Page 371

Index Numerics 1/2slot addressing 4-3, E-4, E-5 1770KF2 9-2 1771AF 6-6 1771ALX 8-1, E-5, F-9 1771AS 6-6 1771ASB 6-6, 6-11, E-5, F-6 1771CD 9-2 1771DCM 6-6 1771KRF 9-2 1771SN 6-6 1772SD, SD2 6-6 1775S4A, S4B 6-6 1775SR 6-6 1784CAK G-5 1784CP 9-2, G-6 1784CP10 G-2, G-5, G-7 1784CP11 G-2, G-5, G-8 1784CP2 9-2 1784CP3 9-2 1784CP5 9-2, G-5, G-6 1784CP6 9-2, G-5, G-6 1784CP7 G-5, G-6 1784CP8 G-5, G-7 1784KL 9-2, G-5, G-6, G-7 1784KT 9-2, G-5, G-6, G-7 1784KT2 9-2, G-5, G-6, G-7 1784KTK1 G-5 1784PCM5 9-2, G-5, G-6, G-8 1784PCMK 9-2, G-5, G-8 1785KA 9-2 1785KA5 9-2 1785KE 9-2, G-5 1785-RC Relay Cartridge 1-1 1slot addressing 4-3, E-4, E-5 2slot addressing 4-3, E-4, E-5 6008SQH1, SQH2 6-6

A active buffers 6-14 adapter mode adapter channel status 7-17, 7-19 blocktransfer programming example

7-14 channel configuration 7-2 communicating with 7-1 configuring channels 7-3 defined 1-12 discrete transfer configuration file 7-2,

7-9 effects of blocktransfer on discrete data

7-15 programming block transfers 7-10 supervisory processor status 7-18 transferring data 7-10 addressing 32point example 4-5 8 and 16point example 4-4 assigning DH+ node address 9-4 rack numbers 4-8 blocktransfer modules 4-7 choosing a mode 4-3 concept 4-1 data files 4-16 Ethernet 11-2 Ethernet broadcast 11-9 extendedlocal I/O 8-2 I/O image 4-16 I/O status file 6-24 indexed 4-20 indirect 4-18 logical 4-17 mnemonics 4-18 racks 8-10 relating a bit to an input/output device

4-2 remote I/O racks 4-9 selecting mode E-4, E-5 stations in poll file 10-17 summary 4-7 symbolic 4-21 terms 4-1 ASCII configuring serial port 10-18 instructions D-27 status 10-24 automatic configuration 6-9, 6-10, 8-9,

8-11

B backpanel spacing 3-5 backplane switch settings E-4, E-5 Belden 9463 6-3 bit data storage 4-11 bit modify instructions D-16

Publication 1785-UM012D-EN-P - July 2005

Page 372

2

Index blocktransfer 2-3, 4-7, 5-3, 5-4, 6-13,

6-14, 6-15, 6-16, 6-17, 6-19, 6-20, 7-7, 7-10, 7-11, 7-14, 8-6, 8-7, 15-11, 17-2, 18-3, C-8, C-12, D-25

BOOTP disabling 11-4 example 11-8 hardware address 11-8 IP address 11-7 using 11-5 broadcast addressing 11-9

C cables Belden 9463 6-3 communication interfaces G-5 DH+ link 9-2 Ethernet 11-1, G-9 extendedlocal I/O 8-2 pin assignments G-2 programming 9-2 raceway layout 3-4 reference G-1 remote I/O 6-5 routing conductors 3-4 serial 10-5 calculating processor scan time C-11, C-12 remote I/O scan time C-9 throughput C-5 timing C-5 changing modes 1-9 channel adapter configuration 7-2 configuring remote I/O adapter 7-3 remote I/O scanner 6-6 DH+ configuration 9-3, 9-4 Ethernet using 6200 software 11-3 using BOOTP 11-5 extendedlocal I/O 8-9 extendedlocal I/O scanner configuration

