Manual · Allen-Bradley
Enhanced and Ethernet PLC-5 Programmable Controllers User Manual
Manual388 pagesPDF 5.1 MB
User manual for the Allen-Bradley Enhanced and Ethernet PLC-5 programmable controllers, including the 1785-L20B and 1785-L40B.
Covers · 2 models
The models it covers
Summary
What is in it
Rockwell Automation user manual for the Enhanced and Ethernet PLC-5 programmable controllers (1785-L11B, -L20B, -L30B, -L40B, -L40L, -L60B, -L60L, -L80B, -L20E, -L40E, -L80E, -L26B, -L46B, -L86B). It covers laying out the system, selecting and placing I/O, addressing I/O and controller memory, communicating over remote I/O, extended-local I/O, DH+, serial and Ethernet links, protecting programs, fault and power-up routines, interrupts, and system specifications.
Its parts
- Understanding Your Programmable Controller
- Selecting and Placing I/O
- Placing System Hardware
- Addressing I/O and Controller Memory
- Communicating with Controller-Resident I/O
- Communicating with Remote I/O
- Communicating with a PLC-5 Adapter Channel
- Communicating with Extended-Local I/O
- Communicating with Devices on a DH+ Link
- Communicating with Devices on a Serial Link
- Communicating with Devices on an Ethernet Network
- Protecting Your Programs
- Programming Considerations
- Preparing Power-Up Routines
- Preparing Fault Routines
From the manual
Key facts from this manual
Each line names its page in the PDF.
User manual (publication 1785-UM012D-EN-P, July 2005) for the Enhanced and Ethernet PLC-5 programmable controllers 1785-L11B, -L20B, -L30B, -L40B, -L40L, -L60B, -L60L, -L80B, -L20E, -L40E, -L80E, -L26B, -L46B and -L86B. It helps the reader design, operate and maintain a PLC-5 system, from front panels, channels, memory and battery to troubleshooting by the indicator lights.
- Device
- Enhanced PLC-5 programmable controller; PLC-5/20 is 1785-L20B and PLC-5/40 is 1785-L40B p. 1, 270
- Serial port (channel 0)
- 25-pin D-shell, RS-232C and RS-423, RS-422A compatible, optically coupled; ASCII or DF1 protocols p. 21, 23
- Channel 0 defaults
- DF1 point-to-point, 2400 bps, no parity, one stop bit, BCC error check, no handshaking p. 21, 23
- Battery
- 1770-XYC lithium battery (0.65 grams of lithium); BATT indicator lights red when it is low p. 21, 272
- EEPROM memory modules
- 1785-ME16 (16K words), 1785-ME32 (32K words), 1785-ME64 (64K words), 1785-ME100 (100K words) p. 272
- Keyswitch modes
- RUN, PROG and REM; in REM the software switches between remote program, remote test and remote run p. 27
- Front indicators
- Battery, RUN/FAULT, force and channel 0 indicators, plus a status indicator for each channel p. 21, 23
- 1785-L20B channels
- PLC-5/20: channel 1A is a dedicated 3-pin DH+ port; channel 1B defaults to remote I/O scanner; 8-pin mini-DIN DH+ programming connection p. 21
- 1785-L40B channels
- PLC-5/40: channels 1A, 1B, 2A, 2B; 1A defaults to DH+ at 57.6 kbps, 1B to remote I/O scanner, 2A and 2B unused p. 23
- 3-pin port options
- Remote I/O scanner, remote I/O adapter, DH+ communication or unused p. 21, 23
- 1785-L20B memory
- PLC-5/20: 16K words of user memory (16,384 words) p. 270, 273
- 1785-L40B file limit
- PLC-5/40: limit of 32K words per data table file p. 271
- Publication
- 1785-UM012D-EN-P, July 2005 p. 3
What this manual walks you through
- Laying out the system and its networks p. 19, 20
- Identifying the front-panel parts of each controller p. 20, 21, 22, 23, 24, 25, 26
- Using the keyswitch to change the operating mode p. 27
- Comparing memory, I/O and ports across the controller models p. 270, 271
- Battery life estimates and EEPROM memory backup p. 272, 273
- Troubleshooting the controller by its indicators p. 350, 351
- Troubleshooting remote I/O and DH+ communication channels p. 352
- Troubleshooting the 1771-ASB remote I/O adapter p. 354, 355
Good to know
- In run mode you cannot create or delete program or data files, edit online, or change modes from the software. p. 27
- Channel 0 works with most RS-422A equipment only without termination resistors and with distance and rate reduced to RS-423 limits. p. 21
- An EEPROM saved on a series D revision B, series E revision A or series E revision B controller cannot be loaded on one with an earlier firmware release. p. 273
- Restoring from the EEPROM when controller memory is bad sets the status file date and time to when the EEPROM was saved. p. 272
Questions this manual answers
What battery does the 1785-L20B or 1785-L40B take?
