The text of a spec sheet · part 7 of 8
Stratix Ethernet Device Specifications, pages 55 to 63
Pages 55 to 63 of 72
The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 1783-US08T
Page 55
Stratix Ethernet Device Specifications
Dimensions - Stratix 8000 and Stratix 8300 Switches This illustration shows dimensions for the 1783-MS10T switch and the 1783-MX08T expansion module. Dimensions for the other switches are the same as the 1783-MS10T switch. Dimensions for the other expansion modules are the same as the 1783-MX08T expansion module. Airflow around the switch and through the vents is unrestricted. To prevent the switch from overheating, these minimum clearances must be met: • Top and bottom: 105 mm (4.13 in.) • Left and right: 90 mm (3.54 in.) • Front: 65 mm (2.56 in.) Switch and Expansion Module
Switch and Expansion Module (mated) 9.71 cm (3.82 in.)
15.3 cm (6.03 in.)
24.3 cm (9.57 in.)
14.8 cm (5.83 in.)
33.27 cm (13.1 in.)
9.81 cm (3.87 in.)
11.1 cm (4.38 in.)
Switch (side view)
Switch and Expansion Modules (mated)
11.75 cm (4.63 in.) 31801-M
For panel-mounting, the height of the center of the mounting holes on both the top and bottom latches measures 8.73 mm (0.34 in.) above the top surface (or below the bottom surface) of the switch. On the switch base unit, the tab hole center-to-center spacing is 6.83 cm (2.69 in.). For expansion modules, the tab hole center-to-center spacing is 4.36 cm (1.72 in.).
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
55
Page 56
Stratix Ethernet Device Specifications
Stratix 5100 Wireless Access Point/Workgroup Bridge Table 38 - Technical Specifications - Stratix 5100 Wireless Access Point/Workgroup Bridge Attribute
1783-WAPBK9 United States
1783-WAPAK9 Canada/Latin America
1783-WAPEK9 European Union
1783-WAPZK9 Australia/New Zealand
1783-WAPCK9 China
Dimensions (LxWxD)
22.04 x 22.04 x 4.67 cm (8.68 x 8.68 x 1.84 in.)
22.04 x 22.04 x 4.67 cm (8.68 x 8.68 x 1.84 in.)
22.04 x 22.04 x 4.67 cm (8.68 x 8.68 x 1.84 in.)
22.04 x 22.04 x 4.67 cm (8.68 x 8.68 x 1.84 in.)
22.04 x 22.04 x 4.67 cm (8.68 x 8.68 x 1.84 in.)
Weight
1.22 kg (2.7 lb)
1.22 kg (2.7 lb)
1.22 kg (2.7 lb)
1.22 kg (2.7 lb)
1.22 kg (2.7 lb)
Power input
48V DC, 350 mA
48V DC, 350 mA
48V DC, 350 mA
48V DC, 350 mA
48V DC, 350 mA
Power consumption
12.95 W
12.95 W
12.95 W
12.95 W
12.95 W
Power dissipation
12.95 W
12.95 W
12.95 W
12.95 W
12.95 W
Antennas
External
External
External
External
External
Power adapter
AIR-PWR-B Input: 100…240 50/60 Hz VAC Output: 48V DC, 380 mA
AIR-PWR-B Input: 100…240 50/60 Hz VAC Output: 48V DC, 380 mA
AIR-PWR-B Input: 100…240 50/60 Hz VAC Output: 48V DC, 380 mA
AIR-PWR-B Input: 100…240 50/60 Hz VAC Output: 48V DC, 380 mA
AIR-PWR-B Input: 100…240 50/60 Hz VAC Output: 48V DC, 380 mA
Table 39 - Environmental Specifications - Stratix 5100 Wireless Access Point/Workgroup Bridge Attribute
1783-WAPBK9
1783-WAPAK9
1783-WAPEK9
1783-WAPZK9
1783-WAPCK9
Temperature, operating
-20…+55 °C (-4…+131 °F)
-20…+55 °C (-4…+131 °F)
-20…+55 °C (-4…+131 °F)
-20…+55 °C (-4…+131 °F)
-20…+55 °C (-4…+131 °F)
Temperature, nonoperating/storage
-30…+85 °C (-22…+185 °F)
-30…+85 °C (-22…+185 °F)
-30…+85 °C (-22…+185 °F)
-30…+85 °C (-22…+185 °F)
-30…+85 °C (-22…+185 °F)
Relative humidity
10…90% noncondensing
10…90% noncondensing
10…90% noncondensing
10…90% noncondensing
10…90% noncondensing
Table 40 - Certifications - Stratix 5100 Wireless Access Point/Workgroup Bridge Catalog Number
Certifications (when product is marked)(1)
1783-WAPBK9 Regulatory Domain `B’
FCC ID: LDK102080
This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations.
