Page 64
Stratix Ethernet Device Specifications
Table 49 - Environmental Specifications - EtherNet/IP Taps Attribute
1783-ETAP
1783-ETAP1F, 1783-ETAP2F
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold) IEC 60068-2-2 (Test Bd, Operating Dry Heat) IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
-25…+70 °C (-13…+158 °F)
-25…+60 °C (-13…+140 °F)
Temperature, surrounding air, max
70° C (158 °F)
60° C (140 °F)
Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold) IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat) IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
-40…+85 °C (-40…+185 °F)
Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
5…95% noncondensing
Vibration IEC 60068-2-6 (Test Fc, Operating)
5 g @ 10…500 Hz
Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30 g
Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
50 g
Emissions CISPR11 (IEC 61000-6-4)
Class A
ESD immunity IEC 61000-4-2
6 kV contact discharges 8 kV air discharges
Radiated RF immunity IEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
EFT/B immunity IEC 61000-4-4
±4 kV at 5 kHz on power ports ±3 kV at 5 kHz on communication ports
Surge transient immunity IEC 61000-4-5
±1 kV line-line (DM) and ±2 kV line-earth (CM) on power ports ±2 kV line-earth (CM) on communication ports
Conducted RF immunity IEC 61000-4-6
10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Voltage variation IEC 61000-4-29
10 ms interruption on DC supply ports
64
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 65
Stratix Ethernet Device Specifications
Table 50 - Certifications - EtherNet/IP Taps Certification(1)
1783-ETAP c-UL-us
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810.
CE
European Union 2004/108/EC EMC Directive, compliant with: • EN 61326-1; Meas./Control/Lab., Industrial Requirements • EN 61000-6-2; Industrial Immunity • EN 61000-6-4; Industrial Emissions • EN 61131-2; Programmable Controllers (Clause 8, Zone A and B) European Union 2011/65/EU RoHS, compliant with: • EN 50581; Technical Documentation
C-Tick
Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions
Ex
European Union 94/9/EC ATEX Directive, compliant with: • EN 60079-15; Potentially Explosive Atmospheres, Protection “n” • EN 60079-0; General Requirements • II 3 G Ex nA IIC T5 X
KC
Korean Registration of Broadcasting and Communications Equipment, compliant with: • Article 58-2 of Radio Waves Act, Clause 3
EtherNet/IP
ODVA conformance tested to EtherNet/IP specifications
1783-ETAP1F, 1783-ETAP2F
European Union 94/9/EC ATEX Directive, compliant with: • EN 60079-15; Potentially Explosive Atmospheres, Protection “n” • EN 60079-0; General Requirements • II 3 G Ex nA IIC T4 X
(1) When product is marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
Dimensions, EtherNet/IP Taps This illustration shows dimensions for the 1783-ETAP tap. The dimensions for the 1783-ETAP1F and 1783-ETAP2F taps are the same.
122.68 mm (4.83 in.) 131.57 mm (5.18 in.)
104.9 mm (4.13 in.)
35.05 mm (1.38 in.)
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
65
Page 66
Stratix Ethernet Device Specifications
Configurable NAT Router Table 51 - Technical Specifications - Configurable NAT Router Attribute
1783-NATR
Enclosure type rating
None (open-style)
Voltage and current ratings
DC power supply input: 20.4…27.6V DC/limited voltage Current rating: 150 mA
Power consumption, max
3W
Isolation voltage
Functional insulation type (IEC-61010-2-201), Ethernet Ports to Power ports
Wire size, power connection
Single wire: 0.33…3.3 mm2 (22…12 AWG) stranded copper wire rated at 75 °C (167 °F), or greater, 1.2 mm (3/64 in.) insulation max Double wire: 0.33…1.3 mm2 (22…16 AWG) solid copper wire rated at 75 °C (167 °F), or greater, 1.2 mm (3/64 in.) insulation max
Wiring category(1)
2 - on power ports 2 - on Ethernet ports
North American temp code
T4
ATEX temp code
T4
IECEx temp code
T4
(1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Table 52 - Environmental Specifications - Configurable NAT Router Attribute
1783-NATR
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold) IEC 60068-2-2 (Test Bd, Operating Dry Heat) IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
-25…+70 °C (-13…+158 °F)
Temperature, surrounding air, max
70 °C (158 °F)
Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold) IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat) IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
-40…+85 °C (-40…+185 °F)
Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
5…95% noncondensing
Vibration IEC 60068-2-6 (Test Fc, Operating)
5 g @ 10…500 Hz
Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30 g
Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
50 g
Emissions
IEC 61000-6-4
ESD immunity IEC 61000-4-2
6 kV contact discharges 8 kV air discharges
Radiated RF immunity IEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% pulse 100% AM at 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
66
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 67
Stratix Ethernet Device Specifications
Table 52 - Environmental Specifications - Configurable NAT Router (continued) Attribute
1783-NATR
EFT/B immunity IEC 61000-4-4
±2 kV at 5 kHz on power ports ±2 kV at 5 kHz on Ethernet ports
Surge transient immunity IEC 61000-4-5
±1 kV line-line (DM) and ±2 kV line-earth (CM) on power ports ±2 kV line-earth (CM) on Ethernet ports
Conducted RF immunity IEC 61000-4-6
10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Table 53 - Certifications - Configurable NAT Router Certification(1)
1783-NATR c-UL-us
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810.
