Resistive Brake Module Installation Instructions
Troubleshooting
17
There are no field replaceable components in an RBM. If problems persist after attempting to troubleshoot the system, contact your Allen-Bradley representative for further assistance.
24 VDC Status LED The Status LED is ON when 24V is applied between COIL_A1 and COIL_A2 (e.g., a Brake Enable signal is received from a drive). Use the table below for troubleshooting the RBM using the 24 VDC Status LED. If 24 VDC Status LED is:
Steady Green
Blinking Green (audible clicking)
RBM Contactor Status is:
Potential Cause is:
Possible Resolution is:
Contactor engaged – direct connection between drive and motor
No faults or failures
N/A
Contactor disengaged – no connection between drive and motor
Contactor failure
Verify by monitoring CONSTAT_41/42 status (output is NC) Contact AB representative
Contactor rapidly engaging/disengaging
Recommended grounding not followed
• Verify grounding • Route wires away from noise sources • Refer to GMC-RM001x-EN-P
Control circuit improperly wired
Verify control wiring and programming
No faults or failures
N/A
+24V not applied between COIL_A1 and COIL_A2
• +24V supply is off • Verify wiring • Drive not enabled • Contact AB representative
T1 (Fault) thermostat open
Duty cycle: exceeded; allow RBM to cool.
Off (intended)
Off (unintended)
Contactor disengaged (connection open between drive and motor)
Publication 2090-IN009F-EN-P, November 2004
Page 18
18
Resistive Brake Module Installation Instructions
230 VAC Auxiliary Power Status LED (2090-XB120-xx RBM only) The 230 VAC Status LED is ON when 230V AC is applied to L1 and L2 (TB4) and the contactor is engaged by applying 24V DC across COIL_A1 and COIL_A2 (e.g., a Brake Enable signal is received from a drive). Use the table below for troubleshooting the RBM using the 230 VAC Status LED. ‘1 If 230 VAC Status LED is: Steady Green
Blinking Green (audible clicking)
Off (intended)
RBM Contactor Status is:
Potential Cause is:
Possible Resolution is:
Engaged
No faults or failures
N/A
Disengaged
Contactor failure
Verify by monitoring CONSTAT_41/42 Contact AB representative
Grounding
• Verify grounding • Re-route wires • Refer to GMC-RM001x-EN-P
230VAC is varying
• Check VAC Loading • Check VAC Source • Verify wiring
Control circuit improperly wired
Verify control wiring and programming
Engaged
Contactor failure (contacts welded together)
Verify by monitoring CONSTAT_41/42 Contact AB representative
Disengaged
No faults or failures
N/A
Contactor failure (contacts welded together)
Verify by monitoring CONSTAT_41/42 Contact AB representative
LED failure
Verify by monitoring CONSTAT_41/42 Contact AB representative
+24V signal not functioning properly
See other Troubleshooting tables
Contactor failure (coil damaged)
Contact A-B representative
No 230V signal
• Verify wiring • Verify 230VAC source
Rapidly engaging/disengaging
Engaged Off (unintended) Disengaged
Publication 2090-IN009F-EN-P, November 2004
Page 19
Resistive Brake Module Installation Instructions
19
General Troubleshooting Use the table below for troubleshooting motor faults that may result from the RBM on a specific axis. Condition:
Potential Cause is:
Possible Resolution is:
No Rotation (drive faults)
Improper timing
Adjust delay times of brake output signals
Improper wiring
Verify wiring
Improper wiring
Verify wiring
RBM contactor disengaged (connection open between drive and motor)
• +24V supply is off • Verify wiring • Drive not enabled • Duty cycle: exceeded; allow RBM to cool. • Contact AB representative
RBM contactor engaged (direct connection between drive and motor)
• Verify wiring • Contact AB representative
No Rotation (no fault action)
Specifications for the Resistive Brake Module are provided below.
