Page 28

Stratix Ethernet Device Specifications

Table 18 - Certifications - Stratix 5410 Switches Certifications (when product is marked)(1)

Stratix 5410 Switches c-UL-us

UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. UL Listed for Class I, Zone 2 Hazardous Locations, certified for U.S. and Canada. See UL File E194810. • Class 1, Zone 2, Ex nA nC IIC T4 Gc X • Class 1, Zone 2, AEx nA nC IIC T4 Gc

CE

European Union 1999/5/EC R&TTE Directive, compliant with: • EN 61000-6-2; Industrial Immunity • EN 61000-6-4; Industrial Emissions • EN 300 440-2 V1.4.1; ERM, SRD • EN 301 489-1 V1.9.2; ERM, EMC • EN 301 489-3 V1.6.1; ERM, EMC, SRD • EN 60950-1; Information Technology Equipment European Union 2011/65/EU RoHS, compliant with: • EN 50581; Technical Documentation

RCM

Australian Radiocommunications Act, compliant with: EN 61000-6-4; Industrial Emissions

Ex

European Union 94/9/EC ATEX Directive, compliant with: • EN 60079-0; General Requirements • EN 60079-15; Potentially Explosive Atmospheres, Protection "n" • Ex nA nC IIC T4 Gc • DEMKO15ATEX1492X

KC

Korean Registration of Broadcasting and Communications Equipment, compliant with: • Article 58-2 of Radio Waves Act, Clause 3

EtherNet/IP

ODVA conformance tested to EtherNet/IP specifications

RED

Hereby, Rockwell Automation declares that the radio equipment type Stratix 5410 is in compliance with Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.rockwellautomation.com

(1) See the Product Certification link at http://www.ab.com for declarations of conformity, certificates, and other certification details.

28

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

Page 29

Stratix Ethernet Device Specifications

Dimensions - Stratix 5410 Switches To prevent the switch from overheating, observe the following minimum clearances: • Top and bottom: 44.45 mm (1.75 in.) • Sides: 50.8 mm (2.0 in.) • Front: 50.8 mm (2.0 in.) These diagrams are representative of the Stratix 5410 switches. Actual faceplates vary depending on the catalog number.

44.5 cm (17.75 in.) 1 2

3

4

5 6

1

7 8 9 10 11 12 25 26

2

4

10/100/1000 PoE+

5

8

9

12

Disp. Mode

PoE

DLR

2

PRP

1

Out

1

Speed

Duplex

GPS

4

Setup

3

EIP Net

TimeCD

13 14 15 16 17 18 19 20 21 22 23 24 27 28 EIP Mod

4.45 cm (1.75 in.)

IN

IN

OUT

OUT

GPS ANT.

DIG.TimeCode

ANA.TimeCode

25

100/1000 SFP+

28

TOD

Express Setup

Alarms PSU

13

16

17

100/1000 SFP

20

21

24

Console

Alarm

35.6 cm (14.0 in.)

32564-M

46.53 cm (18.32 in.) 1

3.18 cm (1.25 in.)

2

3

4

5

6

7

8

4

5

10/100/1000 PoE+

8

9

12

IN

Disp. Mode

IN

OUT

PoE

PRP

DLR

Duplex

Out

2 1

2 4

Alarms PSU

Speed

1 3

TimeCD

GPS

Setup

EIP Net

EIP Mod

1

9 10 11 12 25 26

13 14 15 16 17 18 19 20 21 22 23 24 27 28

OUT

GPS ANT.

DIG.TimeCode

ANA.TimeCode

25

100/1000 SFP+

28

TOD

Express Setup

13

16

17

100/1000 SFP

20

21

24

.61 cm (.24 in.)

Console

Alarm

32565-M

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

29

Page 30

Stratix Ethernet Device Specifications

3.28 cm (1.29 in.) 0.56 cm (0.22 in.) 3.63 cm (1.43 in.)

3.63 cm (1.43 in.)

53.8 cm (21.18 in.) 46.53 cm (18.32 in.)

16.59 cm (6.53 in.)

17.66 cm (6.95 in.) 32564-M

30

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

Page 31

Stratix Ethernet Device Specifications

Stratix 5700 Ethernet Managed Switches Cat. No.

