For the Allen-Bradley 700-HN122

Page 1

Technical Data

Relays and Timers Specifications Bulletin Number 700 Topic

Page

General Purpose Relays

2

Timing Relays

41

NEMA Industrial Relays

81

IEC Control Relays

93

Solid State Relays

109

Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource

Description

Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1

Provides general guidelines for installing a Rockwell Automation industrial system.

Product Certifications website, http://www.ab.com

Provides declarations of conformity, certificates, and other certification details.

You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.

Page 2

700-HA General Purpose Relay

Relays and Timers Specifications Cat. No. 700-HA… Electrical Ratings

Pilot Duty Rating‡

NEMA B300

Rated Thermal Current (Ith )

HA = 10 A – 120V, 240V HAX = 6 A – 120V, 240V

Rated Insulation Voltage (Ui)

250V IEC – 300V UL/CSA Inductive

Contacts

Make

Break

Hp

120V AC

30 A

3A

1/3

240V AC

15 A

1.5 A

1

General Purpose

10 A, 240V AC

Resistive

10 A, 30V DC

Min. Low Energy Permissible Load

HA = 10V, 5 mA HAX = 5V, 2 mA

Permissible Coil Voltage Variation

Pickup: 80…110% of Nominal Voltage at 50 Hz 80…110% of Nominal Voltage at 60 Hz 80…110% of Nominal Voltage at DC

Coil Consumption ±10%

AC Coils

50 Hz

60 Hz

Inrush

3.3 VA

2.85 VA

Sealed

2.2 VA

1.9 VA

DC Coils

1.3 W 20% of nominal V AC

Must Dropout Voltage

10% of nominal V DC 50 MΩ (700-HA and 700-HAB) 30 MΩ (700-HAX)

Max. Contact Resistance

Design Specification/Test Requirements Electrical Pole-to-Pole

2000V

Contact to Coil

2000V

Electrical Life (Operating)

100 000 min.

Degree of Protection (Open Type) IEC 529

IP 40

Mechanical Life Cycles (AC/DC)

> 20 x 106/ 50 x 106

Switching Frequency Operations

3600/HR

Coil Voltages

See Product Selection

Mechanical

Operating Time

Max. Pickup

10 ms

Max. Dropout

10 ms

Endurance

5G

Maximum Operating Rate Vibration Shock

4 Ops/s Operational

2.5 G

Endurance

50 G

Operational

9G

Operating

AC/DC

–40…+70 °C

Storage

AC/DC

–40…+100 °C

Environmental Temperature Altitude

2000 m (6560 ft)

Insulating Material

Molded High-Dielectric Material

Construction Enclosure Contact Material

Transparent Dust Cover 700-HA:

10 A– AgNi

700-HAX:

6 A–Bifurcated/Gold Plating AgNi

Terminal Markings on Socket

In accordance with EN50 0005

Sockets

8-Pin Socket, 700-HN100, -HN125, -HN204 11-Pin Socket, 700-HN101, -HN126, -HN205

Certifications cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with Bulletin 700-HN sockets noted above (File No. E3125, Guide NLDX/NLDX7), CE Marked, CSA Certified, UR Certified (File 229473)

Standards

UL508, CSA C22.2 No. 14, EN 61810-1

‡ NEMA Rating Chart is in publication 700-SG003*

2

Rockwell Automation Publication 700-TD552A-EN-P

Page 3

Relays and Timers Specifications

700-HA General Purpose Relay k Reduction Factor

Cycles

Max. Switching Current (A)

700-HA Relay Performance Graphs

Load (kVA) Contact life vs. AC1 load at 1,800 cycles/h

Voltage DC (V) Breaking capacity for DC1 load at 1,800 cycles/h.

