The text of a manual · part 11 of 13
FLEX I/O PROFIBUS Adapter (Cat. No. 1794-APB) User Manual: B - Device Data Base File
Pages 72 to 77 of 90, from FLEX I/O PROFIBUS Adapter (Cat. No. 1794-APB) User Manual
The original document is the PDF (924 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 1794-IB16
Page 72
Appendix
B
Device Data Base File What this Chapter Contains
This chapter contains an example of the device data base (GSD) file for the 1794-APB Adapter. This file is included on the software diskette you received with your shipment of the FLEX I/O adapter. The GSD file is used by your configuration tool to help you set up your system. Your configuration tool automatically reads the GSD file and extracts defaults used in the data exchange.
Software diskette with GSD file
The file is in ASCII format and you can view it with any text editor. A printed copy of your GSD file appears below. This device data base file changes when new FLEX I/O modules are introduced. When you add new modules to your system, contact your local Allen-Bradley representative for the latest version of this file.
;============================================================ ; Profibus Device Database of : ; Allen–Bradley DP slave ; Model : 1794–APB/A Revision Series A Rev. 1.0 ; Description : Flex I/O Profibus adapter ; Language : English ; Date : 15 February 1996 ; Author : Allen–Bradley ;============================================================ #Profibus_DP AB_GSD_Revision
= ”1.0”
; Device identification Vendor_Name = ”Allen–Bradley” Model_Name = ”1794–APB/A” Revision = ”Series A Rev. 1.0” Ident_Number = 0x1101 Protocol_Ident = 0 ; DP protocol Station_Type = 0 ; Slave device FMS_supp = 0 ; FMS not supported Hardware_Release = ”Series A” Software_Release = ”Rev. 1.0”
Publication 1794-6.5.6 – April 1996
Page 73
B–2
Device Data Base File
; Supported baudrates 9.6_supp = 1 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 0 6M_supp = 0 12M_supp = 0 ; Maximum responder time for supported baudrates MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 ; Supported hardware features Redundancy = 0 ; not supported Repeater_Ctrl_Sig = 0 ; not connected 24V_Pins = 0 ; not connected ; Supported DP features Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Auto_Baud_supp = 1 Set_Slave_Add_supp = 0
; supported
; Maximum Length of User Parameter User_Prm_Data_Len = 237 ; Default User Parameter string : ; Autoconfigure, Reset to Zero, Reset inputs to zero User_Prm_Data = 0x00 ; Maximum polling frequency Min_Slave_Intervall = 10
; 10*100 ¶s => 1 millisecond
; Maximum supported sizes Modular_Station = 1 ; modular Max_Module = 9 ; physical modules = slots Max_Input_Len = 244 Max_Output_Len = 244 Max_Data_Len = 488 ; Meaning of ”device diagnostic” field
Publication 1785-6.5.15 – November 1995
Page 74
Device Data Base File
B–3
;Firmware revisions of device Unit_Diag_Area = 0–15 Value (1) = ”Firmware Rev. : 1.0” Unit_Diag_Area_End Unit_Diag_Bit (16) = ”Node address changed” ;The following byte (corresponding to Unit_Diag_Area = 24–31) contains ;the current setting of the node address switch. ;Please look at the user manual (section ”Troubleshooting”) for a detailed ;explanation about the meaning of these bytes. ; Definition of all available physical modules ;============================================================ ; Empty slot for Flex I/O (2 configuration bytes per slot) Module = ”Flex I/O empty slot” 0x00, 0x00 EndModule ; Flex I/O adapter status (must be the first module in config, 1 word in, 1 word out) Module = ”1794–APB Status” 0x50, 0x60 EndModule ; Definition of modules for autoconfigure and condensed formats ;============================================================ ; Flex I/O module 1794–IB16, 16–point Discrete Input Module (default config= 1 word in, 1 word out) Module = ”1794–IB16” 0x50, 0x60 EndModule ; Flex I/O module 1794–OB16, 16–point Discrete Output Module (default config= 0 word in, 1 word out) Module = ”1794–OB16” 0x00, 0x60 EndModule ; Flex I/O module 1794–IB8S, 8–point config= 1 word in, 1 word out) Module = ”1794–IB8S” 0x50, 0x60 EndModule
