Spec sheet · Allen-Bradley
Stratix Ethernet Device Specifications
Spec sheet72 pagesPDF 3.0 MB
Technical data for Allen-Bradley Stratix Ethernet switches, routers and appliances, including the Stratix 2000 unmanaged switches such as the 1783-US8T.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
Technical data covering the whole Stratix Ethernet line: Stratix 2000 unmanaged switches (series A and B, including the 8-port 1783-US8T), Stratix 2500 lightly managed switches, Stratix 5400, 5410, 5700, ArmorStratix 5700, 6000, 8000 and 8300 managed switches, the Stratix 5100 wireless access point, 5900 services router, 5950 security appliance, embedded switch taps and the configurable NAT router. For each it gives catalog numbers, port counts, power, environmental and certification specifications and dimensions, plus SFP modules, memory cards and Ethernet cables.
Its parts
- Stratix 2000 Ethernet Unmanaged Switches, Series B
- Stratix 2000 Ethernet Unmanaged Switches, Series A
- Stratix 2500 Ethernet Lightly Managed Switches
- Stratix 5400 Ethernet Managed Switches
- Stratix 5410 Ethernet Managed Switches
- Stratix 5700 Ethernet Managed Switches
- ArmorStratix 5700 Ethernet Managed Switches
- Stratix 6000 Ethernet Managed Switches
- Stratix 8000 and Stratix 8300 Ethernet Managed Switches
- Stratix 5100 Wireless Access Point/Workgroup Bridge
- Stratix 5900 Services Router
- Stratix 5950 Security Appliance
- Embedded Switch Technology
- Configurable NAT Router
- Accessories
From the sheet
Key facts from this sheet
Each line names its page in the PDF.
Rockwell Automation technical data (publication 1783-TD001T-EN-P, July 2018) with specifications for the Stratix 2000, 2500, 5400, 5410, 5700, ArmorStratix 5700, 6000, 8000 and 8300 switches, the Stratix 5100, 5900 and 5950, Embedded Switch Technology and the Configurable NAT Router. It lists the 8-port 1783-US8T/A and 1783-US8T/B but never prints the catalog number 1783-US08T. For the Stratix 2000 unmanaged switches it gives ports, power, wiring, environment, dimensions and series A to B replacements, plus SFP modules and Ethernet cables.
- Product family
- Stratix 2000 unmanaged Ethernet switches (1783-US), in series A and series B p. 1, 2, 10
- 1783-US8T ports
- 1783-US8T/A and 1783-US8T/B: 8 ports, all Fast Ethernet RJ45 p. 3, 10
- Series replacement
- 1783-US8T/A is replaced by 1783-US8T/B, same catalog number and configuration p. 10
- Power, series B
- 24V (12…48V DC or 18...30V AC, 50/60 Hz), SELV p. 3
- Power, series A
- 24V (18...60V DC or 18...30V AC 50/60 Hz), Class 2/SELV p. 11
- Operating temperature
- Series B: -10 °C to +60 °C for 1783-US5T/B and 1783-US8T/B; -40 °C to +75 °C for the other series B switches p. 4
- Wiring, series B
- DC power: 4…0.25 mm2 (12…24 AWG) twisted-pair copper; ground: 2.5 mm2 (14 AWG) copper with a ring terminal p. 3
- Terminal torque, series B
- Ground terminal 0.91 N•m (8.05 in•lb) max; power terminals 0.50…0.56 N•m (4.5…5.0 in•lb) p. 3
- Environment, series B
- 5…95% humidity noncondensing; vibration 2 g @ 10…500 Hz; shock 15 g operating, 30 g nonoperating; nonoperating -40…+85 °C p. 4
- Enclosure, series B
- Open-style (no enclosure type rating); environmental rating IP30 p. 3, 5
- Isolation, series A
- 30V continuous basic insulation, power to network channels; type tested at 500V AC for 60 s p. 11
- Fast Ethernet SFP modules
- 1783-SFP100FX (100BASE-FX multimode fiber) and 1783-SFP100LX (100BASE-LX singlemode fiber), both dual LC p. 69
- Ethernet patchcord
- 1585J-M8TBJM-2: male RJ45 to male RJ45, unshielded twisted pair, 8-conductor (4-pair), 2 m (6.56 ft) p. 71
- Related manuals
- Stratix 2000 installation: 1783-IN003; user manual for DIP switches and status indicators: 1783-UM011 p. 2
What this sheet walks you through
- Comparing port counts of Stratix 2000 series B switches p. 3
- Power, wiring, environmental and certification data for series B switches p. 3, 4, 5
- Mounting dimensions of series B switches p. 6, 7, 8, 9
- Finding the series B replacement for a series A switch p. 10
- Specifications of series A switches p. 11, 12, 13
- Mounting dimensions of series A switches p. 14, 15, 16
- Choosing SFP modules and checking which switches accept them p. 69, 70
- Ordering Ethernet patchcords, cable spools and field-attachable connectors p. 71
Good to know
- With SFP modules installed, the combined temperature rating is limited to the narrowest range of the switch and modules. p. 69
- SFP modules ordered separately for Stratix 2000 switches are not the same as the preinstalled ones. p. 70
- Gigabit Ethernet SFP modules work only in Gigabit Ethernet SFP slots. p. 70
- Series A switches have no isolation between individual network channels. p. 11
- Back-to-back links with 1783-SFP1GEXE modules need a 5-dB inline optical attenuator at each end. p. 69
Questions this sheet answers
What replaced the 1783-US8T/A switch?
The 1783-US8T/B series B switch, with the same catalog number and configuration. p. 10
How many ports does the 1783-US8T have?
Both 1783-US8T/A and 1783-US8T/B have 8 Fast Ethernet RJ45 ports. p. 3, 10
What power does a Stratix 2000 series B switch need?
24V nominal, from 12…48V DC or 18...30V AC at 50/60 Hz, SELV. p. 3
What is the operating temperature of the 1783-US8T/B?
-10 °C to +60 °C (14 °F to 140 °F). p. 4
Where are the Stratix 2000 DIP switches and status lights explained?
In the Stratix 2000 Ethernet Unmanaged Switches User Manual, publication 1783-UM011. p. 2
Contents
Chapters and sections
Each line opens the PDF at its page.
- Stratix Ethernet Device Specifications Technical Data1
- Summary of Changes2
- Additional Resources2
- Stratix 2000 Ethernet Unmanaged Switches - Series B3
- Stratix 2000 Ethernet Unmanaged Switches - Series A10
- Stratix 2500 Ethernet Lightly Managed Switches17
- Stratix 5400 Ethernet Managed Switches21
- Stratix 5410 Ethernet Managed Switches25
- Stratix 5700 Ethernet Managed Switches31
- ArmorStratix 5700 Ethernet Managed Switches41
- Stratix 6000 Ethernet Managed Switches46
- Stratix 8000 and Stratix 8300 Ethernet Managed Switches49
- Stratix 5100 Wireless Access Point/Workgroup Bridge56
- Stratix 5900 Services Router58
- Stratix 5950 Security Appliance60
- Embedded Switch Technology63
- Configurable NAT Router66
- Accessories69
- Back Cover72
The whole text · 8 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file


