For the Allen-Bradley 1794-IB16 and Allen-Bradley 1794-IH16

Page 1

Section

1.1

About the FLEX I/O and FLEX Ex I/O Systems

1794 FLEX I/O Overview

FLEX I/O offers:

Adapter

Terminal base FlexBus connectors

I/O module Keyswitch

FlexBus connectors

22

++

Network Connector

24V DC field power

Terminal strips

FLEX I/O is a Distributed I/O System that connects to several Networks including EtherNet/IP, ControlNet and DeviceNet. Flexible, low-cost, modular I/O for distributed applications. FLEX I/O offers all the functions of larger, rack-based I/O without the space requirements. Independently select the I/O, termination style, and network to meet your application needs. Two separate connection terminals for field power let you daisy-chain power connections to adjacent terminal bases. One adapter communicates with up to eight I/O modules. Allows connection to: • 256 digital input/output points, or • 96 analog input/output points, or • mix of I/O to meet your needs. Modularity of FLEX I/O system provides choice of network and ease of expansion. The wiring terminations are done almost entirely on the terminal base. Terminal base termination selection includes screw-clamp, spring-clamp, and cage-clamp to wire directly to 2-, 3-, or 4-wire devices. Additional options of D-shell, knife disconnect, and fused terminal bases are available. Adjustable keyswitch prevents incorrect module insertion into a preconfigured terminal base. 1

Publication 1794-SG002D-EN-P - May 2012

Page 2

2

About the FLEX I/O and FLEX Ex I/O Systems

Terminal bases can be exchanged without moving other bases in your system. If desired, connect individual power supplies to each base to isolate modules. Plug the I/O module into the terminal base to connect the I/O bus and field devices. Remove and insert modules under power. No direct wiring to the module enables you to change modules without disturbing field wiring or system power. Mix and match I/O modules. There is a wide variety of digital, analog, and specialty modules. Each FLEX I/O system contains at least one adapter, one terminal base, and one I/O module. You can power the system with a FLEX power supply (1794-PS13 or -PS3), a 1606 switched mode power supply, or any other compatible power source. Use the terminal block on the terminal base to wire your field devices directly. Wiring directly saves you: • installation and testing time • multiple, long wiring runs and external terminal blocks • control cabinet panel space FLEX I/O provides additional savings if system problems develop. Combining your field-wiring terminations and the I/O interface into the same location saves you time and money by making your system easier to maintain and troubleshoot. Additionally, the full-featured FLEX I/O system lets you, in non-hazardous location, remove and insert modules under backplane power without disrupting your system. Your FLEX I/O system can communicate on EtherNet/IP, ControlNet, DeviceNet, and many other open networks including, but not limited, to Remote I/O and PROFIBUS DP. Adapters and other components are available for adding to your system as your specific application requirements change.

Publication 1794-SG002D-EN-P - May 2012

Page 3

About the FLEX I/O and FLEX Ex I/O Systems

1794 FLEX I/O XT Overview

3

FLEX I/O XT modules are designated for extreme environment use. They differ from their non XT counterparts only in operational temperature ranges and conformal coating is standard for FLEX I/O XT products. FLEX I/O XT modules meet or exceed the following standards: • ANSI / ISA-S71.04-1985; Class G1, G2 and G3 Environments • CEI IEC 6065A-4; Class 1 and 2 Environments • UL 746E • MIL-1-46058C to ASTM-G21; (Tropicalization and fungicide) These standards specify common emissions and classify their concentration levels in a number of industrial processes. Just a few of the common reactive agents that the FLEX I/O XT modules protect against are: • H2S – Hydrogen sulfide • SO2, SO3 – Sulfur dioxide • CnHn – Hydrocarbons • NOx – Oxides of nitrogen • CI2 – Wet Chlorine / Dry Chlorine • NH3 – Ammonia

General FLEX I/O and FLEX I/O XT Specifications

The following table shows the similarities and differences between the FLEX I/O and the FLEX I/O XT specifications. Specifications Comparison Attribute(1)

