The text of a spec sheet · part 12 of 13
Relays and Timers Specifications, Bulletin Number 700, pages 111 to 120
Pages 111 to 120 of 128
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 700-HN122
Page 111
Relays and Timer Specifications
700-SC Solid State Relays
Control/Input Ratings
Cat. No.
Rated Control Voltage
Max. Operating Control Voltage Range
Max. Reverse Control Voltage [V]
Control Voltage Levels Impedance
Pick-up Voltage
700-SCZY3Z25
5…24V DC
4…28V DC
-28.8
15 mA max.
4V DC max.
1V DC min.
700-SCZY2A1
100/110V AC
75…125V AC
NA
41 kΩ± 20%
75V AC max.
20V AC min. 40V AC min.
700-SCZY2A2
200/220V AC
150…250V AC
NA
72 kΩ± 20%
150V AC max.
700-SCTY3Z24
24V DC
19.2…28.8V DC
-28.8
2 kΩ± 20%
19.2V DC max.
700-SCNY3Z25
5…24V DC
4…28V DC
-28
1.5 kΩ +20%/ -10% ‡
4V DC max.
700-SCZN3Z26
4…24V DC
3…28V DC
-28.8
15 mA max.
3V DC max.
700-SCTN3Z24
24V DC
19.2…28.8V DC
-28.8
2 kΩ± 20%
19.2V DC max.
700-SCNN3Z26
4…24V DC
700-SCNN2Z25
5…24V DC
1.5 kΩ +20%/ -10% ‡
3V DC max.
-28
3…28V DC
-28.8
Drop-out Voltage
1V DC min.
Load/Output Ratings
Cat. No.
Rated Control Voltage
Max. Load Voltage Range
100…240V AC
75…264V AC
Continuous Load Current (Resistive) [A] Min.
Max.♣
0.1
3
Max. Inrush Current§
700-SCZY3Z25 700-SCTY3Z24 700-SCZN3Z26 700-SCTN3Z24
45 A (@50/60 Hz, 1 cycle)
700-SCZY2A1 700-SCZY2A2 700-SCNN3Z26
2
4…48V DC
3…52.8V DC
0.1
3
18 A (10 ms)
5…110V DC
3…125V DC
0.1
2
10 A (10 ms)
700-SCNY3Z25 700-SCNN2Z25
0.1
With constant current input circuit system. SSR impedance varies with a change in input (control) voltage. ‡ Input impedance attains its maximum at the operating voltage. § If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to “Inrush Current Resistivity” graphs on page 9-177 for details. ♣ Refer to the following “Load Current Versus Ambient Temperature Characteristics” graphs on page page 9-177 for additional load current details.
Characteristics Description
Cat. No. 700-SCZ…
Load Switching Method/Device
Pick-up time
Drop-out time
Cat. No. 700-SCT
Cat. Nos. 700-SCNY, 700SCNN3…
Triac 1/2 of load power source cycle time Δ+ 1 ms max. (DC input) 3/2 of load power source cycle time Δ+ 1 ms max. (AC input)
Cat. Nos. 700-SCNN2…
Transistor
1 ms max
1/2 of load power source cycle timeΔ + 1 ms max. (DC input) 1/2 of load power source cycle timeΔ + 1 ms max 3/2 of load power source cycle timeΔ + 1 ms max. (AC input)
0.5 ms max.
0.5 ms max.
2 ms max.
2.5 ms max.
Output On Voltage Drop
1.6 V (RMS) max.
1.6 V (RMS)
1.5 V max.
1.5 V max.
Output Leakage Current
5 mA max (@ 100 V AC) 10 mA max (@ 200 V AC)
2.5 mA max (@ 100 V AC) 5 mA max (at 200 V AC)
5 mA max (@ 50 V DC)
0.1 mA max (@ 100 V DC)
Output VDRM, VCEO (V)
600
600
80
80
Output di/dt (A/uS)
50
50, - Output dv/dt (V/uS)
250
250, - Output I2t (A2S)
18
18, - Output Tj (°C) Max.
125
125
150
150
Insulation Resistance
100 MΩ min (@500V DC)
Dielectric Strength
1500V AC, 50/60 Hz for 1 minute
Vibration Resistance (max.)
10…55 Hz, 1.5 mm double amplitude (10 G)
Shock Resistance (max.)
1000 m/s2 (100 G)
Ambient Temperature
Operating: -30…+80 °C (-22...+176 °F) with no icing or condensation Storage: -30…+100 °C (-22...+212 °F) with no icing or condensation
Standards Compliance
UL5 08, CSA C22.2 No. 14, EN/IEC 60950, EN 50011, EN 61000-6-2, EN/IEC 60947-1, -4-3
Certifications cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified
Ambient Humidity
Operating: 45…85% (no condensation)
Weight
Approx. 50 g
Δ 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time = 20 ms
Rockwell Automation Publication 700-TD552A-EN-P
111
Page 112
700-SC Solid State Relays
Relays and Timer Specifications
Load Current Versus Ambient Temperature Characteristics
700-SC_ _2... 5
4
4
Ambient Temperature [° C] Inrush Current 700-SCNN3... 700-SCZ.... 700-SCT...
