Page 1 of Relays and Timers Specifications, Bulletin Number 700

Spec sheet · Allen-Bradley

Relays and Timers Specifications, Bulletin Number 700

Spec sheet128 pagesPDF 10 MB

Technical data for Allen-Bradley Bulletin 700 relays, timers and sockets, including the 700-HN122 2-pole screw terminal socket.

Download the PDF10 MB

Covers · 1 model

The models it covers

Summary

What is in it

Rockwell Automation technical data for the Allen-Bradley Bulletin 700 relay and timer line. It gives electrical ratings, coil data, operating conditions, certifications, timing modes and approximate dimensions for general purpose relays (700-HA, -HB, -HC, -HK and others), timing relays, NEMA industrial relays, IEC control relays and solid state relays, along with their matching sockets. The 700-HN122 appears as a 2-pole screw terminal socket for the 700-HK relay family.

Its parts

  1. General Purpose Relays
  2. Timing Relays
  3. Industrial Relays
  4. Control Relays
  5. Solid State Relays

From the sheet

Key facts from this sheet

Each line names its page in the PDF.

Rockwell Automation technical data (publication 700-TD552A-EN-P) with specifications for Bulletin 700 general purpose, timing, industrial, control and solid state relays and their sockets. The 700-HN122 appears in it as a 2-pole screw terminal socket for the 700-HK relay and the 700-HNK42 ultra slim timing relay, with its rating, wiring data and dimensions.

Read for this summary: pages 1 to 2, 17 to 21 and 56 to 58 of 128.

Type
2-pole screw terminal socket for the 700-HK relay p. 17
Rating
2 x 5 A at 70 °C p. 17
Wire size
2 x 2.5 mm2; double wire #2-14 AWG to #2-20 AWG, solid or stranded p. 19, 57
Strip and torque
Strip 9 mm (3/8 in.); torque 0.8 N•m (7 lb•in) p. 19, 57
Panel mounting
3 mm (1/8 in.) mounting holes, M3 screws p. 19
Timer use
Also takes the 700-HNK42 timing relay; 78.0 mm total height together p. 57
Other 700-HK sockets
700-HN121 (1-pole, 10 A at 70 °C); 700-HN222 (2-pole, 2 x 8 A at 70 °C); spring clamp 700-HN223, 700-HN224 p. 17
700-HK relay
2-pole DPDT, 8 A thermal current; 1-pole SPDT, 16 A p. 17
700-HK coil
1.2 VA (AC coils), 0.5 W (DC coils) p. 17
700-HK contacts
700-HK3_: AgNi; 700-HKX_: AgNi with gold plating; 700-HKM_: AgSnO2 p. 17
700-HK temperature
-40 to +70 °C operating; -40 to +85 °C storage p. 17
700-HNK42 timer
DPST-NO contact; time range by the left two DIP switch pins, mode by the right two p. 56, 57
700-HNK modes
On-delay, one shot, repeat cycle off-start, repeat cycle on-start p. 56
Terminal markings
Per EN 50005 p. 17

What this sheet walks you through

  • 700-HK relay electrical and mechanical specifications p. 17
  • Choosing a socket for the 700-HK relay p. 17
  • Dimensions and wiring data of the 700-HN121 and 700-HN122 sockets p. 19
  • DIN mounting rails 199-DR1 and 199-DR4 p. 19
  • Setting the time range and operating mode of the 700-HNK timer p. 56
  • Dimensions of the 700-HNK timer on its sockets p. 57
  • Specifications of the 700-HA, 700-HLT, 700-HLS and 700-HR relays p. 2, 20, 21, 58

Good to know

  • The dimensions are approximate and not meant for manufacturing use. p. 19

Questions this sheet answers

What relay plugs into the Allen-Bradley 700-HN122 socket?

It is listed as a 2-pole socket for the 700-HK relay, and the 700-HNK42 ultra slim timing relay also mounts on it. p. 17, 57

What is the current rating of the 700-HN122?

2 x 5 A at 70 °C. p. 17

What wire size and torque does the 700-HN122 take?

2 x 2.5 mm2 wire, solid or stranded, stripped 9 mm, with the screws tightened to 0.8 N•m (7 lb•in). p. 19

Is there a higher rated 2-pole socket for the 700-HK relay?

The 700-HN222 screw terminal socket is rated 2 x 8 A at 70 °C, as is the 700-HN224 spring clamp socket. p. 17

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Relays and Timers Specifications1
    1. 1 - General Purpose Relays2
    2. 2 - Timing Relays41
    3. 3- Industrial Relays81
    4. 4 - Control Relays93
    5. 5 - Solid State Relays109
  2. Back Cover128

From the PDF’s own bookmarks.

The whole text · 13 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Pages 121 to 128121-128

The file

Revision and size

Part no.700-TD552A-EN-P
RevisionSeptember 2014
PublisherRockwell Automation
Pages128
PDF10 MB
TextText from the PDF itself.
700-TD552A-EN-P

The first pages · 4 of 128

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 128
Page 2
Page 2of 128
Page 3
Page 3of 128
Page 4
Page 4of 128