Table 23 - Certifications - Stratix 5700 Switches Certifications (when product is marked)(1)
Stratix 5700 Switches c-UL-us
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. UL Listed for Class I, Zone 2 Hazardous Locations, certified for U.S. and Canada. See UL File E194810. AEx/Ex nA nC IIC T4 Gc X
CE
European Union 2004/108/EC EMC Directive, compliant with: • EN 61326-1; Meas./Control/Lab., Industrial Requirements • EN 61000-6-2; Industrial Immunity • EN 61000-6-4; Industrial Emissions • EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2011/65/EU RoHS, compliant with: • EN 50581; Technical Documentation
C-Tick
Australian Radiocommunications Act, compliant with: • AS/NZS CISPR 11; Industrial Emissions
Ex
European Union 94/9/EC ATEX Directive, compliant with: • EN 60079-15; Potentially Explosive Atmospheres, Protection "n" • EN 60079-0; General Requirements • II 3 G Ex nA nC IIC T4 Gc X
KC
Korean Registration of Broadcasting and Communications Equipment, compliant with: • Article 58-2 of Radio Waves Act, Clause 3
EtherNet/IP
ODVA conformance tested to EtherNet/IP specifications
(1) See the Product Certification link at http://www.ab.com for declarations of conformity, certificates, and other certification details.
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
37
Page 38
Stratix Ethernet Device Specifications
Dimensions - Stratix 5700 Switches To prevent the switch from overheating, observe the following minimum clearances: • Top and bottom: 50.8 mm (2.0 in.) • Sides: 50.8 mm (2.0 in.) • Front: 50.8 mm (2.0 in.) These diagrams are representative of the Stratix 5700 switches. Actual faceplates vary depending on the catalog number. 6-port Switches 1783-BMS06SL, 1783-BMS06SA, 1783-BMS06TL, 1783-BMS06TA, 1783-BMS06SGL, 1783-BMS06SGA, 1783-BMS06TGL, 1783-BMS06TGA
6 SFP-port Switches 1783-BMS4S2SGL, 1783-BMS4S2SGA
7.48 cm (2.94 in.)
8.00 cm (3.15 in.)
R
R
Express Setup
Console
Pwr A
DC+
DCPwr B
DC+
Alarm IN1 IN2 OUT
12.95 cm (5.1 in.)
12.95 cm (5.1 in.)
Com IN2 Ref IN1
12.19 cm (4.8 in.) 11.45 cm (4.51 in.)
38
0.75 cm (0.29 in.)
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
11.67 cm (4.59 in.) 10.92 cm (4.3 in.)
0.75 cm (0.29 in.)
Page 39
Stratix Ethernet Device Specifications
10-port Switch 1783-BMS10CGP, 1783-BMS10CGN
10-port Switches 1783-BMS10CL, 1783-BMS10CA, 1783-BMS10CGL, 1783-BMS10CGA
9.14 cm (3.6 in.)
9.14 cm (3.6 in.) R
R
12.95 cm (5.1 in.)
11.67 cm (4.59 in.) 10.92 cm (4.3 in.)
12.95 cm (5.1 in.)
0.75 cm (0.29 in.)
13.58 cm (5.345 in.) 12.83 cm (5.05 in.)
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
0.75 cm (0.29 in.)
39
Page 40
Stratix Ethernet Device Specifications
18-port and 20-port Switches 1783-BMS12T4E2CGNK, 1783-BMS12T4E2CGP, 1783-BMS12T4E2CGL, 1783-BMS20CL, 1783-BMS20CA, 1783-BMS20CGL, 1783-BMS20CGP, 1783-BMS20CGN, 1783-BMS20CGPK
12.70 cm (5.0 in.) R
12.95 cm (5.1 in.)
13.58 cm (5.345 in.) 12.83 cm (5.05 in.)
40
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
0.75 cm (0.29 in.)
Page 41
Stratix Ethernet Device Specifications
ArmorStratix 5700 Ethernet Managed Switches Cat. No.
