Page 17

Resistive Brake Module Installation Instructions

Troubleshooting

17

There are no field replaceable components in an RBM. If problems persist after attempting to troubleshoot the system, contact your Allen-Bradley representative for further assistance.

24 VDC Status LED The Status LED is ON when 24V is applied between COIL_A1 and COIL_A2 (e.g., a Brake Enable signal is received from a drive). Use the table below for troubleshooting the RBM using the 24 VDC Status LED. If 24 VDC Status LED is:

Steady Green

Blinking Green (audible clicking)

RBM Contactor Status is:

Potential Cause is:

Possible Resolution is:

Contactor engaged – direct connection between drive and motor

No faults or failures

N/A

Contactor disengaged – no connection between drive and motor

Contactor failure

Verify by monitoring CONSTAT_41/42 status (output is NC) Contact AB representative

Contactor rapidly engaging/disengaging

Recommended grounding not followed

• Verify grounding • Route wires away from noise sources • Refer to GMC-RM001x-EN-P

Control circuit improperly wired

Verify control wiring and programming

No faults or failures

N/A

+24V not applied between COIL_A1 and COIL_A2

• +24V supply is off • Verify wiring • Drive not enabled • Contact AB representative

T1 (Fault) thermostat open

Duty cycle: exceeded; allow RBM to cool.

Off (intended)

Off (unintended)

Contactor disengaged (connection open between drive and motor)

Publication 2090-IN009F-EN-P, November 2004

Page 18

18

Resistive Brake Module Installation Instructions

230 VAC Auxiliary Power Status LED (2090-XB120-xx RBM only) The 230 VAC Status LED is ON when 230V AC is applied to L1 and L2 (TB4) and the contactor is engaged by applying 24V DC across COIL_A1 and COIL_A2 (e.g., a Brake Enable signal is received from a drive). Use the table below for troubleshooting the RBM using the 230 VAC Status LED. ‘1 If 230 VAC Status LED is: Steady Green

Blinking Green (audible clicking)

Off (intended)

RBM Contactor Status is:

Potential Cause is:

Possible Resolution is:

Engaged

No faults or failures

N/A

Disengaged

Contactor failure

Verify by monitoring CONSTAT_41/42 Contact AB representative

Grounding

• Verify grounding • Re-route wires • Refer to GMC-RM001x-EN-P

230VAC is varying

• Check VAC Loading • Check VAC Source • Verify wiring

Control circuit improperly wired

Verify control wiring and programming

Engaged

Contactor failure (contacts welded together)

Verify by monitoring CONSTAT_41/42 Contact AB representative

Disengaged

No faults or failures

N/A

Contactor failure (contacts welded together)

Verify by monitoring CONSTAT_41/42 Contact AB representative

LED failure

Verify by monitoring CONSTAT_41/42 Contact AB representative

+24V signal not functioning properly

See other Troubleshooting tables

Contactor failure (coil damaged)

Contact A-B representative

No 230V signal

• Verify wiring • Verify 230VAC source

Rapidly engaging/disengaging

Engaged Off (unintended) Disengaged

Publication 2090-IN009F-EN-P, November 2004

Page 19

Resistive Brake Module Installation Instructions

19

General Troubleshooting Use the table below for troubleshooting motor faults that may result from the RBM on a specific axis. Condition:

Potential Cause is:

Possible Resolution is:

No Rotation (drive faults)

Improper timing

Adjust delay times of brake output signals

Improper wiring

Verify wiring

Improper wiring

Verify wiring

RBM contactor disengaged (connection open between drive and motor)

• +24V supply is off • Verify wiring • Drive not enabled • Duty cycle: exceeded; allow RBM to cool. • Contact AB representative

RBM contactor engaged (direct connection between drive and motor)

• Verify wiring • Contact AB representative

No Rotation (no fault action)

Specifications for the Resistive Brake Module are provided below.

