Page 121

Relays and Timer Specifications

700-SH Solid State Relays

Surge current resistivity for 700-SH75.... 1200A

Surge current resistivity for 700SH100.... 2000A 1800A

1000A

1600A

Inrush current (Apk)

1400A

600A

400A

1200A 1000A 800A 600A

200A

400A 200A

0A 10ms

100ms

1000ms

10000m s

0A 10ms

Energizing time (ms)

100ms

1000ms

10000m s

Energizing time (ms)

Load current vs. ambient temperature characteristics for 700-SH10….

Load current vs. ambient temperature characteristics for 700-SH25….

12

30 700-SN50VHC

10

700-SN50HC 700-SN10

700-SN50(V)HC

25

700-SN25

700-SN10

6

4

No heatsink

15

No heatsink

5

0 -10

0

10

20

700-SN50

10

2

-20

700-SN25

20

700-SN50

Load Current (A)

Load Current (A)

8

30

40

50

60

70

0

80

-20

Ambient temperature (ºC)

-10

0

10

20

30

40

Load current vs. ambient temperature characteristics for 700-SH75….

60

70

80

Load current vs. ambient temperature characteristics for 700-SH5….. 6 700-SN50(V) HC

700-SN50VHC

70

5

700-SN50HC

60

700-SN10

700-SN25

50

60

700-SN50

4

50 700SN10

40

700-SN25

Load Current (A)

Load Current (A)

50

Ambient temperature (ºC)

80

700-SN50

30

No heatsink

3

2 20 1

10

No heatsink

0 -20

-10

0

10

20

30

40

50

60

70

0

80

-20

-10

0

10

20

Ambient temperature (ºC)

30

40

70

80

Ambient temperature (ºC)

Load current vs. ambient temperature characteristics for 700-SH50…. 60 Load current vs. ambient temperature characteristics for 700-SH100…. 120

50 700-SN50VHC

100 700-SN50HC

40

700-SN50VHC

Load Current (A)

700-SN50

80 Load Current (A)

Inrush current (Apk)

800A

60

700-SN10

700-SN10

700-SN25

700-SN50

700-SN50HC

30

700-SN25

20

40

20

10 No heatsink

No heatsink

0 -20

-10

0

10

20

30

40

Ambient temperature (ºC)

50

60

70

80

0 -20

-10

0

10

20

30

40

50

60

70

80

Ambient temperature (ºC)

Rockwell Automation Publication 700-TD552A-EN-P

121

Page 122

700-SH Solid State Relays

Relays and Timer Specifications

Mounting All units are in mm's unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not intended for manufacturing purposes.

24.5

30.0

45.5

Mounting Holes (Bottom View) 5.3

2 x M5 Screws

Load Two Ø 4.4 or M4 Holes

47.5

47.5 58.2

Terminal Arrangement/ Internal Connections (Top View)

Load L1

A2

2 x M3 Screws

Input

Load Power Supply T1

A1

13.0 25 45.5

Cat. No. 700-SH5F…

44.8

28.8

Two Ø 4.4 or M4 Holes

47.5

12.3 2 X M5 Screws

8.6

47.5

58.2

Operating Indicator

APPLY HEATSINK COMPOUND

2 X M3 Screws

5.2 5.25 25 45.5 Cat. No. 700-SH10, -SH25, -SH50, -SH75, -SH100 The proper mounting orientation of the heat sink is so the heat fins run perpendicular to the floor (vertical) to maximize ventilation flow. If the fins do not run perpendicular to the floor, a 30% current derating is required. § When attaching a heat sink to Bulletin 700-SH, apply a thin layer of heat conductive grease (approximately 0.002 in. thick) on the heat sink to maximize heat transfer between the SSR and the heat sink. Recommended types: Silicon based, Dow Corning 340, Toshiba YG6240; Non-silicon based, AOS company type 53300 (Cat. No. 46801-010-01). ♣ Tighten the SSR panel/heat sink mounting screws to a torque of 0.78…0.98 N•m (6.9…8.7 lb•in). Δ Tighten the SSR terminal wiring screws as follows M4: 0.98…1.37 N•m (8.67…12.12 lb•in), M5: 1.57…2.35 N•m (13.89…20.8 lb•in).

122

Rockwell Automation Publication 700-TD552A-EN-P

Page 123

Relays and Timer Specifications

700-SH Solid State Relays 700-SN10

700-SN25

700-SN50

700-SN50HC

700-SN50VHC

♦ Tighten the heat sink mounting screws (M4) to a torque of 0.98…1.37 N•m (8.67…12.12 lb•in). ♠ Heat sink weight: Cat. Nos. 700-S10 = 200 g, 700-S20 = 400 g, 700-S30 = 560 g.

