Page 10
Stratix Ethernet Device Specifications
Stratix 2000 Ethernet Unmanaged Switches - Series A Cat. No.
Total Ports
RJ45 Ports(1)
Combo Ports(1)
SFP Ports(1)
1783-US4T1F/A
5
4 FE, 1 FE multimode preinstalled fiber SFP module
1783-US4T1H/A
5
4 FE, 1 FE singlemode preinstalled fiber SFP module
1783-US5T/A
5
5 FE, - 1783-US5TG/A
5
5 GE, - 1783-US6T2F/A
8
6 FE, 2 FE multimode preinstalled fiber SFP modules
1783-US6T2H/A
8
6 FE, 2 FE singlemode preinstalled fiber SFP modules
1783-US6TG2CG/A
8
6 GE
2 GE(2), 1783-US7T1F/A
8
7 FE, 1 FE multimode preinstalled fiber SFP module
1783-US7T1H/A
8
7 FE, 1 FE singlemode preinstalled fiber SFP module
1783-US8T/A
8
8 FE, - 1783-US14T2S/A
16
14 FE, 2 FE(2)
1783-US16T/A
16
16 FE, - (1) FE = Fast Ethernet; GE = Gigabit Ethernet. (2) SFP modules must be ordered separately.
The following table lists Stratix 2000 series A switches and their series B replacements. For specifications of series B switches, see page 3.
Table 5 - Stratix 2000 Series Change Series A Cat. No.
Series B Replacement Cat. No.
Change(1)
1783-US4T1F/A
1783-US4T1F/B
Same catalog number and configuration
1783-US4T1H/A
1783-US4T1H/B
Same catalog number and configuration
1783-US5T/A
1783-US5T/B
Same catalog number and configuration
1783-US5TG/A
1783-US5TG/B
Same catalog number and configuration
1783-US6T2F/A
1783-US6T2F/B
Same catalog number and configuration
1783-US6T2H/A
1783-US6T2H/B
Same catalog number and configuration
1783-US7T1F/A
1783-US7T1F/B
Same catalog number and configuration
1783-US7T1H/A
1783-US7T1H/B
Same catalog number and configuration
1783-US8T/A
1783-US8T/B
Same catalog number and configuration
1783-US16T/A
1783-US16T/B
Same catalog number and configuration
1783-US14T2S/A
1783-US16T2S/B
1783-US6TG2CG/A
1783-US8TG2GX/B
New catalog number
Replaced 2 GE combo ports with 2 GE copper ports on series B replacement Added 2 GE SFP slots to series B replacement New catalog number
Added 2 FE copper ports to series B replacement
(1) FE = Fast Ethernet; GE = Gigabit Ethernet.
10
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 11
Stratix Ethernet Device Specifications
Table 6 - Technical Specifications - Stratix 2000 Switches, Series A Attribute
1783-US4T1F/A 1783-US4T1H/A
1783-US5TG/A
1783-US6T2F/A 1783-US6T2H/A
1783-US7T1F/A 1783-US7T1H/A
1783-US6TG2CG/A
1783-US14T2S/A
1783-US16T/A
1783-US5T/A
1783-US8T/A
Inrush current, max
0.11 A
0.25 A
0.86 A
1.06 A
0.66 A
4.34 A
4.72 A
0.11 A
1.47 A
Power input
24V (18...60V DC, 18...30V AC 50/60 Hz), Class 2/SELV
Current rating
230.5 mA
432.1 mA
442.3 mA
1242.7 mA
663.2 mA
555.5 mA
250 mA
361 mA
Power dissipation, max
2.841 W
5.491 W
5.927 W
13.643 W
7.991 W
6.72 W
2 W @ 24V AC/DC
4.04 W @ 24V AC/DC
Isolation voltage
30V (continuous), basic insulation type, power to network channels No isolation between individual network channels Type tested at 500V AC for 60 s
RJ45 connector according to IEC 60603-7, 2-pair or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702 rated 82 °C (180 °F) min
RJ45 connector according to IEC 60603-7, 2-pair or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702
0.82…2.5 mm2 (18…14 AWG) twisted-pair copper wire suitable for 82 °C (180 °F) above surrounding ambient temperature outside the enclosure
0.75…2.5 mm2 (18…14 AWG) twisted-pair copper wire suitable for 30 °C (86 °F) above surrounding ambient temperature outside the enclosure
Wire size, ground connection
2.5 mm2 (14 AWG) copper wire suitable for 82 °C (180 °F) above surrounding ambient temperature outside the enclosure, with a suitable ring terminal
2.5 mm2 (14 AWG) copper wire suitable for 30 °C (86 °F) above surrounding ambient temperature outside the enclosure, with a suitable ring terminal
Screw torque, ground terminal, max
1.82 N•m (16 in•lb)
Screw torque, power terminals
0.4…0.5 N•m (3.5…4.4 in•lb)
Wiring category(2)
1 - on power ports 2 - on communication ports
Enclosure type rating
None (open-style)
North American temp code
T4
T5
IEC temp code
T4
T5
MAC addresses, max supported
1K
Wire size, Ethernet connection(1)
Wire size, DC power connection
SFP modules(3)
1K
Preinstalled
No SFP slots
8K
8K
8K
8K
1K
8K
Preinstalled
Ordered separately: 1783-SFP1GSX 1783-SFP1GLX 1783-SFP1GEXE 1783-SFP1GZX
Ordered separately: 1783-SFP100FX 1783-SFP100LX 1783-SFP100EXC 1783-SFP100ZXC
No SFP slots
No SFP slots
No SFP slots
Preinstalled
(1) See page 71 for recommended products. (2) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. (3) For specifications of preinstalled SFP modules, see Table 7. For specifications of SFP modules ordered separately, see Table 54.
