Enhanced and Ethernet PLC-5 Programmable Controllers User Manual: Appendix G - Cable Reference

Pages 361 to 370 of 388, from Enhanced and Ethernet PLC-5 Programmable Controllers User Manual

The original document is the PDF (5.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 1785-L20B and Allen-Bradley 1785-L40B

Page 361

Appendix

G

Cable Reference

Using This Chapter

Channel 0 Pin Assignments Pin

For Information About

Go to Page

Channel 0 pin assignments

G-1

Serial cable pin assignments

G-2

Connecting diagrams

G-3

Programming cable specification

G-5

Ethernet cable connections

G-9

The side label of the controller shows a table listing channel 0 (RS-port) pin assignments. This table shows the same information:

RS-232C

RS-422A

RS-423

1

C.GND

C.GND

C.GND

14

2

TXD.OUT

TXD.OUT+

TXD.OUT

15

3

RXD.IN

RXD.IN+

RXD.IN

16

4

RTS.OUT

RTS.OUT+

RTS.OUT

17

5

CTS.IN

CTS.IN+

CTS.IN

18

6

DSR.IN

DSR.IN+

DSR.IN

7

SIG.GND

SIG.GND

8

DCD.IN

DCD.IN+

NOT USED

DCD.IN-

NOT USED

RXD.IN-

REC COM

19

NOT USED

RTS.OUT-

NOT USED

SIG.GND

20

DTR.OUT

DTR.OUT+

DTR.OUT

DCD.IN

21 22

NOT USED

DSR.IN-

NOT USED

23

NOT USED

DTR.OUT-

NOT USED

NOT USED

12

25 CTS.IN-

RS-423 SEND COM

24

NOT USED

RS-422A TXD.OUT-

11

13

RS-232C NOT USED

9 10

Pin

NOT USED

The shading indicates that the pin is reserved.

1

Publication 1785-UM012D-EN-P - July 2005

Page 362

G-2

Cable Reference

The following diagrams show the pin assignments for the cables you need for serial port communications.

Serial Cable Pin Assignments Cable #1

Cable #2

Cable #3

9-pin D-Shell

25-pin D-Shell

25-pin D-Shell

25-pin D-Shell

9-pin D-Shell

25-pin D-Shell

Workstation (female) RXD 2 GND 5

1770-KF2 (female) 2 7

Workstation (female) TXD 2 GND 7

1770-KF2 (female) 3 7

Workstation (female) TXD 2 GND 7

1770-KF2 (female) 3 7

TXD 3

3

RXD 3

2

RXD 3

2

DCD 1 DTR 4 DSR 6

4 RTS 5 CTS

RTS 4 CTS 5

4 RTS 5 CTS

RTS 4 CTS 5

4 RTS 5 CTS

RTS 7 CTS 8

6 DSR 8 DCD 20 DTR

DSR 6 DCD 8 DTR 20

6 DSR 8 DCD 20 DTR

DSR 6 DCD 8 DTR 9

6 DSR 8 DCD 20 DTR

11955-I

11957-I

Cable #5

Cable #4 9-pin D-Shell Workstation female) DCD 1 RXD 2 TXD 3 DTR 4 GND 5 DSR 6 RTS 7 CTS 8 RNG 9 CASE

11958-I

25-pin D-Shell Modem (Male) 8 3 2 20 7 6 4 5 22 1 11959-I

Publication 1785-UM012D-EN-P - July 2005

Cable #6

9-pin D-Shell Workstation (female)

25-pin D-Shell Modem (Male)

25-pin D-Shell Workstation (female)

25-pin D-Shel Modem (Male)

RNG 1 TXD 2 RXD 3 RTS 4 CTS 5 DSR 6 GND 7 DCD 8 DTR 9

22 2 3 4 5 6 7 8 20

CHS 1 TXD 2 RXD 3 RTS 4 CTS 5 DSR 6 GND 7 DCD 8 DTR 20

1 2 3 4 5 6 7 8 20

11960-I

11961-I

Page 363

Cable Reference

G-3

Connecting Diagrams 1784-CP5 with -CP7 adapter cable #1

Terminal

1770-KF2

PLC-5 controller

9-Pin Serial Port Workstation Terminal

1784-CAK

1785-KE Series B

1770-CD

PLC-5

Note: 1785-KE Series A uses 1785-CP5 cable and 1785-CP7 adapter with the Enhanced and Ethernet PLC-5 Programmable Controllers

