FLEX I/O PROFIBUS Adapter (Cat. No. 1794-APB) User Manual: Glossary
Pages 78 to 85 of 90, from FLEX I/O PROFIBUS Adapter (Cat. No. 1794-APB) User Manual
The original document is the PDF (924 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 1794-IB16
Page 78
Glossary This Glossary contains terms specific to Allen-Bradley and PROFIBUS FMS and DP. Allen-Bradley communication defaults values used for communication configuration data such as OD, CRL ( for FMS) DP slave database,and bus parameters whenever the coprocessor’s working RAM configuration is reinitialized. application layer the seventh layer of the seven-layer OSI reference model. This layer is where the coprocessor first interacts with the application program. baud rate the speed of communication between devices on the network. All devices must communicate at the same rate. broadcast relationships allow transmission of messages to all nodes simultaneously, but only unconfirmed services are available. bus parameters communication parameters used by Link Layer. Main Bus Parameters are station address, maximum address and baud rate. These can be changed using the Local Station Manager or PROFIBUS Manager. client the FMS device that makes use of resources to perform some type of application function. CLOSE command in FMS, terminates the connection with a remote node on the network. communication object model describes the externally visible behavior associated with an FMS service or group of services. Three types of communication object models are domain objects, program invocation objects and variable objects. CREF communication reference. In FMS, an index assigned to each entry connection defined in the CRL. CSTAT a qualifier that allows to save the status of a connection. communication parameters parameters within the PROFIBUS communication layers that control the communication process. They are used to configure and indicate current status of communication and consist of the OD, CRL, bus parameters for FMS, and slave database and bus parameters for DP.
Publication 1794-6.5.6 – April 1996
Page 79
GB–2
Glossary communication relationship in FMS, defines all the parameters for the communication between two nodes. configuration management in FMS, set of FMA 7 services to upload and download the PROFIBUS bus parameters, CRL, and to read SAP status and station identification. connector header a connector that attaches between the processor and coprocessor and provides communication between the two modules. connection type in FMS, the type of connection between two nodes. There are three connection types: defined (D), open at the responder (O), and open at the initiator (I) connection zero opens automatically during the coprocessor’s power-up and allows access to local data either by physical addressing or via objects defined locally in the OD. consistency the DP protocol allows to associate data consistency requirements with blocks of data exchanged between a PLC master and its slaves. A consistent block of data must always be written or read as a whole, because contained data is not independent. For example, when it holds both real data and data identification, or when granularity exceeds 2 bytes (e.g. floating point data). context management set of FMA 7 services that establishes and releases connections coprocessor the 1785-PFB/B PROFIBUS Coprocessor module CRL Communication Relationship List. In FMS, a CRL is a database within the station, holding the description of all communication relationships of that station to all other stations, independent of the time of use. For more information on CRLs, refer to DIN 19245 Part 2: Process Field Bus. default settings values used for communication configuration data such as OD, CRL ( for FMS) DP slave database,and bus parameters whenever the coprocessor’s working RAM configuration is reinitialized.
Publication 1794-6.5.6 – April 1996
Page 80
Glossary
GB–3 defined connection in FMS, a connection type that specifies both end nodes of the channel by giving their network address and the FDL service access points (SAPs) used in both nodes diagnostics three LED indicators located on the front panel of the coprocessor provide the user with the status of the coprocessor and its communication channels. Also referred to as user interface. domain object in FMS, represents a portion of the processor’s memory image. In the coprocessor, represents the processor’s entire memory image. DIN Deutsches Institut fur Normung. The German Normalization Agency. DP Decentralized Periphery. A German/European standard (DIN 19245 Part 3) that specifies a simplified user interface with PROFIBUS link layer services and protocol to use with decentralized peripherals. DP interface a 9-pin female D-shell connector located at Port 2 on the front panel of the coprocessor. EC 96 European Community 1996. European Union Directives for 1996. EMC Electro-magnetic Compatibility. ESD Electrostatic Discharge. Can cause internal circuit damage to the coprocessor. FDL Fieldbus Data Link. A German standard (DIN 19245 Part 1) that specifies the Data Link layer of the PROFIBUS fieldbus. FMA Fieldbus Management. A German standard (DIN 19245 Parts 1 and 2) that specifies the network management services and protocol of the PROFIBUS fieldbus. FMS Fieldbus Message Specification. A German standard (DIN 19245 Part 2) that specifies the Application Layer services and protocol of the PROFIBUS fieldbus. Publication 1794-6.5.6 – April 1996
Page 81
GB–4
Glossary
FMS interface a 9-pin female D-shell connector located at Port 1 on the front panel of the coprocessor. FMS Physical Access Addressing FMS option that allows the access of data at a physical address by specifying the address in the service. FMS Symbolic Access Addressing FMS option that allows to statically associate a symbolic name or short reference number (or index) with a physical address within a node. fault management set of FMA 7 services that allows resetting the communication and indicates communication faults and events HPRIO High Priority service request. A qualifier to specify high priority for unconfirmed services such as UINFO and USTAT. I/O chassis the chassis or rack that serves as the location for the processor, coprocessor, power supply and other I/O modules. Also referred to as chassis. LED Light-emitting diode. link layer defines a hybrid method for accessing the communication medium (bus) with master/active stations or slave/passive stations. Local Station Manager an Allen-Bradley PC program that runs under Microsoft Windows version 3.1. This program transfers data (FDL,CRL, OD, station address, communication rate, and maximum station address) between the PC and the coprocessor over RS-232. logical module DP protocol describes I/O data exchanged between a PLC master and a slave device as a set of logical modules (up to 64, but 32 preferred) each one featuring up to 16 bits maximum of inputs, outputs or a combination of both. The actual structure of exchanged input and output frames is deduced from this description. lower layer interface (LLI) in FMS, responsible for interfacing the FMS layer 7 with FDL layer 2. LLI manages connections
Publication 1794-6.5.6 – April 1996
Page 82
Glossary
GB–5
LSAP or SAP Link layer Service Access Point. A logical sub-addresses within devices that allow the distribution of communication flow over dedicated tasks, depending on the required processing. FMS uses LSAPs indifferently to define generic communication relationships between two devices (logical communication channels). DP uses predefined LSAPs to access specific functions or services between masters and slaves. master initiates transfer of messages without any prior remote request. The right to access the bus (token) is circulated among the master stations. Management of this logical token ring is performed automatically by the masters (such as startup, removal or insertion of masters). Also referred to as active stations or scanner. module any of the plug-in hardware devices that are located in the 1771 I/O chassis: processor, coprocessor, power supply or I/O module module slot location in the I/O chassis for installing a module. Each module slides into a module slot that lines up with the backplane connector. Also referred to as slot. multicast relationships allow transmission of messages to a group of nodes simultaneously, but only unconfirmed services are available. network a series of stations or nodes connected by some type of communication medium. A network may consist of a single link or multiple links. node an address or software location on the network. Also referred to as node. STATUS LED a bicolor LED, located on the front panel of the coprocessor that indicates the condition of the coprocessor OD Object Dictionary. In FMS, an OD is a database within the station, holding the description of all explicit communication objects of that station and making them available for control and monitoring.