100
80
700-SCNN2...
Energizing Time [ms]
10 8 6 4
5000
3000
1000
300 500
100
0
20 30 50
2
10
2000
Inrush Current [A. Peak]
Energizing Time [ms]
1000
5000
500
1000
200
10
0
100
10
700-SCNY3
200 300 500
20
20 30 50 70 100
30
Ambient Temperature [° C]
12
10
Inrush Current [A. Peak]
40
30 50
Inrush Current [A. Peak]
50
30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0
60
60
20
100
0 80
0 40
1
0
1
40
2
20
2
3
0
3
-30 -20
Load Current [A]
5
-30 -20
Load Current [A]
700-SC_ _3...
Energizing Time [ms]
Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
EMC Directive Compliance 1. AC-switching models comply with EMC Directives under the following conditions 3 m max. Load Input
700-SC
Varistor: 470 V, 0.6 W Film capacitor: 1µ F, 250 VAC
Output
Varistor
Film capacitor
• Connect a varistor between the output terminals. • Connect a film capacitor to the load power supply. • The input cable must be less than 3 m.
2. DC-switching models comply with EMC Directives under the following conditions Less than 10 m Load Input
700-SC
Output
• The input cable must be less than 10 m.
112
Rockwell Automation Publication 700-TD552A-EN-P
Page 113
Relays and Timer Specifications
700-SC Solid State Relays
Approximate Dimensions All units in millimeters unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not intended for manufacturing purposes. Terminal Arrangement/ Internal Connections (Bottom View)
28 max.
1
4
5
8(+)
9
Load
Load
(+)
12(–) (–)
21.5 max.
13
36.5 max.
Input
14
–
42.5 max. –
Note:
Load power supply
+ Input voltage
+
The plus and minus symbols shown in parentheses are for DC loads.
Cat. No Bulletin 700-SC is compatible with Cat. Nos. 700-HN103, -HN104, and -HN128 socket.
Rockwell Automation Publication 700-TD552A-EN-P
113
Page 114
700-SC Solid State Relays
Relays and Timer Specifications
Basic Application Considerations For Bulletin 700-SC Connection For DC Load Switching, Bulletin 700-SC will operate properly if the load is connected to either the positive or negative SSR load terminal.
High-Density Mounting of Multiple SSRs If multiple relays are mounted side-by-side, be aware that the outer wall of each SSR works as a radiator. The SSR casing serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.
Protective Component When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has builtin surge suppression (Bulletins 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device. Select a varistor that meets the conditions of the load voltage outlined in the table below. Load Voltage [V AC]
Varistor Voltage [V]
100…120
240…270
200…240
440…470
380…480
820…1000
Varistor Surge Resistance 1000 A min.
For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load. Load Input
SSR
Load power supply
Note: For additional details when using Solid-State Relays, refer to pub. 700-AT001*, Solid-State Relay Application Guide.
114
Rockwell Automation Publication 700-TD552A-EN-P
Page 115
Relays and Timer Specifications
700-SF Solid State Relays
Specifications Control/Input Ratings
Cat. No.
Rated Control Voltage
Max. Operating Control Voltage Range [V DC]
Max. Reverse Control Voltage [V]
Control Voltage Levels Impedance
Pick-up Voltage
700-SFZY3Z25
5…24V DC
4…28V DC
–32
15 mA
4V DC max.
1V DC min.
700-SFTY3Z24
24V DC
19.2…28.8V DC
–28.8
2 kΩ ± 20%
19.2V DC max.
1V DC min.
700-SFNY3Z25
5…24V DC
4…28V DC
–28.8
1.5 kΩ + 20%/–10%‡
4V DC max.
1V DC min.
Drop-out Voltage
Load/Output Ratings Cat. No.
Rated Load Voltage
700-SFZY3Z25 700-SFTY3Z24 700-SFNY3Z25
Max. Load Voltage Range
100…240V AC
75…264V AC
4…48V DC
3…52.8V DC
Continuous Load Current (Resistive) [A] Min.
Max.♣
0.1
3
0.1
3
0.1
3
Max. Inrush Current§ 45 A @ 50/60 Hz, 1 cycle 18 A (10 ms)
Characteristics Description Load Switching Method/Device Pick-up Time Drop-out Time
Cat. No. 700-SFZY3Z25
Cat. No. 700-SFTY3Z24
Triac
Cat. No. 700-SFNY3Z25 Transistor
1/2 cycle of load power source cycle time Δ + 1 ms max.
0.5 ms max.
1 ms max.
1/2 cycle of load power source cycle timeΔ + 1 ms max.
