Page 46
Stratix Ethernet Device Specifications
Stratix 6000 Ethernet Managed Switches Table 27 - Technical Specifications - Stratix 6000 Switches Attribute
1783-EMS08T
1783-EMS04T
Description
Stratix 6000 managed switch • 8 ports • 1 fiber SFP slot
Stratix 6000 managed switch 4 ports
Power input
250 mA @ 24V DC (12…48V DC) CL 2/SELV
100 mA @ 24V DC (12…48V DC) CL 2/SELV
Power dissipation, max
5.8 W
2.6 W
Thermal dissipation, max
24.6 BTU/hr @ 60 °C (140 °F)
Network ports
8 RJ45 10/100 full/half duplex ports, optional SFP transceiver port
Protocols
TCP/IP, EtherNet/IP, Telnet, Http, DHCP, BOOTP, FTP, IGMP, SMTP
Indicators
16 port indicators 3 status indicators
EtherNet/IP features
MAC ID management, bandwidth alarming, port control, link status, scaled bandwidth information, and connections active
Switch features
VLAN, IGMP snooping, IGMP query V1 and V2, DHCP server, BOOTP server, QoS, port mirroring
IGMP snooping, IGMP query V1 and V2, DHCP server, BOOTP server, QoS, port mirroring
Options
1 GB fiber-optic transceiver, Inrush current, max
2.2 A
Isolation voltage
50V (continuous), basic insulation type, power to ground and power to network channels No isolation between individual network channels Routine tested at 707V AC for 1 s
Wire size, Ethernet connection(1)
RJ45 connector according to IEC 60603-7, 2- or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702
Wire size, DC power connection
0.33…3.3 mm2 (22…12 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater, 1.2 mm (3/64 in.) insulation max
Wire size, ground connection
3.3 mm2 (12 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater
Screw torque, power and ground terminals
1.36 N•m (12 in•lb)
Wiring category(2)
2 - on DC power ports 2 - on communication ports
Enclosure type rating
None (open-style)
North American temp code
T4
ATEX temp code
T4
SFP modules(3)
1783-SFP1GSX 1783-SFP1GLX
4 RJ45 10/100 full/half duplex ports
8 port indicators 2 status indicators
(1) See page 71 for recommended products. (2) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. (3) SFP modules are supported only on switches with combo ports or SFP slots. For SFP specifications, see page 69.
46
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 47
Stratix Ethernet Device Specifications
Table 28 - Environmental Specifications - Stratix 6000 Switches Attribute
1783-EMS04T, 1783-EMS08T
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
0 °C < Ta < +60 °C (+32 °F < Ta < +140 °F)
Temperature, ambient, max
60 °C (140 °F)
Temperature, surrounding air, max
60 °C (140 °F)
Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
-40…+85 °C (-40…+185 °F)
Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
5…95% noncondensing
Vibration IEC 60068-2-6 (Test Fc, Operating)
2 g @ 10…500 Hz
Operating shock IEC 60068-2-27 (Test Ea, Unpackaged Shock)
15 g
Nonoperating shock IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30 g
Emissions IEC 61000-6-4
IEC 61000-6-4
ESD immunity IEC 61000-4-2
6 kV contact discharges 8 kV air discharges
Radiated RF immunity IEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 1V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
EFT/B immunity IEC 61000-4-4
±2 kV at 5 kHz on power ports ±1 kV at 5 kHz on communication ports
Surge transient immunity IEC 61000-4-5
±1 kV line-line (DM) and ±2 kV line-earth (CM) on AC power ports ±2 kV line-earth (CM) on communication ports
Conducted RF immunity IEC 61000-4-6
10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Magnetic field immunity IEC 61000-4-8
30 A/m long duration and 300 A/m short duration at 50 Hz and 60 Hz
Voltage variation IEC 61000-4-29
10 ms interruption on DC supply ports
Environmental rating
IP20
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
47
Page 48
Stratix Ethernet Device Specifications
Table 29 - Certifications - Stratix 6000 Switches Certifications (when product is marked)(1)
1783-EMS08T, 1783-EMS04T c-UL-us
UL Listed Information Technology Equipment, certified for US and Canada. See UL File E151729.