Specifications

Drive Voltage

Power Specifications (per phase): Resistance 1

Peak Energy

Peak Drive Current

Continuous Power

Volts

Ohms

Joules

Amps0-pk 2

Ampsrms

Watts

2090-XB33-16

230 or 460

16

2090-XB33-32

230 or 460

32

150

33

23

30

2090-XB120-01

230 or 460

1

2090-XB120-03

230 or 460

3

290

106

75

45

2090-XB120-06

230 or 460

6

Catalog No.

1 Tolerance = +10%, - 10% 2 0-pk refers to peak of sine wave

Publication 2090-IN009F-EN-P, November 2004

Page 20

20

Resistive Brake Module Installation Instructions

Environmental Specifications

Value

Vibration • operating

0.35 mm (0.014 in.) max. displacement at 5-53 Hz 2g max. acceleration at 53 to 500 Hz

Shock • operating

15g, 11 msec half sine

Altitude

1500 m

Humidity

5% to 95% non-condensing

Storage temperature

-25° C 70° C

(-13° F) (158° F)

Ambient operating temperature 1 • minimum • maximum

0° C 50° C

(32° F) (122° F)

Air flow clearance • above and below • left and right

50 mm 0 mm

(1.97 in.) (0 in.)

Temperature limits • T1 (Fault) • T2 (Warning output)

80°±5° C 65°± 5° C

(176±9° F) (119°±9 ° F)

Duty cycle: • 2090-XB33-16 • 2090-XB33-32 • 2090-XB120-01 • 2090-XB120-03 • 2090-XB120-06

Complete stop with 2 15:1 inertia mismatch

(5000 ft)

60 per hour, or 2 once per minute

1Power performance increases about 5.5W for every 1°C (3.1W/°F) drop in ambient temperature. 2 Refer to the Motion Control Selection Guide (publication GMC-SG001x-EN-P) for proper sizing.

Connectors

Type

Torque Nm

(lbs-in.)

4-position plugable Phoenix-type (7.62mm spacing)

0.5 - 0.6

(4.4 - 5.3)

0.5 - 0.6

(4.4 - 5.3)

0.22 - 0.25

(1.9 - 2.2)

2.5 - 2.9

(22.1 - 25.7)

2.5 - 2.9

(22.1 - 25.7)

0.22 - 0.25

(1.9 - 2.2)

0.5 - 0.6

(4.4 - 5.3)

2090-XB33-xx Drive Connection (TB1) Motor Connection (TB2) I/O Terminals (TB3) 1

8-position plugable Phoenix-type (5.08mm spacing)

2090-XB120-xx Drive Connection (TB1) Motor Connection (TB2) I/O Terminals (TB3)

4-position plugable 42 Series Molex (12mm spacing) 8-position plugable Phoenix-type (5.08mm spacing)

2-position plugable 230V Power Terminals (TB4) Phoenix-type (7.62mm spacing)

Publication 2090-IN009F-EN-P, November 2004

Page 21

Resistive Brake Module Installation Instructions

21

Wiring

Requirements

Material

Stranded copper

2090-XB33-xx TB1 - Drive Connection and TB2 - Motor Connection maximum 1 minimum 1

6 mm2 –

(10 AWG) –

TB3 - I/O maximum minimum

1.5 mm2 0.08 mm2

(16 AWG) (28 AWG)

TB1 - Drive Connection and TB2 - Motor Connection maximum 1 minimum 1

25.0 mm2 2.50 mm2

(3 AWG) (14 AWG)

TB3 - I/O maximum minimum

1.50 mm2 0.08 mm2

(16 AWG) (28 AWG)

TB4 - 230V Input maximum minimum

4.0 mm2 0.20 mm2

(10 AWG) (24 AWG)

2090-XB120-xx

Voltage Drive, Motor, and 230V Aux

600V

I/O

250V

Temperature (per UL) 2 • preferred • manufacturer minimum • field wiring minimum

105° C 90° C 75° C

(221° F) (194° F) (167° F)

Maximum Length • TB1 - Drive • TB2 - Motor • TB3 - I/O • TB4 - 230V Input

See system level requirements for power cable length restrictions. 3 N/A for I/O.