COS

Load reduction factor vs. cos φ

A = load applied to one contact B = load applied to two contacts in series C = load applied to three contacts in series Time Module Cat. No. 700-HT3 Electrical Ratings Operating Voltage Range

12…240V AC (50/60 Hz) 12…240V DC

Power Consumption

0.1 W (12V) 1.0 W (230V)

Degree of Protection of Input (B1) Terminal

IP 20 (Guarded Terminal)

Input Terminal Wire Range

1.0 x 0.2 mm2…2.5 mm2 (24 AWG…14 AWG) 2.0 x 0.2 mm2…1.5 mm2 (24 AWG…16 AWG)

Input Terminal Torque Range

0.45…0.8 Nm (4…7 lb-in.)

LED Indicator

Red

Repeat Accuracy‡

±1%

Recovery Time

<50 ms

Selectable Timing Ranges

Three DIP switches, seven ranges (set from 5…100% of range): 1 s, 10 s, 100 s, 10 min, 100 min, 10 h, 100 h

Selectable Timing Modes

Three DIP switches, eight modes: 1. Power On–Delay 2. Power On One-Shot 3. Power On Repeat Cycle, On Start 4. Signal On-Delay and Signal Off-Delay 5. Signal Off-Delay 6. Signal On-One-Shot 7. Signal Off-One-Shot 8. Signal On and Signal Off Watchdog Monitor

Adjustable Trimmer Scale Accuracy

±5% of Time Range

Mechanical

Environmental Temperature

Operating Storage

–20 °C…+50 °C (–4 °F…+122 °F) –55 °C…+85 °C (–67…+185 °F)

Altitude

2000 m (6560 ft)

Enclosure

Gray Plastic Housing

Mounting with Socket Only

8- or 11-Pin Socket with Module Plug

Sockets

700-HN204 (8-Pin with Plug) 700-HN205 (11-Pin with Plug)

Certifications cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), CE Marked

Standards

UL508, CSA C22.2 No. 14, EN 61810-1

Construction

‡ At constant voltage and temperature.

Rockwell Automation Publication 700-TD552A-EN-P

3

Page 4

700-HA General Purpose Relay

Relays and Timer Specifications

Timing Charts, Cat. No. 700-HT3 Multi-Function Time Module (t = Time Range 0.05 s…100 h) Terms: U is Power Input R is Relay Output S Signal, +A1 Socket, B1 Timer t is the resulting Time Delay (Red LED)

3. Power On Repeat Cycle, On Start

Apply power (U) to timer. Relay contacts (R) change state immediately and the time delay (t) begins. When the time delay is complete, the contacts return to their shelf state for time delay (t) (time on = time off). This cycle will repeat until the power is removed. Terminal B1 is not used in this mode.

1. Power On-Delay Apply power (U) to timer. Relay contacts (R) change state after time delay (t) is complete. Contacts return to their shelf state when power is removed. Terminal B1 is not used in this mode.

4. Signal On-Delay and Signal Off-Delay

2. Power On One-Shot Apply power (U) to timer. Relay contacts (R) change state immediately and the time delay begins. When the time delay (t) is complete, contacts return to their shelf state. Contacts return to their shelf state when power is removed. Terminal B1 is not used in this mode.

4

Apply power (U) to timer. When the signal (S) is closed the time delay (t) begins, after the time delay is complete the relay contacts (R) change state. Opening the signal starts the time delay, after the time delay is complete the contacts return to their shelf state. If the signal is closed or opened before the time delay is complete, the time delay is reset. Contacts return to their shelf state when power is removed.

Rockwell Automation Publication 700-TD552A-EN-P

Page 5

Relays and Timer Specifications

700-HA General Purpose Relay

Cat. No. 700-HT3 Timing Modes, Time Description, Timing Charts, and DIP Switch Selections 5. Signal Off-Delay Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) change state immediately. When the signal is opened, the time delay (t) begins. If the signal is closed before the time delay is complete, the time delay is reset and the relay remains energized. When the time delay is complete, the contacts return to their shelf state. Contacts return to their shelf state when power is removed.