c-ETL-us
ETL Listed Industrial Control Equipment, certified for US and Canada.
c-ETL-us
ETL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada
CE
European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2011/65/EU RoHS, compliant with: EN 50581; Technical documentation
RCM
Australian Radiocommunications Act, compliant with: EN 61000-6-4; Industrial Emissions
Ex
EN 60079-0; General Requirements EN 60079-11; Explosive Atmospheres, Protection "i" EN 60079-15; Potentially Explosive Atmospheres, Protection "n" II 3 Ex ic nA IIC T4 Gc
KC
Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3
EtherNet/IP
ODVA conformance tested to EtherNet/IP specifications
(1) See the Product Certification link at www.ab.com for Declarations of Conformity, Certificates, and other certification details.
Dimensions - Stratix 6000 Switches Mount the switches, as shown, in the vertical position only. We do not recommend horizontal mounting due to thermal considerations. Follow these guidelines: • Provide 50 mm (2 in.) of space on all sides for adequate heat dissipation. • Leave 100 mm (4 in.) for installation and removal if using the fiber-optic port on the bottom of the 1783-EMS08T switch. 52.07 mm (2.05 in.)
118 mm (4.64 in.)
107 mm (4.21 in.)
1 2
12 cm (0.47 in.) 12 mm (0.47 in.)
48
27.7 mm (1.09 in.)
SFP Module Installed
88.9 mm (3.50 in.)
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 49
Stratix Ethernet Device Specifications
Stratix 8000 and Stratix 8300 Ethernet Managed Switches Table 30 - Technical Specifications - Stratix 8000 and Stratix 8300 Switches Attribute
1783-MS06T
1783-MS10T
1783-RMS06T
1783-RMS10T
Description
Stratix 8000 managed switch, Layer 2, 6 ports
Stratix 8000 managed switch, Layer 2, 10 ports
Stratix 8300 managed switch, Layer 3, 6 ports
Stratix 8300 managed switch, Layer 3, 10 ports
Inrush current, max
2.0 A
Power input, max
2 A max @ 18…60V DC, CL 2/SELV
Alarm relay, max
1 A max @ 30V DC, CL 2/SELV
Power consumption, max (Expansion module power not included)
15.1 W
15.7 W
15.1 W
15.7 W
Power dissipation
15.1 W
15.7 W
15.1 W
15.7 W
Isolation voltage
75V (continuous), basic insulation type, power to ground, power to network channels, and power to alarm No isolation between individual Ethernet ports No isolation between console port and system Type tested at 1000V AC for 60 s
RJ45 connector according to IEC 60603-7, 2- or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to Wire size, Ethernet connection(1) ISO/IEC 24702 Wire size, DC power and alarm connections
0.5…0.8 mm2 (20…18 AWG) solid or stranded copper wire rated at 90 °C (194 °F) or greater, 1.2 mm (3/64 in.) insulation max
Wire size, ground connection
3.3…5.3 mm2 (12…10 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater
Screw torque, power and alarm terminals
0.23 N•m (2.0 in•lb)
Wiring category(2)
2 - on alarm ports 2 - on power ports 2 - on Ethernet ports
Enclosure type rating
None (open-style)
Pilot duty rating
Not rated
North American temp code
T4
IEC temp code
T4
SFP modules(3)
1783-SFP100FX 1783-SFP100LX 1783-SFP100EXC 1783-SFP100ZXC 1783-SFP100T(4) 1783-SFP1GSX 1783-SFP1GLX 1783-SFP1GEXE 1783-SFP1GZX 1783-SFP1GTE
1783-SFP100FX 1783-SFP100LX 1783-SFP100EXC 1783-SFP100ZXC 1783-SFP1GSX 1783-SFP1GLX 1783-SFP1GEXE 1783-SFP1GZX 1783-SFP1GTE
Memory card
1783-MCF
1783-RMCF
(1) (2) (3) (4)
See page 71 for recommended products. Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. SFP modules are supported only on switches with combo ports or SFP slots. For SFP specifications, see page 69. The 1783-SFP100T module requires Stratix 8000 firmware revision 12.001or later.
