Page 1
FLEX I/O Diagnostic Modules Allen-Bradley
Catalog Numbers 1794-IB16D, 1794-OB16D User Manual
Rockwell Allen-Bradley - Rockwell Softwae Mutomation
Page 2
Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://literature.rockwellautomation.com) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING
Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.
IMPORTANT
Identifies information that is critical for successful application and understanding of the product.
ATTENTION
Identifies information about practices or circumstances that can lead to: personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence. SHOCK HAZARD
Labels may be on or inside the equipment, such as a drive or motor, to alert people that dangerous voltage may be present.
BURN HAZARD
Labels may be on or inside the equipment, such as a drive or motor, to alert people that surfaces may reach dangerous temperatures.
Allen-Bradley, Rockwell Automation, FLEX I/O, RSLogix, RSLinx, RSLogix 5000 and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
Page 3
Table of Contents Preface Purpose of This Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Important Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 North American Hazardous Location Approval . . . . . . . . . . . . . . . 7 Related Products and Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Chapter 1 1794 FLEX I/O Diagnostic Digital Modules Overview
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 General Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Network Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 1794-IB16D Diagnostic Input Module Compatibility . . . . . . . . . . 14 1794-OB16D Diagnostic Output Module Compatibility . . . . . . . 15 Install Your Digital Input or Output Module. . . . . . . . . . . . . . . . . . . . 16
Chapter 2 About the FLEX I/O Diagnostic Input Module
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 About the 1794-IB16D Diagnostic Input Module . . . . . . . . . . . . . . . . 19 Diagnostic Fault Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Sensor Power Open and Short Circuit Detection . . . . . . . . . . . . . 22 User Power Supply Reverse Voltage Detection . . . . . . . . . . . . . . . 23 User Power Supply Loss Detection . . . . . . . . . . . . . . . . . . . . . . . . 23 Indicator Status Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Module Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Input Voltage Derating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Sensor-Power Derating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Unused Sensor Power Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Open Contact Mechanical Switches and Relays. . . . . . . . . . . . . . . 25 Sensor Power Internal Voltage Drop . . . . . . . . . . . . . . . . . . . . . . . 25 Configure Your Diagnostic Input Module . . . . . . . . . . . . . . . . . . . . . . 26 Input Filter Times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Chapter 3 About the FLEX I/O Diagnostic Output Module iii
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 About the 1794-OB16D Diagnostic Output Module . . . . . . . . . . . . . 27 Wiring Output Loads. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Diagnostic Fault Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Module Protection Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Output Fault & Idle States With Network Communication Failure . 31 Indicator Status Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Module Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Unused Output Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Configure Your Output Diagnostic Module. . . . . . . . . . . . . . . . . . . . . 32
Publication 1794-UM065B-EN-E - July 2006
Page 4
Table of Contents iv
Chapter 4 Configuring Modules for Communication on a Remote I/O Network
Chapter Objectives. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Add a 1756-DHRIO Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Add a 1794 Remote Adapter Module . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Configure Digital Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Create a Block Transfer (Read or Write) Message Instruction . . . . . . 42 Ladder Logic Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Chapter 5 Configure FLEX I/O Digital How to Use This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Modules on a DeviceNet Network Add the Scanner to the I/O Configuration of the Controller Using
RSLogix 5000 Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 If You Need to Conserve EtherNet/IP or ControlNet Network Bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Add the Scanner to the I/O Configuration Folder . . . . . . . . . . . . 50 Define the Properties of the Scanner . . . . . . . . . . . . . . . . . . . . . . . 51 Determine the Address of DeviceNet Data . . . . . . . . . . . . . . . . . . . . . 52 Tally Memory Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 If You Configure the Adapter Offline . . . . . . . . . . . . . . . . . . . . . . . . . 55 Set the Address of the Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Chapter 6 Configure Your Adapter and Digital Modules on a ControlNet Network
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Set Up the Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Setting a Requested Packet Interval (RPI) . . . . . . . . . . . . . . . . . . . . . . 58 Select a Communication Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Direct or rack-optimized connection . . . . . . . . . . . . . . . . . . . . . . . 61 Ownership . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Add Local and Remote ControlNet Modules. . . . . . . . . . . . . . . . . . . . 65 Add Distributed I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Download the Program to the Controller. . . . . . . . . . . . . . . . . . . . . . . 68 Configure the 1794-ACN15 Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Schedule I/O Module Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Access Module Data via the 1794-ACN15 Adapter. . . . . . . . . . . . . . . 75 Slot Status Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Change Configuration Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Chapter 7 Configure your Digital Module on an EtherNet/IP Network
