For the Allen-Bradley 2803-VIM2

Page 379

Appendix

I

ASCII or Control Char.

Decimal Value

NUL

0

SOH

1

STX

2

ETX

3

EOT

4

ENQ

5

ACK

6

BEL

7

LF

I ‘0 I

*

I

*

G

ASCII Conversion

I 42 I 2A I

J

1

74

1

UA i

Table

I

1

106

1

6A

Page 380

This page is a scan with no text; see it in the PDF.

Page 381

Appendix

Definition

H

Definition of Terms

Objectives

This appendix supplies definitions to terms used in this manual which relate to vision technology in general, and to terms which relate specifically to the VIM2 module.

of Terms

There are terms in this manual which are used in the machine vision industry, and others which are specific to the VIM2 system. These and other key terms are defined below: l

Acceptance Range -The range of values that are accepted for vision tool range tests. The acceptance range is defined by high and low range limits. The high and low range limits define the range of variation that can be tolerated above and below the nominal value. Range limits are defined by the user.

l

Arc hiving ConfigurationsWhen you are configuring the VIM2 module for an inspection application, the configuration is stored in the VIM2’s volatile RAM. If you wish to save the configuration, store the configuration in the VIM2’s EEPROM memory. You can store, or archive, two different configurations in EEPROM.

l

Blob -A group of contiguous (adjacent) white or black pixels along a line of pixels in an image. The line gages of the VIM2 module ca.n make edge, center, and width measurements for blobs.

l

Block Transfer - A block transfer is a method of communicating a “block” of data between a PLC and an I/O module. In this case, the I/O module is the VIM2 module and the block of data can be results data, configuration data, or statistics data. All block transfers are invoked by an instruction from the PLC controller.

l

Brightness Probe - A sample area of the image used to measure light intensity or “brightness.” This probe can be used to: - Measure the brightness of a small section of the image. -Detect lighting brightness changes from inspection to inspection in order to compensate for variations in brightness,

Page 382

Definition

Appendix of Terms

H

H-2

Defirdion of Terms (continued)

0 Column - A row of pixels in the vertical (Y) direction in the image or on the display screen. l

Brightness Registration -This feature allows you to adjust all the threshold image settings based on a permanent change in lighting brightness level in the workstage area.

l

Configuration Blocks -Blocks of data that may be uploaded to, or downloaded from, a PLC controller, or to a computer connected through the VIM2 module’s RS-485 port. The configuration blocks contains configuration information about measurement windows, line gages, the brightness probe, math tools, and other setup information. One of the more im,portant aspects of the VIM2 module is that configuration data can be transferred to and from the PLC controller or other computer. As a result, configuration data can be sent to the PLC controller or other host, the VIM2 module removed and replaced, and the replacement module easily reconfigured by downloading a configuration from the host to the VIM2 module. Note that two different configurations can also be stored on board the VIM2 module in non-volatile EEPROM.

l

Constant - A selectable numerical value used as a parameter when using the math tools.

l

Contrast -The brightness difference between the workpiece and the background as seen in the image. Good contrast is important for reliable operation of the vision tools used in the VIM2 module.

l

Decision output-The Decision output is a discrete output which indicates the accept/reject status of an inspection. This status is available through both the PLC controller (the De&iorz bit) and through the swingarm (the Decision output).

l

Depth of Field - The range in which objects focus clearly. It is measured from the distance beyond the ideal focal point to the distance in front of it in which objects remain in focus.

l

EEPROM Configuration - One of two configurations which are stored in the VIM2 module’s non-volatile electrically eraseable programmable memory (EEPROM).

l

Field of View - The inspected area that is seen through a lens or optical instrument by the sensor grid of the video camera.