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
49
Page 50
Stratix Ethernet Device Specifications
Table 31 - Environmental Specifications - Stratix 8000 and Stratix 8300 Switches Attribute
1783-MS06T, 1783-MS10T, 1783-RMS06T, 1783-RMS10T
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
-40…+60 °C (-40…+140 °F)
Temperature, surrounding air, max
60 °C (140 °F)
Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
-40…+85 °C (-40…+185 °F)
Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
5…95% noncondensing
Vibration IEC 60068-2-6 (Test Fc, Operating)
2 g @ 10…500 Hz
Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
20 g
Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30 g
Emissions CISPR11 (IEC 61000-6-4)
Class A
ESD immunity IEC 61000-4-2
8 kV contact discharges 15 kV air discharges
Radiated RF immunity IEC 61000-4-3
20V/m with 1 kHz sine-wave 80% AM from 80…1000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 1000…2700 MHz
EFT/B immunity IEC 61000-4-4
±4 kV at 2.5 kHz and ±2 kV at 5 kHz on power ports ±4 kV at 2.5 kHz and ±2 kV at 5 kHz on alarm ports ±4 kV at 2.5 kHz and ±2 kV at 5 kHz on Ethernet ports
Surge transient immunity IEC 61000-4-5
±1 kV line-line (DM) and ±2 kV line-earth (CM) on power ports ±1 kV line-line (DM) and ±2 kV line-earth (CM) on alarm ports ±2 kV line-earth (CM) on Ethernet ports
Conducted RF immunity IEC 61000-4-6
10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Magnetic field immunity IEC 61000-4-8
30 A/m long duration and 300 A/m short duration at 50 Hz and 60 Hz
Oscillatory surge withstand IEEE C37.90.1
2.5 kV
Voltage variation IEC 61000-4-29
10 ms interruption on DC supply ports
Environmental rating
IP20
50
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 51
Stratix Ethernet Device Specifications
Table 32 - Certifications - Stratix 8000 and Stratix 8300 Switches Certifications (when product is marked)(1) 1783-MS06T, 1783-MS10T, 1783-RMS06T, 1783-RMS10T c-UL-us
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810.
CE
European Union 2004/108/EC EMC Directive, compliant with: • EN 61326-1; Meas./Control/Lab., Industrial Requirements • EN 61000-6-2; Industrial Immunity • EN 61000-6-4; Industrial Emissions • EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2011/65/EU RoHS, compliant with: • EN 50581; Technical Documentation
C-Tick
Australian Radiocommunications Act, compliant with: • AS/NZS CISPR 11; Industrial Emissions
Ex
European Union 94/9/EC ATEX Directive, compliant with: • EN 60079-15; Potentially Explosive Atmospheres, Protection "n" • EN 60079-0; General Requirements • II 3 G Ex nA nC IIC T4 Gc X
KC
Korean Certification of Broadcasting and Communications Equipment, compliant with: • Framework Act on Telecommunications and Radio Waves Act
EtherNet/IP
ODVA conformance tested to EtherNet/IP specifications
(1) See the Product Certification link at http://www.ab.com for declarations of conformity, certificates, and other certification details.
Optional Expansion Modules - Stratix 8000 and Stratix 8300 Switches Cat. No.