1784-CP10

To channel 0 of the PLC-5 controller

Terminal cable #4 Terminal modem phone line

1784-CP7

1784-CP5

PLC-5 controller cable #6

1770-KF2 modem cable #4 Terminal modem phone line

To channel 0 of the PLC-controller cable #6 1 modem

1 Requires either a gender changer or one end of cable #2 fitted with a male 25-pin plug.

Publication 1785-UM012D-EN-P - July 2005

Page 364

G-4

Cable Reference

1784-CP5 cable #2

Terminal

1784-CP7

1770-KF2

PLC-5 controller

25-Pin Serial Port Workstation Terminal

1784-CXK

1785-KE Series B

1770-CD PLC-5 controller

Note: 1785-KE Series A uses 1785-CP5 cable and 1785-CP7 adapter with the Enhanced and Ethernet PLC-5 controller

1784-CP11

Terminal cable #6

To channel 0 of the PLC-5 controller modem

Terminal phone line PLC-5 controller

1784-CP6 cable #6

1770-KF2 cable #6 Terminal modem modem phone line

To channel 0 of the PLC-5

1 Requires either a gender changer or one end of cable #2 fitted with a male 25-pin plug.

Publication 1785-UM012D-EN-P - July 2005 cable #6 1 modem

Page 365

Cable Reference

G-5

The specifications for each Allen-Bradley cable used for DH+ communications are shown on the following pages. Refer to the following table for the exact location.

Programming Cable Specifications

For

To

Use this Cable

Workstation

1785-KE

1784-CAK

25-5

Enhanced or Ethernet PLC-5 controller

Workstation (using a 1784-KT, -KT2, -KL, or -KL/B)

1784-CP6

25-6 25-6 25-7

1784-CP with a 1784-CP7 adapter

See Page

1784-CP8 adapter Workstation (using a 1784-KTK1)

1784-CP5 with a 1785-CP7 adapter

25-6

Workstation (using a 9-pin serial cable)

1784-CP10

25-7

Workstation (using a serial 25-pin cable)

1784-CP11

25-8

Workstation (using a 1784-PCMK)

1784-PCM5 with a 1784-CP7 adapter

25-8 and 25-6

Cable - 1784-CAK Connects 1785-KE to WorkstationT 1

15-Pin D-Shell Connector Pin Male 9

1

15

8 1785-KE

9-Pin D-Shell Connector Pin Female 5 1 2.9 m (9.50 ft.)

Workstation

9 6

2 7 3 13 4 5 6 8 11 D-Shell 15-Pin (1785-KE)

1 4 6 2 5 3 7 8 D-Shell 9-Pin Workstation

4 19 36

Publication 1785-UM012D-EN-P - July 2005

Page 366

G-6

Cable Reference

Cable - 1784-CP6 Connects Workstation Using 1784-KT, -KT/2, -KL, or -KL/B to Controller

62 61 Clear 22 43

1 A

62

Pin 1

21 Pin 6

Pin 3

8-Pin Mini-DIN Controller

62-Pin D-Shell Workstation

38 37 36 35 34 33 32 31

Clear Shield Blue

Shield Blue

8 7 6 5 4 3 2 1

Controller 3 2 1 62-Pin D-Shell Workstation

18378

Cable and Adapter - 1784-CP7 Connects to Controller via 9-pin D-Shell of a 1784-CP, -CP5, or -PCM5 cable

Clear

5 1

9 6

Pin 1 Pin 6

9-Pin D-Shell

8-Pin Mini-DIN Controller

Pin 3

9 8 7 6 5 4 3 2 1

Shield

Shield

Blue

Blue

8 7 6 5 4 3 2 1 8-Pin Mini-DIN Controller

Clear

9-Pin D-Shell 18377

Publication 1785-UM012D-EN-P - July 2005

Page 367

Cable Reference

G-7

Cable Adapter - 1784-CP8 Connects a Workstation Using a 1784-KT, -KT2, or -KL Card to a Permanent DH+ Network 1 2 SH 1