8-9 monitoring DH+ link 9-12 extendedlocal I/O 8-12 remote I/O adapter 7-19 remote I/O scanner 6-21 privilege class 12-4 remote I/O scanner configuration 6-7 Publication 1785-UM012D-EN-P - July 2005 serial 10-6 troubleshooting F-4 channel status DH+ 9-12 Ethernet 11-35 extendedlocal I/O 8-12 remote I/O adapter 7-19 remote I/O scanner 6-21 serial 10-22 chassis configuration plug E-6 dimensions 3-1 setting switches E-4, E-5 spacing 3-1 classes privileges 12-3 communicating 1771ASB 6-11 DH+ link 9-1 Ethernet 11-1 extendedlocal I/O 8-1 pointtopoint 10-3 serial devices 10-1 with adapter channel 7-1 communication configuring serial mode change 10-21 rate C-7 compare instructions D-5 complementary I/O 4-24 completed program state 13-12 components front panel 1-2 spacing 3-1 compute instructions D-7 conductors 3-4 configuring ASCII (user mode) 10-18 blocktransfer requests in an adapter channel 7-11 chassis extendedlocal I/O E-10 power supply E-6 communication mode change 10-21 DF1 master 10-12 DF1 slave 10-9 DH+ channel 9-3 discrete transfer configuration files 7-5 Ethernet using 6200 software 11-3 using BOOTP 11-5 extendedlocal I/O scanner channel 8-9 fault routine 15-4

Page 373

Index

I/O status file 6-7 main control programs 16-4 PII 18-5 pointtopoint 10-6 processorresident rack 5-4 remote I/O adapter channel 7-2, 7-3 remote I/O scanner channel 6-6 serial port 10-2, 10-6 startup procedure 14-3 STI 17-3 connections Ethernet G-9 control bits 14-3 controller documentation A-1 controller specifications A-1 controlling outputs 15-3 conversion instructions D-15 cooling 3-1 counter instructions D-4

D daisy chain 6-5, 9-2 data block 4-11 data file addressing 4-13 range of values 4-15 read/write privileges 12-5 types of addressing 4-16 unused 4-12 data storage bit 4-11 concepts 4-10 data block 4-11 files 4-11 member 4-11 structure 4-11 type 4-11 userdefined 4-11 words 4-11 data table file defaults 4-13 memory per file 4-12 data transfer 6-11 blocktransfer 8-6 effects of blocktransfer on discrete data

7-15 extendedlocal I/O 8-4 I/O backplane transfer time C-6 I/O transfer time C-6

3 system design C-10 types 1-12 data type valid values 4-15 delay due to online editing C-4 density I/O modules 2-2 design tip addressing and placing extendedlocal I/O

8-2 addressing extendedlocal I/O racks 8-3 assigning privileges 12-3 assigning racks 4-8 assigning remote I/O rack numbers 4-9 blocktransfer programming 6-19 DH+ link design 9-17 editing the scan list for multiple rackupdates 6-10 extendedlocal I/O link design 8-2 global status flag file 9-6 group data 4-12 guidelines for PIIs 18-4 guidelines for writing STI programs 17-1 optimizing instruction execution time

4-22 optimizing processor memory 4-22 organizing files 4-12 placing blocktransfer modules 5-3 placing extendedlocal I/O modules 8-4 program design tips C-13 programming considerations for extendedlocal I/O 8-8 remote I/O cable design 6-5 remote I/O link 6-4 RS232, 422A, and 423 cable lengths

10-5 split global status flags files across channels C-5 using blocktransfers in STIs 17-2 writing PII programs 18-2 devices DH+ link 9-2 extendedlocal I/O 8-1 maximum 6-4 remote I/O 6-2 serial 10-1 DF1 master communication 10-3 configuring 10-12 polling scheme 10-16

Publication 1785-UM012D-EN-P - July 2005

Page 374

4

Index

DH+ link cable lengths 9-2 communicating with devices 9-1 configuring channels 9-3 default address 9-3 defining the processor address 9-4 design tip 9-17 diagnostic counters 9-12 estimating performance 9-12 global status flag file 9-5 internal processing time 9-15 message destination 9-14 monitoring status 9-12 nodes/timing 9-13 planning cabling 9-2 response time test results 9-16 size and number of messages 9-13 terminating 9-3 token passing 9-13 transmission rate 9-4 troubleshooting F-4 diagnostic counters DH+ 9-12 remote I/O 6-21 diagnostic instructions D-19 dimensions chassis 3-1 power supplies 3-6 discrete data transfer between scanner and remote I/O adapter