Specifications
Drive Voltage
Power Specifications (per phase): Resistance 1
Peak Energy
Peak Drive Current
Continuous Power
Volts
Ohms
Joules
Amps0-pk 2
Ampsrms
Watts
2090-XB33-16
230 or 460
16
2090-XB33-32
230 or 460
32
150
33
23
30
2090-XB120-01
230 or 460
1
2090-XB120-03
230 or 460
3
290
106
75
45
2090-XB120-06
230 or 460
6
Catalog No.
1 Tolerance = +10%, - 10% 2 0-pk refers to peak of sine wave
Publication 2090-IN009F-EN-P, November 2004
Page 20
20
Resistive Brake Module Installation Instructions
Environmental Specifications
Value
Vibration • operating
0.35 mm (0.014 in.) max. displacement at 5-53 Hz 2g max. acceleration at 53 to 500 Hz
Shock • operating
15g, 11 msec half sine
Altitude
1500 m
Humidity
5% to 95% non-condensing
Storage temperature
-25° C 70° C
(-13° F) (158° F)
Ambient operating temperature 1 • minimum • maximum
0° C 50° C
(32° F) (122° F)
Air flow clearance • above and below • left and right
50 mm 0 mm
(1.97 in.) (0 in.)
Temperature limits • T1 (Fault) • T2 (Warning output)
80°±5° C 65°± 5° C
(176±9° F) (119°±9 ° F)
Duty cycle: • 2090-XB33-16 • 2090-XB33-32 • 2090-XB120-01 • 2090-XB120-03 • 2090-XB120-06
Complete stop with 2 15:1 inertia mismatch
(5000 ft)
60 per hour, or 2 once per minute
1Power performance increases about 5.5W for every 1°C (3.1W/°F) drop in ambient temperature. 2 Refer to the Motion Control Selection Guide (publication GMC-SG001x-EN-P) for proper sizing.
Connectors
Type
Torque Nm
(lbs-in.)
4-position plugable Phoenix-type (7.62mm spacing)
0.5 - 0.6
(4.4 - 5.3)
0.5 - 0.6
(4.4 - 5.3)
0.22 - 0.25
(1.9 - 2.2)
2.5 - 2.9
(22.1 - 25.7)
2.5 - 2.9
(22.1 - 25.7)
0.22 - 0.25
(1.9 - 2.2)
0.5 - 0.6
(4.4 - 5.3)
2090-XB33-xx Drive Connection (TB1) Motor Connection (TB2) I/O Terminals (TB3) 1
8-position plugable Phoenix-type (5.08mm spacing)
2090-XB120-xx Drive Connection (TB1) Motor Connection (TB2) I/O Terminals (TB3)
4-position plugable 42 Series Molex (12mm spacing) 8-position plugable Phoenix-type (5.08mm spacing)
2-position plugable 230V Power Terminals (TB4) Phoenix-type (7.62mm spacing)
Publication 2090-IN009F-EN-P, November 2004
Page 21
Resistive Brake Module Installation Instructions
21
Wiring
Requirements
Material
Stranded copper
2090-XB33-xx TB1 - Drive Connection and TB2 - Motor Connection maximum 1 minimum 1
6 mm2 –
(10 AWG) –
TB3 - I/O maximum minimum
1.5 mm2 0.08 mm2
(16 AWG) (28 AWG)
TB1 - Drive Connection and TB2 - Motor Connection maximum 1 minimum 1
25.0 mm2 2.50 mm2
(3 AWG) (14 AWG)
TB3 - I/O maximum minimum
1.50 mm2 0.08 mm2
(16 AWG) (28 AWG)
TB4 - 230V Input maximum minimum
4.0 mm2 0.20 mm2
(10 AWG) (24 AWG)
2090-XB120-xx
Voltage Drive, Motor, and 230V Aux
600V
I/O
250V
Temperature (per UL) 2 • preferred • manufacturer minimum • field wiring minimum
105° C 90° C 75° C
(221° F) (194° F) (167° F)
Maximum Length • TB1 - Drive • TB2 - Motor • TB3 - I/O • TB4 - 230V Input
See system level requirements for power cable length restrictions. 3 N/A for I/O.