Description
1783-MX08T
Expansion module with 8 10/100 Base-T copper Ethernet ports
1783-MX08F
Expansion module with 8 100 Base-F fiber-optic Ethernet ports
1783-MX04S
Expansion module with 4 100 FX fiber-optic SFP slots
1783-MX08S
Expansion module with 8 100 FX fiber-optic SFP slots
1783-MX04E
Expansion module with 4 PoE ports
1783-MX04T04E
Ethernet expansion module with 4 10/100 Base-T copper Ethernet ports and 4 PoE ports
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
51
Page 52
Stratix Ethernet Device Specifications
Table 33 - Technical Specifications - Stratix 8000 and Stratix 8300 Expansion Modules Attribute
1783-MX08T
1783-MX08F
1783-MX04S
1783-MX08S
Description
Expansion module 8 ports, copper
Expansion module 8 ports, fiber
Expansion module 4 SFP ports, fiber
Expansion module 8 SFP ports, fiber
Backplane power
3.3V DC, 1.7 A max
3.3V DC, 3.6 A max
3.3V DC, 2.5 A max
3.3V DC, 4.0 A max
Power consumption, max
2.8 W
10.1 W
7.6 W
12.2 W
Power dissipation
2.8 W
10.1 W
7.6 W
12.2 W, Isolation voltage
75V (continuous), basic insulation type, expansion backplane to network channels No isolation between individual Ethernet ports Type tested at 1000V AC for 60 s
Wire size, Ethernet connection(1)
RJ45 connector according to IEC 60603-7, 2- or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702, Wiring category(2)
2 - on Ethernet ports, Enclosure type rating
None (open-style)
North American temp code
T4
IEC temp code
T4
SFP modules(3)
(1) (2) (3) (4)
1783-SFP100FX 1783-SFP100LX 1783-SFP100EXC 1783-SFP100ZXC 1783-SFP100T(4), See page 71 for recommended products. Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. For SFP specifications, see page 69. The 1783-SFP100T module requires Stratix 8000 firmware revision 12.001or later.
Table 34 - Technical Specifications - Stratix 8000 and Stratix 8300 Fiber Expansion Module Attribute
1783-MX08F
Ethernet data rate
100 Mbps
Connecting mode
Full-duplex
Optical wavelength
1310 nm
Optical cable length, max
Graded index multimode fiber; 2000 m
Optical link budget
8 dB with 62.5/125 μm multimode cable 4 dB with 50/125 μm multimode cable
Connector type
IEC 61754-20 LC connector
52
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 53
Stratix Ethernet Device Specifications
Table 35 - Technical Specifications - Stratix 8000 and Stratix 8300 Power over Ethernet Expansion Modules Attribute
1783-MX04E
1783-MX04T04E
Description
Expansion module 4 ports, Power over Ethernet
Expansion module • 4 ports, copper • 4 ports, Power over Ethernet
Backplane power
3.3V DC, 0.94 A max
3.34V DC, 1.08 A max
Power over Ethernet input power
48V DC for PoE 54V DC for PoE+ for a combination of PoE and PoE+ 2.5 A max
48V DC for PoE 54V DC for PoE+ for a combination of PoE and PoE+ 2.4 A max
Power consumption(1)
3 W @ 24V DC @ 40˚C (104˚F), 7.3 W max PoE power at 44V: 62 W max
3.5 W @ 24V DC @ 40˚C (104˚F), 7.9 W max PoE power at 44V: 62 W max
Power dissipation
7.3 W
7.9 W
Isolation voltage
60V (continuous), basic insulation type, expansion backplane to network ports, expansion backplane to power ports, and power ports to network ports No isolation between individual network ports Type tested at 1570V DC for 60 s
Wire size, Ethernet connection(2)
RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702
Wiring category(3)
2 - on Ethernet ports 2 - on power ports
Enclosure type rating
None (open-style)
North American temp code
T4
IEC temp code
T4