7-7 extendedlocal I/O 8-5 discretetransfer configuration files 7-2,

7-5 discretetransfer data 5-3, 7-10, 7-17,

7-18

DNS 11-15 Domain Name Service 11-15

E element 4-11 Embedded Web Server 11-16 environment proper 3-1 error codes 11-33 Ethernet messaging 11-33 ESD protection 3-3

Publication 1785-UM012D-EN-P - July 2005

Ethernet addressing 11-2 advanced functions 11-9 broadcast addressing 11-9 cables G-9 communication 11-1 configuring using 6200 software 11-3 using BOOTP 11-5 error codes 11-33 gateways 11-11 messaging 11-37 network requirements 11-1 processor performance 11-37 status data 11-35 subnet masks 11-11 transceivers G-9 transmit indicator F-6 troubleshooting F-5 eventdriven interrupts 13-10 example 32point addressing 4-5 8 and 16point addressing 4-4 adaptermode blocktransfer 7-14 blocktransfer timing in extendedlocal I/O

8-8

BOOTP 11-8 calculating processor time C-12 efficiently using image table space 4-6 PII application 18-2 STI application 17-2 executing program state 13-12 extendedlocal I/O grounding configuration 3-7 extendedlocal I/O 1-14, 6-13, 8-1, 8-2,

8-4, 8-7, 8-8, 8-9, 8-10, 8-12, 15-3, E-5, E-9, E-10, F-5, F-9

F fault routines blocktransfer data 15-11 change from ladder logic 15-9 configuring 15-4 controlling outputs 15-3 enabling 15-4 how to program 15-6 powerup protection 14-1 preparing 15-1 program flow 13-10 programming feature 13-10 recover rack fault via ladder logic 15-10

Page 375

Index startup 14-2 testing 15-11 using 15-1 watchdog timer 15-5 when to use 13-11 faulted program state 13-12 faults blocktransfer, minor 6-15 clearing 15-7, 15-12 detecting major 15-2 extendedlocal I/O rack 15-3 major 15-1, 15-12 major and minor 15-11 minor 15-12 monitoring 15-12 processorresident local I/O rack 15-3 remote I/O chassis 15-3 remote I/O rack 15-4 status information 15-11 file instructions D-17 files 4-15 data storage 4-11 read/write privileges 12-5 floating point valid value range 4-15 forcing inputs and outputs 13-1 SFC transitions 13-2 front panel PLC5/11,5/20 1-3 PLC5/20E 1-6 PLC5/30 1-4 PLC5/40, 5/60, and 5/80 1-5 PLC5/40E and 5/80E 1-7 PLC5/40L, 5/60L 1-8

G gapping 4-12 gateways 11-11 General Ethernet Counters 11-19 generating web user provided pages

11-22 global inhibit bits clearing 6-10, 8-11 global status bits 15-11, 15-13 racks 07 B-3 racks 1017 B-10 global status flags file C-5 grounding extendedlocal I/O system 3-7

5 processorresident chassis 3-7 remote I/O system 3-7 groups definition 4-1 guidelines addressing 4-6, 4-7 cable routing 3-4 I/O point size (density) selection 2-2 I/O selection 2-1 PII programming considerations 18-4 placing extendedlocal I/O modules 8-4 placing I/O modules 2-3 proper environment 3-1 selecting interrupt routines 13-11 STI programming considerations 17-1 when to use interrupt routines 13-11

H hardware fault 15-2 housekeeping effects of C-4 HTML pages 11-22

I I/O addressing 4-1 I/O modules cable categories 3-4 placing 2-3 select point size (density) 2-2 selection guidelines 2-1 I/O scan disabling 16-2 I/O status file addressing 6-24 bit layout 6-24, 6-26 configuring 6-7 I/O update configuring 16-4 ignoring empty slots C-6 image table address 4-16 input and output 4-1 immediate I/O programming with blocktransfers 6-21 timing 5-3 using with adjacent blocktransfer modules 5-4 indexed address 4-20