The Enhanced and Ethernet PLC-5 controllers use the 1770-XYC lithium battery. p. 272
What are the default settings of the PLC-5 serial port?
Channel 0 defaults to DF1 point-to-point at 2400 bps, no parity, one stop bit, BCC error check and no handshaking. p. 21
What does a blinking red PROC light on a PLC-5 mean?
A major fault, or an RSLogix 5 download in progress; if no download is running, check the major fault bit S:11, clear the fault and return to run mode. p. 350
What does the red battery indicator on a PLC-5 mean?
It warns that the battery is low. The manual's battery durations count from when the LED first lights, with the battery as the only power. p. 21, 272
Which EEPROM memory modules fit the Enhanced PLC-5?
1785-ME16, 1785-ME32, 1785-ME64 and 1785-ME100, holding 16K, 32K, 64K and 100K words. p. 272
Contents
Chapters and sections
Each line opens the PDF at its page.
- Enhanced and Ethernet PLC-5 Programmable Controllers User Manual1
- Important User Information2
- Summary of Changes3
- Preface15
- Chapter 1 - Understanding Your Programmable Controller19
- Understanding Your Programmable Controller19
- Using This Chapter19
- Lay Out the System19
- Identifying Controller Components20
- Programming Features28
- Using a Controller Channel as a Remote I/O Scanner29
- Using a Controller Channel as a Remote I/O Adapter30
- Using a PLC-5/40L, -5/60L Programmable Controller as an Extended-Local I/O Scanner32
- Chapter 2 - Selecting and Placing I/O33
- Chapter 3 - Placing System Hardware37
- Chapter 4 - Addressing I/O and Controller Memory45
195 more lines, from page 45 on
- I/O Addressing Concept45
- Chapter 5 - Communicating with Controller-Resident I/O69
- Chapter 6 - Communicating with Remote I/O73
- Communicating with Remote I/O73
- Using This Chapter73
- Selecting Devices That You Can Connect74
- Introduction to Remote I/O75
- Designing a Remote I/O Link76
- Configuring a Controller Channel as a Scanner78
- Communicating to a Remote I/O Node Adapter83
- Transferring Block Data85
- Block-Transfers of Remote I/O Data87
- Block-Transfer Sequence with Status Bits89
- Block-Transfer Programming Considerations91
- Monitoring Remote I/O Scanner Channels93
- Addressing the I/O Status File96
- Chapter 7 - Communicating with a PLC-5 Adapter Channel99
- Chapter 8 - Communicating with Extended-Local I/O119
- Chapter 9 - Communicating with Devices on a DH+ Link133
- Communicating with Devices on a DH+ Link133
- Using This Chapter133
- Selecting Devices That You Can Connect133
- Link Design134
- Configuring the Channel for DH+ Communication135
- Using the Global Status Flag File137
- Monitoring DH+ Communication Channels139
- Estimating DH+ Link Performance144
- Application Guidelines149
- Notes150
- Chapter 10 - Communicating with Devices on a Serial Link151
- Chapter 11 - Communicating with Devices on an Ethernet Network175
- Communicating with Devices on an Ethernet Network175
- Using This Chapter175
- Media and Cabling175
- Assigning Your IP Address176
- Network Addressing176
- Configuring Channel 2 for Ethernet Communication176
- Using Advanced Ethernet Functions183
- Using Domain Name Service189
- Using the Embedded Web Server190
- Using Multihop Messaging203
- Communicating with ControlLogix Devices206
- TCP/IP206
- Interpreting Error Codes207
- Interpreting Ethernet Status Data208
- Ethernet PLC-5 Performance Considerations211
- Chapter 12 - Protecting Your Programs213
- Protecting Your Programs213
- Using This Chapter213
- About Passwords and Privileges214
- Defining Privilege Classes215
- Assigning a Privilege Class to a Channel or Offline File216
- Assigning a Privilege Class to a Node216
- Assigning Read/Write Privileges to a Program File217
- Assigning Read/Write Privileges to a Data File217