7. Signal Off One-Shot Apply power (U) to timer. When the signal (S) is closed and then opened, the relay contacts (R) change state immediately and the time delay (t) begins. After the time delay begins, opening or closing the signal will not reset the time delay. When the time delay is complete, the contacts return to their shelf state. Contacts return to their shelf state when power is removed.

8. Signal On and Signal Off Watchdog Monitor 6. Signal On One-Shot Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) change state immediately and the time delay (t) begins. After the time delay begins, opening or closing the signal will not reset the time delay. When the time delay is complete, the contacts return to their shelf state. Contacts return to their shelf state when power is removed.

Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) energize immediately and the time delay (t) begins. If the signal is opened before the time delay is complete, the relay remains energized and the time delay is reset. When the time delay is complete the contacts return to their shelf state. If the signal is opened after the time delay is complete, the relay contacts energize immediately and the same time delay begins. Continuous cycling of the signal at a rate that is faster than the time delay will cause the relay contacts to remain energized. Contacts return to their shelf state when power is removed.

Rockwell Automation Publication 700-TD552A-EN-P

5

Page 6

700-HA General Purpose Relay

Relays and Timer Specifications

Approximate Dimensions Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes.

54.1 (2-1/8)

32.8 (1-3/10)

36.5 (1-9/20)

Bulletin 700-HA Relay

5.2 (13/64)

12.5 (1/2)

6.2 (15/64)

50 (1-63/64)

1.0 (0.04)

35.0 (1.38)

27.0 (1.06)

7.5 (0.3)

1000 (39-3/8)

Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes

6

Cat. No.

A

B

C

D

Approx. Shipping Wt.

199-DR1

35 (1-3/8)

27 (1-1/16)

7.5 (19/64)

1.02 (1/64)

1.85 kg (4.07 lb) (10/pkg)

199-DR4

35 (1-3/8)

27 (1-1/16)

15 (19/32)

2.3 (3/32)

3.68 kg (8 lb) (5/pkg)

Rockwell Automation Publication 700-TD552A-EN-P

Page 7

Relays and Timer Specifications

700-HA General Purpose Relay

Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes. 24.6 (31/32)

40.1 (1-37/64)

20.8 (53/64)

30.0 (1-3/16)

26 (1-1/32)

24.9 (63/64)

65.0 (2-35/64)

54.9 (2-5/32) 51.1 (2-1/64)

4.2 (5/32) 38.0 (1-1/2) #4–40 M3 Cat. No. 700-HN100

33.0 (1-19/64)

14.7 (37/64)

Panel Mounting

Cat. No. 700-HN125

2

Wire Size: 2 x 2.5 mm2 Single Wire – Up to 12 AWG Double Wire – 2 x 2.5 mm2 (#2–14 AWG…#2–20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

Wire Size: 2 x 2.5 mm Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (#2-14 AWG… #2-20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

26 (1-1/32)

30 (1-3/16)

59.2 (2-1/3) 7.9 (0.31)

24.6 (31/32) 20.8 (53/64)

26.9 (1.06)

65.0 (2-35/64)

54.9 (2-5/32) 4.2 (5/32)

51.1 (2-1/64)

38.0 (1-1/2) #4-40 M3 Cat. No. 700-HN101 2

52.3 (2.06)

Panel Mounting

Wire Size: 2 x 2.5 mm Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (#2–14 AWG…#2–20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

Cat. No. 700-HN126 2

Wire Size: 2 x 2.5 mm Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (#2–14 AWG…#2–20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

Rockwell Automation Publication 700-TD552A-EN-P

7

Page 8

700-HA General Purpose Relay

Relays and Timer Specifications

Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes. 33.5 (1.32) 33.5 (1.32)

26.9 (1.06)

11.0 (0.43)

77.5 (3.05)

3.2 (0.13)

26.9 (1.06)

11.0 (0.43) 20.4 (0.80)

20.4 (0.80)

77.5 (3.05)

49.7 (1.96)

3.2 (0.13)

35.5 (1.40)