Publication 1785-UM012D-EN-P - July 2005

Page 376

6

Index indicators 1771ALX F-9 1771ASB F-6 communication F-4 Ethernet F-5, F-6 extendedlocal I/O F-5 PLC5/11,5/20 1-3 PLC5/20E 1-6 PLC5/30 1-4 PLC5/40, 5/60, and 5/80 1-5 PLC5/40E and 5/80E 1-7 PLC5/40L, 5/60L 1-8 processor F-2 indirect address 4-18 instructions ASCII D-27 bit modify D-16 blocktransfer D-25 compare D-5 compute D-7 conversion D-15 counter D-4 diagnostic D-19 file D-17 logical D-14 memory bit and word instructions D-30 file, program control, and ASCII

D-38 message D-25 move D-16 PID D-25 prescan timing F-10 program control D-22 quick reference D-1 relay D-2 sequencer D-21 shift register D-20 timer D-3 timing bit and word instructions D-30 file, program control, and ASCII

D-38 interrupt routines 13-10 interrupts C-3 scheduling 13-11 introduction processor scanning 5-1 remote I/O 6-3

Publication 1785-UM012D-EN-P - July 2005

K keyswitch operation 1-9 PLC5/11, 5/20 1-3 PLC5/20E 1-6 PLC5/30 1-4 PLC5/40, 5/60, and 5/80 1-5 PLC5/40E and 5/80E 1-7 PLC5/40L, 5/60L 1-8

L ladder logic 1-10 last state 15-2, E-4, E-5 logic scan 5-2 time C-2 logical address mnemonic 4-18 specifying 4-17 logical instructions D-14

M main control program 16-4 main control programs 1-10, 16-1 major faults clearing 15-7, 15-12 defined 15-2 responses 15-1 master communication 10-12 DF1 master mode 10-3 messagebased mode, defined 10-4 pointtopoint 10-6 standard mode 10-4 master station polling 10-4 maximizing system performance 16-2 MCPs 1-10 configuring 16-4 monitoring 16-5 scan time 16-5 scheduling 13-11, 16-2 specify order 16-4 temporarily disable 16-4 using 16-1 media Ethernet 11-1 member data storage 4-11 memory bit and word instructions D-30 data storage 4-10 data table file sizes 4-13

Page 377

Index file, program control, and ASCII instructions D-38 gapping 4-12 optimizing 4-22 program files 4-15 protection E-4 memory card diagnostics B-12 memory module transfer E-4 message instruction D-25 messagebased communication 10-4 messages DH+ link 9-13 editing online C-12 Ethernet error codes 11-33 minor faults 15-12 mnemonic addressing 4-18 modes adapter 1-12 addressing 4-3 extendedlocal 1-14 keyswitch 1-9 scanner 1-11 monitoring adapter channel status 7-17 DH+ channel status 9-12 Ethernet channel status 11-35 extendedlocal I/O 8-12 faults 15-11 PII 18-6 remote I/O adapter channel status 7-19 remote I/O scanner channel status 6-21 serial port channel status 10-22 STI status 17-4 supervisory processor status 7-18 mounting I/O chassis dimensions 3-5 power supply dimensions 3-6 move instructions D-16 multihop examples 11-30 multihop messaging 11-29 multiple chassis status bits 15-11, 15-13

N noise protection 3-4 non-multihop messaging 11-32

7

O offline file privileges 12-4 online editing housekeeping C-4 messages and blocktransfers C-12 PIIs 18-4 STIs 17-2 operating temperature 3-1 optimizing processor memory and instruction execution 4-22 system C-5 outputs, controlling after a fault 15-3

P passwords 12-2 performance DH+ link 9-12 Ethernet processor 11-37 housekeeping C-4 impact of online editing C-12 maximizing 16-2 maximizing your system C-1 optimizing instruction execution time

4-22 optimizing processor memory 4-22 PII 18-4 STI 17-2

PID D-25 PII C-3, C-4 configuring 18-5 example application ladder logic 18-2 monitoring 18-6 performance 18-4 program flow 13-10 programming considerations 18-4 status 18-6 to extendedlocal I/O chassis 8-4 using 18-1 when to use 13-11 with a blocktransfer instruction 18-3 writing ladder logic 18-2 placing backpanels 3-5 extendedlocal I/O 8-2 extendedlocal I/O modules 8-4 I/O modules 2-3 points definition 4-1 pointtopoint communication 10-3