CE
European Union 2004/108/EC EMC Directive, compliant with: • EN 61326-1; Meas./Control/Lab., Industrial Requirements • EN 61000-6-2; Industrial Immunity • EN 61000-6-4; Industrial Emissions • EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)
RCM
Australian Radiocommunications Act, compliant with: EN 61000-6-4; Industrial Emissions
Ex
European Union 94/9/EC ATEX Directive, compliant with: • EN 60079-0; General Requirements • EN 60079-15; Potentially Explosive Atmospheres, Protection "n" • II 3 G Ex nA IIC T4 Gc • DEMKO 15 ATEX 1459X
IECEx
IECEx System, compliant with: • IEC 60079-0; General Requirements • IEC 60079-15; Potentially Explosive Atmospheres, Protection "n" • II 3 G Ex nA IIC T4 Gc • IECEx UL 15.0026X
KC
Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3
EtherNet/IP
ODVA conformance tested to EtherNet/IP specifications
(1) When product is marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
67
Page 68
Stratix Ethernet Device Specifications
Dimensions - Configurable NAT Router This illustration shows dimensions for the 1783-NATR device. When mounting the 1783-NATR device, allow a minimum clearance between the device and adjacent equipment of 2.54 cm (1 in.) on all sides.
122.68 mm (4.83 in.) 131.57 mm (5.18 in.)
104.9 mm (4.13 in.)
35.05 mm (1.38 in.)
68
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 69
Stratix Ethernet Device Specifications
Accessories Small Form-factor Pluggable (SFP) Modules Table 54 - SFP Modules Cat. No.
Description
Interface Connector
Wavelength (nm)
1783-SFP100FX
100BASE-FX multimode fiber
Dual LC
1310
1783-SFP100LX
100BASE-LX singlemode fiber
Dual LC
1783-SFP100EXC
100BASE-EX singlemode fiber
1783-SFP100ZXC 1783-SFP100T(1)
1783-SFP1GSX
Core Size/ Cladding Size (micron)
Modal Bandwidth (MHz/km)
Cable Length
Commercial(5) 0 …+70 °C (+32 …+158 °F)
Extended(5) -5 …+85 °C (+23…+185 °F)
Industrial(5) -40 …+85 °C (-40…+185 °F)
DOM(6)
50/125
500, Yes
Yes
500
2 km (6562 ft), 62.5/125 1310
G.652, 10 km (32,808 ft), - Yes
Yes
Dual LC
1310
G.652(4), 40 km (131,234 ft)
Yes, - - 100BASE-ZX singlemode fiber
Dual LC
1550
G.652(4), 80 km (262,467 ft)
Yes, - - 100BASE-T copper
RJ-45, - - 100 m (328 ft), - Yes
62.5/125
160
220 m (722 ft)
62.5/125
200
275 m (902 ft), - Yes
Yes
50/125
400
500 m (1640 ft)
50/125
500
550 m (1804 ft) Yes
Yes
1000BASE-SX multimode fiber
Dual LC
850
1783-SFP1GLX
1000BASE-LX/LH singlemode fiber
Dual LC
1310
G.652, 10 km (32,808 ft), 1783-SFP1GEXE(2)
1000BASE-EX singlemode fiber
Dual LC
1310
G.652(4), 40 km (131,234 ft), 1783-SFP1GZX(3)
1000BASE-ZX singlemode fiber
Dual LC
1550
G.652(4), 70 km (229,659 ft), 1783-SFP1GTE
1000BASE-T copper
RJ-45, - - 100 m (328 ft), 62.5/125
160 (FDDI)
26 m (85 ft)
62.5/125