1783-WAPAK9 Regulatory Domain `A’
Industry Canada: 2461B-102080
RSS-210 - License Exempt Radio Apparatus: Category I Equipment
1783-WAPEK9 Regulatory Domain `E’
CE
For use in the EU, Iceland, Liechtenstein, Norway, Switzerland, Turkey and all other Countries that recognize the EU Directive 1999/5/EC.
1783-WAPZK9 Regulatory Domain `Z’
For use in Australia, New Zealand and all other Countries that recognize the Radiocommunications (Short Range Devices) Standard. E134
1783-WAPCK9 Regulatory Domain `C’
CMIIT ID: 2014AJ2894
For use in China and all other Countries that recognize The Bureau of Radio Administration of MIIT (Fixed Radio Devices).
(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
56
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 57
Stratix Ethernet Device Specifications
Dimensions - Stratix 5100 Wireless Access Point/Workgroup Bridge 220.98 mm (8.7 in.)
53.59 mm (2.11 in.) 2.11
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
57
Page 58
Stratix Ethernet Device Specifications
Stratix 5900 Services Router Table 41 - Technical Specifications - Stratix 5900 Services Router Attribute
1783-SR
Input voltages
5V, 4 A Class 2 Requires LITEON PA-1220-1SA2 power adapter (100...240V AC, 50/60Hz, 0.8A)
Power consumption, max
11 W
Power dissipation
11 W
Isolation voltage
Not rated
Weight
1.5 kg (3.2 lb)
Wiring category(1)
3 - on power ports 2 - on Ethernet ports
Enclosure type rating
Meets IP41 (2)
Router AC Power Adapter Input voltage
85…264V AC 100…240V AC nom
Power consumption, max
25 W
Output power, max
20 W (5V DC, 4 A)
(1) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. (2) AC power adapter is not IP41 rated. Installation must include protection of the adapter and power plug from water.
Table 42 - Environmental Specifications - Stratix 5900 Services Router Attribute
1783-SR
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
-25…+60 °C (-13…+140 °F)
Temperature, surrounding air, max
60 °C (140 °F)
Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
-40…+85 °C (-40…+185 °F)
Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
5…95% noncondensing
Vibration IEC 60068-2-64 (Test Fh, Operating)
1.12 Grms random
Operating shock IEC 60068-2-27 (Test Ea, Unpackaged Shock)
15 g
Nonoperating shock IEC 60068-2-27 (Test Ea, Unpackaged Shock)
15 g
Emissions CISPR22 (IEC 61000-6-4)
Class B
ESD immunity IEC 61000-4-2
8 kV contact discharges 15 kV air discharges
Radiated RF immunity IEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
58
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 59
Stratix Ethernet Device Specifications
Table 42 - Environmental Specifications - Stratix 5900 Services Router (continued) Attribute
1783-SR
EFT/B immunity IEC 61000-4-4
±500 kV at 5 kHz on Ethernet ports
Surge transient immunity IEC 61000-4-5
±1 kV line-earth (CM) on shielded Ethernet port
Conducted RF immunity IEC 61000-4-6
10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Environmental rating
IP30
Table 43 - Certifications - Stratix 5900 Services Router Certifications (when product is marked)(1)
1783-SR c-UL-us
UL Listed Information Technology Equipment, certified for US and Canada. See UL File E136709.
CE
European Union 1999/5/EC R&TTE Directive, compliant with: • EN 55022; ITE Emissions • EN 55024; ITE Immunity • EN 60950; ITE Safety European Union 2011/65/EU RoHS, compliant with: • EN 50581; Technical documentation
C-Tick
Australian Radiocommunications Act, compliant with: • ACMA EMC Std 08
CCC
GB 4943. 1, GB 9254, YD/T993
KC
Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3
(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
Dimensions - Stratix 5900 Services Router 44 mm (1.73 in.) 206 mm (8.1 in.)