Publication 1785-UM012D-EN-P - July 2005

Page 378

8

Index polling schemes 10-16 techniques 10-4 power supplies mounting dimensions 3-6 powerup routines 13-10, 13-11, 14-1,

14-3 priority scheduling 13-11 privilege class assigned to channel 12-4 assigned to node 12-4 assigned to offline file 12-4 privileges assigning class to channels 12-4 assigning class to offline files 12-4 assigning to data files 12-5 assigning to program files 12-5 defining classes 12-3 guidelines for assigning 12-3 types of 12-2 process control instructions D-25 Processor specifications A-1 processor input interrupt 8-4, 18-1 processor status file layout B-1 processor time data exchange C-11 example C-12 processorresident I/O 6-20, 13-2, 15-3 Program (PROG) mode 1-9 program constant valid value range 4-15 program control instructions D-22 program execution 1-9, 13-12 program file memory 4-15 read/write privileges 12-5 storage 4-15 program scan activities that can affect the time C-1 effect of housekeeping C-4 false versus true logic C-2 input states C-2 instructions C-3 introduction 5-2 MCP 16-5 using interrupts C-3 program states 13-12 programming blocktransfers to an adapter channel

7-10

Publication 1785-UM012D-EN-P - July 2005 considerations 13-1 design tips for better performance C-13 effects of blocktransfers on discrete data

7-15 extendedlocal I/O 8-8 fault routines 15-6 features 1-10 handling faults in remote I/O chassis

15-4 multiple blocktransfers in an adapter channel 7-13 protecting 12-1 recover from rack fault 15-10 terminal connections G-5 protecting programs 12-1

R raceway layout 3-4 rack addressing limits A-2 rack control bits racks 07 B-10 racks 1017 B-10 rack entries, how they affect scan time

C-7 rack size extendedlocal I/O scanner 8-9 remote I/O scanner 6-9 racks addressing 8-10 definition 4-1 extendedlocal I/O 8-3 processorresident local I/O 4-8 relationship to chassis size and addressing mode 4-8 remote I/O 4-9 read/write privileges assigned to data file 12-5 assigned to program file 12-5 ready program state 13-12 relative humidity 3-1 relay cartridge 1-1 relay instructions D-2 Remote (REM) mode 1-9 remote I/O adapter mode 7-2 adaptermode status 7-19 blocktransfers 6-13, 6-15 cable lengths 6-5 calculating scan time C-9 chassis backplane switch setting E-5

Page 379

Index communication rate C-7 configuration overview 6-1 configuration steps 6-12 data transfer 6-11 design C-10, C-11 faults 15-3 how blocktransfers affect scan time C-8 I/O status file 6-7 introduction 6-3 maximum devices 6-4 number of rack entries in scan list C-7 optimizing scan time C-9 possible devices 6-2 programming blocktransfers 7-10 rack fault 15-4 scan list 6-3, 6-9 scan time C-6 scanner channel configuration 6-6 status 6-21 switch settings E-7 system setup 6-4 terminating the link 6-5 troubleshooting F-4, F-6 remote I/O adapter defined 1-12 remote I/O scanner defined 1-11 remote I/O system grounding configuration 3-7 remote mode change 10-5 Run (RUN) mode 1-9

S SCADA 10-1 scan list 6-3 contents 6-9 creating 6-9 extendedlocal I/O 8-9 how entries affect scan time C-7 limitations 6-10, 8-11 modifying 6-10 scan time calculating C-5 scanner configuring channels 6-7 creating a scan list 8-9, 8-12 modifying a scan list 8-11 scanner mode block transfer in a PII 18-3

9 blocktransfer 6-15 blocktransfer in an STI 17-2 channel configuration 6-6 communicating with 1771ASB 6-11 configuring extendedlocal I/O channels

