Page 1 of Resistive Brake Module Installation Instructions

Manual · Allen-Bradley

Resistive Brake Module Installation Instructions

Manual24 pagesPDF 693 KB

Installation instructions for Allen-Bradley Bulletin 2090 resistive brake modules 2090-XB33-16, -XB33-32 and 2090-XB120-01, -03, -06.

Download the PDF693 KB

Covers · 1 model

The models it covers

Summary

What is in it

Installation instructions for the Allen-Bradley Bulletin 2090 Resistive Brake Module (RBM), catalog numbers 2090-XB33-16, 2090-XB33-32, 2090-XB120-01, 2090-XB120-03 and 2090-XB120-06. It explains what the RBM does, mounting requirements and noise zones, dimensions and clearances, panel installation, the RBM connectors, wiring to a drive system with the power cable shield clamp, troubleshooting by status LED, specifications including the safety contactor, and accessory equipment.

Its parts

  1. Unpacking Your Resistive Brake Module
  2. Important User Information
  3. Understanding Your Resistive Brake Module
  4. Dimensions and Clearance Requirements
  5. Installing Your Resistive Brake Module
  6. Understanding RBM Connectors
  7. Wiring the RBM to a Drive System
  8. Troubleshooting
  9. Specifications
  10. Accessory Equipment
  11. Related Documentation

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Installation instructions for the Allen-Bradley Bulletin 2090 Resistive Brake Module (RBM), covering the 2090-XB33-16, 2090-XB33-32, 2090-XB120-01, 2090-XB120-03 and 2090-XB120-06. They explain mounting the module on a panel, wiring it between a servo drive and its motor, and troubleshooting it from its status LEDs, with specifications and accessory part numbers.

What it is
Resistive brake module: a contactor cuts the motor from the drive and resistors brake the motor p. 3
Braking duty
Brakes a motor once per minute at a 15:1 inertia mismatch p. 3
Drive power
230/460V power in from the drive (TB1) and out to the motor (TB2) p. 13
Resistance
2090-XB33-16: 16 ohms per phase p. 19
Coil and I/O supply
External 24V (22.4 - 26.4), 0.5A power supply p. 13
Control terminals
24V across COIL_A1 and COIL_A2 engages the contactor; CONSTAT_41/42 is a normally closed status output p. 17
Connectors
TB1 drive, TB2 motor and TB3 I/O; TB4 230VAC aux power on 2090-XB120-xx only p. 1
Max ambient
Enclosure ambient no higher than 50° C (122° F) p. 4
Altitude
To 1500 m (5000 ft) without derating; derate continuous current 3% per extra 300 m up to 3000 m p. 4
Mounting
Vertical within ±2°, two M6 (1/4 in. - 20) bolts at 1 Nm (9 in-lb) minimum p. 6, 8, 9
Clearance
2090-XB33-xx: 50 mm (1.97 in.) for airflow; none needed left or right p. 6
Wire strip and torque
2090-XB33-xx: power wire 10.0 mm strip, 0.5 - 0.6 Nm; I/O wire 6.0 mm strip, 0.22 - 0.25 Nm p. 14, 15
Drive cables
Kinetix 6000: 2090-XXNRB-14F0P7 (14 AWG, 66cm); Ultra: 2090-XXNRB-14F1P3 (14 AWG, 132cm) p. 23
Connector kits
2090-XNRBM-1 (33A, TB1, TB2, TB3); 2090-XNRBM-2 (106A, TB1 to TB4) p. 23

What this manual walks you through

  • Planning the panel, enclosure and environment for the module p. 4
  • Routing RBM wiring in the dirty noise zone p. 5
  • Mounting the module to the panel p. 8, 9
  • Identifying the connectors and status LEDs p. 9, 10
  • Wiring the I/O, power and 230VAC auxiliary cables p. 14, 15
  • Applying the power cable shield clamp p. 16
  • Troubleshooting with the 24 VDC status LED p. 17
  • Troubleshooting with the 230 VAC status LED on 2090-XB120-xx units p. 18
  • Troubleshooting motor faults caused by the RBM p. 19

Good to know

  • To comply with UL 508C, the module must be protected upstream by a 2.5 kV overvoltage control device. p. 11
  • The module has no field replaceable components. p. 1
  • Allow five minutes for the power supplies to discharge before wiring. p. 14
  • The module must be mounted vertically for its contactor to work properly. p. 6
  • The manual states the module must sit in a grounded conductive enclosure rated IP55 to comply with UL and CE requirements. p. 4

Questions this manual answers

What does a 2090-XB33-16 resistive brake module do?

Its contactor separates the motor leads from the drive output, and its resistors brake the motor by dissipating its energy as heat. p. 3

How often can the resistive brake module stop a motor?

Once per minute, with a 15:1 inertia mismatch. p. 3

What powers the RBM contactor coil?

An external 24V supply (22.4 to 26.4V, 0.5A) applied across COIL_A1 and COIL_A2. p. 13

Why is the RBM status LED blinking green and clicking?

The contactor is rapidly engaging and disengaging; the manual points to grounding, wires near noise sources, or wrong control wiring. p. 17

Which cable connects the RBM to a Kinetix 6000 drive?

The Kinetix 6000 drive interface cable 2090-XXNRB-14F0P7 (14 AWG, 66cm), or 2090-XXNRB-aFxxPyy for 4, 8 or 10 AWG. p. 23

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Resistive Brake Module1
    1. Unpacking Your Resistive Brake Module1
    2. Important User Information2
    3. Understanding Your Resistive Brake Module3
    4. Dimensions and Clearance Requirements6
    5. Installing Your Resistive Brake Module8
    6. Understanding RBM Connectors9
    7. Wiring the RBM to a Drive System11
    8. Troubleshooting17
    9. Specifications19
    10. Accessory Equipment23
    11. Related Documentation24

From the PDF’s own bookmarks.

The whole text · 3 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. Pages 9 to 169-16
  3. Pages 17 to 2417-24

The file

Revision and size

RevisionPublication 2090-IN009F-EN-P, November 2004
PublisherAllen-Bradley (Rockwell Automation)
Pages24
PDF693 KB
TextText from the PDF itself.

The first pages · 3 of 24

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 24
Page 2
Page 2of 24
Page 3
Page 3of 24