SFP modules, (1) For PoE configurations, the power consumption values listed represent the highest values that can be configured using all ports. A general guideline is 0.5 W per 30 W PoE+ port used. (2) See page 71 for recommended products. (3) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Table 36 - Environmental Specifications - Stratix 8000 and Stratix 8300 Expansion Modules Attribute
1783-MX08T
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
-40…+60 °C (-40…+140 °F)
Temperature, surrounding air, max
60 °C (140 °F)
1783-MX08F
1783-MX04S, 1783-MX08S
1783-MX04E, 1783-MX04T04E
Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry -40…+85 °C (-40…+185 °F) Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
5…95% noncondensing
Vibration IEC 60068-2-6 (Test Fc, Operating)
2 g @ 10…500 Hz
Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
20 g
Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30 g
15 g
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
53
Page 54
Stratix Ethernet Device Specifications
Table 36 - Environmental Specifications - Stratix 8000 and Stratix 8300 Expansion Modules (continued) 1783-MX08F
1783-MX04S, 1783-MX08S
Attribute
1783-MX08T
1783-MX04E, 1783-MX04T04E
Emissions CISPR11 (IEC 61000-6-4)
Group 1, Class A
ESD immunity IEC 61000-4-2
8 kV contact discharges 15 kV air discharges
6 kV contact discharges 8 kV air discharges
Radiated RF immunity IEC 61000-4-3
20V/m with 1 kHz sine-wave 80% AM from 80…1000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 1000…2700 MHz
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
EFT/B immunity IEC 61000-4-4
±4 kV at 2.5 kHz and ±2 kV at 5 kHz on Ethernet ports
Surge transient immunity IEC 61000-4-5, ±2 kV at 5 kHz on power ports and ±2 kV at 5 kHz on Ethernet ports
±2 kV line-earth (CM) on Ethernet ports, ±1 kV line-line(DM) and ±2 kV line-earth(CM) on power ports ±2 kV line-earth(CM) on communication ports
Conducted RF immunity IEC 61000-4-6
10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Magnetic field immunity IEC 61000-4-8
30 A/m long duration and 300 A/m short duration at 50 Hz and 60 Hz
30 A/m long duration and 300 A/m short duration at 50 Hz
Magnetic pulse immunity IEC 61000-4-9, 300 A/m pulse
Oscillatory surge withstand IEEE C37.90.1
2.5 kV
Damped oscillatory wave immunity IEC 61000-4-18, - ±1 kV line-line(DM) and ±2.5 kV line-earth(CM) on power ports
Table 37 - Certifications - Stratix 8000 and Stratix 8300 Expansion Modules Certifications (when product is marked)(1)
1783-MX08T, 1783-MX08F, 1783-MX04S, 1783-MX08S, 1783-MX04E, 1783-MX04T04E c-UL-us
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. UL Listed for Class I, Zone 2 Hazardous Locations, certified for U.S. and Canada. See UL File E194810. AEx/Ex nA IIC T4 Gc X
CE
European Union 2004/108/EC EMC Directive, compliant with: • EN 61326-1; Meas./Control/Lab., Industrial Requirements • EN 61000-6-2; Industrial Immunity • EN 61000-6-4; Industrial Emissions • EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2011/65/EU RoHS, compliant with: • EN 50581; Technical Documentation
C-Tick
Australian Radiocommunications Act, compliant with: • AS/NZS CISPR 11; Industrial Emissions
Ex
European Union 94/9/EC ATEX Directive, compliant with: • EN 60079-15; Potentially Explosive Atmospheres, Protection "n" • EN 60079-0; General Requirements • II 3 G Ex nA IIC T4 Gc X
KC
Korean Certification of Broadcasting and Communications Equipment, compliant with: • Framework Act on Telecommunications and Radio Waves Act
EtherNet/IP
ODVA conformance tested to EtherNet/IP specifications
(1) See the Product Certification link at http://www.ab.com for declarations of conformity, certificates, and other certification details.
54