2 3

3-position terminal connector

33

3-position terminal connector

Workstation (front) 62-position sub-miniature connector

34 35

Network (back)

36

Blue

2

Shield

SH

Clear

1

62-position 37 sub-miniature connector

1770-CD Twinax Cable

60 61 62

19816

Cable - 1784-CP10 Connects Workstation to Controller Using Serial Port

3.2m (10 ft) 6

1

9

5

14

25 9-pin D-Shell Female

25-pin D-Shell PLC-5 Controller Male

RXD GND

2

2

5

7

TXD

3

3

DTR

4 6

4 5

RTS

DSR RTS

7

6

DSR

CTS

8

8

DCD

1

13

CTS

20 DTR 19870

Publication 1785-UM012D-EN-P - July 2005

Page 368

G-8

Cable Reference

Cable - 1784-CP11 Controller to Workstation Using a Serial Port

3.2m (10 ft)

1

14

25

14

13

25

25-pin D-Shell Workstation Female

25-pin D-Shell Controller Male

TXD

2

GND

7

3 7

RXD

3

2

RTS

4

CTS

5

4 5

RTS CTS

DSR

6

DCD

8

6 8

DSR DCD

DTS

20

20 DTR

1

13

19871

Cable - 1784-PCM5 Controller to Workstation (using a 1784-PCMK)

124.25 in

6

1

9

5 Controller DH+ 9-pin

Workstation

CLR

LINE 1 CLR

BLUE

LINE 2 CLR

DRAIN

DRAIN

1 5

1 2

7

3 SHIELD

SHIELD

SHELL

SHELL

1

2

BLACK WHITE

DRD

3

RED

3

RET

4

GREEN

4

EN

5

BROWN

5

6

6

7

BLUE ORANGE

8

YELLOW

8 9

DTD

1

SY

TD RET RIO

2

7

DTR SY

9

PURPLE

10

GRAY

10

RTS

11

PINK

11

CTS

12

TAN

12

SHELL SHELL

DRAIN SHIELD

SHELL SHELL

19872

Publication 1785-UM012D-EN-P - July 2005

Page 369

Cable Reference

G-9

Ethernet Cable Connections The Ethernet port connects to either a thin-wire or thick-wire network via a 15-pin transceiver or Medium Access Unit (MAU) connection.

Transceiver

Transceiver

Ethernet Network

To connect a programming terminal to a PLC-5/20E, -5/40E, or -5/80E controller through an Ethernet network, use the following: Ethernet PCMCIA or PC/AT-compatible (6628-A5) communication card Ethernet cable Transceivers and transceiver cables

Transceiver Cable AUI port Transceiver Cable

Ethernet interface card

Workstation

PLC-5/40E

The table below describes Allen-Bradley transceivers: Catalog Number

Description

1785-TR10BT

Twisted pair transceiver

1785-TR10BF

Optical transceiver

1785-TR10B2

Thin-wire transceiver

1785-TR10B5

Thick-wire transceiver

5810-AXMT

Thin-wire Ethernet/802.3 transceiver

5810-AXMH

Thick-wire Ethernet/802.3 transceiver

Publication 1785-UM012D-EN-P - July 2005

Page 370

G-10

Cable Reference

The controller connects to the transceiver using a standard transceiver cable, which is also known as an Access Unit Interface (AUI) cable. Allen-Bradley has two lengths of transceiver cables and four kits consisting of transceivers and cables. Catalog Number

Description

5810-TER

Thinwire Ethernet terminating resistors

5810-TC02/A

Thick-wire 2.0 m (6.5 ft) transceiver cable

5810-TC15/A

Thick-wire 15.0 m (49.2 ft) transceiver cable

5810-TAS/A (kit)

Thin-wire transceiver and 2.0 m (6.5 ft) cable

5810-TAM/A (kit)

Thin-wire transceiver and 15.0 m (49.2 ft) cable

5810-TBS/A (kit)

Thick-wire transceiver and 2.0 m (6.5 ft) cable

5810-TBM/A (kit)

Thick-wire transceiver and 15.0 m (49.2 ft) cable

Connection to “10baseT” (fiber-optic) and broadband networks is also supported if you purchase the appropriate transceivers and cables from a third-party source.

Publication 1785-UM012D-EN-P - July 2005