196 mm (7.7 in.)
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
59
Page 60
Stratix Ethernet Device Specifications
Stratix 5950 Security Appliance Table 44 - Technical Specifications - Stratix 5950 Security Appliance Attribute
1783-SAD4T0SBK9, 1783-SAD4T0SPK9, 1783-SAD2T2SBK9, 1783-SAD2T2SPK9
Power consumption
24 W
Power dissipation
24 W
Enclosure type rating
None (open-style)
Voltage and current ratings
12…48V DC, 2.0 A Max – User Supply Alarm relay: 30V DC, 1 A or 48V DC, 0.5 A
Isolation voltage
60V (continuous), Basic Insulation Type, all ports to Ground. No isolation between individual ports.
Wire size, Ethernet connection
RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702
Wire size, ground connection
4 mm2 (12…10 AWG) solid or stranded copper wire
Wire size, alarm connection
0.8…1.0 mm2 (18…16 AWG) solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire (such as Belden part number 9318), 6.3 mm (0.25 in.) ± 0.5 mm (0.02 in.) strip length
Wire size, DC power connection
0.8…1.0 mm2 (18…16 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater, 1.2 mm (3/64 in.) insulation max, 6.3 mm (0.25 in.) ± 0.5 mm (0.02 in.) strip length
Insulation stripping length
6.3 mm (0.25 in.) ± 0.5 mm (0.02 in.)
Wire type
Copper
Pilot duty rating
Alarm: Not rated
Wiring category(1)
3 - on Console ports 2 -on Power and Alarm ports 2 - on Ethernet ports
Voltage variation IEC 61000-4-29
30 % dip for 10 ms on DC supply ports 60 % dips for 100 ms and 1 s on DC supply ports 100 % dips for 10 ms and 5 s on DC supply ports
Alarm relay
30V DC, 1 A, or 48V DC, 0.5 A
Screw torque, ground terminal
0.4 N•m (3.5 Ib•in)
Screw torque, power terminal
0.56 N•m (5 Ib•in)
Screw torque, alarm terminal
0.56 N•m (5 Ib•in)
North American temp code
T4
ATEX temp code
T4
SFP modules
1783-SFP100FX 1783-SFP100LX 1783-SFP1GSX 1783-SFP1GLX
Memory card replacement
1784-SD1
(2)
(1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. (2) For SFP specifications, see page 69.
60
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 61
Stratix Ethernet Device Specifications
Table 45 - Environmental Specifications - Stratix 5950 Security Appliance Attribute
1783-SAD4T0SBK9, 1783-SAD4T0SPK9, 1783-SAD2T2SBK9, 1783-SAD2T2SPK9
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-40…+60 °C (-40…+140 °F)
Temperature, ambient, max
For UL certified enclosed equipment: 60 °C (140 °F)
Temperature, surrounding air, max
For UL certified enclosed equipment: 60 °C (140 °F)
Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock):
-40…+85 °C (-40…+185 °F)
Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
5…95% noncondensing
Vibration IEC 60068-2-6 (Test Fc, Operating)
1 g @ 5…150 Hz
Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
15 g
Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30 g
Emissions
IEC 61000-6-4
ESD Immunity IEC 61000-4-2
6 kV contact discharges 8 kV air discharges
Radiated RF Immunity IEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 1V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
EFT/B Immunity IEC 61000-4-4
±2 kV at 5 kHz on power ports ±2 kV at 5 kHz on signal ports ±2 kV at 5 kHz on communications ports
Surge Transient Immunity IEC 61000-4-5
±1 kV line-line(DM) and ±2 kV line-earth(CM) on power ports ±500V line-line(DM) and ±1 kV line-earth(CM) on signal ports ±2 kV line-earth(CM) on communications ports
Conducted RF Immunity IEC 61000-4-6
10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Damped Oscillatory Wave Immunity IEC 61000-4-18
±500V line-line(DM) and ±1 kV line-earth(CM) on signal ports ±1 kV line-line(DM) and ±2.5 kV line-earth(CM) on power ports ±500V line-earth(CM) on communication ports
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
61
Page 62
Stratix Ethernet Device Specifications
Table 46 - Certifications - Stratix 5950 Security Appliance Certifications (when product is marked)(1)
1783-SAD4T0SBK9, 1783-SAD4T0SPK9, 1783-SAD2T2SBK9, 1783-SAD2T2SPK9 c-UL-us
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584 UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. UL Listed for Class I, Zone 2 Hazardous Locations, certified for U.S. and Canada. See UL File E194810. • Class 1, Zone 2, Ex nA nC IIC T4 Gc X • Class 1, Zone 2, AEx nA nC IIC T4 Gc
CE
European Union 1999/5/EC R&TTE Directive, compliant with: • EN 61000-6-2; Industrial Immunity • EN 61000-6-4; Industrial Emissions European Union 2011/65/EU RoHS, compliant with: • EN 50581; Technical documentation
RCM
EN 61000-6-4; Industrial Emissions
Ex
EN 60079-0; General Requirements EN 60079-15; Potentially Explosive Atmospheres, Protection "n" Ex nA nC IIC T4 Gc DEMKO 15 ATEX 1595X
(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
Dimensions - Stratix 5950 Security Appliance 106.68 mm (4.2 in.)