How to Use This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Set Up the Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Select a Requested Packet Interval (RPI) . . . . . . . . . . . . . . . . . . . . . . . 82 Select a Communication Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Choose Direct or Rack-optimized Connection . . . . . . . . . . . . . . . 84 Ownership . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Select a Remote Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Page 5
Table of Contents v
Add Distributed I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Add a Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Download the Program to the Controller. . . . . . . . . . . . . . . . . . . . . . . 89 Access Distributed I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 General Information About IP Addresses . . . . . . . . . . . . . . . . . . . . . . 93 Determining Required Network Parameters . . . . . . . . . . . . . . . . . 93 Assigning Network Parameters via the BOOTP/DHCP Utility. . . . . 94 Using RSLinx software to set the IP address . . . . . . . . . . . . . . . . . 98 Using RSLogix 5000 software to set the IP address . . . . . . . . . . . 99 Using DHCP software to set the IP address . . . . . . . . . . . . . . . . 100 Duplicate IP Address Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Duplicate detection scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 IP Address Swapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Appendix A Interpret the Indicators
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 About the Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 1794-IB16D Diagnostic Functional Details . . . . . . . . . . . . . . . . . . . . 104 Diagnostic Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Diagnostic Functions for the 1794-IB16D. . . . . . . . . . . . . . . . . . 105 1794-OB16D Diagnostic Functional Details . . . . . . . . . . . . . . . . . . . 107 Diagnostic Functions for the 1794-OB16D. . . . . . . . . . . . . . . . . 108
Appendix B Simplified Schematics of FLEX I/O Find Your Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 1794-IA8 120V AC 8 Input Module. . . . . . . . . . . . . . . . . . . . . . . 110 Digital Modules
1794-IA8I 120V AC 8 Input Module . . . . . . . . . . . . . . . . . . . . . . 110 1794-IA16 120V AC 16 Input Module. . . . . . . . . . . . . . . . . . . . . 111 1794-OA8 120V AC 8 Output Module . . . . . . . . . . . . . . . . . . . . 111 1794-OA8I 120V AC 8 Output Module . . . . . . . . . . . . . . . . . . . 112 1794-OA16 120V AC 16 Output Module . . . . . . . . . . . . . . . . . . 112 1794-IM 8 220V AC 8 Input Module . . . . . . . . . . . . . . . . . . . . . . 113 1794-OM8 220V AC 8 Output Module . . . . . . . . . . . . . . . . . . . . 113 1794-IB8 24V DC 8 Input Module. . . . . . . . . . . . . . . . . . . . . . . . 114 1794-IB16 24V DC 16 Input Module. . . . . . . . . . . . . . . . . . . . . . 114 1794-IB16D 24V DC 16 Diagnostic Input Module. . . . . . . . . . . 115 1794-IB32 24V DC 32 Input Module. . . . . . . . . . . . . . . . . . . . . . 116 1794-IB10XOB6 24V DC 8 10 Input/6 2A Output Module . . . 117 1794-IB16XOB16P 24V DC 16 Input/16 Output Module . . . . 118 1794-IV16 24V DC 16 Source Input Module . . . . . . . . . . . . . . . 119 1794-OB8 24V DC 8 Output Module . . . . . . . . . . . . . . . . . . . . . 119 1794-OB8EP 24V DC Electronically Protected 8 Output Module . 120 1794-OB16 24V DC 16 Output Module . . . . . . . . . . . . . . . . . . . 120 1794-OB16D 24V DC 16 Diagnostic Output Module . . . . . . . . 121 Publication 1794-UM065B-EN-E - July 2006
Page 6
Table of Contents vi
Index
Publication 1794-UM065B-EN-E - July 2006
1794-OB16P 24V DC 16 Output Module . . . . . . . . . . . . . . . . . . 121 1794-OB32P 24V DC 32 Output Module . . . . . . . . . . . . . . . . . . 122 1794-OV16 24V DC 16 Sink Output Module . . . . . . . . . . . . . . . 123 1794-OV16P 24V DC 16 Sink Output Module . . . . . . . . . . . . . . 123 1794-IC 48V DC 16 Input Module. . . . . . . . . . . . . . . . . . . . . . . . 124 1794-OC 48V DC 16 Output Module . . . . . . . . . . . . . . . . . . . . . 124 1794-OW8 Relay Output Module. . . . . . . . . . . . . . . . . . . . . . . . . 124
Page 7
Preface
Purpose of This Manual
Important Warnings and Cautions
This manual provides information on installation, setting, and reading your diagnostics on the 1794-IB16D and the 1794-OB16D Diagnostic modules.
For information on
See Chapter
1794 Diagnostic Modules
1
Specific Diagnostic Module
2 or 3
Using Diagnostic Modules in a Remote I/O System
4
Using Diagnostic Modules in a DeviceNet System
5
Using Diagnostic Modules in a ControlNet System
6
Using Diagnostic Modules in an EtherNet /IP System
7
Using the Indicators for Troubleshooting
Appendix A
Simplified Schematics for all 1794 Digital Modules
Appendix B
Obey the following warnings and cautions when installing or using these modules.
ATTENTION
Environment and Enclosure This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC publication 60664-1), at altitudes up to 2000 meters without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR Publication 11. Without appropriate precautions, there may be potential difficulties ensuring electromagnetic compatibility in other environments due to conducted as well as radiated disturbance. This equipment is supplied as open-type equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications. See NEMA Standards publication 250 and IEC publication 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosure. Also, see the appropriate sections in this publication, as well as Industrial Automation Wiring and Grounding Guidelines, Allen-Bradley publication 1770-4.1, for additional installation requirements pertaining to this equipment.