1794 FLEX I/O

1794 FLEX I/O XT

Temperature, operating

0…55 °C (32…131 °F)

-20...70 ºC (-4....185 ºF)

Temperature, nonoperating

-40…85 °C (-40…185 °F)

-40...85 ºC (-40...185 ºF)

Relative humidity

5…95% non-condensing

Shock, operating(2)

30 g peak acceleration, 11(±1) ms pulse width

Shock, nonoperating(1)

50 g peak acceleration, 11(±1) ms pulse width

Vibration

Tested 5 g @ 10…500 Hz per IEC 68-2-6

Wire size

0.34mm2…2.5 mm2 (22…12 AWG) stranded copper wire rated at 75 °C or higher 1.2 mm (3/64 in.) insulation max

Atmospheric protection non conformal coated conformal coated to meet or exceed the following standards: • ANSI / ISA-S71.04-1985; Class G1, G2 and G3 Environments • CEI IEC 6065A-4; Class 1 and 2 Environments • UL 746E • MIL-1-46058C to ASTM-G21; (Tropicalization and fungicide)

Publication 1794-SG002D-EN-P - May 2012

Page 4

4

About the FLEX I/O and FLEX Ex I/O Systems

Specifications Comparison Attribute(1)

1794 FLEX I/O

Certifications (when product is marked)(3)

• UL Listed Industrial Control Equipment

1794 FLEX I/O XT

• UL Listed for Class I, Division 2 Groups A, B, C, D Hazardous Locations • CE Marked for all applicable directives • CE / ATEX • CSA Certified Process Control Equipment for Class I, Division 2 Group A, B, C, D Hazardous Locations • C-Tick Marked for all applicable acts • KCC • Marine Certification • SIL 2 Certification • ODVA • ControlNet (1) For all other product-specific specifications, including environmental and certification, see the product sections within this Selection Guide. (2) To maintain these specifications, you must use DIN rail locks. (3) See the Product Certification link at www.ab.com for Declarations of Conformity, Certificates, and other certification details.

Publication 1794-SG002D-EN-P - May 2012

Page 5

About the FLEX I/O and FLEX Ex I/O Systems

Specify a FLEX I/O or FLEX I/O XT System

5

Follow these steps as you specify your FLEX I/O or FLEX I/O XT system:

✓

Step

See

Page

1 Select a communication adapter Choose the network for your operating system.

CIP Network Infrastructure

7

Select a Network

8

• location of the device

Digital I/O Modules

15

• your application

FLEX I/O Analog, Thermocouple and RTD Modules

35

FLEX I/O Counter Modules

58

2 Select I/O modules based on field device

• number of points needed • number of points available per module • number of modules Or use the Integrated Architecture Builder tool at http://www.rockwellautomation.com/en/e-tools/confi guration.html 3 Select a terminal base Choose an appropriate terminal base for your modules. General Specification Comparison

65

4 Choose appropriate power supplies

• Choose appropriate power supply

Power Supply Definitions

67

• Ensure sufficient power for the communication Power Requirements and Transformer 68 Sizing adapter and modules 5 Determine mounting requirements and select accessories

• Determine whether to panel mount or DIN rail panel mount or DIN rail mount mount the FLEX I/O system and at what orientation (horizontal or vertical)

113

• Choose appropriate optional accessories to enhance your system

1794-CE1 and 1794-CE3 Extender Cables

115

1794-NM1 FLEX I/O Mounting Kit

115

1492-EA35 DIN Rail Locks

116

1794-LBL FLEX I/O Label Kit

116

Publication 1794-SG002D-EN-P - May 2012

Page 6

Section

1.2

Select FLEX I/O Communication Adapters

Step 1 – Select:

a communication adapter based on the appropriate network A FLEX I/O adapter module interfaces FLEX I/O modules to an I/O scanner port across a communication network. The FLEX I/O adapter module contains a built-in power supply that converts 24V DC to 5V DC for the backplane to power the FLEX I/O modules. • Your 1794 FLEX I/O system can communicate on: • EtherNet/IP • ControlNet, single media or redundant • DeviceNet • Many other open networks including, Remote I/O, PROFIBUS DP, and others from Encompass partners