8-9 creating a scan list 6-9, 8-11 data transfer 6-11 defined 1-11 introduction 5-3 monitoring status 6-21 scanning blocktransfer data 6-13 introduction to 5-1 scheduling 13-11 selectable timed interrupt 17-1 sequencer instructions D-21 sequential function charts 1-10 serial ASCII (user mode) 10-18 cables G-2 changing modes 10-5 choosing the digital interface 10-1 communication mode change 10-21 configuring 10-6 DF1 master 10-3, 10-12 DF1 master status 10-23 DF1 pointtopoint 10-3 DF1 slave 10-3, 10-9 DF1 slave status 10-22 pin assignments G-1 planning cabling 10-5 pointtopoint 10-6 pointtopoint status 10-22 protocols 10-6 setting switches (SW2) 10-2 status 10-22 system mode 10-2 user mode 10-2 user mode (ASCII) status 10-24 using channel 0 10-2 serial devices 10-1 setting switches chassis backplane E-4, E-5 extendedlocal I/O E-9 last state 15-2 remote I/O without complementary I/O E-7 SW1 E-2 SW2 E-3

Publication 1785-UM012D-EN-P - July 2005

Page 380

10

Index

SFC transitions forcing 13-2 SFCs 1-10 shift register instructions D-20 site preparation conductor categories 3-4 raceway layout 3-4 routing conductors 3-4 slave communication 10-3, 10-9 spacing chassis 3-1 Specification battery A-2 Specifications A-1 specifications A-1 standard communication 10-4 startup 14-2 status adaptermode channel 7-17 remote I/O 6-21 supervisory processor 7-18 status bits monitoring 15-13 status file processor B-1 size 4-13 status information main control program scan 16-5 PIIs 18-6 STIs 17-4 STI 15-11, C-3, C-4 application example ladder logic 17-2 configuring 17-3 performance 17-2 program flow 13-10 program scan 17-4 status 17-4 using 17-1 when to use 13-11 with a blocktransfer instruction 17-2 writing ladder logic 17-1 storage program files 4-15 temperature 3-1 structure data storage 4-11 structured text 1-10 subnet masks 11-11 subroutines 1-10 switch assemblies chassis E-4, E-5 chassis configuration plug E-6 extendedlocal I/O E-9 Publication 1785-UM012D-EN-P - July 2005 remote I/O without complementary I/O E-7 SW1 E-2 SW2 E-3 switch assembly SW1 defining the default DH+ address 9-3 switch setting reference E-1 symbol address 4-21 system design C-10, C-11 performance 16-2, C-1 system layout backpanel spacing 3-5 environment 3-1 system mode 10-2 DF1 master 10-3 DF1 slave 10-3 pointtopoint 10-3 status 10-22 system specifications A-1

T TCP/IP 11-32 TCP/IP configuration 11-16 terminating DH+ link 9-3 extendedlocal I/O link 8-2 remote I/O link 6-5 termination resistors 6-5, 9-3 testing fault routines 15-11 throughput calculating C-5 I/O backplane transfer time C-6 I/O transfer time C-6 processor scan time C-11 remote I/O scan time C-6 timedriven interrupts 13-10 timer instructions D-3 timing bit and word instructions D-30 blocktransfer data 6-13, 8-6 calculating blocktransfer completion time

8-7, C-8 calculating throughput C-5 communication rate C-7 example C-12 false vs. true logic C-2

Page 381

Index file, program control, and ASCII instructions D-38 global status flags file C-5 housekeeping C-4 input states C-2 instructions C-3 internal processing 9-15 nodes 9-13 optimizing for remote I/O C-9 prescan F-10 program scan 5-2, 5-3 to extendedlocal I/O 8-5 using interrupts C-3 token passing 9-13 transceivers G-9 troubleshooting communications F-4 Ethernet F-5 extendedlocal I/O F-5, F-9 processor F-2 remote I/O F-6 trunk line/drop line 6-5, 9-2 type data storage 4-11

11

U UID/UIE influencing processor priorities 13-14 STI 15-11, 17-3 understanding processor memory 4-10 user control bits processor status file B-10 startup procedure 14-3 user interrupts 13-14 user mode 10-2, 10-18

W waiting program state 13-12 waiting queues 6-14 watchdog timer 15-5 Web Server 11-16 words data storage 4-11

Publication 1785-UM012D-EN-P - July 2005

Page 382

12

Index

Publication 1785-UM012D-EN-P - July 2005