Table 7 - Preinstalled SFP Module Specifications - Stratix 2000 Switches Attribute
Multimode (100Base-FX)
Singlemode (100Base-LX)
Central wavelength (nm)
1310
1310
Transmission distance (km)
2
20
Applicable distance (km)
0…2
0…20
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
11
Page 12
Stratix Ethernet Device Specifications
Table 7 - Preinstalled SFP Module Specifications - Stratix 2000 Switches Attribute
Multimode (100Base-FX)
Singlemode (100Base-LX)
Luminous power, min (db)
-19
-10
Luminous power, max (db)
-10
-5
Receiving sensitivity (dBm)
-31
-34
Overload luminous power
-3
-3
Table 8 - Environmental Specifications - Stratix 2000 Switches, Series A Attribute
1783-US4T1F/A, 1783-US4T1H/A, 1784-US5TG/A, 1783-US6T2F/A, 1783-US6T2H/A, 1783-US6TG2CG/A, 1783-US7T1F/A, 1783-US7T1H/A, 1783-US14T2S/A, 1783-US16T/A
1783-US5T/A
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
-40…+70 °C (-40…+158 °F)
0…+60 °C (32…+140 °F)
Temperature, surrounding air, max
70 °C (158 °F)
60 °C (140 °F)
1783-US8T/A
Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold) -40…+85 °C (-40…+185 °F) IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat) IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
5…95% noncondensing
Vibration IEC 60068-2-6 (Test Fc, Operating)
2 g @ 10…150 Hz
Operating shock IEC 60068-2-27 (Test Ea, Unpackaged Shock)
15 g
Nonoperating shock IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30 g
Emissions CISPR11 (IEC 61000-6-4)
Class A
ESD immunity IEC 61000-4-2
8 kV contact discharges 15 kV air discharges
Radiated RF immunity IEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
EFT/B immunity IEC 61000-4-4
±4 kV at 5 kHz on power ports ±3 kV at 5 kHz on communication ports
Surge transient immunity IEC 61000-4-5
±2 kV line-line (DM) and ±4 kV line-earth (CM) on DC power ports ±2 kV line-earth (CM) on communication port
Conducted RF immunity IEC 61000-4-6
10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Magnetic field immunity IEC 61000-4-8
30 A/m long duration and 300 A/m short duration at 50 Hz
Magnetic pulse immunity IEC 61000-4-9, Environmental rating
IP20
12
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
2 g @ 10…500 Hz
6 kV contact discharges 8 kV air discharges
30 A/m pulse
Page 13
Stratix Ethernet Device Specifications
Table 9 - Certifications- Stratix 2000 Switches, Series A Certifications (when product is marked)(1)
1783-US4T1F/A, 1783-US4T1H/A, 1784-US5TG/A, 1783-US6T2F/A, 1783-US6T2H/A, 1783-US6TG2CG/A, 1783-US7T1F/A, 1783-US7T1H/A, 1783-US14T2S/A, 1783-US16T/A
1783-US5T/A, 1783-US8T/A c-UL-us
UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810.
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810.
CE
European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2011/65/EU RoHS, compliant with: EN 50581; Technical Documentation
RCM
Australian Radiocommunications Act, compliant with: EN 61000-6.4; Industrial Emissions
Ex
European Union 94/9/EC ATEX Directive, compliant with: EN 60079-15; Potentially Explosive Atmospheres, Protection “n” EN 60079-0; General Requirements II 3 G Ex nA IIC T4 Gc X
KC
Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3
European Union 94/9/EC ATEX Directive, compliant with: EN 60079-15; Potentially Explosive Atmospheres, Protection “n” EN 60079-0; General Requirements II 3 G Ex nA IIC T5 Gc
(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
13
Page 14
Stratix Ethernet Device Specifications
Dimensions - Stratix 2000 Switches, Series A 1783-US4T1F/A, 1783-US4T1H/A,1783-US5TG/A Switch Dimensions
30 mm (1.18 in.)
100.84 mm (3.97 in.) 91.5 mm (3.60 in.)
30 mm (1.18 in.)
6 mm (0.24 in.)
115 mm (4.53 in.)
35 mm (1.38 in.)
1783-US5T/A Switch Dimensions 100.8 100.8mm mm (3.97 (3.97 in.)in.) 91.5 mm (3.6 in.)
30 mm (1.18 in.)
6 mm (0.24 in.)
115 mm (4.53 in.)
14
35 mm (1.38 in.)
