]

Attribute 1 = Underline

[CTRL][P][2][T]

Attribute 2 = Intensify

[CTRL][P][3][T]

Attribute 3 = Blinking

[CTRL][P][4][T]

Attribute 4 = Reverse Video

1

Any three attributes can be used at one time using the following key sequence: [CTRL][P][Attribute #][;][Attribute #][;][Attribute #][T]

C-23

Page 280

Appendix C Quick Reference

Table C.W Contract Histogram Functions Function

Key Sequence

Mode

Continuous contact histogram

[SEARCH][6] (Bit Address) [DISPLAY]

Any

[SEARCH][7] (Bit Address) [DISPLAY] [DISPLAY]

Any

Paged Contact

Either

C-24

[CANCEL COMMAND]

Description Provides a continuous display of the on/off history of the addressed bit in hours, minutes and seconds. Can obtain a hardcopy printout of contact histogram by connecting a peripheral device to Channel C and selecting proper baud rate before indicated key sequence. Displays 11 lines on/off history of the addressed bit in hours, minutes and seconds. Displays the next 11 lines of contact histogram. Can obtain a hard copy printout of contact histogram by connecting peripheral device to Channel C and selecting proper baud rate. To terminate.