Discrete
Sensor
Input
Module
(default
; Flex I/O module 1794–IA8, 8–point Discrete Input Module (default config= 1 word in, 1 word out) Module = ”1794–IA8” 0x50, 0x60 EndModule ; Flex I/O module 1794–OA8, 8–point Discrete Output Module (default config= 0 word in, 1 word out) Module = ”1794–OA8” 0x00, 0x60 EndModule
Publication 1785-6.5.15 – November 1995
Page 75
B–4
Device Data Base File
; Flex I/O module 1794–OW8, 8–point config= 0 word in, 1 word out) Module = ”1794–OW8” 0x00, 0x60 EndModule
Discrete
Relay
Output
Module
(default
; Flex I/O module 1794–IE8, 8 Input Analog Module (default config= 9 words in, 1 word out) Module = ”1794–IE8” 0x58, 0x60 EndModule ; Flex I/O module 1794–OE4, 4 Output Analog Module (default config= 1 word in, 6 words out) Module = ”1794–OE4” 0x50, 0x65 EndModule ; Flex I/O module 1794–IE4XOE2, Analog Combo Module (default config= 5 words in, 4 words out) Module = ”1794–IE4XOE2” 0x54, 0x63 EndModule ; Flex I/O module 1794–IR8, RTD Input Analog Module (default config= 11 words in, 3 words out) Module = ”1794–IR8” 0x5A, 0x62 EndModule ; Flex I/O module 1203–FM1, Flex I/O SCANport Module 1 (default config= 6 words in, 5 words out) Module = ”1203–FM1” 0x55, 0x64 EndModule ; Definition of modules for full format ;============================================================ ; Flex I/O module 1794–IB16, 16–point Discrete Input Module (default config= 1 word in, 0 word out) Module = ”1794–IB16/full format” 0x50, 0x00 EndModule ; Flex I/O module 1794–OB16, 16–point Discrete Output Module (default config= 0 word in, 1 word out) Module = ”1794–OB16/full format” 0x00, 0x60 EndModule ; Flex I/O module 1794–IB8S, 8–point Discrete config= 1 word in, 0 word out) Module = ”1794–IB8S/full format” 0x50, 0x00 EndModule
Sensor
Input
Module
(default
; Flex I/O module 1794–IA8, 8–point Discrete Input Module (default config= 1 word in, 0 word out) Module = ”1794–IA8/full format” 0x50, 0x00 EndModule
Publication 1785-6.5.15 – November 1995
Page 76
Device Data Base File
B–5
; Flex I/O module 1794–OA8, 8–point Discrete Output Module (default config= 0 word in, 1 word out) Module = ”1794–OA8/full format” 0x00, 0x60 EndModule ; Flex I/O module 1794–OW8, 8–point Discrete config= 0 word in, 1 word out) Module = ”1794–OW8/full format” 0x00, 0x60 EndModule
Relay
Output
Module
(default
; Flex I/O module 1794–IE8, 8 Input Analog Module (default config= 9 words in, 0 word out) Module = ”1794–IE8/full format” 0x58, 0x00 EndModule ; Flex I/O module 1794–OE4, 4 Output Analog Module (default config= 1 word in, 4 words out) Module = ”1794–OE4/full format” 0x50, 0x63 EndModule ; Flex I/O module 1794–IE4XOE2, Analog Combo Module (default config= 5 words in, 2 words out) Module = ”1794–IE4XOE2/full format” 0x54, 0x61 EndModule ; Flex I/O module 1794–IR8, RTD Input Analog Module (default config= 11 words in, 0 words out) Module = ”1794–IR8/full format” 0x5A, 0x00 EndModule ; Flex I/O module 1203–FM1, Flex I/O SCANport Module 1 (default config= 4 words in, 3 words out) Module = ”1203–FM1/full format” 0x53, 0x62 EndModule ; Profibus Manager specific parameters AB_Icon_File = ”res\flex.ico” AB_Bitmap_File = ”res\flex.bmp” AB_Attach_Offset = 32 AB_Description = ”Allen–Bradley Flex I/O Profibus adapter” ;============================================================
Publication 1785-6.5.15 – November 1995
Page 77
B–6
Device Data Base File
Publication 1785-6.5.15 – November 1995