The text of a spec sheet · part 5 of 13

Relays and Timers Specifications, Bulletin Number 700, pages 41 to 50

Pages 41 to 50 of 128

The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 700-HN122

Page 41

Relays and Timer Specifications

700-FE DIN Rail Mounted Timing Relay

Function and Connection Diagrams (A) On-Delay A1/A2

U Output

(B) Off-Delay

A1/A3

15

18 15 t

LED

A1/A2

U

A2

18

1 N.O. (SPST)

Output LED t

B1 S

A1

A1/B1 18 15

S

15

A2

18

A1 B1 S

15

A2

18 16

1 N.O. (SPST) U Output LED

A1/A2 18 15 16 t

15

A1

A2

18 16

(D) One Shot

A1/B1

Output

15 18 16 t

1 C/O (SPDT)

(F) Flasher (Repeat Cycle Starting with Pulse) A1/A2 15 t

15

A1

18

A2

18

A1

15

1 N.O. (SPST) U Output LED

A1/A2

S LED

1 C/O (SPDT)

U Output LED

U

A1/A2

A1/A2

A1

15

A2

18

A1

15

A2

18 16

18 t t t t t 15

LED

1 N.O. (SPST)

18 1516 t

U Output

A2

18 16

U Output

A1/A2 t t t t

15 18 16 t

LED

1 C/O (SPDT) 1 C/O (SPDT) (L) Pulse Converter

(E) Fleeting Off-Delay

LED

1)

1)

A1/A2 B1

S A1 B1

15 t A2

18 16

A1/A2 A1/B1

U S Output LED t t

A1

S B1

15

18 15 16

A2

18 16

1 C/O (SPDT) (Y) Star-Delta Timing Relay U

A1/A2

A1

17

A2

18 28

17/18 ∆ LED tu = 50...65 ms

17/28

∆

Bi-Color LED: 1 C/O (SPDT) or 1 N.O. Contact Timers

Single Color LED: 2 N.O. with Common

LED U = green: Supply voltage available. LED Relay = red: Output is energized.

Rockwell Automation Publication 700-TD552A-EN-P

ON = green OFF = red

41

Page 42

700-FE DIN Rail Mounted Timing Relay

Relays and Timer Specifications

Specifications Time Characteristics (according to VDE 0435, part 2021)

1 N.O. Setting Accuracy

SPDT ±5% of full scale

Repeatability

±1% of setting (typical) By voltage: ±0.01%/%ΔU By temperature: ±0.25%/°C

Tolerance

By voltage: ±0.001%/%ΔU By temperature: ±0.025%/°C

Supply Supply Voltage

24V AC/DC‡ and 110…240V AC, 50/60 Hz AC

Voltage Tolerance

24…48V DC and 24…240V AC, 50/60 Hz

–15%/+10%

DC

–15%/+20%

Power Consumption

0.5 W at 24V DC, 5 VA at 240V AC

Time Energized

100%

Reset Time

100 ms

Cable Length (Supply Voltage Control)

Max. 250 m (750 feet) Pulse Control (B1) ≥ 250 ms

Impulse Duration

≥ 50 ms (AC), ≥ 30 ms (DC)

Input Voltage supply voltage range

Input Current

1 mA

Cable Length

Max. 250 m without parallel load between B1 and A2 Max. 50 m with load (< 3 kΩ) between B1 and A2 Outputs

Contact Type Dielectric Withstand Voltage

1 N.O. contact Contact-to-coil Power

Switching Capacity

According to IEC 947-5-1

1250 VA AC-1

5 A /250V AC (resistive load)

AC-14

1 A/250V AC (inductive load)

DC-13 According to UL 508 Short-Circuit Resistance

Life

1 Form C – SPDT contact 4000 V

1 A/24V DC (inductive load) NEMA D300 - 1 A/300V AC 6 A gL (Fast Blow Fuse)

Mechanical

20 million operations

Electrical

0.4 million at 1 A/250V AC, resistive 0.4 million at 0.5 A/250V AC, cos φ = 0.4 0.4 million at 1 A/24V DC, resistive

State Indicator

1 Bi-Color LED (Supply; Relay)

Certifications cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked

Standards

EN/IEC 60947-1, EN/IEC 60947-5-1, UL 508, CSA 22.2 No. 14

‡ Voltage is either 24V DC or AC 50/60 Hz.

42

Rockwell Automation Publication 700-TD552A-EN-P

Page 43

Relays and Timer Specifications

700-FE DIN Rail Mounted Timing Relay

General Specifications 1 N.O.