16.8 (0.66)

21.6 (0.85)

16.8 (0.66)

38.0 (1.50)

38.0 (1.50)

Cat. No. 700-HN204

Cat. No. 700-HN205

Wire Size: 2 x 2.5 mm2 Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (#2–14 AWG …#2–20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

38.0 (1.50)

54 (2.13)

6.3 (0.25)

10.5 (0.41)

Cat. No. 700-HT3 2

Wire Size: 2 x 1.5 mm (#2 – 16 AWG…#1–20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

Rockwell Automation Publication 700-TD552A-EN-P

35.5 (1.40)

21.6 (0.85)

4.0 (0.16)

4.0 (0.16)

Wire Size: 2 x 2.5 mm2 Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (#2–14 AWG… #2–20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

8

49.7 (1.96)

Page 9

Relays and Timer Specifications

700-HB General Purpose Relay

Specifications Cat. No. 700-HB… Electrical Ratings Pilot Duty Rating‡

NEMA B300

Rated Thermal Current ( Ith )

15 A – 120V, 240V

Rated Insulation Voltage (Ui)

250V IEC-300V UL/CSA Make

Break

Hp

Inductive Contacts

2 -Pole

3 -Pole

2 -Pole

120V AC

60 A

30 A

6A

3A

3/4

240V AC

30 A

15 A

3A

1.5 A

2

General Purpose

3 -Pole

15 A, 240V AC

Resistive

15 A, 30V DC

Min. Low Energy Permissible Load

1000 mW (10V, 10 mA) 80…110% of Nominal Voltage at 50 Hz

Permissible Coil Voltage Variation

80…110% of Nominal Voltage at 60 Hz 80…110% of Nominal Voltage at DC

Coil Consumption ±10%

AC Coils

50 Hz

60 Hz

Inrush

3.3 VA

2.85 VA

Sealed

2.2 VA

1.9 VA

DC Coils

1.3 W 25% of VA

Max. Allowable Leakage

10% of W

Max. Contact Resistance

50 mΩ Design Specification/Test Requirements Electrical

Dielectric Withstand Voltage Pole-to-Pole

2500V

Contact to Coil

4000V Mechanical

Degree of Protection (Open Type) IEC 529

IP 40 > 10 x 106/30 x 106

Mechanical Life Cycles (AC/DC) Switching Frequency Operations

3600/HR

Coil Voltages Operating Time (ms)

See Overview/Product Selection Pickup

20 ms

Dropout

4 ms

Maximum Operating Rate Vibration Shock

4 Ops/s

Endurance

5G

Operational

1.5 G

Endurance

50 G

Operational

15 G Environmental

Temperature

Operating

AC/DC

–40…+70 °C

Storage

AC/DC

–40…+100 °C

Altitude

2000 m (6560 ft) Construction

Insulating Material

Molded High Dielectric Material

Enclosure

Transparent Dust Cover

Contact Material

AgCdO

Terminal Markings on Socket

In accordance with EN50 0005

Sockets

700-HN153, -HN154

Certifications cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with Bulletin 700-HN sockets noted above (File No. E3125, Guide NLDX/NLDX7), CE Marked, CSA Certified, UR Certified (File No. 229473)

Standards

UL508, CSA C22.2 No. 14, EN 61810-1

‡ NEMA Rating Chart is in publication 700-SG003*

Rockwell Automation Publication 700-TD552A-EN-P

9

Page 10

700-HB General Purpose Relay

Relays and Timer Specifications

Cycles

Technical Data

Load (kVA)

Maximum Switching Current (A)

Contact life vs AC1 load at 600 cycles/h.

Voltage DC (V)

Reduction Factor

Breaking capacity for DC1 load at 600 cycles/h. Load applied to 1 contact. A = for N.O. types B= other types

(Highly Resistive)

COS (Inductive) Load Reduction factor vs cos φ

10

Rockwell Automation Publication 700-TD552A-EN-P