Total Ports
M12 D-code Ports
M12 X-code Ports
PoE/PoE+ Ports Firmware Type
CIP Sync (IEEE 1588)
NAT
DLR
1783-ZMS8TA
8
8 FE, - Full, - - 1783-ZMS4T4E2TGP
10
4 FE
2 GE
4 FE
Full
Yes, Yes
1783-ZMS4T4E2TGN 10
4 FE
2 GE
4 FE
Full
Yes
Yes
Yes
1783-ZMS16TA
16
16 FE, - Full, - - 1783-ZMS8T8E2TGP
18
8 FE
2 GE
8 FE
Full
Yes, Yes
1783-ZMS8T8E2TGN 18
8 FE
2 GE
8 FE
Full
Yes
Yes
Yes
1783-ZMS24TA
24 FE, - Full, - - 24
Table 24 - Technical Specifications - ArmorStratix 5700 Switches 1783-ZMS16TA
1783-ZMS24TA
1783-ZMS4T4E2TGP, 1783-ZMS4T4E2TGN
1783-ZMS8T8E2TGP, 1783-ZMS8T8E2TGN
Attribute
1783-ZMS8TA
Power input
User supply (non PoE): 9.6…60V DC, 2.9 A max 1.5 A max @ 12…48V DC 1.8 A max @ 12…48V DC 2.0 A max @ 12…48V DC Alarm: 30V DC, 1 A or 48V DC, 0.5 A
Power over Ethernet (PoE) input power, - - 44…57V DC (48V DC nom) for PoE 50…57V DC (54V DC nom) for PoE+ or a combination of PoE/PoE+
Power consumption(1)
7 W @ 24V DC @ 40˚C (104˚F) 17 W max
10 W @ 24V DC @ 40˚C (104˚F) 20 W max
12 W @ 24V DC @ 40˚C (104˚F) 22 W max
11.5 W @ 24V DC @ 40˚C (104˚F) 22 W max Max PoE power @ 50V: 62 W
17 W @ 24V DC @ 40˚C (104˚F) 30 W max Max PoE power @ 50V: 120 W
Power dissipation
17 W
20 W
22 W
21 W
24 W
Isolation voltage
60V (continuous), basic insulation type, DC power ports to ground, and PoE power ports to ground No isolation between individual Ethernet ports No isolation between PoE power and Ethernet ports No isolation between console port and system Type tested at 1570V DC for 60 s
Wire size, ground connection
4.0 mm2 (12 AWG) min, stranded copper wire
Wire size, Ethernet connection(2)
IP67-rated M12 D-code or X-code connectors according to ODVA EtherNet/IP specifications and ISO/IEC 24702/61918
User supply (non PoE): 9.6…60V DC, 3.3 A max Alarm: 30V DC, 1 A or 48V DC, 0.5 A
Screw torque, ground terminal, max 1.13 N•m (10.0 in•lb) Weight, approx
3 kg (7.19 lb)
3 kg (7.28 lb)
4 kg (8.86 lb)
Wiring category(3)
3 - on console 2 - on DC power ports 2 - on Ethernet ports
Pilot duty rating, Enclosure type rating
Meets IP66, IP67, and Type 4
Industry standards
Substation KEMA (IEEE 1613, IEC 61850 - 3) IEEE 1613 Electric Power Stations Communications Networking IEC 61850-3 Electric Substations Communications Networking
3 kg (7.19 lb)
3 kg (7.28 lb)
3 - on console 2 - on DC power and alarm ports 2 -on Ethernet ports, - Alarm not rated
(1) For PoE configurations, the power consumption values listed represent the highest values that can be configured using all ports. A general guideline is 0.5 W per 30 W PoE+ port used. (2) See page 71 for recommended products. (3) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
41
Page 42
Stratix Ethernet Device Specifications
Table 25 - Environmental Specifications - ArmorStratix 5700 Switches Attribute
1783-ZMS8TA, 1783-ZMS16TA, 1783-ZMS24TA
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
-40…+60 °C (-40…+140 °F)
Temperature, ambient, max
60 °C (140 °F)
1783-ZMS4T4E2TGP, 1783-ZMS8T8E2TGP, 1783-ZMS4T4E2TGN, 1783-ZMS8T8E2TGN
Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), -40…+85 °C (-40…+185 °F) IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
5…95% noncondensing
Vibration IEC 60068-2-6 (Test Fc, Operating)
2 g @ 10…500 Hz
Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
15 g
Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30 g
Emissions CISPR11 (IEC 61000-6-4)
Class A
ESD immunity IEC 61000-4-2
8 kV contact discharges 15 kV air discharges
Radiated RF immunity IEC 61000-4-3
20V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 20V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
EFT/B immunity IEC 61000-4-4
