Guard I/O DeviceNet Safety Modules User Manual: 1 - About the Modules
Pages 13 to 24 of 178, from Guard I/O DeviceNet Safety Modules User Manual
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 1791DS-IB8XOB8 and Allen-Bradley 1791DS-IB12
Page 13
Chapter
1
About the Modules
Topic
Page
Understand Suitability for Use
14
Follow Precautions for Use
14
Precautions to Mount, Wire, and Clean
17
I/O Module Overview
17
Guard I/O Catalog Numbers
19
About CIP Safety in DeviceNet Safety Architectures
19
Identify Major Parts of the Modules
21
This chapter includes important overview information and precautions for using Guard I/O modules that implement the DeviceNet safety protocol. Also included is an overview of how these Guard I/O modules are used within a safety system.
Before You Begin
Always observe the following guidelines when using a module, noting that in this manual we use safety administrator to mean a person qualified, authorized, and responsible to secure safety in the design, installation, operation, maintenance, and disposal of the machine. • Thoroughly read and understand this manual before installing and operating the module. • Keep this manual in a safe place where personnel can refer to it when necessary. • Use the module properly according to the installation environment, performance, and functions of the machine. • Verify that a safety administrator conducts a risk assessment on the machine and determines module suitability before installation. • Verify for CE LVD compliance, the external power supply that provides power to the modules is safety extra-low voltage (SELV) rated. Some Rockwell Automation Bulletin 1606 power supplies are SELV-compliant. Verify this in the Bulletin 1606 Installation Instructions. Verify that the Guard I/O firmware version is correct prior to commissioning the safety system, noting that firmware information related to safety controllers is available at http://www.rockwellautomation.com/products/certification/safety.
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013
13
Page 14
Chapter 1
About the Modules
Understand Suitability for Use
Rockwell Automation is not responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in your application or use of the product. Take all necessary steps to determine the suitability of the product for the systems, machine, and equipment with which it is used. Know and observe all prohibitions of use applicable to this product. Never use the products for an application involving serious risk to life or property without making sure that the system as a whole was designed to address the risks and that the Rockwell Automation product is properly rated and installed for the intended use within the overall equipment or system.
Follow Precautions for Use ATTENTION: Safety state of the inputs and outputs is defined as the off state. Safety state of the module and its data is defined as the off state. Use the Guard I/O module only in applications where the off state is the safety state. Serious injury may occur due to breakdown of safety outputs. Do not connect loads beyond the rated value to the safety outputs. Serious injury may occur due to loss of required safety functions. Wire the module properly so that supply voltages or voltages for loads do not touch the safety outputs accidentally or inadvertently.
ATTENTION: Use DC supply satisfying the following requirements to prevent electric shock: • A DC power supply with double or reinforced insulation, for example, according to IEC/EN 60950 or EN 50178 or a transformer according to IEC/EN 61558 • A DC supply satisfies requirement for class 2 circuits or limited voltage/current circuit stated in UL 508 • Use an external power supply that is safety extra-low voltage (SELV) rated
14
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013
Page 15
About the Modules
Chapter 1
ATTENTION: Follow these precautions for safe use. • Wire conductors correctly and verify operation of the module before placing the system into operation. Incorrect wiring may lead to loss of safety function. • Do not apply DC voltages exceeding the rated voltages to the module. • Apply properly specified voltages to the module inputs. Applying inappropriate voltages may cause the module to fail to perform it’s specified function, which could lead to loss of safety functions or damage to the module. • Never use test outputs as safety outputs. Test outputs are not safety outputs. • Note that after installation of the module, a safety administrator must confirm the installation and conduct trial operation and maintenance. • Do not disassemble, repair, or modify the module. This may result in loss of safety functions. • Use only appropriate components or devices complying with relevant safety standards corresponding to the required safety category and safety integrity level. - Conformity to requirements of the safety category and safety integrity level must be determined for the entire system. - We recommend you consult a certification body regarding assessment of conformity to the required safety integrity level or safety category. • Note that you must confirm compliance with the applicable standards for the entire system. • Disconnect the module from the power supply before wiring. Devices connected to the module may operate unexpectedly if wiring is performed while power is supplied.