Total Ports

RJ45 Ports(1) Combo Ports

(PoE/PoE+)

SFP Slots

Firmware Type

CIP Sync NAT (IEEE 1588)

DLR

Conformal Coating

1783-BMS4S2SGL

6, - - 4 FE + 2 GE

Lite, - - - 1783-BMS4S2SGA

6, - - 4 FE + 2 GE

Full, - - - 1783-BMS06SL

6

4 FE, - 2 FE

Lite, - - - 1783-BMS06SA

6

4 FE, - 2 FE

Full, - - - 1783-BMS06TL

6

6 FE, - - Lite, - - - 1783-BMS06TA

6

6 FE, - - Full, - - - 1783-BMS06SGL

6

4 FE, - 2 GE

Lite, - - - 1783-BMS06SGA

6

4 FE, - 2 GE

Full, - - - 1783-BMS06TGL

6

4 FE + 2 GE, - - Lite, - - - 1783-BMS06TGA

6

4 FE + 2 GE, - - Full, - - - 1783-BMS10CL

10

8 FE

2 FE, - Lite, - - - 1783-BMS10CA

10

8 FE

2 FE, - Full, - - - 1783-BMS10CGL

10

8 FE

2 GE, - Lite, - - - 1783-BMS10CGA

10

8 FE

2 GE, - Full, - - - 1783-BMS10CGP

10

8 FE

2 GE, - Full

Yes, Yes, 1783-BMS10CGN

10

8 FE

2 GE, - Full

Yes

Yes

Yes, 1783-BMS12T4E2CGL

18

12 FE

2 GE

4 FE, Lite, - Yes, 1783-BMS12T4E2CGP

18

12 FE

2 GE

4 FE, Full

Yes, Yes, 1783-BMS12T4E2CGNK 18

12 FE

2 GE

4 FE, Full

Yes

Yes

Yes

Yes

1783-BMS20CL

20

16 FE

2 FE, 2 FE

Lite, - Yes, 1783-BMS20CA

20

16 FE

2 FE, 2 FE

Full, - Yes, 1783-BMS20CGL

20

16 FE

2 GE, 2 FE

Lite, - Yes, 1783-BMS20CGP

20

16 FE

2 GE, 2 FE

Full

Yes, Yes, 1783-BMS20CGN

20

16 FE

2 GE, 2 FE

Full

Yes

Yes

Yes, 1783-BMS20CGPK

20

16 FE

2 GE, 2 FE

Full

Yes, Yes

Yes

(1) FE = Fast Ethernet; GE = Gigabit Ethernet.

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

31

Page 32

Stratix Ethernet Device Specifications

Table 19 - Technical Specifications - Stratix 5700 Switches 1783-BMS10CL, 1783-BMS10CA, 1783-BMS10CGL, 1783-BMS10CGA

1783-BMS20CL, 1783-BMS20CA, 1783-BMS10CGN, 1783-BMS20CGL, 1783-BMS10CGP 1783-BMS20CGP, 1783-BMS20CGN, 1783-BMS20CGPK

Attribute

1783-BMS06SL, 1783-BMS06SA, 1783-BMS06TL, 1783-BMS06TA, 1783-BMS06SGL, 1783-BMS06SGA, 1783-BMS06TGL, 1783-BMS06TGA

Alarm relay

1 A @ 30V DC or 0.5 A @ 48V DC

Power input

0.5…2.0 A max @ 12…48V DC Class 2/SELV

Power consumption

9.5 W @ 24V DC @ 40 °C (104 °F) 15 W max

12.5 W @ 24V DC/ 40 °C (104 °F) 17 W max

Power dissipation

15 W

17 W

Isolation voltage

50V (continuous), basic insulation type, DC power ports to ground, DC power ports to Ethernet ports, and DC power ports to alarm ports No isolation between individual Ethernet ports No isolation between console port and system Type tested at 850V DC for 60 s

60V (continuous), basic insulation type, DC power ports to ground, alarm ports to ground, and DC power ports to alarm ports No isolation between console port and system Type tested at 707V DC for 60 s

