The text of a manual · part 12 of 14
FLEX I/O Diagnostic Modules, Catalog Numbers 1794-IB16D, 1794-OB16D, User Manual, pages 111 to 120
Pages 111 to 120 of 132
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 1794-OB16
Page 111
Appendix
B
Simplified Schematics of FLEX I/O Digital Modules
Find Your Module Voltage category:
Catalog number:
Input/ output:
I/O points:
Module description:
See page:
1794-IA8
Input
8
120V ac 8 input module
110
AC modules 120V ac
1794-IA8I 1794-IA16 1794-OA8
Output
120V ac 8 isolated input module
110
16
120V ac 16 input module
111
8
120V ac 8 output module
111
120V ac 8 isolated output module
112
16
120V ac 16 output module
112
8
220V ac 8 input module
113
220V ac 8 output module
113
1794-OA8I 1794-OA16 220V ac
1794-IM8
Input
1794-OM8
Output
1794-IB8
Input
8
24V dc 8 sink input module
114
1794-IB16
Input
16
24V dc 16 sink input module
114
1794-IB16D
Input
16
24V dc 16 sink diagnostic input module
115
1794-IB32
Input
32
24V dc 32 sink input module
116
1794-IV16
Input
16
24V dc 16 source input module
119
1794-IB10XOB6
Input/output
10 in/6 out
24V dc 10 input/6 2A output combo module
117
1794-IB16XOB16P
Input/output
16 in/16 out
24V dc combo module, 16 sink inputs, 16 source outputs, protected
118
1794-OB8
Output
8
24V dc 8 source output module
119
24V dc electronically fused 8 2 A output module
120
24V dc 16 source output module
120
1794-OB16D
24V dc 16 source diagnostic output module
121
1794-OB16P
24V dc 16 protected source output module
121
DC modules 24V dc
1794-OB8EP 1794-OB16
16
1794-OB32P
32
24V dc 32 protected source output module
122
1794-OV16
16
24V dc 16 sink output module
123
24V dc 16 protected sink output module
123
48V dc 16 sink input module
124
48V dc 16 source output module
124
24V dc 8 relay output module
124
1794-OV16P 48V dc
24V dc
109
1794-IC16
Input
1794-OC16
Output
1794-OW8
Output
8
Publication 1794-UM061A-EN-P - July 2006
Page 112
110
Simplified Schematics of FLEX I/O Digital Modules
1794-IA8 120V AC 8 Input Module Typical Simplified Schematic for Input 0 and a 1794-TB2, 1794-TB3, 1794-TB3S, or (1794-TBN) Terminal Base
L1
C-34 A-1 (C-1)
Flexbus Interface
Input Filter
Input Device
Opto Isolation
A-0 (B-0) 85…132V ac
B-16 Common L2
30231
1794-IA8I 120V AC 8 Input Module Typical Simplified Schematic for Input 0 and a 1794-TB3, 1794-TB3S, 1794-TB2, or (1794-TBN) Terminal Base
Flexbus Interface
Input Filter
Opto Isolation
A-0
Input (B-0) Device
L1 85…132V ac
A-1 (C-1) Note: To maintain isolation, separate ac sources must be used with each channel. Auxiliary terminal strips are required for all terminal base units.
Publication 1794-UM061A-EN-P - July 2006
Common L2
40945
Page 113
Simplified Schematics of FLEX I/O Digital Modules
111
1794-IA16 120V AC 16 Input Module Typical Simplified Schematic for Input 0 and a 1794-TB3 or 1794-TB3S Terminal Bases
C-34
L1
C-35
Flexbus Interface
Input Filter
A-0
Opto Isolation
Input Device 85…132V ac
B-16 Common L2
40945
Typical Simplified Schematic for Input 0 and a 1794-TBN Terminal Base
Flexbus Interface
Input Filter
Opto Isolation
L1
B-0 Input Device
85…132V ac
B-16 Common L2
30231
Note: Auxiliary terminal strips are required when using the 1794-TBN with the 1794-IA16 module.
1794-OA8 120V AC 8 Output Module Typical Simplified Schematic for Output 0 and a 1794-TB2, 1794-TB3, 1794-TB3S, or (1794-TBN, 1794-TBNF) Terminal Base
C-34
L1
85…132V ac Flexbus Interface
Opto Isolation
*
A-0 (B-0) Output Device A-1 (C-1)
*Fuse on 1794-TBNF only
B-16
Common L2 40105
Publication 1794-UM061A-EN-P - July 2006
Page 114
112
Simplified Schematics of FLEX I/O Digital Modules
1794-OA8I 120V AC 8 Output Module Typical Simplified Schematic for Output 0 and a 1794-TB3, 1794-TB3S, or (1794-TBN, 1794-TBNF) Terminal Base
Flexbus Interface
L1
A-1 (C-1)
85…132V ac
*
A-0
Output (B-0) Device L2
Opto Isolation
40944C
B-
* Fuse on 1794-TBNF only Note: To maintain isolation, separate ac sources must be used with each channel. Auxiliary terminal strips are required for all terminal base units.