Rockwell Automation Publication 700-TD552A-EN-P

123

Page 124

700-SH Solid State Relays

Relays and Timer Specifications

12

47

27

45

67

27,5

Cat. No. 700-SHCOV

Cat. No.700-SHTRMA 28,5

Load Connection For an AC load, use a power supply rated at 50 or 60 Hz. The maximum operating frequency is 10 Hz. The Bulletin 700-SH has a built-in varistor for surge/inrush protection of AC loads. If additional suppression is required, connect an external varistor across the load device terminals. Select a varistor which meets the load voltage condition outlined in the table below. Load Voltage [V AC]

Varistor Voltage [V]

100…120

240…270

200…240

440…470

380…480

820…1000

Varistor Surge Resistance 1000 A min.

Zero Cross Function A SSR with a zero cross function operates when an AC load voltage reaches the zero point or its vicinity. This reduces clicking noises when the load is switched and minimizes the influence of an inductive load, (e.g., lamp, heater, or motor) on the power supply because the inrush current of the load is reduced. This can also minimize the scale of the inrush current protection circuit.

Output (load voltage)

Input

ON OFF

At a low applied voltage (e.g., 24V AC) the load current is not fully supplied. When the unit is switched ON, the voltage required to power the unit deprives the output signal of the necessary voltage level and thus creates loss time. The lower the load voltage is, the greater the loss time is. This condition, however, will not create any serious problems.

Loss time

For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load.

Load Input

SSR

Load power supply

Note: For additional details when using Solid-State Relays, refer to pub. 700-AT001*, Solid-State Relay Application Guide.

124

Rockwell Automation Publication 700-TD552A-EN-P

Page 125

Relays and Timer Specifications

700-SK Solid State Relays

Input Sensor Module Input Sensor Ratings Cat. No.

Rated Input Voltage

Max. Operating Input Voltage Range

Input Current

Pick-up Voltage

Drop-out Voltage

700-SKICZ24

12…24V DC

6.6…32V DC

8 mA max.

6.6V DC max.

3.6V DC min.

700-SKICA18

100…240V AC

60…264V AC

15 mA max.

60V AC max.

20V AC min.

Output Logic Ratings Cat. No.

Logic Level Supply Voltage

Logic Level Supply Current Draw

4…32V DC

0.1…100 mA

Cat. No. 700-SKICA18

Cat. No. 700-SKICZ24

700-SKICZ24 700-SKICA18

Characteristics Description Pick-up time

20 ms max.

0.1 ms max.

Drop-out time

20 ms max.

0.1 ms max.

Response frequency

10 Hz

1 kHz

Output ON voltage drop

1.6V max. 5 μA max.

Leakage current Output VDRM, VCEO (V)

80 (ref. value)

80 (ref. value)

Output di/dt (A/uS), - Output dv/dt (V/uS), - 2

Output I t (A S), - Output Tj (°C) Max.

150

2

150

Insulation Resistance

100 MΩ min. between input and output

Dielectric Strength

4000V AC, 50/60 Hz for 1 min between input and output

Vibration Resistance (Max.)

10…55 Hz, 1.5 mm double amplitude (10 G)

Shock Resistance (Max.)

1000 m/s2 (100 G)

Ambient Temperature

Operating

–30…+80 °C (–22…+176 °F) with no icing or condensation

Storage

–30…+100 °C (–22…+212 °F) with no icing or condensation

Standards Compliance

UL 508, CSA C22.2 No. 14, EN/IEC 60950

Certifications cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, TÜV Certified

Ambient humidity

Operating

45…85% (no condensation)

Weight

Approx. 18 g

Output SSR Module Control/Input Ratings Cat. No.

Rated Control Voltage

Max. Operating Control Voltage Range

Max. Reverse Control Voltage

-32V DC

15 mA max. at 25 °C (77 °F)

700-SKOZ2Z25 700-SKON2Z25

5…24V DC

4…32V DC

700-SKOC2Z25

Pick-up Voltage

Drop-out Voltage

4V DC max.

1V DC min.

8 mA max.

700-SKOC1Z25

Load/Output Ratings Cat. No. 700-SKOZ2Z25 700-SKON2Z25

Rated Load Voltage

Maximum Load Voltage Range

100…240V AC

Continuous Load Current (Resistive) [A] Min.