Wire size, Ethernet connection(1)

RJ45 connector according to IEC 60603-7, 2- or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702, Wire size, DC power connection

0.5…0.8 mm2 (20…18 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater, 1.2 mm (3/64 in.) insulation max, 6.3 mm (0.25 in.) ±0.5 mm (0.02 in.) strip length

Wire size, alarm connection

0.5…0.8 mm2 (20…18 AWG) solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire, 6.3 mm (0.25 in.) ±0.5 mm (0.02 in.) strip length

Wire size, ground connection

4.0 mm2 (12 AWG) min, stranded copper wire

Screw torque, power and alarm terminals

0.23 N•m (2.0 in•lb)

0.23 N•m (2.0 in•lb)

Screw torque, ground terminal, max

0.96 N•m (8.5 in•lb)

0.4 N•m (3.5 in•lb)

Weight, approx

1.11 kg (2.45 lb)

Wiring category(2)

3 - on console and alarm ports 2 - on DC power ports 2 - on Ethernet ports

Enclosure type rating

None (open-style)

Pilot duty rating

Alarm not rated

North American temp code

T4

IEC temp code

T4

32

1.25 kg (2.75 lb)

1783-BMS4S2SGL, 1783-BMS4S2SGA

0.5…3.0 A max @ 12…48V DC Class 2/SELV

0.5…2.0 A max @ 12…48V DC Class 2/SELV

15 W @ 24V DC/ 40 °C (104 °F) 20 W max

21 W @ 24V DC/40 °C (104 °F) 30 W max

12.5 W @ 24V DC/40 °C (104 °F) 14 W max

20 W

30 W

14 W

1.38 kg (3.05 lb)

2.04 kg (4.50 lb)

1.22 kg (2.69 lb) 3 - on console ports 2 - on DC power and alarm ports

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

Page 33

Stratix Ethernet Device Specifications

Table 19 - Technical Specifications - Stratix 5700 Switches (continued) 1783-BMS10CL, 1783-BMS10CA, 1783-BMS10CGL, 1783-BMS10CGA

Attribute

1783-BMS06SL, 1783-BMS06SA, 1783-BMS06TL, 1783-BMS06TA, 1783-BMS06SGL, 1783-BMS06SGA, 1783-BMS06TGL, 1783-BMS06TGA

SFP modules(3)

1783-SFP100FX 1783-SFP100LX 1783-SFP100EXC 1783-SFP100ZXC 1783-SFP100T(4) 1783-SFP1GSX(5) 1783-SFP1GLX(5) 1783-SFP1GEXE(5) 1783-SFP1GZX(5) 1783-SFP1GTE(5)

Memory card

1784-SD1

Industry standards

Substation KEMA (IEEE 1613, IEC 61850 - 3) IEEE 1613 Electric Power Stations Communications Networking IEC 61850-3 Electric Substations Communications Networking

(1) (2) (3) (4) (5)

1783-BMS20CL, 1783-BMS20CA, 1783-BMS10CGN, 1783-BMS20CGL, 1783-BMS10CGP 1783-BMS20CGP, 1783-BMS20CGN, 1783-BMS20CGPK

1783-BMS4S2SGL, 1783-BMS4S2SGA

See page 71 for recommended products. Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. SFP modules are supported only on switches with combo ports or SFP slots. For SFP specifications, see page 69. The 1783-SFP100T module requires Stratix 5700 firmware revision 8.001or later. Gigabit Ethernet (GE) SFP modules work only in GE SFP slots. For a list of Stratix 5700 catalog numbers with GE SFP slots, see page 31.