Page 383

Appendix

Definition of Terms

H

Definition of Terms H-3 l

Icon -A symbolic, pictorial representation of a feature or a menu (group of icons). “Picking” an icon with the light pen enables/disables or selects a feature or parameter, or selects the depicted icon menu. The icons and icon menus are introduced in Chapter 6. The complete icon menu branching map is illustrated in Appendix A.

l

Host - A PLC, or a computer connected to the VIM2 module through the RS-485 port, which communicates with the VIM2 module. A host device can collect fault, results, statistics, or configuration information from the VIM2 module (see also Master Host).

l

Field (Video) - A single scan of the video camera image. The camera produces a steady stream of video fields, each consisting of a series of scan lines (rasters).

l

Gray Level -A measure of relative brightness from black, through many increments of gray, to white.

l

Light Pen -The input device used to interact with the VIM2 module. The light pen has a retractable tip, and is used to select or “pick” icons and menus on the video monitor.

l

Line Gage - Line gages represent one type of inspection tool provided by the VIM2 module. A line gage inspects a set of horizontally or vertically aligned pixels (found in a row or column).

l

Math Tools -User-defined formulas which combine or adjust the results of inspection tools.

l

Master Host-A host device (PLC, or a computer connected to the VlM2 module through the RS-485 port,), which is designated as master host in the VIM2 module’s configuration. A master host, as distinguished from a host, can configure the VIM2 module, and trigger inspections, as well as collect fault, results, statistics, or configuration information (see also Host).

l

Operator - A symbol (such as + ) or term (such as AND) that represents the operation performed by a math tool upon one or more operands.

l

Operand -A quantity or value (such as a constant, or the result of a line gage function or window), upon which the operator in a math tool acts.

(continued)

Page 384

Appendix

Definition of Terms

H

H-4

Definition of Terms l

Pick -The action of depressing the tip of the light pen against a displayed icon or value on the monitor screen to “select” the function or menu represented by that icon.

l

Pixel - One picture element (or dot) in a video image. The video image is a matrix of pixels.

l

RAM Configuration - The “working” configuration (the configuration by which the VIM.2 module operates), which is stored in the VIM2 module’s volatile random access memory (RAM).

l

Results -The value generated by a vision tool as a consequence of the tool inspecting a threshold image, or in the case of a math tool, the value generated as a consequence of the operator acting upon the operands.

l

Results Blocks -Data tables stored by the VIM2 module which can be transferred to the PLC or other host. The results blocks contain information indicating the accept/reject status of acceptance range tests for the brightness probe, line gages, windows, and math tools. The actual probe luminance gray value, pixel counts for each window, line gage results for each line gage, and math tool results are communicated through the results blocks. The VIM2 module generates two results blocks for each inspection cycle.

l

Row -A line of pixels across the image in the horizontal (X) direction.

l

Shift Registration -This feature allows you to adjust the inspection tool positions based on a permanent change in the nominal workplece position in the workstage area.

l

Standoff - The distance between the inspected workpiece and the camera body.

l

Statistics Blocks - Data tables stored by the VIM2 module which can be transferred to the PLC or other host. The statistics blocks contain accumulated statistical data for the brightness probe, line gages, windows, and math tools; the statistics are gathered while the VIM2 module operates in “learn” mode. The statistics include the triggers processed, inspections failed per tool/ probe, and tool/probe minimum, maximum, and average values. Statistics are collected for measurements which fall within the respective acceptance range only (statistics are not kept for failed tools). The VIM2 module generates four statistics blocks for each inspection cycle.

(continued)

Page 385

Appendix

Definition of Terms

H

Definitian

Of

Terms

(continued)

H-5

0 Swingarm -A screw terminal connector installed on the front panel of many 1771-I/0 modules, including the VIM2 module. It’s used to connect wires to the module. l

Threshold - A gray level used to transform a gray-scale video image into a binary image. Pixels whiter than the threshold are converted to white (11, values darker or equal to the Threshold are converted to black (0).

l

Vision Tool - The VIM2 module vision tools include the line gages and windows. Vision tools are used to take measurements and generate accept/reject decisions.

l

Window - Windows are shapes which define localized image areas to be inspected in measurement operations. The user defines the window size, shape, and location. The vision operation used in VIM2 module windows is area measurement by pixel counting.

l

Workpiece - The part or object inspected by the VIM2 module.

l

Workstage -The specific area where the vision inspections for an application are to take place.