Filed in the catalog under the Allen-Bradley 1783-US08T

Page 1

Technical Data

Stratix Ethernet Device Specifications Stratix® 2000 Switches (1783-US), Stratix 2500 Switches (1783-LMS), Stratix 6000 Switches (1783-EMS) Stratix 5400 Switches (1783-HMS), Stratix 5410 Switches (1783-IMS), Stratix 5700 Switches (1783-BMS) ArmorStratix™ 5700 Switches (1783-ZMS), Stratix 8000 and 8300 Switches (1783-MS, 1783-RMS, 1783-MX) Stratix 5100 Wireless Access Point/Workgroup Bridge (1783-WAP), Stratix 5900 Services Router (1783-SR) Stratix 5950 Security Appliance (1783-SAD), Embedded Switch Technology (1783-ETAP), Configurable NAT Router (1783-NATR) Topic

Page

Summary of Changes

2

Additional Resources

2

Stratix 2000 Ethernet Unmanaged Switches - Series B

3

Stratix 2000 Ethernet Unmanaged Switches - Series A

10

Stratix 2500 Ethernet Lightly Managed Switches

17

Stratix 5400 Ethernet Managed Switches

21

Stratix 5410 Ethernet Managed Switches

25

Stratix 5700 Ethernet Managed Switches

31

ArmorStratix 5700 Ethernet Managed Switches

41

Stratix 6000 Ethernet Managed Switches

46

Stratix 8000 and Stratix 8300 Ethernet Managed Switches

49

Stratix 5100 Wireless Access Point/Workgroup Bridge

56

Stratix 5900 Services Router

58

Stratix 5950 Security Appliance

60

Embedded Switch Technology

63

Configurable NAT Router

66

Accessories

69

Page 2

Stratix Ethernet Device Specifications

Summary of Changes This publication contains new and updated information as indicated in the following table. Topic

Page

Added footnotes about using an attenuator to 1783-SFP1GZX and 1783-SFP1GEXE SFP modules

69

Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource

Description

Configurable NAT Router User Manual, publication 1783-UM008

Describes how to install, configure, and troubleshoot the NAT router.

EtherNet/IP Industrial Protocol White Paper, publication ENET-WP001

Describes how to implement services and data objects on a TCP/UDP/IP based Ethernet network.

Stratix Managed Switches User Manual, publication 1783-UM007

Describes how to configure and troubleshoot Stratix 5400, 5410, 5700, 8000, 8300, and ArmorStratix 5700 switches.

Stratix 2000 Ethernet Unmanaged Switches Installation Instructions, publication 1783-IN003 Describes how to install Stratix 2000 switches. Stratix 2000 Ethernet Unmanaged Switches User Manual, publication 1783-UM011

Describes how to use DIP switches and status indicators on Stratix 2000 switches.

Stratix 2500 Lightly Managed Switches Installation Instructions, 1783-IN011

Describes how to install Stratix 2500 switches.

Stratix 2500 Lightly Managed Switches User Manual, 1783-UM009

Describes how to configure and troubleshoot Stratix 2500 switches.

Stratix 6000 Ethernet Managed Switch User Manual, publication 1783-UM001

Describes how to configure and troubleshoot Stratix 6000 switches.

Stratix 5100 Wireless Access Point/Workgroup Bridge User Manual, publication 1783-UM006

Describes how to install, configure, and troubleshoot the wireless access point.

Stratix 5900 Services Router User Manual, publication 1783-UM005

Describes how to install, configure, and troubleshoot the router.

Stratix 5950 Security Appliance User Manual, publication 1783-UM010

Describes how to install, configure, and troubleshoot the security appliance.

Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1

Provides general guidelines for installing a Rockwell Automation industrial system.

Product Certifications website, http://www.rockwellautomation.com/global/certification/ overview.page

Provides declarations of conformity, certificates, and other certification details.

You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.

2

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

Page 3

Stratix Ethernet Device Specifications

Stratix 2000 Ethernet Unmanaged Switches - Series B Cat. No.