SPDT

Insulation Characteristics

2 kV AC/50 Hz test voltage according to VDE 0435 and 4 kV 1.2/50 μs surge voltage according to IEC 60947-1 between all inputs and outputs

EMC/Interference Immunity

The following requirements are fulfilled: Surge capacity of the supply voltage according to IEC 61000-4-5: Level 3 Burst according to IEC 61000-4-4: Level 3 ESD discharge according to IEC 61000-4-2: Level 3

EMC/Emmission electromagnetical fields according to EN 55 022: Class B

Safe Isolation according to VDE 0106 T 101

Climatic Withstand

56 cycles (24 hr) at 25…40 °C and 95% relative humidity according to IEC 60068-2-30

Vibration Resistance

4 g in three axes at 10…500 Hz, test FC according to IEC 60068-2-6

Shock Resistance

50 g according to IEC 68-2-27

Protection Class IEC 60947-1

Enclosure:IP 40 Terminal:IP 20

Weight Certifications Ambient Temperature

60 g

60 g cULus, CE Certified cULus, Germanischer Lloyd, CE Certified Open:–25…+60 °C Enclosed:–25…+45 °C Storage:–40…+85 °C

Connections

Screw terminal M3 for Pozidriv No.1, Philips and slotted screws No.2. suitable for power screw-driver. Rated tightening torque 8.8 lb.-in. (max. 1.0 Nm) For terminal cross-sections of 1 x 0.5 mm2…2 x 1.5 mm2 (solid) or 2 x 1.5 mm2 (stranded with sleeve), #20…14 AWG. Finger protection according to EN 50274

Mounting

For surface mounting in any position; snap-on mounting on 35 mm DIN Rail or by adapter and two screws (M4 type)

Disposal

Synthetic materials without dioxin according to EC/EFTA-Notification No. 93/0141/D electrical contacts are AgCdO

Rockwell Automation Publication 700-TD552A-EN-P

43

Page 44

700-FE DIN Rail Mounted Timing Relay

Relays and Timer Specifications

Approximate Dimensions Approximate dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

80.0 (3-5/32)

13 (0.51)

22.5 (0.89)

43.0 (1-11/16)

4.3 (0.17)

45.0 (1-25/32)

35.0 (1.38) 58.0 (2.28) 17 12 (0.67) (0.47)

17.5 (11/16)

66.0 (2-9/16) 70.0 (2-49/64)

4.3 (0.17) 9.0 (0.35)

Cat. No. 700-FE…

44

Rockwell Automation Publication 700-TD552A-EN-P

2.0 (0.08) 5.5 (0.22) Cat. No. 199-FSA…

75.0 (2.95)

Page 45

Relays and Timer Specifications

700-FS DIN Rail Mounted Timing Relay

Connection Diagrams (A) On-Delay

(G) Flasher (Repeat Cycle Starts with Pause) Output Output

Output

Output 1 Output 2 Output 2

(I) On-Delay Pulse Generator (B) Off-Delay (Min. Pulse AC 50 ms…DC 30 ms) Output LED

Output

‡ Output 1

(J) On-Delay (Pulse Controlled)

Output 2 Output 2

(C) On- and Off-Delay

Output LED

(K) One Shot/Watch Dog (Pulse Controlled) Output LED

‡

(D) One Shot

Output LED Output

(On) ON-Function (Off) OFF-Function

Output 1

Output 1

Output 2

Output 2

LED

LED

(E) Fleeting Off-Delay (Min. Pulse AC 50 ms…DC 30 ms) (L) Pulse Converter (Min. Pulse AC 50 ms…DC 30 ms) Output t

LED

‡

Output LED

‡

(F) Flasher (Repeat Cycle Starts with Pulse) Cleverly Designed Function Display LED (Green) Output

Output in Rest Position, No Timing Output in Rest Position, Time Running Output in Operation Position, No Time Running Output in Operation Position, Time Running * A VOLTAGE OTHER THAN THE SUPPLY VOLTAGE CAN BE USED AT B1, BUT MUST BE WITHIN VOLTAGES SPECIFIED ON TIMER.

A voltage other than the supply voltage can be used at B1, but must be within voltages specified on timer. † Output 2 is selectable as instantaneous contact with sliding switch (⊗) on front panel (instantaneous when switch is down, timed when switch is up). ‡ Available on multifunction "M," and single function "A" or "B" option timing relays along with code "4" (2PDT contacts). Bridge or potentiometer 10 kΩ, 0.25 W min. (low voltage) for external time setting. Set timer dial to 0.0.