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
Page 15
Stratix Ethernet Device Specifications
1783-US6T2F/A, 1783-US6T2H/A, 1783-US7T1F/A, 1783-US7T1H/A Switch Dimensions 115.82 mm (4.56 in.) 106.5 mm (4.19 in.)
53.6 mm (2.11 in.)
53.6 mm (2.11 in.)
6 mm (0.24 in.)
35 mm (1.38 in.)
135 mm (5.31 in.)
1783-US8T/A Switch Dimensions 53.6 mm (2.11 in.)
53.6 mm (2.11 in.)
106.5 mm (4.19 in.)
PWR
6 mm (0.24 in.)
35 mm (1.38 in.)
8
5
6
3
4
1
2
135 mm (5.31 in.)
1783-US8T
7
32312-M
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
15
Page 16
Stratix Ethernet Device Specifications
1783-US16T/A, 1783-US14T2S/A, 1783-US6TG2CG/A Switch Dimensions 88 mm (3.46 in.)
146.30 mm (5.76 in.)
88 mm (3.46 in.)
137 mm (5.39 in.)
6 mm (0.24 in.) 135 mm (5.31 in.)
16
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
35 mm (1.38 in.)
Page 17
Stratix Ethernet Device Specifications
Stratix 2500 Ethernet Lightly Managed Switches Cat. No.
Description
Total Ports
1783-LMS5
5 ports copper 10/100
5
1783-LMS8
8 ports copper 10/100
8
Table 10 - Technical Specifications - Stratix 2500 Switches Attribute
1783-LMS5
1783-LMS8
Power input
12…24V DC, 0.3…0.2 A(SELV)
12…24V DC, 0.4…0.2 A (SELV)
Power consumption
4.2 W
5.3 W
Power dissipation
4.2 W
5.3 W
Wire size, Ethernet connection(1)
RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702
Wire size, DC power connection
1.3…0.82 mm2 (16…18 AWG) solid or stranded copper wire rated at 30 °C (86 °F), or greater, above the surrounding air temperature
Wire size, ground connection
5.2...3.3 mm2 (10...12 AWG) solid or stranded copper wire
Torque, power terminal screw
0.19 N•m (1.7 in•lb)
Torque, functional ground lug screw
0.51 N•m (4.5 in•lb)
Wiring category(2)(3)
2 - on power ports 2 - on communication ports
Enclosure type rating
None (open-style)
North American temp code
T4
ATEX temp code
T4
(1) See page 71 for recommended products. (2) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.. (3) Use this Conductor Category information for planning conductor routing as described in the Stratux 2500 Managed Switches Installation Instructions, publication 1783-IN011.
Table 11 - Environmental Specifications - Stratix 2500 Switches Attribute
1783-LMS5, 1783-LMS8
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
-20 °C < Ta < +60 °C (-4 °F < Ta < +140 °F)
Temperature, ambient, max
60 °C (140 °F)
Temperature, surrounding air, max
60 °C (140 °F)
Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
-40…+85 °C (-40…+185 °F)
Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
5…95% noncondensing
Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30 g
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018
17
Page 18
Stratix Ethernet Device Specifications
Table 11 - Environmental Specifications - Stratix 2500 Switches (continued) Attribute
1783-LMS5, 1783-LMS8
Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30 g
Emissions CISPR11 (IEC 61000-6-4)
IEC 61000-6-4
ESD immunity IEC 61000-4-2
6 kV contact discharges 8 kV air discharges
Radiated RF immunity IEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
EFT/B immunity IEC 61000-4-4
±3 kV at 5 @ 100 kHz on DC power ports ±3 kV at 5 @ 100 kHz on Ethernet ports
Surge transient immunity IEC 61000-4-5
±1 kV line-line(DM) and ±2 kV line-earth(CM) on DC power ports ±2 kV line-earth(CM) on communication ports
Conducted RF immunity IEC 61000-4-6
10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Environmental rating
IP30
Table 12 - Certifications - Stratix 2500 Switches Certifications (when product is marked)(1)
1783-LMS5, 1783-LMS8 c-UL-us
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. UL Listed for Class I, Zone 2 Hazardous Locations, certified for U.S. and Canada. See UL File E194810. • Ex nA IIC T4 Gc X • AEx nA IIC T4 Gc
CE
European Union 2014/30/EU EMC Directive, compliant with: • EN 61326-1; Meas./Control/Lab., Industrial Requirements • EN 61000-6-2; Industrial Immunity • EN 61000-6-4; Industrial Emissions • EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2011/65/EU RoHS, compliant with: • EN 50581; Technical documentation
RCM
Australian Radiocommunications Act, compliant with: • AS/NZS CISPR 11; Industrial Emissions
Ex
European Union 2014/34/EU ATEX Directive, compliant with: • EN 60079-0; General Requirements • EN 60079-15; Potentially Explosive Atmospheres, Protection "n" • II 3 G Ex nA IIC T4 Gc • DEMKO 16 ATEX 1731
EAC
Russian Customs Union TR CU 020/2011 EMC Technical Regulation
EtherNet/IP
ODVA conformance tested to EtherNet/IP specifications
(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
18
Rockwell Automation Publication 1783-TD001T-EN-P - July 2018