±4 kV at 5 kHz on DC power ports ±4 kV at 5 kHz on Ethernet ports
±4 kV at 5 kHz on DC power ports ±4 kV at 5 kHz on Ethernet ports ±4 kV at 5 kHz on alarm ports
Surge transient immunity IEC 61000-4-5
±1 kV line-line (DM) and ±2 kV line-earth (CM) on DC power ports ±4 kV line-earth (CM) on Ethernet ports
±1 kV line-line (DM) and ±2 kV line-earth (CM) on DC power ports ±4 kV line-earth (CM) on Ethernet ports ±1 kV line-line (DM) and ±2 kV line-earth (CM) on alarm ports
Conducted RF immunity IEC 61000-4-6
10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Magnetic field immunity IEC 6100-4-8
300 A/m long duration and 1000 A/m short duration at 50 Hz and 60 Hz
Magnetic pulse immunity IEC 6100-4-9
300 A/m pulse
Damped oscillatory wave immunity IEC 61000-4-18
±1 kV line-line (DM) and ±2.5 kV line-earth (CM) on DC power ports ±2.5 kV line-earth (CM) on Ethernet ports
Environmental rating
IP66, IP67
42
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
±1 kV line-line (DM) and ±2.5 kV line-earth (CM) on DC power and alarm ports ±2.5 kV line-earth (CM) on Ethernet ports
Page 43
Stratix Ethernet Device Specifications
Table 26 - Certifications - ArmorStratix 5700 Switches Certifications (when product is marked)(1)
1783-ZMS8TA, 1783-ZMS16TA, 1783-ZMS24TA c-UL-us
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584.
CE
European Union 2004/108/EC EMC Directive, compliant with: • EN 61326-1; Meas./Control/Lab., Industrial Requirements • EN 61000-6-2; Industrial Immunity • EN 61000-6-4; Industrial Emissions • EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2011/65/EU RoHS, compliant with: • EN 50581; Technical Documentation
RCM
Australian Radiocommunications Act, compliant with: • EN 61000-6-4; Industrial Emissions
KC
Korean Registration of Broadcasting and Communications Equipment, compliant with: • Article 58-2 of Radio Waves Act, Clause 3
EtherNet/IP
ODVA conformance tested to EtherNet/IP specifications
1783-ZMS4T4E2TGP, 1783-ZMS8T8E2TGP, 1783-ZMS4T4E2TGN, 1783-ZMS8T8E2TGN
(1) See the Product Certification link at http://www.ab.com for declarations of conformity, certificates, and other certification details.
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
43
Page 44
Stratix Ethernet Device Specifications
Dimensions - ArmorStratix 5700 Switches To prevent the switch from overheating, observe the following minimum clearances: • Top and bottom: 50.8 mm (2.0 in.) • Sides: 50.8 mm (2.0 in.) • Front: 50.8 mm (2.0 in.) These diagrams are representative of the ArmorStratix 5700 switches. Actual faceplates vary depending on the catalog number. 16-port and 18-port Switches 1783-ZMS16TA, 1783-ZMS8T8E2TGP, 1783-ZMS8T8E2TGN
8-port and 10-port Switches 1783-ZMS8TA, 1783-ZMS4T4E2TGP, 1783-ZMS4T4E2TGN
30.09 cm (11.85in.)
23.75 cm (9.35 in.) 5.78 cm (2.2 in.)
24.38 cm (9.6 in.)
5.78 cm (2.2 in.)
24.38 cm (9.6 in.)
14.47 cm (5.6 in.)
14.47 cm (5.6 in.)
2 4
3.93 cm (1.5 in.)
3.93 cm (1.5 in.)
32493
32492
21.58 cm (8.4 in.)
27.98 cm (11.0 in.) 24-port Switch 1783-ZMS24TA 37.46 cm (14.75in.)
5.78 cm (2.2 in.)
24.38 cm (9.6 in.) 14.47 cm (5.6 in.)
3.93 cm (1.5 in.) 32494
35.38 cm (13.9 in.)
44
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 45
Stratix Ethernet Device Specifications
16-port and 24-port Switches 1783-ZMS16TA, 1783-ZMS24TA, 1783-ZMS8T8E2TGP, 1783-ZMS8T8E2TGN
8-port and 10-port Switches 1783-ZMS8TA, 1783-ZMS4T4E2TGP, 1783-ZMS4T4E2TGN
8.15 cm (3.2 in.)
9.9 cm (3.8 in.)
6.80 cm (2.68 in.)
8.63 cm (3.4 in.)
All Switches 1.03 cm (0.409 in.) 0.71 cm (0.28 in.)
24.84 cm (9.77 in.)
24.84 cm (9.77 in.)
32496
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
45