Manual · Allen-Bradley
Resistive Brake Module Installation Instructions
Manual24 pagesPDF 693 KB
Installation instructions for Allen-Bradley Bulletin 2090 resistive brake modules 2090-XB33-16, -XB33-32 and 2090-XB120-01, -03, -06.
Covers · 1 model
The models it covers
Summary
What is in it
Installation instructions for the Allen-Bradley Bulletin 2090 Resistive Brake Module (RBM), catalog numbers 2090-XB33-16, 2090-XB33-32, 2090-XB120-01, 2090-XB120-03 and 2090-XB120-06. It explains what the RBM does, mounting requirements and noise zones, dimensions and clearances, panel installation, the RBM connectors, wiring to a drive system with the power cable shield clamp, troubleshooting by status LED, specifications including the safety contactor, and accessory equipment.
Its parts
- Unpacking Your Resistive Brake Module
- Important User Information
- Understanding Your Resistive Brake Module
- Dimensions and Clearance Requirements
- Installing Your Resistive Brake Module
- Understanding RBM Connectors
- Wiring the RBM to a Drive System
- Troubleshooting
- Specifications
- Accessory Equipment
- Related Documentation
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Installation instructions for the Allen-Bradley Bulletin 2090 Resistive Brake Module (RBM), covering the 2090-XB33-16, 2090-XB33-32, 2090-XB120-01, 2090-XB120-03 and 2090-XB120-06. They explain mounting the module on a panel, wiring it between a servo drive and its motor, and troubleshooting it from its status LEDs, with specifications and accessory part numbers.
- What it is
- Resistive brake module: a contactor cuts the motor from the drive and resistors brake the motor p. 3
- Braking duty
- Brakes a motor once per minute at a 15:1 inertia mismatch p. 3
- Drive power
- 230/460V power in from the drive (TB1) and out to the motor (TB2) p. 13
- Resistance
- 2090-XB33-16: 16 ohms per phase p. 19
- Coil and I/O supply
- External 24V (22.4 - 26.4), 0.5A power supply p. 13
- Control terminals
- 24V across COIL_A1 and COIL_A2 engages the contactor; CONSTAT_41/42 is a normally closed status output p. 17
- Connectors
- TB1 drive, TB2 motor and TB3 I/O; TB4 230VAC aux power on 2090-XB120-xx only p. 1
- Max ambient
- Enclosure ambient no higher than 50° C (122° F) p. 4
- Altitude
- To 1500 m (5000 ft) without derating; derate continuous current 3% per extra 300 m up to 3000 m p. 4
- Mounting
- Vertical within ±2°, two M6 (1/4 in. - 20) bolts at 1 Nm (9 in-lb) minimum p. 6, 8, 9
- Clearance
- 2090-XB33-xx: 50 mm (1.97 in.) for airflow; none needed left or right p. 6
- Wire strip and torque
- 2090-XB33-xx: power wire 10.0 mm strip, 0.5 - 0.6 Nm; I/O wire 6.0 mm strip, 0.22 - 0.25 Nm p. 14, 15
- Drive cables
- Kinetix 6000: 2090-XXNRB-14F0P7 (14 AWG, 66cm); Ultra: 2090-XXNRB-14F1P3 (14 AWG, 132cm) p. 23
- Connector kits
- 2090-XNRBM-1 (33A, TB1, TB2, TB3); 2090-XNRBM-2 (106A, TB1 to TB4) p. 23
What this manual walks you through
- Planning the panel, enclosure and environment for the module p. 4
- Routing RBM wiring in the dirty noise zone p. 5
- Mounting the module to the panel p. 8, 9
- Identifying the connectors and status LEDs p. 9, 10
- Wiring the I/O, power and 230VAC auxiliary cables p. 14, 15
- Applying the power cable shield clamp p. 16
- Troubleshooting with the 24 VDC status LED p. 17
- Troubleshooting with the 230 VAC status LED on 2090-XB120-xx units p. 18
- Troubleshooting motor faults caused by the RBM p. 19
Good to know
- To comply with UL 508C, the module must be protected upstream by a 2.5 kV overvoltage control device. p. 11
- The module has no field replaceable components. p. 1
- Allow five minutes for the power supplies to discharge before wiring. p. 14
- The module must be mounted vertically for its contactor to work properly. p. 6
- The manual states the module must sit in a grounded conductive enclosure rated IP55 to comply with UL and CE requirements. p. 4
Questions this manual answers
What does a 2090-XB33-16 resistive brake module do?
Its contactor separates the motor leads from the drive output, and its resistors brake the motor by dissipating its energy as heat. p. 3
How often can the resistive brake module stop a motor?
Once per minute, with a 15:1 inertia mismatch. p. 3
What powers the RBM contactor coil?
An external 24V supply (22.4 to 26.4V, 0.5A) applied across COIL_A1 and COIL_A2. p. 13
Why is the RBM status LED blinking green and clicking?
The contactor is rapidly engaging and disengaging; the manual points to grounding, wires near noise sources, or wrong control wiring. p. 17
Which cable connects the RBM to a Kinetix 6000 drive?
The Kinetix 6000 drive interface cable 2090-XXNRB-14F0P7 (14 AWG, 66cm), or 2090-XXNRB-aFxxPyy for 4, 8 or 10 AWG. p. 23
Contents
Chapters and sections
Each line opens the PDF at its page.
- Resistive Brake Module1
- Unpacking Your Resistive Brake Module1
- Important User Information2
- Understanding Your Resistive Brake Module3
- Dimensions and Clearance Requirements6
- Installing Your Resistive Brake Module8
- Understanding RBM Connectors9
- Wiring the RBM to a Drive System11
- Troubleshooting17
- Specifications19
- Accessory Equipment23
- Related Documentation24
The whole text · 3 parts