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013
15
Page 16
Chapter 1
About the Modules
For 1791DS-IB4XOW4 modules, follow these instructions on isolating transformer use. Refer to the isolating transformer figure. • Use an isolating transformer to isolate between over-voltage category III and II, such as TR1, to conform to IEC 60742. • Be sure the insulation between first input and secondary output satisfies at least basic insulation of over-voltage category III. • Be sure one side of a secondary output of the isolating transformer is grounded to prevent electric shock to personnel due to a short to ground or short to the frame of the isolating transformer. • Insert fuses, in case of a short to the frame, to protect the isolating transformer and prevent electric shock to personnel, per transformer specifications, at points such as F1, F2, and F3. Figure 1 - Use of Isolating Transformer 1791DS-IB4XOW4 Module 400V AC/ 230V AC L1
L2 L3
F4
F5 MA
MB
F3
F1 TR1 F6
F7
F8
F2
MA F1…F8 - Fuses MA, MB - Electromagnetic Switches TR1 - Insulated Transformer
MB
Load III
Over-voltage Category
II 44151
16
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013
Page 17
About the Modules
Precautions to Mount, Wire, and Clean
Chapter 1
Observe these precautions to prevent operation failure, malfunctions, or undesirable effects on product performance. Follow these precautions when mounting modules: • Use DIN rail that is 35 mm (1.38 in.) wide to mount the module into the control panel. • Mount modules to DIN rail securely. • Leave at least 50 mm (1.96 in.) above and below the module to allow adequate ventilation and room for wiring for 1791DS-IB12, 1791DSIB8XOB8, and 1791DS-IB4XOW4 modules. • Leave at least 15 mm (0.6 in.) around the module to allow adequate ventilation and room for wiring for 1732DS-IB8, 1732DS-IB8XOBV4, 1791DS-IB8XOBV4, and 1791DS-IB16 modules. Follow these precautions when wiring modules: • Do not place communication lines and I/O lines in the same wiring duct or track as high voltage lines. • Wire correctly after confirming the signal names of all terminals. • Do not remove the shield from a module before wiring, but always remove the shield after completing wiring to be sure of proper heat dispersion for 1791DS-IB12, 1791DS-IB8XOB8, and 1791DS-IB4XOW4 modules. • Follow torquing specifications as indicated in the installation instructions. When cleaning modules, do not use the following: • Thinner • Benzene • Acetone
I/O Module Overview
The Guard I/O modules implement the CIP-safety protocol extensions over DeviceNet networks and provide various features for a safety system. Use the modules to construct a safety-control network system that meets the requirements up to Safety Integrity Level 3 (SIL 3) as defined in IEC 61508, Functional Safety of Electrical, Electronic, and Programmable Electronic Safetyrelated Systems, and the requirements for Safety Category 4 of the EN 954-1 standard, Safety of machinery - Safety related parts of control systems. All 1791DS modules can be mounted vertically or horizontally. Remote I/O communication for safety I/O data are performed through safety connections supporting CIP safety over a DeviceNet network. Data processing is performed in the safety controller. The status and fault diagnostics of Guard I/O modules are monitored by a safety controller through a safety connection using a new or existing DeviceNet network.
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013
17
Page 18
Chapter 1
About the Modules
The following is a list of features common to Guard I/O modules: • CIP-safety and DeviceNet protocol conformance • Safety inputs – Safety devices, such as emergency stop push buttons, gate switches, and safety light curtains, can be connected. – Dual-channel mode evaluates consistency between two input signals (channels), which allows use of the module for Safety Category 3 and 4. – The time of a logical discrepancy between two channels can be monitored using a discrepancy time setting. – An external wiring short-circuit check is possible when inputs are wired in combination with test outputs. The module must be wired in combination with test outputs when this function is used. – Independently adjustable on and off delay is available per channel. • Test outputs – Separate test outputs are provided for short circuit detection of a safety input (or inputs). – Power (24V) can be supplied to devices, such as safety sensors. – Test outputs can be configured as standard outputs. – All Guard I/O modules have numerous test outputs, of which some can be used for broken wire detection of a muting lamp. • Safety outputs – Solid state outputs • Dual-channel mode evaluates consistency between two output signals (channels). • Safety outputs can be pulse tested to detect field wiring shorts to 24V DC. • All 1791DS-IB8XOBV4 modules’ safety outputs use pulse testing to detect a short to 24V DC on the safety source output (P), and a short to 0V DC on the safety sink output (M). – Relay Outputs • Dual-channel mode evaluates consistency between two output signals (channels). • Up to 2 A is provided per output point. • Safety relays can be replaced. • I/O status data - In addition to I/O data, the module includes status data for monitoring I/O circuits. • Security - The configuration information of the module can be protected by a password. • Removable I/O connectors - I/O connectors support mechanical keying.
18
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013
Page 19
About the Modules
Chapter 1
Use the minimum software versions listed here.
Programming Requirements Cat. No.