1 Specific gauge of motor power cable depends on motor/drive combination. 2 Separate UL standards exist for manufactured and field wiring. Installation must comply with local regulations. 3 If this product is installed within the European Union or EEC regions and requires the CE mark or is installed in Australia and New Zealand and requires C-tick marking, refer to Related Documentation on page 24 for installation and integration instructions defining total length restrictions on a system level.
Mechanical Specifications
Value
Mounting 1 • Hex cap screws • Torque
M6 1 Nm metric (english) minimum
(1/4 in. - 20) (9 in-lb)
Mounting position
Vertical, within ±2°
Product Outline 2090-XB33-xx • Height • Depth • Width
238.3 mm 198.6 mm 70.0 mm
(9.38 in.) (7.82 in.) (2.76 in.)
2090-XB120-xx • Height • Depth • Width
339 mm 195 mm 110 mm
(13.38 in.) (7.68 in.) (4.37 in.)
Publication 2090-IN009F-EN-P, November 2004
Page 22
22
Resistive Brake Module Installation Instructions
Mechanical Specifications Clearances • Top • Side • Bottom
Value
2
50 mm 0 mm 50 mm
(1.97 in.) (0 in.) (1.97 in.)
Weight • 2090-XB33-16 • 2090-XB33-32
1.91 Kg
(4.22 lbs)
• 2090-XB120-01 • 2090-XB120-03 • 2090-XB120-06
2.75 Kg
(6.06 lbs)
1 Additional dimensional information is provided in Figure 2 on page 6. 2 Combustible material adjacent to the brake module may require additional restrictions (i.e., Clearance based on ambient temperature of the brake module within the application).
Safety Contactor Specifications - Allen-Bradley 100S Series The information in this section is adapted from the Allen-Bradley Safety Product Catalog (Publication S114-CA001x-EN-P). That document should be referred to for the most recent information on the 100S Series Contactors. 24V Coil Power Specifications
Voltage Range Vdc
Coil Consumption Watts
Operating Time milliseconds
Pickup
19.2 to 26.4
9.2
40 to 70
Dropout
2.4 to 14.6
0
17 to 23
Hold-In
14.6 to 26.4
9.2
N/A
Ie
Ratings for Switching AC Motors - AC-2, AC-3, AC-4
[A] kW (50 Hz)
AC-3 23
AC-1 32
230V 7.5
HP (60 Hz)
380V, 415V, 400V 11
500V 11
690V 11
1 115V
230V
200V
230V
460V
575V
2
3
5
7.5
15
15
230V Coil Power Specifications
Voltage Range Vac
Coil Consumption VA/W
Operating Time milliseconds
Pickup
195.5 to 253.0
200/110
20.0 to 40.0
Dropout
69.0 to 138.0
0
10.0 to 60.0
Hold-In
138.0 to 253.0
16/4.5
N/A
Ie
Ratings for Switching AC Motors - AC-2, AC-3, AC-4
[A] kW (50 Hz)
AC-3 85
3
AC-1 100
Publication 2090-IN009F-EN-P, November 2004
230V 25
380V, 415V, 400V 45
HP (60 Hz) 500V 45
690V 45
1
3
115V
230V
200V
230V
460V
575V
7.5
15
25
30
60
60
Page 23
Resistive Brake Module Installation Instructions
23
Auxiliary Contact Specifications Auxiliary Contacts in Contactor Catalog Number 100-S 1 Current Switching V n/a at 40° C (104° F)
A
10 at 60° C (10°0 F)
A
6
V
24
48
120
240
400
500
600
690
A
6
6
6
3
2
1.5
1.2
0,7
V
24
48
125
220
440
A
3
1.5
0.6
0.3
0.2
Short-Circuit Protection gG Fuse Type 2 Coordination
A n/a
Rated Impulse Voltage Uimp kV n/a
Insulation Voltage (between control and load circuit DIN,VDE 0106,Part 101 (NAMUR recommendation)
V
Between auxiliary contacts: 250 V Between load and direct-connected aux. circuits: 690 V
AC-1Ith
AC-15 at Rated Operating Voltage
DC-13 at Rated Operating g Voltage
Positively Guided Contacts
Yes, NO and NC mutually unrestricted, including N.C. in relation to N.O.