200 (OM1)
33 m (108 ft)
50/125
400
66 m (216 ft)
50/125
500 (OM2)
82 m (269 ft)
50/125
2000
300 m (984 ft)
50/125
4700
400 m (1312 ft)
G.652(4), 10 km (32,808 ft)
1783-SFP10GSRE
1783-SFP10GLRE
10GBASE-SR multimode fiber
10GBASE-LR singlemode fiber
Dual LC
Dual LC
850
1310
Yes
Yes Yes
Yes
Yes, - - Yes, Yes, Yes, Yes
(1) The 1783-SFP100T module requires Stratix 5400 or 5410 firmware revision 3.001or later, Stratix 5700 firmware revision 8.001or later, or Stratix 8000 firmware revision 12.001 or later. (2) The 1783-SFP1GEXE module operates on standard single-mode fiber-optic link spans of up to 40 km in length. For back-to-back connectivity, insert a 5-dB inline optical attenuator between the fiber-optic cable and the receiving port on the SFP module at each end of the link. (3) When shorter distances of single-mode fiber (SMF) are used, you can avoid overloading the receiver by inserting an inline optical attenuator in the link. If the fiber-optic cable span loss is less than 8 dB, insert a10-dB inline optical attenuator between the fiber-optic cable plant and the receiving port on the SFP module at each end of the link. (4) ITU-T G.652 SMF as specified by the IEEE 802.3z standard. (5) Once you install SFP modules in the switch, the overall temperature rating of the combined modules (switch and SFP modules) is limited to the lowest maximum temperature rating and the highest minimum temperature rating. (6) Digital Optical Monitoring (DOM) iis supported on the switches via the command-line interface (CLI).
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
69
Page 70
Stratix Ethernet Device Specifications
Table 55 - SFP and Switch Compatiblity Stratix 2000(3) (4) Stratix 5400
Cat. No.
Stratix 5410
Stratix 5700
Stratix 5950
Stratix 6000
Stratix 8000
Stratix 8300
1783-SFP100FX
X
X
X
X
X
X
X
1783-SFP100LX
X
X
X
X
X
X
X
1783-SFP100EXC
X
X
X
X
X
X
1783-SFP100ZXC
X
X
X
X
X
X
X
X
X
X
1783-SFP100T
(1) (2)
X
X
X
X
X
X
X
X
(2)
X
X
X
X
X
X
X
X
(2)
X
X
X
X
X
X
(2)
X
X
X
X
X
X
X
X
X
X
X
1783-SFP1GSX 1783-SFP1GLX
1783-SFP1GEXE 1783-SFP1GZX 1783-SFP1GTE
(2)
1783-SFP10GSRE
X
1783-SFP10GLRE
X
(1) The 1783-SFP100T module requires Stratix 5400 or 5410 firmware revision 3.001or later, Stratix 5700 firmware revision 8.001or later, or Stratix 8000 firmware revision 12.001 or later. (2) Gigabit Ethernet (GE) SFP modules work only in GE SFP slots. (3) The SFP modules shown in this table for Stratix 2000 switches must be ordered separately and are not the same as the preinstalled SFP modules that ship with the switches. (4) Stratix 2000 catalog number 1783-US6TG2CG/A supports only Gigabit Ethernet (GE) SFP modules 1783-SFP1GSX,1783-SFP1GLX, 1783-SFP1GEXE, and 1783-SFP1GZX.
Memory Cards Cat. No.