1 Specific gauge of motor power cable depends on motor/drive combination. 2 Separate UL standards exist for manufactured and field wiring. Installation must comply with local regulations. 3 If this product is installed within the European Union or EEC regions and requires the CE mark or is installed in Australia and New Zealand and requires C-tick marking, refer to Related Documentation on page 24 for installation and integration instructions defining total length restrictions on a system level.

Mechanical Specifications

Value

Mounting 1 • Hex cap screws • Torque

M6 1 Nm metric (english) minimum

(1/4 in. - 20) (9 in-lb)

Mounting position

Vertical, within ±2°

Product Outline 2090-XB33-xx • Height • Depth • Width

238.3 mm 198.6 mm 70.0 mm

(9.38 in.) (7.82 in.) (2.76 in.)

2090-XB120-xx • Height • Depth • Width

339 mm 195 mm 110 mm

(13.38 in.) (7.68 in.) (4.37 in.)

Publication 2090-IN009F-EN-P, November 2004

Page 22

22

Resistive Brake Module Installation Instructions

Mechanical Specifications Clearances • Top • Side • Bottom

Value

2

50 mm 0 mm 50 mm

(1.97 in.) (0 in.) (1.97 in.)

Weight • 2090-XB33-16 • 2090-XB33-32

1.91 Kg

(4.22 lbs)

• 2090-XB120-01 • 2090-XB120-03 • 2090-XB120-06

2.75 Kg

(6.06 lbs)

1 Additional dimensional information is provided in Figure 2 on page 6. 2 Combustible material adjacent to the brake module may require additional restrictions (i.e., Clearance based on ambient temperature of the brake module within the application).

Safety Contactor Specifications - Allen-Bradley 100S Series The information in this section is adapted from the Allen-Bradley Safety Product Catalog (Publication S114-CA001x-EN-P). That document should be referred to for the most recent information on the 100S Series Contactors. 24V Coil Power Specifications

Voltage Range Vdc

Coil Consumption Watts

Operating Time milliseconds

Pickup

19.2 to 26.4

9.2

40 to 70

Dropout

2.4 to 14.6

0

17 to 23

Hold-In

14.6 to 26.4

9.2

N/A

Ie

Ratings for Switching AC Motors - AC-2, AC-3, AC-4

[A] kW (50 Hz)

AC-3 23

AC-1 32

230V 7.5

HP (60 Hz)

380V, 415V, 400V 11

500V 11

690V 11

1 115V

230V

200V

230V

460V

575V

2

3

5

7.5

15

15

230V Coil Power Specifications

Voltage Range Vac

Coil Consumption VA/W

Operating Time milliseconds

Pickup

195.5 to 253.0

200/110

20.0 to 40.0

Dropout

69.0 to 138.0

0

10.0 to 60.0

Hold-In

138.0 to 253.0

16/4.5

N/A

Ie

Ratings for Switching AC Motors - AC-2, AC-3, AC-4

[A] kW (50 Hz)

AC-3 85

3

AC-1 100

Publication 2090-IN009F-EN-P, November 2004

230V 25

380V, 415V, 400V 45

HP (60 Hz) 500V 45

690V 45

1

3

115V

230V

200V

230V

460V

575V

7.5

15

25

30

60

60

Page 23

Resistive Brake Module Installation Instructions

23

Auxiliary Contact Specifications Auxiliary Contacts in Contactor Catalog Number 100-S 1 Current Switching V n/a at 40° C (104° F)

A

10 at 60° C (10°0 F)

A

6

V

24

48

120

240

400

500

600

690

A

6

6

6

3

2

1.5

1.2

0,7

V

24

48

125

220

440

A

3

1.5

0.6

0.3

0.2

Short-Circuit Protection gG Fuse Type 2 Coordination

A n/a

Rated Impulse Voltage Uimp kV n/a

Insulation Voltage (between control and load circuit DIN,VDE 0106,Part 101 (NAMUR recommendation)

V

Between auxiliary contacts: 250 V Between load and direct-connected aux. circuits: 690 V

AC-1Ith

AC-15 at Rated Operating Voltage

DC-13 at Rated Operating g Voltage

Positively Guided Contacts

Yes, NO and NC mutually unrestricted, including N.C. in relation to N.O.