Rockwell Automation Publication 700-TD552A-EN-P

45

Page 46

700-FS DIN Rail Mounted Timing Relay

Relays and Timer Specifications

Special Function Flasher (Repeat Cycle Starting with Pulse or Pause) Timing Relays Description t2 Setting Up Switch Down 1 Range Setting

Supply Voltages (A1/A2) Z12 12V DC

Seperate Range Settings

U23 24…48V DC, 24…240V AC, 50/60 Hz t1 Setting 700-FSH3V 700-FSH3U Function Diagram / Connection Diagram

(H) Flasher (Repeat Cycle Starting with Pulse or Pause) The repeat cycle timer permits different settings for on and off times. The following operating modes are possible: Oscillating mode; repeat cycle starts with voltage applied at A1 and B1, and continues to repeat until voltage is off. One cycle mode; started by energizing B1 with voltage on A1 and A2. Output starts with pulse or pause (switch ⊗ Up or Down). 700-FSH3U provides (1) range setting for t1 and t2. 700-FSH3V provides (2) range settings for t1 and t2. Supply Voltage Controlled, Oscillating Mode Starting with Pause, Switch ⊗ is Up

U S Output LED t2 t2 t1 t1

A1/A2 A1/B1 15 18 16

A1 B1

18 16

A2

Output LED

A1/A2 t1 t2

A1

A1/B1

U S Output

15

Pulse Controlled, Output Starts With Pause (Min. Pulse AC 50 ms, DC 30 ms), Switch ⊗ is Up One Cycle Mode, Voltage Supplied at A1 and A2, then Pulsing “s” to Energize B1 will Initiate One Cycle.

U S

Supply Voltage Controlled, Oscillating Mode Starting with Pulse, Switch ⊗ is Down

S B1 t1 t2 t2 15 18 16

LED

15

U S Output

18 16

A1/A2 t1

A1/B1 t2

LED

LED Operation Chart Ñ Green LED

46

15

A2

18 16

Output at Shelf State, No Timing - LED OFF Output at Shelf State, Time is Running - LED Flashing Output NO Contact is Closed, No Timing - LED On Output NO Contact is Closed, Time is Running - LED Long Flashing

Rockwell Automation Publication 700-TD552A-EN-P s A1 B1

15

A2

18 16 t1 t2 15 18 16

Note: If B1 is pulsed, a one full time cycle consisting of t1 and t2 is completed.

LED LED LED LED

A1 B1

Pulse Controlled, Output Starts with Pulse (Min. Pulse AC 50 ms, DC 30 ms), Switch ⊗ is Down One Cycle Mode, Voltage Supplied at A1 and A2, then Pulsing “s” to Energize B1 will Initiate One Cycle.

t1 t2 15 18 16 A2 t1

A1/A2 A1/B1

Page 47

Relays and Timer Specifications

700-FS DIN Rail Mounted Timing Relay Function Diagram / Connection Diagram

(Q) Off-Delay without Supply Voltage (True Off-Delay), When input power is turned on, the output contact changes state. When the power is removed, the time delay begins. The output contact returns to shelf state at the end of the time delay.

U Output tp

A1/A2 t

15

A1

15

18 16

LED

A2

18 16

U tp

Output 1 t

Output 2 LED t

A1/A2

A1

15

15 18 16 25 28 26

A2

18 16 28 26

25

Note: Min. pulse (tp) required: 800 ms (Y) Star-Delta Timing Relay, When power is applied, the output contact 17/18(Y) changes state. After the time setting, the output contact 17/18(Y) returns to shelf state. After the fixed time (50… 60 ms), the output contact 17/28Δ changes state. Both output contacts return to shelf state whenever the power is removed.

U

A1/A2 t tu = 50...65 ms

LED

A1

17

A2

18

17/18 17/28

Rockwell Automation Publication 700-TD552A-EN-P

28

47

Page 48

700-FS DIN Rail Mounted Timing Relay

Relays and Timer Specifications

Specifications Time Characteristics (according to VDE 0435, Part 2021) Setting Accuracy

±5% of full scale

Repeatability

±0.2% of the setting values

Tolerance

Voltage: ±0.001%/%ΔU Temperature: ±0.025%/°C

General Data Insulation Characteristics

2 kVAC/50 Hz test voltage according to VDE 0435 and 6 kV 1.2/50 μs surge voltage according to IEC 947-1 between all inputs and outputs

EMC/Interference Immunity

Performance of following requirements: Surge capacity of the supply voltage according to IEC 1000-4-5: 4 kV 1.2/50 μs Burst according to IEC 1000-4-4: 6 kV 6/50 ns ESD discharge according to IEC 10004-2: Contact 8 kV, air 8 kV Electromagnetic HF field according to IEC 801-3 and conducted electromagnetic HF signal according to IEC 801-6: Level 3