Description
Compatibility
1784-SD1
1 GB industrial SD card
Stratix 5700 Stratix 5950
1783-MCF
Stratix 8000 CompactFlash card (spare)
Stratix 8000
1783-RMCF
Stratix 8300 CompactFlash card (spare)
Stratix 8300
70
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 71
Stratix Ethernet Device Specifications
Ethernet Cables Cat. No. Industrial Ethernet Patchcords
Category
Description
(1)
RJ45 to RJ45 1585J-M8TBJM-2
Male RJ45 to male RJ45, unshielded twisted pair, teal, high-flex TPE, 8-conductor (4-pair), 2 m (6.56 ft) cable
1585J-M4TBJM-2
Male RJ45 to male RJ45, unshielded twisted pair, teal, high-flex TPE, 4-conductor (2-pair), 2 m (6.56 ft) cable
1585J-M8UBJM-2
Male RJ45 to male RJ45, foil and braided shield, teal, high-flex PUR, 8-conductor (4-pair), 2 m (6.56 ft) cable
1585J-M4UBJM-2
Category 5
1585J-M8PBJM-2
Male RJ45 to male RJ45, foil and braided shield, teal, high-flex PUR, 4-conductor (2-pair), 2 m (6.56 ft) cable Male RJ45 to male RJ45, unshielded twisted pair, teal, riser PVC, 8-conductor (4-pair), 2 m (6.56 ft) cable
1585J-M4PBJM-2
Male RJ45 to male RJ45, unshielded twisted pair, teal, riser PVC, 4-conductor (2-pair), 2 m (6.56 ft) cable
1585J-M8HBJM-2
Male RJ45 to male RJ45, foil shield, teal, 600V PVC, 8-conductor (4-pair), 2 m (6.56 ft) cable
1585J-M4HBJM-2
Male RJ45 to male RJ45, foil shield, teal, 600V PVC, 4-conductor (2-pair), 2 m (6.56 ft) cable
1585J-M8TGJM-2
Category 6
Male RJ45 to male RJ45, foil shield, teal, high-flex TPE, 8-conductor (4-pair), 2 m (6.56 ft) cable
M12 to M12, D-code 1585D-M4TBDM-2
M12 D-code to M12 D-code, unshielded twisted pair, teal, high-flex TPE, 4-conductor (2-pair), 2 m (6.56 ft) cable
1585D-M4UBDM-2
Category 5e
1585D-M4PBDM-2
M12 D-code to M12 D-code, foil and braided shield, teal, high-flex PUR, 4-conductor (2-pair), 2 m (6.56 ft) cable M12 D-code to M12 D-code, foil and braided shield, teal, riser PVC, 4-conductor (2-pair), 2 m (6.56 ft) cable
M12 X-code to M12 X-code 1585D-M8TGDM-2 Industrial Ethernet Cable Spools
Category 6
1585-C8TB-S100 1585-C8UB-S100 1585-C8PB-S100
M12 X-code to M12 X-code, foil and braided shield, teal, high-flex TPE, 8-conductor (4-pair), 2 m (6.56 ft) cable
(2)
Cable spool, unshielded twisted pair, teal, high-flex TPE, 8-conductor (4-pair), 100 m (328.08 ft) Category 5e
1585-C8HB-S100
Cable spool, foil and braided shield, teal, high-flex PUR, 8-conductor (4-pair), 100 m (328.08 ft) Cable spool, unshielded twisted pair, teal, riser PVC, 8-conductor (4-pair), 100 m (328.08 ft) Cable spool, foil shield, teal, 600V PVC, 8-conductor (4-pair), 100 m (328.08 ft)
Accessories 1585J-M8CC-H 1585D-M4DC-H 1585D-M4DC-SH
RJ45 IDC connector Category 5e
M12 D-code IDC connector M12 D-code IDC connector compatible with 600V cable spools
(1) Patchcords are available in lengths of up to 80 m (262.46 ft) in 0.1 m (0.328 ft) increments. Refer to http://www.ab.com/catalogs for full product offering. (2) Cable spools are available in 100,300 m (328.08 ft) and 600 m (1968.5 ft) lengths.
For additional Ethernet media choices, see On-Machine™ Connectivity Catalog, publication M117-CA001.
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
71
Page 72
Rockwell Automation Support Use the following resources to access support information.
Technical Support Center
Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates.
www.rockwellautomation.com/knowledgebase
Local Technical Support Phone Numbers
Locate the phone number for your country.
www.rockwellautomation.com/global/support/get-supportnow.page
Direct Dial Codes
Find the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer.
www.rockwellautomation.com/global/support/directdial.page
Literature Library
Installation Instructions, Manuals, Brochures, and Technical Data.
www.rockwellautomation.com/literature
Product Compatibility and Download Center (PCDC)
Get help determining how products interact, check features and capabilities, and find associated firmware.
www.rockwellautomation.com/global/support/pcdc.page
Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.
Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.
Allen-Bradley, ArmorStratix, LISTEN.THINK.SOLVE, On-Machine, Rockwell Automation, Rockwell Software, and Stratix are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Publication 1783-TD001T-EN-P - July 2018 Supersedes Publication 1783-TD001S-EN-P - May 2018
Copyright © 2018 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.