Studio 5000 Environment Version(1)
RSLogix 5000 Software Version(1) (EtherNet/IP Network)
RSNetWorx for DeviceNet RSLinx Software Software Version(1) Version(1) (DeviceNet Network)
1732DS-IB8, 1732DS-IB8XOBV4, 1791DS-IB12, 1791DS-IB8XOB8, 1791DS-IB4XOW4, 1791DS-IB8XOBV4, 1791DS-IB16
21
17
8
2.51
(1) This version or later.
Guard I/O Catalog Numbers Cat. No.
See the table for a listing of the types of Guard I/O modules.
Description
Enclosure Type Safety Inputs Test Outputs Rating
Safety Outputs Solid State
Relays
1732DS-IB8
Safety input module
-
-
Safety I/O module with solid state outputs
Meets IP64/65/ 8 67 8
8
1732DS-IB8XOBV4
8
4 bipolar pairs
-
1791DS-IB12
Safety input module
Meets IP20
12
4
-
-
1791DS-IB8XOB8
Safety I/O module with solid state outputs
8
4
8
-
1791DS-IB4XOW4
Safety I/O module with relay outputs
4
4
-
4
1791DS-IB8XOBV4
Safety I/O module with solid state outputs
8
8
4 bipolar pairs
-
1791DS-IB16
Safety input module
16
16
-
-
About CIP Safety in DeviceNet Safety Architectures
Use Guard I/O modules in DeviceNet safety architectures as shown below. The Guard I/O family is a set of I/O modules that when connected to a DeviceNet safety network are suitable for applications up to SIL3, as defined in the IEC 61508 standard, and Safety Category 4, as defined in the EN 954-1 standard.
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013
19
Page 20
Chapter 1
About the Modules
Figure 2 - Guard I/O Modules in DeviceNet Safety Architectures Logix Controller
GuardLogix Controller Guard PLC Controller
SmartGuard 600 Controller
DeviceNet Scanner Interface
Logix Controller
DeviceNet Network CompactBlock Guard I/O Module
RSNetWorx, Studio 5000, and RSLogixGuard Plus Software ArmorBlock Guard I/O Module
44196
Safety Communication Standard Communication
Safety controllers control the safety outputs. Safety or standard PLC controllers can control the standard outputs.
20
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013
Page 21
About the Modules
Identify Major Parts of the Modules
Chapter 1
See the figures for module identification. For pin-out information, refer to the relevant installation instructions. Figure 3 - 1791DS-IB4XOW4 Module Identification Status Indicators
Node Address Switches
Safety Relay
Communication Connector
I/O Connections
44195
Figure 4 - 1791DS-IB8XOB8 Module Identification Status Indicators
Node Address Switches
IN PWR
MS NS LOCK
0 1 2 3 4 5 6 7
OUT PWR
1791DS-IB8XOB8
0 1 2 3 4 5 6 7
CompactBlock 8 Inputs - 8 Outputs 24VDC
Communication Connector
44091
I/O Connections
Figure 5 - 1791DS-IB12 Module Identification Status Indicators
Node Address Switches
MS NS LOCK
IN PWR
0 1 2 3 4 5 6 7
8 9 10
11
CompactBlock 12 Inputs 24VDC
1791DS-IB12
Communication Connector
44091
I/O Connections
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013
21
Page 22
Chapter 1
About the Modules
Figure 6 - 1791DS-IB8XOBV4 Module Identification Power Connector
I/O Connectors (output)
0
0 8 6
2 X10
Status Indicators
8
2
4 4 NODE 6 X1 ADR
Communication Connector
44224
I/O Connectors (input)
Node Address Switches
Figure 7 - 1732DS-IB8 Module Identification Node Address Switches
Communication Connector
44123
I/O Power
Inputs Status Indicators
FE
Figure 8 - 1732DS-IB8XOBV4 Module Identification Outputs
Node Address Switches
Communication Connector
44122
Inputs
Status Indicators
FE
I/O Power
22
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013
Page 23
About the Modules
Chapter 1
Figure 9 - 1791DS-IB16 Module Identification Power Connector
I/O Connectors (input)
FE
I8
I9
T8
T9
I10
I11
T10
T11M
2 X10
I13
T12
T13
I14
I15
T 14
T15M
I4
I5
T4
T5
I6
I7
T6
T7M
0
0 6
I12 1791DSIB16
NC NC
8
Status Indicators
8
2
4 4 NODE 6 X1 ADR
16 INPUTS 24 Vdc FE
I0
I1
Communication Connector
T0
T1
I2
I3
T2
T3M
44118
I/O Connectors (input)
Node Address Switches
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013
23
Page 24
Chapter 1
About the Modules
Notes:
24
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013