CIP Network Infrastructure

The Common Industrial Protocol (CIP) allows complete integration of control with information, multiple CIP networks and standard Internet technologies. CIP provides manufacturers with a scalable and coherent architecture incorporating discrete, process, safety, synchronization and motion applications using the same network technology as the ERP, MES enterprise levels applications. Ultimately, network convergence helps align technology with business goals for business process transformation and enterprise-wide visibility. The following networks share the Common Industrial Protocol at their upper levels, while remaining media independent at their lower levels. This allows manufacturers to specify the best network for their application and eliminate costly and complex gateways when connecting dissimilar upper level networks. • EtherNet/IP is an open industrial networking standard that supports implicit and explicit messaging and uses commercial, off-the-shelf Ethernet equipment and physical media. • ControlNet allows intelligent, high-speed control devices to share the information required for supervisory control, work-cell coordination, operator interface, remote device configuration, programming, and troubleshooting. • DeviceNet offers high-speed access to plant-floor data from a broad range of plant floor devices and a significant reduction in wiring.

7

Publication 1794-SG002D-EN-P - May 2012

Page 7

8

Select FLEX I/O Communication Adapters

Select a Network

You can configure your system for information exchange between a range of field devices and a specific scanner. You select the communication adapters for the networks that meet your needs:

Network Comparison by Application Requirement Application Requirements

Network(1)

Communication Adapter

• Plant management (material handling)

EtherNet/IP

1794-AENT 1794-AENTR 1794-AENTRXT

ControlNet

1794-ACN15 1794-ACN15K(2) 1794-ACNR15(3) 1794-ACNR15XT(4)

DeviceNet

1794-ADN 1794-ADNK

• Connections to Remote I/O networks

Remote I/O

1794-ASB 1794-ASB2

• Connection to PROFIBUS DP and DPV1 networks

PROFIBUS DP PROFIBUS DPV1

1794-APB 1794-APBDPV1

• Configuration, data collection, and control on a single, high-speed network • Time-critical applications with no established schedule • Data sent regularly • Internet/Intranet connection • Built-in switch, or high availability requirement (2-port AENTR) • High-speed transfer of time-critical data between controllers and I/O devices • Deterministic and repeatable data delivery • Media redundancy • Connections of low-level devices to plant floor controllers • More diagnostics for improved data collection and fault detection • Less wiring and reduced start-up time than a traditional, hard-wired system

(1) Communication adapters and other components are available for adding to your system as your specific application requirements change. For more information, go to www.rockwellautomation.com/encompass and search for products under the FLEX I/O platform. (2) Modules that have the letter K in the last position of the catalog number, before the series designation, refer to conformal coated versions of the standard modules. These modules meet the following certifications: ANSI / ISA-S71.04-1985, Class G1, G2, and G3 environments; CEI IEC 6065A-4 Class 1 and 2 environments; UL 746E (3) Modules that have the letter R in the catalog number, before the series designation, refer to redundancy versions of the standard modules and are meant for redundancy networks. (4) Modules that have the letters XT in the catalog number, before the series designation, refer to extended temperatures version of the standard modules.

EtherNet/IP Network EtherNet/IP is a network suitable for use in industrial environment and time-critical applications. EtherNet/IP uses standard Ethernet and TCP/IP technologies and an open application layer protocol called the Control and Information Protocol (CIP). CIP is also the application layer used in DeviceNet and ControlNet networks. The open Application Layer protocol makes interoperability and interchangeability of industrial automation and control devices on EtherNet/IP a reality for automation and control applications. The 1794-AENT and 1794-AENTR connect FLEX I/O to Ethernet/IP enabled controllers such as ControlLogix or CompactLogix.