1794-OA16 120V AC 16 Output Module Typical Simplified Schematic for Output 0 and a 1794-TB2, 1794-TB3, or 1794-TB3S Terminal Base
Flexbus Interface
Opto Isolation
L1
C-34
85…132V ac
A-0 Output Device B-17 B-16 L2
Typical Simplified Schematic for Output 0 and a 1794-TBN Terminal Base
C-34
40944B
L1 85…132V ac
Flexbus Interface
B-0 Opto Isolation
Output Device
L2
Note: Auxiliary terminal strips are required when using the 1794-TBN with the 1794-OA16 module. 40944A
Publication 1794-UM061A-EN-P - July 2006
Page 115
Simplified Schematics of FLEX I/O Digital Modules
113
1794-IM 8 220V AC 8 Input Module Typical Simplified Schematic for Input 0 and a 1794-TBN Terminal Base
L1
C-34 C-1
Flexbus Interface
Input Filter
B-0 Input Device
Opto Isolation
170…264V ac
B-16 L2
41697
1794-OM8 220V AC 8 Output Module
Typical Simplified Schematic for Output 0 and 1794-TBN or 1794-TBNF Terminal Base
Flexbus Interface
L1
C-34
Opto Isolation
*
B-0
170…264V ac Output Device
C-1
* Fuse on 1794-TBNF only
B-16 L2 41701
Publication 1794-UM061A-EN-P - July 2006
Page 116
114
Simplified Schematics of FLEX I/O Digital Modules
1794-IB8 24V DC 8 Input Module Typical Simplified Schematic for Input 0 and a 1794-TB3 or 1794-TB3S Terminal Base Opto Isolation
A-0 Input Device + 24V COM
Flexbus Interface
C-35 C-34 B-16
40107
1794-IB16 24V DC 16 Input Module
Typical Simplified Schematic for Input 0 and a 1794-TB3 or 1794-TB3S Terminal Base
Input Device A-0 C-35 + 24V
Opto Isolation
Flexbus Interface
C-34 B-16
COM
40107
Publication 1794-UM061A-EN-P - July 2006
Page 117
Simplified Schematics of FLEX I/O Digital Modules
115
1794-IB16D 24V DC 16 Diagnostic Input Module Typical Simplified Schematic for Input 0 and a 1794-TB32, 1794-TB32S Terminal Base
User Power
24V dc C-43
+
Reverse Voltage Monitor
PTC
Reverse
Shorted Input Monitor
Short V+
B-17 Sensor Power
Open Wire Monitor
Fault Indicator
Input Device *
Open
Flexbus Interface
C-36
Input
Input A-0 Input Circuit Indicator a 20 KΩ dummy resistor on unused input channels and on inputs that have * Use hard-contact input devices. The dummy resistors can be placed between sensor power and the input channel, or between sensor power and common.
Publication 1794-UM061A-EN-P - July 2006
Page 118
116
Simplified Schematics of FLEX I/O Digital Modules
1794-IB32 24V DC 32 Input Module
Typical Simplified Schematic for Input 0 and Input 16 and a 1794-TB32, or 1794-TB32S Terminal Base
A-0 Input Device + V 1 24V COM 1
+ V 2 24V COM 2
Flexbus Interface
C-37 C-35 C-36
B-17 Input Device
Opto Isolation
C-45
Opto Isolation Flexbus Interface
C-43 C-44
0107
Publication 1794-UM061A-EN-P - July 2006
Page 119
Simplified Schematics of FLEX I/O Digital Modules
117
1794-IB10XOB6 24V DC 8 10 Input/6 2A Output Module
Typical Simplified Schematic for Input 0 and a 1794-TB3 or 1794-TB3S Terminal Base Opto Isolation
A-0 Input Device
Flexbus Interface
C-35
+ 24V
C-34
-
B-16
40123
Typical Simplified Schematic for Output 0 and a 1794-TB3 or 1794-TB3S Terminal Base C-34 +24V +
VCC
24V
Opto Isolation -
Flexbus Interface
A-10 OUT
COM
Output Device B-27 B-16 40124
Publication 1794-UM061A-EN-P - July 2006
Page 120
118
Simplified Schematics of FLEX I/O Digital Modules
1794-IB16XOB16P 24V DC 16 Input/16 Output Module
Typical Simplified Schematic for Input 0 and Output 16 and a 1794-TB32 or 1794-TB32S Terminal Base Opto Isolation
A-0 Input Device + V 1 24V -
Flexbus Interface
C-37 C-35 C-36 COM 1
C-43
VCC
+24V
+ 24V -
Current Limit Circuit Thermal Protection Output FET
B-17
ASIC
Output Device COM 2
C-46 C-44
Publication 1794-UM061A-EN-P - July 2006
V2