R
129.54 mm (5.10 in.)
159.26 mm (6.27 in.) 32593-M
62
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 63
Stratix Ethernet Device Specifications
Embedded Switch Technology Table 47 - Technical Specifications - EtherNet/IP Taps Attribute
1783-ETAP
1783-ETAP1F
1783-ETAP2F
Description
EtherNet/IP tap 3 copper ports
EtherNet/IP tap • 2 copper ports • 1 fiber port
EtherNet/IP tap • 1 copper port • 2 fiber ports
Tap type
Copper
Fiber, single-port
Fiber, dual-port
Current consumption, max
125 mA @ 24V DC
200 mA @ 24V DC
260 mA @ 24V DC
DC power supply voltage rating
24V DC (20.4…27.6V DC) CL 2/SELV
Isolation voltage
30V (continuous), basic insulation type, network channels to power and network channels to network channels Type tested at 1250V DC for 60 s
Type tested at 853V AC for 60 s
Power consumption, max
3W
4.8 W
6.24 W
Power dissipation
3W
4.8 W
6.24 W
Wire size, Ethernet connection(1)
RJ45 connector according to IEC 60603-7, 2- or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702
Wire size, DC power connection
One 0.33…3.3 mm2 (22…12 AWG) or two 0.33…1.3 mm2 (22…16 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater, 1.2 mm (3/64 in.) insulation max
Screw torque, power terminal
0.6…0.8 N•m (5…7 in•lb)
Wiring category(2)
1 - on power ports 2 - on communication ports
Enclosure type rating
None (open-style)
North American temp code
T5
T4A
T4
IEC temp code
T5
T4
T4
(1) See page 71 for recommended products. (2) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Table 48 - Technical Specifications - EtherNet/IP Tap Fiber Connections Attribute
1783-ETAP1F, 1783-ETAP2F
Fiber transceiver type
100Base-FX IEEE802.3u
Optical wavelength
1310 nm no cap
Transmitter launch power at Beginning of Life (BOL), min Allow -1 dB at End of Life (EOL)
-19 dBm into 62.5/125 μm fiber, N/A = 0.275 -22.5 dBm into 50/125 μm fiber, N/A = 0.20
Receiver sensitivity, min
-31.8 dBm
Receiver sensitivity, max
-14 dBm
Fiber channel power budget at rated BER (2 connected taps, either 1783-ETAP1F or 1783-ETAP2F)
12.8 dB for 62.5/125 μm multimode fiber 9.3 dB for 50/125 μm multimode fiber
Fiber connection, glass
62.5/125 μm and 50/125 μm multimode fiber
Fiber connection, simplex or duplex
Jacket type and jacket diameter is dependent on connector selection
Fiber connection, graded index (GI)
Per IEC 60794-1-1, IEC 60793-2-10 category A1 fibers
Connector type
IEC 61754-20 LC connector, maximum insertion loss 0.75 dB per connection
Channel length, max
2 km (1.24 mi) (1)
(1) The channel (connectors and cable) must not exceed the allowable power budget.
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
63