Publication 1794-SG002D-EN-P - May 2012

Page 8

Section

1.3

Select FLEX I/O Modules

Step 2 – Select:

I/O modules The FLEX I/O module plugs into the terminal base, connecting to the I/O bus and field devices. Since there is no direct wiring to the I/O module, you can remove and insert modules under backplane power, enabling you to change modules without disturbing field wiring, other I/O modules, or FLEX backplane power. This eliminates costly downtime and the inefficiencies of restarting a system. The choices and flexibility you have with I/O types range from digital and analog to temperature and motion control. FLEX I/O allows you to use as many as eight terminal bases per adapter which can provide a maximum of 256 digital I/O points or 96 analog channels per adapter. You can mix and match digital and analog I/O with mounting and wiring options, supplying you with a successful distributed system solution. This flexibility gives you the following choices of I/O signal types: • Digital: AC and DC voltage signals • Analog: current or voltage • Relay: normally open, 2 A capability • Protected outputs: non-latching, latching, and with diagnostics • Temperature: thermocouple or RTD • Motion: high-speed counters, flow metering, and totalization • Combo modules: combination of input and output capability • Harsh environments: use FLEX I/O XT in harsh environments • Intrinsic Safety (IS): use FLEX Ex I/O in hazardous areas to connect to field devices

Digital I/O Modules

Digital I/O modules interface with field devices such as: • pushbutton and limit switches • on/off actuators such as motor starters, pilot lights, and annunciators • relay contacts

Features Modules are available in different densities ranging from 8 to 32 points. • Digital I/O modules cover a wide electrical range: 15

Publication 1794-SG002D-EN-P - May 2012

Page 9

16

Select FLEX I/O Modules

• •

•

•

• •

120V AC: Input/Output and Isolated Input/Output, 8 and 16 point 220V AC: Input/Output, 8 point 24V DC: Input/Output/Combination, Sink/Source, Protected, Electronically Fused, Diagnostic, 8, 16, and 32 point 48V DC: Sink Input/Source Output, 16 point Relay: Sink/Source, 8 point Isolated inputs and outputs can be used in applications such as motor control centers where individual control transformers are used. Protected outputs (P) have electronic protection which acts to shut the output down in reaction to a short circuit, overload, or over-temperature condition. Recovery from shutdown is automatic upon removal of the output fault. No fault status is provided to the processor. Electronic Fused (EP) module acts to open the output when a fault occurs. The fuse can be reset by operating a pushbutton, via software, or by cycling the input power. Fault status is provided to the processor. Diagnostic (D) modules detect, indicate, and report to the processor the following faults: open input or output field devices or wiring shorted output field devices shorted input or output wiring reverse polarity of user supply wiring Selectable input filter times from <1 to 60 ms. LED for each channel indicating status of: corresponding input device output signal

Digital I/O Module Summary Catalog Number

Inputs

Outputs

Terminal Base Unit

Electrical Range

Module Type

8, 1794-TBN, 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TBKD, 1794-TB3K, 1794-TB3SK, 1794-TBNK

120V AC

Nonisolated inputs

AC Modules 1794-IA8 1794-IA8I 1794-IA16

16

1794-IM8

8

1794-IM16

16

1794-OA8, Isolated inputs

1794-TB3, 1794-TB3S, 1794-TBN(1), 1794-TB3K, 1794-TB3SK, 1794-TBNK

Nonisolated inputs, 1794-TBN, 1794-TBNK

240V AC

8

1794-TBNF, 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TBN, 1794-TBKD, 1794-TBNFK, 1794-TB3K, 1794-TB3SK, 1794-TBNK

120V AC

1794-OA8I

Isolated outputs

1794-OA16

16

1794-TB3, 1794-TB2, 1794-TB3S,1794-TB3K 1794-TB3SK, 1794-TBN(1), 1794-TBKD, 1794-TBNK

120V AC

1794-OM8

8

240V AC

1794-OM16

16

1794-TBNF, 1794-TBN, 1794-TBNFK, 1794-TBNK

Publication 1794-SG002D-EN-P - May 2012

Nonisolated inputs

Nonisolated outputs