1 Information adapted from the Allen-Bradley Safety Product Catalog (Publication S114-CA001A-EN-P), page 53.
Accessory Equipment
The cables provide an interface between the Resistive Brake Module and drive power terminals. Refer to RBM Wiring Requirements on page 13 for pin, description, and signal information about the connector kit. Description
Catalog Number
Kinetix® 6000 Drive Interface Cable, Resistive Brake - 14 AWG, 66cm
2090-XXNRB-14F0P7
Kinetix 6000 Drive Interface Cable, Resistive Brake - 4, 8, or 10 AWG
2090-XXNRB-aFxxPyy 1, 2
Ultra™ Drive Interface Cable, Resistive Brake - 14 AWG, 132cm
2090-XXNRB-14F1P3
Ultra Drive Interface Cable, Resistive Brake - 6, 8 or 10 AWG
2090-XXNRB-aFxxPyy 1,2
Connector Kit, Resistive Brake, 33A (TB1, TB2, TB3 Connectors)
2090-XNRBM-1
Connector Kit, Resistive Brake, 106A (TB1, TB2, TB3, TB4 Connectors)
2090-XNRBM-2
1 Where a = wire gauge in AWG. 2 Where xx = cable length in full meters, and yy = length in decimeters.
Publication 2090-IN009F-EN-P, November 2004
Page 24
Related Documentation
These publications provide additional information concerning related Allen-Bradley products. To order printed copies, contact your Allen-Bradley Distributor. To view and download, go to Literature Library at http://www.rockwellautomation.com/literature.
For Information About
Read This Document
Publication Number
Installing, wiring, and troubleshooting a Kinetix 6000 drive
Kinetix 6000 Installation Manual
2094-IN001x-EN-P
Configuring a Kinetix 6000 drive and system
Kinetix 6000 Integration Manual
2094-IN002x-EN-P
Programming a motion application using Logix
Logix Controller Motion Instruction Set Reference Manual
1756-RM007x-EN-P
ControlLogix™ motion and application examples
ControlLogix Motion Module Programming Manual
1756-RM086x-EN-P
Configuring and troubleshooting ControlLogix motion modules
ControlLogix Motion Module Setup and Configuration Manual
1756-UM006x-EN-P
Minimizing and controlling system-level noise
System Design for Control of Electrical Noise
GMC-RM001x-EN-P
Sizing and configuring an application
Motion Book Servo Sizing CD (v4.0 or above)
Motion Book-mmmyy
Servo drives, motor, and accessories, including general technical specifications
Motion Control Selection Guide
GMC-SG001x-EN-P
Information about international standards EN1050 and EN954 estimation and safety performance categories.
Understanding the Machinery Directive
SHB-900
For more information refer to our web site: www.ab.com/motion For Allen-Bradley Technical Support information refer to: www.ab.com/support or Tel: (1) 440.646.5800
Allen-Bradley, A-B, and Kinetix are registered trademarks of Rockwell Automation. ControlLogix, Ultra3000, and Ultra5000 are trademarks of Rockwell Automation. Windows is a registered trademark of Microsoft Corporation. UL is a registered trademark of Underwriters Laboratories, Inc.
www.rockwellautomation.com Corporate Headquarters Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 53202-5302 USA, Tel: (1) 414.212.5200, Fax: (1) 414.212.5201 Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444 Europe: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36-BP 3A/B, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacific: Rockwell Automation, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 Headquarters for Dodge and Reliance Electric Products Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC 29615-4617 USA, Tel: (1) 864.297.4800, Fax: (1) 864.281.2433 Europe: Rockwell Automation, Brühlstraße 22, D-74834 Elztal-Dallau, Germany, Tel: (49) 6261 9410, Fax: (49) 6261 1774 Asia Pacific: Rockwell Automation, 55 Newton Road, #11-01/02 Revenue House, Singapore 307987, Tel: (65) 351 6723, Fax: (65) 355 1733
Publication 2090-IN009F-EN-P, November 2004 Supersedes Publication 2090-IN009E-EN-P
319232-P06 Copyright © 2004 Rockwell Automation. All rights reserved. Printed in USA.