5
Publication 1794-UM065B-EN-E - July 2006
Page 8
6
Preface
WARNING
When you insert or remove the module while backplane power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding.
ATTENTION
FLEX I/O is grounded through the DIN rail to chassis ground. Use zinc plated yellow-chromate steel DIN rail to assure proper grounding. The use of other DIN rail materials (such as aluminum or plastic) that can corrode, oxidize, or are poor conductors, can result in improper or intermittent grounding.
ATTENTION
Prevent Electrostatic Discharge This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: • Touch a grounded object to discharge potential static. • Wear an approved grounding wriststrap. • Do not touch connectors or pins on component boards. • Do not touch circuit components inside the equipment. • If available, use a static-safe workstation.
ATTENTION
Publication 1794-UM065B-EN-E - July 2006
During mounting of all devices, be sure that all debris (such as metal chips or wire strands) is kept from falling into the module. Debris that falls into the module could cause damage on power up.
Page 9
Preface
7
North American Hazardous Location Approval The 1794-IB16D and 1794-OB16D diagnostic modules are North American Hazardous Location approved. The following information applies when operating this equipment in hazardous locations: Products marked “CL I, DIV 2, GP A, B, C, D” are suitable for use in Class I Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code. When combining products within a system, the most adverse temperature code (lowest “T” number) may be used to help determine the overall temperature code of the system. Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation. EXPLOSION HAZARD WARNING •Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. •Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. •Substitution of components may impair suitability for Class I, Division 2. •If this product contains batteries, they must only be changed in an area known to be nonhazardous.
Informations sur l’utilisation de cet équipement en environnements dangereux : Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu’à une utilisation en environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non dangereux. Chaque produit est livré avec des marquages sur sa plaque d’identification qui indiquent le code de température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de température le plus défavorable (code de température le plus faible) peut être utilisé pour déterminer le code de température global du système. Les combinaisons d’équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l’installation. RISQUE D’EXPLOSION AVERTISSEMENT •Couper le courant ou s’assurer que l’environnement est classé non dangereux avant de débrancher l'équipement. •Couper le courant ou s'assurer que l’environnement est classé non dangereux avant de débrancher les connecteurs. Fixer tous les connecteurs externes reliés à cet équipement à l'aide de vis, loquets coulissants, connecteurs filetés ou autres moyens fournis avec ce produit. •La substitution de composants peut rendre cet équipement inadapté à une utilisation en environnement de Classe I, Division 2. •S’assurer que l’environnement est classé non dangereux avant de changer les piles.
Publication 1794-UM065B-EN-E - July 2006
Page 10
8
Preface
Related Products and Documentation Catalog Number
For additional information on FLEX I/O systems and modules, refer to the following documents: Voltage
Description
Publications Installation Instructions
1794 1794–ACN
24V dc
1794-AENT
1794 FLEX I/O Selection Guide
1794–SG002
ControlNet Adapter
1794–IN101
EtherNet/IP Adapter
1794-IN082
User Manual
ENET-UM001
1794–ACNR
24V dc
Redundant Media ControlNet Adapter
1794–IN101
1794–ACN15
24V dc
ControlNet Adapter
1794-IN101
1794–ACNR15
24V dc
Redundant Media ControlNet Adapter
1794–ADN
24V dc
DeviceNet Adapter
1794-IN099
1794–6.5.5
1794–ASB/E
24V dc
Remote I/O Adapter
1794–IN098
1794–UM009
1794–ASB2/D
24V dc
2–Slot Remote I/O Adapter
1794–APB
24V dc
Profibus Adapter
1794-IN087
1794–IB8
24V dc
8 Sink Input Module
1794-IN093
1794–IB16
24V dc
16 Sink Input Module
1794–IB32
24V dc
32 Sink Input Module
1794–IV16
24V dc
16 Source Input Module
1794–OV16
24V dc
16 Sink Output Module
1794–OV16P
24V dc
16 Protected Sink Output Module
1794–OB8
24V dc
8 Source Output Module
1794–OB8EP
24V dc
8 Electronically Fused Output Module
1794–OB16
24V dc
16 Source Output Module
1794–OB16P
24V dc
16 Protected Source Output Module
1794–OB32P
24V dc
32 Protected Source Output Module
1794–IB10XOB6
24V dc
10 Input/6 Output Module
1794–IB16XOB16P 24V dc
16 Input/16 Output Module
1794–OW8
24V dc
8 Relay Output Module
1794-IN019
1794–IE8
24V dc
Analog 8 Input Module
1794-IN100
1794–6.5.2
1794–OE4
24V dc
Analog 4 Output Module
1794–IE4XOE2
24V dc
4 Input/2 Output Analog Module
1794–OF4I
24V dc
4 Output Isolated Analog Module
1794-IN037
1794–6.5.8
1794–IF4I
24V dc
4 Input Isolated Analog Module
1794-IN038
1794–IF2XOF2I
24V dc
2 Input/2 Output Isolated Analog Module
1794-IN039
Publication 1794-UM065B-EN-E - July 2006
CNET-UM001 CNET-UM001
1794–UM059 1794–UM057
1794-IN095
1794-IN094
1794-IN083