- Notes218
- Chapter 13 - Programming Considerations219
- Chapter 14 - Preparing Power-Up Routines235
- Chapter 15 - Preparing Fault Routines239
- Chapter 16 - Using Main Control Programs253
- Chapter 17 - Using Selectable Timed Interrupts259
- Chapter 18 - Using Processor Input Interrupts263
- Appendix A - System Specifications269
- Appendix B - Processor Status File275
- Appendix C - Maximizing System Performance287
- Maximizing System Performance287
- Using This Chapter287
- Program Scan287
- Input and Output Modules Delay292
- I/O Backplane Transfer292
- Remote I/O Scan Time292
- Controller Time297
- Example Calculation298
- Performance Effects of Online Operations298
- Effect of Inserting Ladder Rungs at the 56K-word Limit299
- Using Program Control Instructions300
- Appendix D - Instruction Set Quick Reference301
- Appendix E - Switch Setting Reference339
- Appendix F - Troubleshooting349
- Appendix G - Cable Reference361
- Index371
- How Are We Doing?383
- Back Cover388
The whole text · 45 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- Table of Contents5-14
- Preface15-18
- Chapter 1 - Understanding Your Programmable Controller19-32
- Chapter 2 - Selecting and Placing I/O33-36
- Chapter 3 - Placing System Hardware37-44
- Chapter 4 - Addressing I/O and Controller Memory, pages 45 to 5245-52
- Chapter 4 - Addressing I/O and Controller Memory, pages 53 to 6053-60
- Chapter 4 - Addressing I/O and Controller Memory, pages 61 to 6861-68
- Chapter 5 - Communicating with Controller-Resident I/O69-72
- Chapter 6 - Communicating with Remote I/O, pages 73 to 8173-81
- Chapter 6 - Communicating with Remote I/O, pages 82 to 9082-90
- Chapter 6 - Communicating with Remote I/O, pages 91 to 9891-98
- Chapter 7 - Communicating with a PLC-5 Adapter Channel, pages 99 to 10899-108
- Chapter 7 - Communicating with a PLC-5 Adapter Channel, pages 109 to 118109-118
- Chapter 8 - Communicating with Extended-Local I/O119-132
- Chapter 9 - Communicating with Devices on a DH+ Link, pages 133 to 141133-141
- Chapter 9 - Communicating with Devices on a DH+ Link, pages 142 to 150142-150
- Chapter 10 - Communicating with Devices on a Serial Link, pages 151 to 158151-158
- Chapter 10 - Communicating with Devices on a Serial Link, pages 159 to 166159-166
- Chapter 10 - Communicating with Devices on a Serial Link, pages 167 to 174167-174
- Chapter 11 - Communicating with Devices on an Ethernet Network, pages 175 to 184175-184
- Chapter 11 - Communicating with Devices on an Ethernet Network, pages 185 to 194185-194
- Chapter 11 - Communicating with Devices on an Ethernet Network, pages 195 to 204195-204
- Chapter 11 - Communicating with Devices on an Ethernet Network, pages 205 to 212205-212
- Chapter 12 - Protecting Your Programs213-218
- Chapter 13 - Programming Considerations, pages 219 to 226219-226
- Chapter 13 - Programming Considerations, pages 227 to 234227-234
- Chapter 14 - Preparing Power-Up Routines235-238
- Chapter 15 - Preparing Fault Routines239-252
- Chapter 16 - Using Main Control Programs253-258
- Chapter 17 - Using Selectable Timed Interrupts259-262
- Chapter 18 - Using Processor Input Interrupts263-268
- Appendix A - System Specifications269-274
- Appendix B - Processor Status File275-286
- Appendix C - Maximizing System Performance287-300
- Appendix D - Instruction Set Quick Reference, pages 301 to 310301-310
- Appendix D - Instruction Set Quick Reference, pages 311 to 320311-320
- Appendix D - Instruction Set Quick Reference, pages 321 to 330321-330
- Appendix D - Instruction Set Quick Reference, pages 331 to 338331-338
- Appendix E - Switch Setting Reference339-348
- Appendix F - Troubleshooting349-360
- Appendix G - Cable Reference361-370
- Index371-382
- Pages 383 to 388383-388
The file