Total Ports

RJ45 Ports(1)

SFP Ports(1)

1783-US5T/B

5

5 FE, 1783-US5TG/B

5

5 GE, 1783-US4T1F/B

5

4 FE

1 FE multimode preinstalled fiber SFP module

1783-US4T1H/B

5

4 FE

1 FE singlemode preinstalled fiber SFP module

1783-US8T/B

8

8 FE, 1783-US6T2F/B

8

6 FE

2 FE multimode preinstalled fiber SFP modules

1783-US6T2H/B

8

6 FE

2 FE singlemode preinstalled fiber SFP modules

1783-US7T1F/B

8

7 FE

1 FE multimode preinstalled fiber SFP module

1783-US7T1H/B

8

7 FE

1 FE singlemode preinstalled fiber SFP module

1783-US6T2TG2F/B

10

6 FE + 2 GE

2 FE multimode preinstalled fiber SFP modules

1783-US6T2TG2H/B

10

6 FE + 2 GE

2 FE singlemode preinstalled fiber SFP modules

1783-US8TG2GX/B

10

8 GE

2 GE slots(2)

1783-US16T/B

16

16 FE, 1783-US16T2S/B

18

16 FE

2 FE slots(2)

(1) FE = Fast Ethernet; GE = Gigabit Ethernet. (2) SFP modules must be ordered separately.

Table 1 - Technical Specifications - Stratix 2000 Switches, Series B Attribute

1783-US5T/B

1783-US5TG/B

1783-US4T1F/B, 1783-US4T1H/B

1783-US8T/B

1783-US6T2F/B, 1783-US6T2H/B, 1783-US7T1F/B, 1783-US7T1H/B

1783-US6T2TG2F/B, 1783-US6T2TG2H/B

1783-US8TG2GX/B

1783-US16T/B

1783-US16T2S/B

Inrush current, max

1.85 A

0.33 A

1.69 A

1.31 A

0.41 A

1.83 A

0.55 A

0.47 A

1.63 A

Power input

24V (12…48V DC, 18...30V AC, 50/60 Hz), SELV

Power consumption, max

3.4 W

4.5 W

3.4 W

4.6 W

4.6 W

7.5 W

10 W

8.0 W

8.0 W

Current, nom

DC 180 mA AC 360 mA

DC 250 mA AC 500 mA

DC 180 mA AC 360 mA

DC 250 mA AC 500 mA

DC 250 mA AC 500 mA

DC 450 mA AC 900 mA

DC 550 mA AC 1100 mA

DC 430 mA AC 860 mA

DC 430 mA AC 860 mA

Current, max

DC 380 mA AC 750 mA

DC 510 mA AC 1020 mA

DC 380 mA AC 750 mA

DC 510 mA AC 1100 mA

DC 510 mA AC 1100 mA

DC 850 mA AC 1700 mA

DC 1100 mA AC 2200 mA

DC 900 mA AC 1800 mA

DC 900 mA AC 1800 mA

Wire size, ground connection

2.5 mm2 (14 AWG) copper wire suitable for 86 °C (187 °F) above surrounding ambient temperature outside the enclosure, with a suitable ring terminal

Wire size, DC power connection

4…0.25 mm2 (12…24 AWG) twisted-pair copper wire suitable for 86 °C (187 °F) above surrounding ambient temperature outside the enclosure

Screw torque, ground terminal, max

0.91 N•m (8.05 in•lb)

Screw torque, power terminals

0.50…0.56 N•m (4.5…5.0 in•lb)

Enclosure type rating

None (open-style)

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

3

Page 4

Stratix Ethernet Device Specifications

Table 1 - Technical Specifications - Stratix 2000 Switches, Series B (continued) Attribute