EMC/Emission

Electromagnetic fields according to EN 55 022: class B

Safe Isolation

According to VDE 106, part 101

Climatic Withstand

56 Cycles (24 hr) at 25…40 °C and 95% relative humidity according to IEC 68-2-30 and IEC 68-2-3

Supply Supply Voltages

24…48V DC and 24…240V AC, 50/60 Hz (multi voltage)

Voltage Tolerance

–20…+20% (DC), –15…+10% (AC)

Power Consumption

0.5 W at 24V DC, 5 VA at 240V AC

Time Energized

100%

Reset Time

50 ms

Voltage Interruption

≤20 ms without reset (supply voltage)

Input Impedance

Relay ON: 3K-13K ohms Relay OFF: 0.7K-4K ohms

Cable Length (Supply Voltage Control)

Max. 250 m (800 ft)

Pulse Control (B1) Pulse Duration

≥50 ms (AC), ≥30 ms (DC)

Vibration Resistance

4 g in three axes at 10…500 Hz, test FC according to IEC 68-2-6

Input Voltage

Supply voltage range

Shock Resistance

50 g according to IEC 68-2-27

Input Current

1 mA

Max. Leakage Current

400 micro Amps

Protection Class

Enclosure:IP 40 IP 30 (Single-function) Terminal:IP 20 according to IEC 947-1

Max. 250 m (800 ft) without parallel load between B1 and A2 Max. 50 m (160 ft) with load (<3 kΩ) between B1 and A2

Weight

100 g

Cable Length

Approval

UL, C-UL

Ambient Temperature

Open: –25…+60 °C Enclosed: –25…+45 °C Storage: –40…+85 °C

Terminals

Screw terminal M3.5 for Number 2 Posidrive, Philips, and slotted screws. Suitable for power screwdriver. Rated tightening torque 8.8 lb.-in. (0.8 N•m, max. 1.2 N•m). Dual-chamber system for terminal cross-sections of 1 x 0.5 mm2…2 x 2.5 mm2 (solid) or stranded 2 x 2.5 mm2 (flexible with sleeve), #20…14 AWG. Finger protection according to VDE 0106.

Mounting

Front mounting; For snap-on mounting on 35 mm DIN Rail or screw fixing by adapter and 2 screws (M4 type)

Disposal

Synthetic material without dioxin according to EC/EFTA notification Number 93/0141/D electrical contacts with cadmium

Certifications cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked

Standards

EN/IEC 60947-1, EN/IEC 60947-5-1, UL 508, CSA 22.2 No. 14

Outputs Contact Type

Relay as changeover switch

Dielectric Coil to Contact Withstand Voltage

5000 V Voltage: 440V AC Current Ith (AC-1): 8 A (5 A for 700FSQ) Power: 2000 VA According to IEC 947-5-1:

Switching Capacity

3 A/440V AC (inductive load, AC 14) 3 A/250V AC (inductive load, AC 15) 1 A/24V DC (inductive load, DC 13) According to UL 508: 1.5 A/250V AC (B300) 3 A/120V AC (B300)

Short-Circuit Resistance

10 A gL Mechanical: 30 million operations Electrical operations: 4 Mil. at 1 A/250V AC, cos φ = 1 0.2 Mil. at 6 A/250V AC, cos φ = 1 1.5 Mil. at 1 A/250V AC, cos φ = 0.3

Life

0.3 Mil. at 3 A/250V AC, cos φ = 0.3

Temp. Code T4A 2A 32VDC MAX.

0.5 Mil. at 6 A/24V DC, resistive 2 Mil. at 4 A/24V DC, resistive 2 Mil. at 0.2 A/230V DC, resistive 1 Mil. at 0.4 A/24V DC, L/R = 20 ms

Mounting: Product shall be installed in an enclosure constructed in accordance with the requirements of EN50021.