Table 20 - Environmental Specifications - Stratix 5700 Switches

Attribute

1783-BMS06SL, 1783-BMS06SA, 1783-BMS06TL, 1783-BMS06TA, 1783-BMS06SGL, 1783-BMS06SGA, 1783-BMS06TGL, 1783-BMS06TGA, 1783-BMS10CL, 1783-BMS10CA, 1783-BMS10CGL, 1783-BMS10CGA, 1783-BMS10CGN, 1783-BMS10CGP, 1783-BMS20CL, 1783-BMS20CA, 1783-BMS20CGL, 1783-BMS20CGP, 1783-BMS20CGN, 1783-BMS20CGPK

Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock)

-40…+60 °C (-40…+140 °F)

Temperature, surrounding air, max

60 °C (140 °F)

Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)

-40…85 °C (-40…185 °F)

Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)

5…95% noncondensing

Vibration IEC 60068-2-6 (Test Fc, Operating)

2 g @ 10…500 Hz

Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock)

30 g

Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock)

55 g

1783-BMS4S2SGL, 1783-BMS4S2SGA

50 g

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

33

Page 34

Stratix Ethernet Device Specifications

Table 20 - Environmental Specifications - Stratix 5700 Switches (continued)

Attribute

1783-BMS06SL, 1783-BMS06SA, 1783-BMS06TL, 1783-BMS06TA, 1783-BMS06SGL, 1783-BMS06SGA, 1783-BMS06TGL, 1783-BMS06TGA, 1783-BMS10CL, 1783-BMS10CA, 1783-BMS10CGL, 1783-BMS10CGA, 1783-BMS10CGN, 1783-BMS10CGP, 1783-BMS20CL, 1783-BMS20CA, 1783-BMS20CGL, 1783-BMS20CGP, 1783-BMS20CGN, 1783-BMS20CGPK

Emissions CISPR11 (IEC 61000-6-4)

Class A

ESD immunity IEC 61000-4-2

8 kV contact discharges 15 kV air discharges

Radiated RF immunity IEC 61000-4-3

20V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 20V/m with 1 kHz sine-wave 80% AM from 80…1000 MHz 10V/m with 200 Hz 50% pulse 100% AM at 900 MHz 20V/m with 200 Hz 50% pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% pulse 100% AM at 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 1000…2700 MHz 20V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz

EFT/B immunity IEC 61000-4-4

±4 kV at 5 kHz and ±2 kV at 100 kHz on DC power ports ±4 kV at 2.5 kHz, ±2 kV at 5 kHz, and ±1 kV at 100 kHz on alarm ports ±4 kV at 2.5 kHz, ±2 kV at 5 kHz, and ±1 kV at 100 kHz on Ethernet ports

±4 kV at 2.5, 5, and 100 kHz on DC power ports ±4 kV at 2.5, 5, and 100 kHz on alarm ports

±1 kV line-line (DM) and ±2 kV line-earth (CM) on DC power ports ±2 kV line-earth (CM) on Ethernet ports

±1 kV line-line (DM) and ±2 kV line-earth (CM) on DC power ports ±1 kV line-line (DM) and ±2 kV line-earth (CM) on alarm ports

Surge transient immunity IEC 61000-4-5

1783-BMS4S2SGL, 1783-BMS4S2SGA

6 kV contact discharges 8 kV air discharges

Conducted RF immunity IEC 61000-4-6

10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz

Magnetic field immunity IEC 61000-4-8, 300A/m long duration at 50 and 60 Hz 1000A/m short duration at 50 and 60 Hz

Magnetic pulse immunity IEC 61000-4-9, 300A/m pulse

Voltage variation IEC 61000-4-29

10 ms interruption on DC power ports

Damped oscillatory wave immunity IEC 61000-4-18

±1 kV line-line (DM) and ±2.5 kV line-earth (CM) on power ports

Environmental rating

IP30

34

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

±1 kV line-line (DM) and ±2.5 kV line-earth (CM) on DC power ports at 1 MHz and 100 kHz ±1 kV line-line (DM) and ±2.5 kV line-earth (CM) on alarm ports at 1 MHz and 100 kHz

Page 35

Stratix Ethernet Device Specifications

Stratix 5700 Power over Ethernet Switches Table 21 - Technical Specifications - Stratix 5700 Power over Ethernet Switches Attribute

1783-BMS12T4E2CGL, 1783-BMS12T4E2CGP, 1783-BMS12T4E2CGNK

Ethernet data rate

10/100 Mbps

Alarm relay

30V DC, 1 A or 48V DC, 0.5 A

Power input

12...48V DC, 0.5…3.0 A max , Class 2/SELV

Power over Ethernet input power Power consumption

(1)