1783-US5T/B

1783-US5TG/B

1783-US4T1F/B, 1783-US4T1H/B

1783-US8T/B

1783-US6T2F/B, 1783-US6T2H/B, 1783-US7T1F/B, 1783-US7T1H/B

1783-US6T2TG2F/B, 1783-US6T2TG2H/B

1783-US8TG2GX/B

1783-US16T/B

North American temp code

T4

T4A

T5

T4

T4

T4

T4

T5

ATEX temp code

T4

T4

T4

T4

T4

T4

T4

T4

IECEx temp code

T4

T4

T4

T4

T4

T4

T4

T4

MAC addresses, max supported

2K

8K

2K

2k

2K

8K

8K

8K

Preinstalled

Ordered separately: 1783-SFP100FX 1783-SFP100LX 1783-SFP100EXC 1783-SFP100ZXC 1783-SFP1GSX 1783-SFP1GLX 1783-SFP1GEXE 1783-SFP1GZX

SFP modules(1)

No SFP slots

No SFP slots

Preinstalled

No SFP slots

Preinstalled

No SFP slots

1783-US16T2S/B

Ordered separately: 1783-SFP100FX 1783-SFP100LX 1783-SFP100EXC 1783-SFP100ZXC

(1) For specifications of preinstalled SFP modules, see Table 2. For specifications of SFP modules ordered separately, see Table 54.

Table 2 - Preinstalled SFP Module Specifications - Stratix 2000 Switches Attribute

Multimode (100Base-FX)

Singlemode (100Base-LX)

Central wavelength (nm)

1310

1310

Transmission distance (km)

2

20

Applicable distance (km)

0…2

0…20

Luminous power, min (db)

-19

-10

Luminous power, max (db)

-10

-5

Receiving sensitivity (dBm)

-31

-34

Overload luminous power

-3

-3

Table 3 - Environmental Specifications - Stratix 2000 Switches, Series B Attribute

1783-US5T/B, 1783-US8T/B

1783-US5TG/B, 1783-US4T1F/B, 1783-US4T1H/B, 1783-US6T2F/B, 1783-US6T2H/B, 1783-US7T1F/B, 1783-US7T1H/B, 1783-US6T2TG2F/B, 1783-US6T2TG2H/B, 1783-US8TG2GX/B, 1783-US16T/B, 1783-US16T2S/B

Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock)

-10 °C < Ta < +60 °C (14 °F < Ta < +140 °F)

-40 °C < Ta < +75 °C (-40 °F < Ta < +167 °F)

Temperature, ambient, max

60 °C (140 °F)

75 °C (167 °F)

Temperature, surrounding air, max

60 °C (140 °F)

75 °C (167 °F)

Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold) IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat) IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)

-40…+85 °C (-40…+185 °F)

Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)

5…95% noncondensing

Vibration IEC 60068-2-6 (Test Fc, Operating)

2 g @ 10…500 Hz

Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock)

15 g

Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock)

30 g

4

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

Page 5

Stratix Ethernet Device Specifications

Table 3 - Environmental Specifications - Stratix 2000 Switches, Series B (continued) 1783-US5TG/B, 1783-US4T1F/B, 1783-US4T1H/B, 1783-US6T2F/B, 1783-US6T2H/B, 1783-US7T1F/B, 1783-US7T1H/B, 1783-US6T2TG2F/B, 1783-US6T2TG2H/B, 1783-US8TG2GX/B, 1783-US16T/B, 1783-US16T2S/B

Attribute

1783-US5T/B, 1783-US8T/B

Emissions CISPR11 (IEC 61000-6-4)

IEC 61000-6-4

ESD immunity IEC 61000-4-2

6 kV contact discharges 8 kV air discharges

Radiated RF immunity IEC 61000-4-3

10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 20V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz

EFT/B immunity IEC 61000-4-4

±4 kV at 5 kHz on power ports ±2 kV at 5 kHz on communication ports

Surge transient immunity IEC 61000-4-5

±2 kV line-line (DM) and ±4 kV line-earth (CM) on power ports ±2 kV line-earth (CM) on communication ports

Conducted RF immunity IEC 61000-4-6

10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz

Environmental rating

IP30

Table 4 - Certifications - Stratix 2000 Switches, Series B Certifications (when product is marked)(1)

1783-US5T/B, 1783-US5TG/B1783-US4T1F/B, 1783-US4T1H/B, 1783-US8T/B, 1783-US6T2F/B, 1783-US6T2H/B, 1783-US7T1F/B, 1783-US7T1H/B, 1783-US6T2TG2F/B, 1783-US6T2TG2H/B, 1783-US8TG2GX/B, 1783-US16T/B, 1783-US16T2S/B c-UL-us

UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810.