1 Information adapted from the Allen-Bradley Safety Product Catalog (Publication S114-CA001A-EN-P), page 53.

Accessory Equipment

The cables provide an interface between the Resistive Brake Module and drive power terminals. Refer to RBM Wiring Requirements on page 13 for pin, description, and signal information about the connector kit. Description

Catalog Number

Kinetix® 6000 Drive Interface Cable, Resistive Brake - 14 AWG, 66cm

2090-XXNRB-14F0P7

Kinetix 6000 Drive Interface Cable, Resistive Brake - 4, 8, or 10 AWG

2090-XXNRB-aFxxPyy 1, 2

Ultra™ Drive Interface Cable, Resistive Brake - 14 AWG, 132cm

2090-XXNRB-14F1P3

Ultra Drive Interface Cable, Resistive Brake - 6, 8 or 10 AWG

2090-XXNRB-aFxxPyy 1,2

Connector Kit, Resistive Brake, 33A (TB1, TB2, TB3 Connectors)

2090-XNRBM-1

Connector Kit, Resistive Brake, 106A (TB1, TB2, TB3, TB4 Connectors)

2090-XNRBM-2

1 Where a = wire gauge in AWG. 2 Where xx = cable length in full meters, and yy = length in decimeters.

Publication 2090-IN009F-EN-P, November 2004

Page 24

Related Documentation

These publications provide additional information concerning related Allen-Bradley products. To order printed copies, contact your Allen-Bradley Distributor. To view and download, go to Literature Library at http://www.rockwellautomation.com/literature.

For Information About

Read This Document

Publication Number

Installing, wiring, and troubleshooting a Kinetix 6000 drive

Kinetix 6000 Installation Manual

2094-IN001x-EN-P

Configuring a Kinetix 6000 drive and system

Kinetix 6000 Integration Manual

2094-IN002x-EN-P

Programming a motion application using Logix

Logix Controller Motion Instruction Set Reference Manual

1756-RM007x-EN-P

ControlLogix™ motion and application examples

ControlLogix Motion Module Programming Manual

1756-RM086x-EN-P

Configuring and troubleshooting ControlLogix motion modules

ControlLogix Motion Module Setup and Configuration Manual

1756-UM006x-EN-P

Minimizing and controlling system-level noise

System Design for Control of Electrical Noise

GMC-RM001x-EN-P

Sizing and configuring an application

Motion Book Servo Sizing CD (v4.0 or above)

Motion Book-mmmyy

Servo drives, motor, and accessories, including general technical specifications

Motion Control Selection Guide

GMC-SG001x-EN-P

Information about international standards EN1050 and EN954 estimation and safety performance categories.

Understanding the Machinery Directive

SHB-900

For more information refer to our web site: www.ab.com/motion For Allen-Bradley Technical Support information refer to: www.ab.com/support or Tel: (1) 440.646.5800

Allen-Bradley, A-B, and Kinetix are registered trademarks of Rockwell Automation. ControlLogix, Ultra3000, and Ultra5000 are trademarks of Rockwell Automation. Windows is a registered trademark of Microsoft Corporation. UL is a registered trademark of Underwriters Laboratories, Inc.

www.rockwellautomation.com Corporate Headquarters Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 53202-5302 USA, Tel: (1) 414.212.5200, Fax: (1) 414.212.5201 Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444 Europe: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36-BP 3A/B, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacific: Rockwell Automation, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 Headquarters for Dodge and Reliance Electric Products Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC 29615-4617 USA, Tel: (1) 864.297.4800, Fax: (1) 864.281.2433 Europe: Rockwell Automation, Brühlstraße 22, D-74834 Elztal-Dallau, Germany, Tel: (49) 6261 9410, Fax: (49) 6261 1774 Asia Pacific: Rockwell Automation, 55 Newton Road, #11-01/02 Revenue House, Singapore 307987, Tel: (65) 351 6723, Fax: (65) 355 1733

Publication 2090-IN009F-EN-P, November 2004 Supersedes Publication 2090-IN009E-EN-P

319232-P06 Copyright © 2004 Rockwell Automation. All rights reserved. Printed in USA.