48V DC for PoE; 54V DC for PoE+ or a combination of PoE and PoE+ 15 W @ 24V DC 40 °C (104 °F), 30 W max

Power dissipation

30 W

Isolation voltage

60V (continuous), basic insulation type, DC power ports to ground, and PoE power ports to ground No isolation between individual Ethernet ports No isolation between PoE power and Ethernet ports No isolation between console port and system Type tested at 1585V DC for 60 s

Wire size, Ethernet connection(2)

RJ45 connector according to IEC 60603-7, 2- or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702

Wire size, DC power connection

0.5…0.8 mm2 (20…18 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater, 1.2 mm (3/64 in.) insulation max, 6.3 mm (0.25 in.) ±0.5 mm (0.02 in.) strip length

Wire size, alarm connection

0.5…0.8 mm2 (20…18 AWG) solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire, 6.3 mm (0.25 in.) ±0.5 mm (0.02 in.) strip length

Wire size, ground connection

4.0 mm2 (12 AWG) min, stranded copper wire

Screw torque, power and alarm terminals 0.23 N•m (2.0 in•lb) Screw torque, ground terminals, max

0.96 N•m (8.5 in•lb)

Weight, approx

1.11 kg (2.45 lb)

Wiring category(3)

3 - on console and alarm ports 2 - on DC power ports 2 - on Ethernet ports

Pilot duty rating

Alarm not rated

Enclosure type rating

None (open-style)

North American temp code

T4

IEC temp code

T4

SFP modules(4)

1783-SFP100FX 1783-SFP100LX 1783-SFP100EXC 1783-SFP100ZXC 1783-SFP100T(5) 1783-SFP1GSX(6) 1783-SFP1GLX(6) 1783-SFP1GEXE(6) 1783-SFP1GZX(6) 1783-SFP1GTE(6)

Memory card

1784-SD1

Industry standards

Substation KEMA (IEEE 1613, IEC 61850 - 3) IEEE 1613 Electric Power Stations Communications Networking IEC 61850-3 Electric Substations Communications Networking

(1) (2) (3) (4) (5) (6)

For PoE configurations, the power consumption values listed represent the highest values that can be configured using all ports. A general guideline is 0.5 W per 30 W PoE+ port used. See page 71 for recommended products. Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. SFP modules are supported only on switches with combo ports or SFP slots. For SFP specifications, see page 69. The 1783-SFP100T module requires Stratix 5700 firmware revision 8.001or later. Gigabit Ethernet (GE) SFP modules work only in GE SFP slots. For a list of Stratix 5700 catalog numbers with GE SFP slots, see page 31.

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018

35

Page 36

Stratix Ethernet Device Specifications

Table 22 - Environmental Specifications - Stratix 5700 Power over Ethernet Switches Attribute

1783-BMS12T4E2CGL, 1783-BMS12T4E2CGP, 1783-BMS12T4E2CGNK

Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock)

-40…+60 °C (-40…+140 °F)

Temperature, surrounding air, max

60 °C (140 °F)

Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)

-40…+85 °C (-40…+185 °F)

Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)

5…95% noncondensing

Vibration IEC 60068-2-6 (Test Fc, Operating)

2 g @ 10…500 Hz

Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock)

30 g

Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock)

50 g

Emissions CISPR11 (IEC 61000-6-4)

Class A

ESD immunity IEC 61000-4-2

6 kV contact discharges 8 kV air discharges

Radiated RF immunity IEC 61000-4-3

10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% pulse 100% AM at 1890 MHz 1V/m with 1 kHz sine-wave 80% AM from 1000…2700 MHz

EFT/B immunity IEC 61000-4-4

±4 kV at 5 kHz on DC power ports ±4 kV at 5 kHz on alarm ports ±4 kV at 5 kHz on Ethernet ports

Surge transient immunity IEC 61000-4-5

±1 kV line-line (DM) and ±2 kV line-earth (CM) on DC power ports ±2 kV line-earth (CM) on Ethernet ports

Conducted RF immunity IEC 61000-4-6

10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz

Damped oscillatory wave immunity IEC 61000-4-18

±1 kV line-line (DM) and ±2.5 kV line-earth (CM) on power ports

36