CE

European Union 2014/30/EU EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2011/65/EU RoHS, compliant with: EN 50581; Technical documentation

RCM

Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions

Ex

European Union 2014/34/EU ATEX Directive, compliant with: • EN 60079-0; General Requirements • EN 60079-15; Potentially Explosive Atmospheres, Protection "n" • II 3 G Ex nA IIC T4 Gc • DEMKO 16 ATEX 1816X

IECEx

IECEx System, compliant with: • IEC 60079-0; General Requirements • IEC 60079-15; Potentially Explosive Atmospheres, Protection "n" • II 3 G Ex nA IIC T4 Gc • IECEx UL 16.0169X

KC

Korean Certification of Broadcasting and Communications Equipment, compliant with: • Framework Act on Telecommunications and Radio Waves Act

EAC

Russian Customs Union TR CU 020/2011 EMC Technical Regulation

(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

5

Page 6

Stratix Ethernet Device Specifications

Dimensions - Stratix 2000 Switches, Series B 1783-US5T/B, 1783-US5TG/B, 1783-US4T1F/B, 1783-US4T1H/B 76.8 mm (3.02 in.) 29.6 mm (1.17 in.)

R

29.6 mm (1.17 in.)

68 mm 2.68 in.)

2000

33.5 mm (1.31 in.)

5

25.0 mm (0.98 in.)

6 mm (0.24 in.)

4

48.3 mm (1.9 in.) 35 mm (1.38 in.)

3

2

114.5 mm (4.51 in.)

20.0 mm (0.79 in.)

43.25 mm (1.70 in.)

1

OFF SW2

SW1 ON

32664-M

6

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

Page 7

Stratix Ethernet Device Specifications

1783-US8T/B, 1783-US6T2F/B, 1783-US6T2H/B, 1783-US7T1F/B, 1783-US7T1H/B 76.8 mm (3.02 in.) 45.6 mm (1.80 in.)

R

1

2000

33.5 mm (1.32 in.)

6

8

4

6

3

45.6 mm (1.8 in.)

68 mm (2.68 in.)

4

6 mm (0.24 in.)

48.3 mm (1.9 in.) 35 mm (1.38 in.)

114.5mm (4.50 in.)

35 mm (1.38 in.)

20 mm (0.79 in.)

43 mm (1.7 in.)

2

OFF SW2

SW1 ON

32663-M

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

7

Page 8

Stratix Ethernet Device Specifications

1783-US6T2TG2F/B, 1783-US6T2TG2H/B, 1783-US8TG2GX/B 114.8 mm (4.52 in.) 53.6 mm (2.11 in.)

106 mm (4.17 in.)

R

7

2000 8

52.0 mm (2.05 in.)

6 mm (0.24 in.) 5

6

3

4

G1

G2

1

2

134 mm (5.28 in.)

48.3 mm 35 mm (1.90 in.) (1.38 in.)

53.5 mm (2.11 in.)

OFF SW2

SW1 ON

32662-M

8

20.0 mm (0.79 in.)

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

Page 9

Stratix Ethernet Device Specifications

1783-US16T/B, 1783-US16T2S/B 114.8 mm (4.52 in.) 106 mm (4.17 in.)

79.6 mm (3.13 in.)

79.6 mm (3.13 in.)

2000 9

10 17

18

7

8 15

15

5

6 13

14

3

1

4 11

42.5 mm (1.67 in.)

134 mm (5.27 in.)

48.3 mm 35 mm (1.90 in.) (1.38 in.)

12

70 mm (2.76 in.)

6 mm (0.24 in.)

20 mm (0.79 in.)

53.5 mm (2.11 in.)

2

OFF SW2

SW1 ON

32661-M

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

9