Mini-PLC-2 Family Programmable Controllers Quick Start for Experienced Users, pages 1 to 9

Pages 1 to 9 of 17

The original document is the PDF (326 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 1772-LX / LXP and Allen-Bradley 1772-LZP

Page 1 read from a scan by OCR; it may hold reading errors

wy

Allen-Bradley

Mini-PLC-2 Family r Programmable Qu ICK Start

Controllers for Experienced Users product icon

Page 2

Important User Information

Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards. The illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication. Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation, and Maintenance of Solid-State Control (available from your local Allen-Bradley office), describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication. Reproduction of the contents of this copyrighted publication, in whole or in part, without written permission of Allen-Bradley Company, Inc., is prohibited. Throughout this manual we use notes to make you aware of safety considerations:

!

ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage or economic loss.

Attention statements help you to: • identify a hazard • avoid the hazard • recognize the consequences Important:

Identifies information that is critical for successful application and understanding of the product.

Page 3

Table of Contents

Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

P-1

Using this Quick Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . What You Need to Do . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Components used in this Quick Start . . . . . . . . . . . . . . . . If You Need Help ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

P-1 P-1 P-2 P-2

Configure and Ground I/O Chassis . . . . . . . . . . . . . . . . . .

1-1

Configure I/O Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ground I/O Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1-1 1-2

Install I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1

Install Field Wiring Arms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1 2-1

Install Backup Battery and Memory Module . . . . . . . . . . . .

3-1

Install Backup Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install Memory Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3-1 3-1

Install Processor and Power Supply . . . . . . . . . . . . . . . . .

4-1

Install Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4-1 4-1

Connect Power to the Processor or Power Supply . . . . . . .

5-1

Connect Power to Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connect Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5-1 5-1

Connect Programming Terminal . . . . . . . . . . . . . . . . . . . .

6-1

Connect to a Personal Computer . . . . . . . . . . . . . . . . . . . . . . . . . Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-2 -1

Page 4

Preface

Preface Using this Quick Start

This quick start is designed to help you quickly install and connect a basic mini-PLC-2 family programmable controller system. Use this guide if you are knowledgeable about mini-PLC-2 family products but may not have used one or more of the products for a period of time. The information we provide is geared to “jog your memory.”

What You Need to Do step 1 Install I/O chassis a Configure I/O chassis (page 1-1) I/O chassis b Ground (page 1-2)

For more information...

For more information, see the Mini-PLC-2/02, -2/16, -2/17 Processor User Manual, publication 1772-6.5.8.

step 2 Install I/O field wiring arms a Install (page 2-1) I/O modules b Install (page 2-1)

step 3 Install Memory Module backup battery a Install (page 3-1) memory module b Install (page 3-1)

step 4

Install Processor and Power Supply processor a Install (page 4-1) power supply b Install (page 4-1)

Publication 1772-10.2 - March 1996

Page 5

P–2

Preface step 5 a b step 6

Make power connections Connect power to processor (page 5-1) Connect power supply (page 5-1) Connect programming terminaal (page 6-1)

System Components used in this Quick Start

If You Need Help ... A-B

Publication 1772-10.2 - March 1996

Product name:

Catalog number:

I/O chassis

1771-A1B, -A2B, -A3B, -A3B1, -A4B, -A1, -A2, -A4 power supply

1771-P3, -P4, -P5, -P7

I/O modules

1771 product line programming terminal

1770-T3 series C, IBM PC-compatible computer using 6200 series or AI PLC-2 programming software processors

1772-LZ, -LZP, -LX, -LXP, -LW, -LWP, -LS, -LSP memory modules

1775-MJ, 1772-MJ

If you need additional assistance in installing or connecting your mini-PLC-2 family programmable controller system, call 1-800-9-NEWLIT to order one of the publications suggested below or contact your Allen-Bradley service representative. Publication title:

Publication number:

Mini-PLC-2/15 Programmable Controllers Assembly and Installation Manual

1772-6.6.1

Mini-PLC-2 Programmable Controllers Assembly and Installation Manual

1772-6.6.3

Mini-PLC-2/05 Programmable Controllers Assembly and Installation Manual

1772-6.6.6

Mini-PLC-2/05 Programmable Controllers Assembly and Installation Manual Documentation Update

1772-6.6.6-DU1

Mini-PLC-2/02, -2/16, -2/17, Processor User Manual

1772-6.5.8

1772-Mini-PLC-2/05 Processor Programming and Operations Manual

1772-6.8.6

Mini-PLC-2 Programmable Controllers Programming and Operations Manual

1772-6.8.4

Mini-PLC-2/15 Programmable Controllers Programming and Operations Manual

1772-6.8.2

Page 6

Step

1

Configure and Ground I/O Chassis Configure I/O Chassis a Set the backplane switches.

See the installation manual for your particular processor for specific switch-setting information.

Switch Group Assembly b Install keying bands. Keying Bands

Backplane Socket

See the appropriate product data for the module you are installing to determine the proper keying positions for each module.

24 68 10 12 14 16 18 20 22 24 26 28 30 32 34 36

Insert two keying bands in the top backplane connectors of the I/O chassis. For the processor, place one keying band in the left-most slot between pins 46 and 48 and 54 and 56.

10170-I

Publication 1772-10.2 - March 1996

Page 7

1–2

Configure and Ground I/O Chassis

Ground I/O Chassis enclosure wall grounding electrode conductor ground bus to grounding electrode system equipment grounding conductor

PLC-2/30 processor

8 AWG

1771-P7 power supply

I/O chassis wall

14 AWG mini-processor with built-in power supply ground lug power supply module nut star washer ground lug

14 AWG

ATTENTION: If you use this grounding configuration, do not make connections to EQUIP GND on the power supply terminal strips or ground loops could result.

Publication 1772-10.2 - March 1996

Page 8

Step

2

Install I/O Modules Install Field Wiring Arms wiring arm horizontal bar

C-shaped bracket remove install

Install I/O Modules locking bar

I/O module card guides corresponding keyed slot

Publication 1772-10.2 - March 1996

Page 9

2–2

Install I/O Modules

For more information...

a

Specific wiring information for each type of I/O module is contained in the product data publication for that specific module. Therefore, refer to the appropriate product data publication when you follow these steps.

Install each I/O module. Use the locking latch to secure the module in place.

Module Locking Modules Guides Latch

32 I/O

Module Extraction Tab Wiring Arm Locking Tab Field Wiring Arm I/O Module b

Snap the field wiring arms for each I/O module onto the horizontal bar of the I/O chassis and connect it to the module.

c

Remove the terminal cover from each wiring arm and connect the wires between the I/O devices and the wiring arm terminals.

d

Connect the power and ground wires.

e

Use tie wraps to gather the wires at each wiring arm, then bundle the wires so the arms can pivot freely.

f

Replace the terminal covers and label the terminal status indicators appropriately.

Publication 1772-10.2 - March 1996