1 Mil. at 0.2 A/110V DC, L/R = 20 ms 1 Mil. at 0.1 A/230V DC, L/R = 20 ms State Indicator

48

1 LED, combination signal

Rockwell Automation Publication 700-TD552A-EN-P

Page 49

Accessories/ Specifications Specifications Ratings Item Pilot Duty Rating Pin type Operating voltage range Reset voltage

Power consumption

Control outputs

Make Break Hp at 120V AC Hp at 240V AC Accuracy of operating time Setting error Reset time Influence of voltage Influence of temperature Insulation resistance

Dielectric strength

Vibration resistance Shock resistance Ambient temperature Ambient humidity Life expectancy

120V AC 240V AC 120V AC 240V AC

700-HNC NEMA B300 Plug-in 85%…110% of rated supply voltage (12V DC: 90%…110% of rated supply voltage)‡ 10% min. of rated supply voltage§ Relay ON: 1.5 VA (1.1 W) (at 24V AC, 60 Hz) 24V AC: 0.2 VA (0.1 W) (at 24V AC, 60 Hz) Relay OFF: Relay ON: 1.5 VA (1.3 W) (at 120V AC, 60 Hz) 100…120V AC: Relay OFF: 0.8 VA (0.5 W) (at 120V AC, 60 Hz) Relay ON: 1.8 VA (1.5 W) (at 230V AC, 60 Hz) 200…230V AC: Relay OFF: 1.2 VA (0.9 W) (at 230V AC, 60 Hz) Relay ON: 0.9 W (at 12V DC) 12V DC: Relay OFF: 0.07 W (at 12V DC) Relay ON: 0.9 W (at 24V DC) 24V DC: Relay OFF: 0.07 W (at 24V DC) Relay ON: 1.0 W (at 48V DC) 48V DC: Relay OFF: 0.2 W (at 48V DC) Relay ON: 1.3 W (at 110V DC) 100…110V DC: Relay OFF: 0.3 W (at 110V DC) Relay ON: 1.3 W (at 125V DC) 125V DC: Relay OFF: 0.3 W (at 125V DC) 4PDT: 5 A at 250V AC, resistive load (cosφ = 1) Characteristics 30 A 15 A 3A 1.5 A 1/6 Hp 1/6 Hp ±1% FS max. (1 s range: ±1%±10 ms max.) ±10%±50 ms FS max. Min. power-opening time: 0.1 s max. (including halfway reset) ±2% FS max. ±2% FS max. 100 mΩ min. (at 500V DC) 2000V AC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal 2000V AC, 50/60 Hz for 1 min (between operating power circuit and control output) 2000V AC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model) 1500V AC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model) 1000V AC, 50/60 Hz for 1 min (between non-continuous contacts) Malfunction:10…55 Hz, 0.5 mm single amplitude Malfunction:100 m/s2 (approx. 10G) Operating:-10 °C…50 °C (with no icing) Storage:-25 °C…65 °C (with no icing) Operating:35%…85% Mechanical:10 000 000 operations min. (under no load at 1800 operations/hr) Electrical:4PDT: 200 000 operations min. (3 A at 250V AC, resistive load at 1800 operations/hr)

Single-phase, full-wave-rectified power supplies can be used. ‡ When using the 700-HNC continuously in any place where the ambient temperature is in a range of 45 °C…50 °C, supply 90%…110% of the rated supply voltages supply 95%…110% with 12V DC type).

Rockwell Automation Publication 700-TD552A-EN-P

49

Page 50

700-HNC Plug-in Timing Relay

Relays and Timer Specifications

Characteristics, Continued Noise immunity

±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)

Static immunity

Destruction:8 kV Malfunction:4 kV

Enclosure rating

IP40

Weight

Approx. 50 g Emission Enclosure:EN55011 Group 1 class A Emission AC Mains:EN55011 Group 1 class A Immunity ESD:EN61000-4-2:4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference:ENV50140:10 V/m (amplitude modulated, 80 MHz to 1 GHz) (level 3)

EMC

10 V/m (pulse modulated, 900 MHz) Immunity Conducted Disturbance:ENV50141:10 V (0.15…80 MHz) (level 3) Immunity Burst:EN61000-4-4:2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Standards

UL 508, CSA 22.2 No. 14, EN/IEC 61812-1

Certifications cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), CSA Certified (File 224268), CE Marked, CTick Marked

Timing Charts Note :t:Set time Rt:Reset time Operating Mode

Timing Charts / Wiring Diagram

Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7,12-8) Run/Power indicator (PW) Output indicator (UP)

Power (13-14)

One Shot

Power Output

Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7,12-8) Run/Power indicator (PW) Output indicator (UP)

Power (13-14)

Repeat Cycle OFF-Start Time limit contact NC (9-1, 10-2, 11-3, 12-4)

Power Output

Time limit contact NO (9-5, 10-6, 11-7,12-8) Run/Power indicator (PW) Output indicator (UP)

Power (13-14)

Repeat Cycle ON-Start

Power Output

Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7,12-8) Run/Power indicator (PW) Output indicator (UP)

50

Rockwell Automation Publication 700-TD552A-EN-P

Timer Circuit

UP

PW