Max.§

Max. Inrush Current‡

75…264V AC

0.05

2

30 A (@50/60 Hz, 1 cycle)

700-SKOC2Z25

5…48V DC

4…60V DC

0.1

2

8 A (10 ms)

700-SKOC1Z25

48…200V DC

40…200V DC

0.1

1.5

8 A (10 ms)

With a constant current input system. SSR impedance varies with a change in input voltage. ‡ If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to the “Inrush Current Resistivity” graphs on page 9-193 for more details. § Refer to "Load Current vs. Ambient Temperature Characteristics" graphs on page 9-193 for additional details.

Rockwell Automation Publication 700-TD552A-EN-P

125

Page 126

700-SK Solid State Relays

Relays and Timer Specifications

Output Module, Continued Characteristics Description

Cat. No. 700-SKOZ2Z25

Load Switching Method/Device

Cat. No. 700-SKON2Z25

Cat. No. 700-SKOC2Z25

Cat. No. 700-SKOC1Z25

Triac

Transistor

Pick-up Time

1/2 cycle of load power source cycle + 1 ms max.

1 ms max.

Drop-out Time

1/2 of load power source cycle + 1 ms max.

2 ms max.

20 Hz

100 kHz

Response Frequency Output ON Voltage Drop

1.6V max.

Leakage Current

2.5V max.

1.5 mA max.

Output VDRM, VCEO (V)

1 mA max.

600 (ref.value)

600 (ref.value)

80 (ref.value)

Output di/dt (A/uS)

30

30, 400 (ref.value), Output dv/dt (V/uS)

300

300, - Output I2t (A2S)

10.4

10.4, - Output Tj (°C) Max.

125

125

150

150

Insulation Resistance

100 MΩ min. between input and output

Dielectric Strength

4000V AC, 50/60 Hz for 1 min between input and output

Vibration Resistance (Max.)

10…55 Hz, 1.5 mm double amplitude (10 G) 1000 m/s2 (100 G)

Shock Resistance (Max.) Ambient Temperature

Operating

–30…+80 °C (–22…+176 °F) with no icing or condensation

Storage

–30…+100 °C (–22…+212 °F) with no icing or condensation

Standards Compliance

UL 508, CSA C22.2 No. 14, EN/IEC 60950

Certifications cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, TÜV Certified

Ambient Humidity

Operating

45…85% (no condensation)

Weight

Approx. 18 g

60 Hz cycle time = 16.6 ms, 50 Hz cycle time = 20 ms.

Load Current vs. Ambient Temperature Characteristics

10

9

9

8

8

3 2

100

5 4 3

2

Energizing Time (ms)

10

2000

1000

0

300 500

1

0

100

1

2000

4

6

1000

5

7

300 500

6

700-SKOZ/SKOC1

100

Inrush Current (A)

7

10

Inrush Current (A) Energizing Time (ms)

5000

1000

500

100

200

30 50

10

Inrush Current (A)

30

700-SKOC2

30 50

10

30 50

Inrush Current Resistivity‡ 700-SKOZ/SKON

10

80

Ambient Temperature [° C]

Ambient Temperature [° C]

20

60

-20

0.5

100

80

60

40

20

0

0.5

1

40

1

1.5

20

1.5

2

0

Maximum Load Current (A)

2

-20

Maximum Load Current (A)

For 2 A Versions

Energizing Time (ms)

‡ Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.

126

Rockwell Automation Publication 700-TD552A-EN-P

Page 127

Relays and Timer Specifications

700-SK Solid State Relays

All units are in millimeters unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not to be used for manufacturing purposes. Note: The input module ( Bul. 700-SKI) and output module (Bul. 700-SKO) are compatible with the Cat. No. 700-HN121 socket. 1 5.2

Terminal Arrangement/ Internal Connections (Bottom View)

3 0.5 29 max.

17.4

4.75 1

13 max.

28 max.

5

(+)

4 9.6

(–)

4.7

Input

0.5 4.75

4

4

Load

5

7.5

3

10

1

5

(–)

(+)

2 20

Application Considerations of Bulletin 700-SK Connection For DC load switching, Bulletin 700-SK SSR will operate properly if the load is connected to either the positive or negative SSR load terminal. The load can be connected to either positive or negative output terminals of the SSR.

Protective Element (to extend SSR life) Since the SSR does not incorporate a surge absorption component, be sure to connect a surge absorption component when using the SSR to control an inductive load. For additional details applying solid-state relays, refer to pub. 700-AT001A*, Solid-State Relay Application Guide.

Rockwell Automation Publication 700-TD552A-EN-P

127

Page 128

Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited.

Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/.

Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400

Publication 700-TD552A-EN-P - September 2014 Copyright © 2014 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.