Publication 1794-6.5.6 – April 1996
Page 83
GB–6
Glossary open at the initiator in FMS, a connection type where the source service access point (SAP) is shared among several communication relationships (associated with a different destination address and SAP). The device uses only one of these relationships at a time, depending on the selected remote node. open at the responder in FMS, a connection type where the destination address and service access point (SAP) are undefined, thus making the connection available to any device. OPEN command in a MSG instruction, establishes a connection between the coprocessor and a remote node on the network OSI Open Systems Interconnect. A standard that provides the framework for defining the process of communication between nodes on the PROFIBUS network. physical layer The first layer of the seven-layer OSI reference model. This layer is where the coprocessor connects to the network media. PICS Protocol Implementation Conformance Statement. System conformance requirements associated with network communications, consisting of four parts: implementation and system information, supported services, supported parameters and their options, and local implementation values PLC-5 processor Any one of the family of Allen-Bradley Programmable Logic Controllers that support the coprocessor interface: PLC-5/11 , -5/20 , -5/30 , -5/40 , -5/60 and -5/80 . PNO PROFIBUS Nutzerorganisation, or PROFIBUS User Organization. PORT 1 LED a bicolor LED, located on the front panel of the coprocessor that indicates the condition of the FMS communication channel of the coprocessor PORT 2 LED a bicolor LED, located on the front panel of the coprocessor that indicates the condition of the DP communication channel of the coprocessor
Publication 1794-6.5.6 – April 1996
Page 84
Glossary
GB–7 power supply module that supplies power to the I/O chassis containing the processor and coprocessor and other modules processor Any one of the family of Allen-Bradley Programmable Logic Controllers that support the coprocessor interface: PLC-5/11 , -5/20 , -5/30 , -5/40 , -5/60 and -5/80 . processor interface a 58-pin connector located on the left side of the coprocessor that uses a PLC-5 Connector Header to attach to the processor for communication between the two modules. PROFIBUS PROcess FIeld BUS. A German standard (DIN 19245 Parts 1, 2 and 3) that specifies a fieldbus for communications at the process level. PROFIBUS Manager an Allen-Bradley PC program that runs under MicrosoftR Windows version 3.1. This program allows you to create, download and monitor network FMS and DP configurations on your personal computer through an RS-232 interface to your coprocessor. program invocation objects allow an FMS client to place the processor into different modes (for example, program, test, run) protocol the language or packaging of information that is transmitted between nodes on a network. qualifier in a MSG instruction, a word that specifies options for an MSG command RFI Radio Frequency Interference. RS-232 communication protocol between the personal computer and the coprocessor RS-232 interface a 9-pin male D-shell connector located at the RS-232 port on the front panel of the coprocessor. Use this interface to connect the Local Station Manager and PROFIBUS Manager installed in your personal computer. server an FMS device that makes resources available for use by another FMS device. Also referred to as slave.
Publication 1794-6.5.6 – April 1996
Page 85
GB–8
Glossary station an address or software location on the network. Also referred to as node. SET command in a MSG instruction, allows transfer of an element, an array of elements or an FMS structure to or from a node on the network. slave are only allowed to transmit immediate acknowledge or immediate response to master requests. At the Link Layer level, any master can access any slave without restrictions. Also referred to as passive stations or adapters. STATUS command in a MSG instruction, retrieves status information from a remote node and stores it locally. system parameters allow you to check the current state of the coprocessor third party multivendor configurator a remote software tool used to define connections between devices and their communication parameters on the network. The tool is available on the open market from many vendors. UINFO command Unsolicited Variable Information. In a MSG instruction, a command that sends unsolicited data such as an element, array of elements or predefined FMS structure. USTAT command Unsolicited Status Information. In a MSG instruction, a command that sends unsolicited status information such as an element, array of elements or predefined FMS structure. user interface three LED indicators located on the front panel of the coprocessor provide the user with the status of the coprocessor and its communication channels. Also referred to as diagnostics. variable objects data that can be accessed from the network within an FMA server. VFD Virtual Field Device. A portion of the FMS server application process that makes a set of resources (data files, program files, I/O) and their associated functionality available for control and monitoring. For more information on VFDs, refer to DIN 19245 Parts 1 and 2: Process Field Bus.
Publication 1794-6.5.6 – April 1996