2 ms max.
1.6V (RMS) max.
1.5V max.
Output ON Voltage Drop Output Leakage Current
5 mA max. (@ 100 V AC); 10 mA max. (@ 200 V AC)
2.5 mA max. (@ 100V AC); 5 mA max. (@ 200V AC)
5 mA max. (@ 50V DC)
Output VDRM, VCEO (V)
600
600
80
Output di/dt (A/uS)
50
50, Output dv/dt (V/uS)
250
250, 2
Output I t (A S)
18
18, Output Tj (°C) Max.
125
125
150
2
Insulation Resistance Dielectric Strength
100 MΩ min. (at 500V DC) 1,500V AC, 50/60 Hz for 1 min
Vibration Resistance (Max.)
10…55 Hz, 1.5 mm double amplitude (10 G)
Shock Resistance (Max.)
1000 m/s2 (100 G)
Ambient Temperature Ambient Humidity Standards Compliance Certifications Weight
Operating: –30…+80 °C (–22…+176 °F) with no icing or condensation Storage: –30…+100 °C (–22…=212 °F) with no icing or condensation 45…85% (no condensation) UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-3, EN/IEC 60950 cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified Approx. 50 g
With constant curent input circuit system, SSR impedance varies with a change in input voltage. ‡ Input impedance reaches its maximum at the operating voltage. § If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to the “Inrush Current Resistivity” graphs on page 9-181 for more details. ♣ Refer to “Load Current vs. Ambient Temperature Characteristics” on page 9-181 for additional load current details. Δ 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time 20 ms.
Rockwell Automation Publication 700-TD552A-EN-P
115
Page 116
700-SF Solid State Relays
Relays and Timer Specifications
Note: This data is non-repetitive. Keep the inrush current to half the rated value if it occurs repetitively. Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
Inrush Current
700-SFZ… 700SFT…
2000
500
Energizing Time [ms]
Energizing Time [ms]
Ambient Temperature [° C]
1000
5000
100
80
60
40
20
-20
-30
0
10
30 50
0
0
500
10
200 300
Inrush Current [A]
20
1000
1
30
200
2
40
100
3
30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 50 70 100
50
Inrush Current [A Peak]
Load Current [A]
4
20 30
700-SF…
Inrush Current 700-SFN…
10
Load Current vs. Ambient Temperature Characteristics
Inrush current resistivity is defined as the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
EMC Directive Compliance 1. AC-switching models comply with EMC Directives under the following conditions 3 m max. Load Input
700-SF
Varistor: 470 V, 0.6 W Film capacitor: 1µ F, 250 VAC
Output
Varistor
Film capacitor
• Connect a varistor between the output terminals. • Connect a film capacitor to the load power supply. • The input cable must be less than 3 m.
2. DC-switching models comply with EMC Directives under the following conditions Less than 10 m Load Input
700-SF
Output
• The input cable must be less than 10 m.
116
Rockwell Automation Publication 700-TD552A-EN-P
Page 117
Relays and Timer Specifications
700-SF Solid State Relays
Approximate Dimensions All units are in millimeters unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not intended for manufacturing purposes.
Terminal Arrangement/Input Connections (Bottom View)
28 max
1
2
3
4(+)
5
Load
6(-)
7
Input
8
Load
(+)
(-)
21.5 max
36.5 max 42.5 max
-
-
+
Input Voltage
+
Notes: 1. The plus and minus symbols shown in parentheses are for DC loads. 2. The coil has no polarity. Note: Bul. 700-SF is compatible with Cat. No. 700-HN116 socket.
Rockwell Automation Publication 700-TD552A-EN-P
117
Page 118
700-SF Solid State Relays
Relays and Timer Specifications
Basic Application Considerations of Bulletin 700-SF High Density Mounting of Multiple SSRs If multiple SSRs are mounted side-by-side, be aware that the outer case wall of the SSR acts as a radiator. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.
Connection For DC load switching, the Bul. 700-SF SSR will operate properly if the load is connected to either the positive or negative load terminals.
Protective Component To Extend SSR Life When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has builtin surge suppression (Bulletins 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device. Select a varistor that meets the conditions of the load voltage outlined in the table below. Load Voltage [V AC]
Varistor Voltage [V]
100…120
240…270
200…240
440…470
380…480
820…1000
Varistor Surge Resistance 1000 A min.
For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load. Load Input
SSR
Load power supply
Note: For additional details when using Solid-State Relays, refer to pub. 700-AT001*, Solid-State Relay Application Guide.
118
Rockwell Automation Publication 700-TD552A-EN-P
Page 119
Relays and Timer Specifications
700-SH Solid State Relays
Control/Input Ratings Cat. No. 700-SH10J…
700-SH_ _ H… 700-SH_ _ G…
Operating Voltage
Input Current @ Max. Voltage
Voltage Level Pickup Voltage
3…32V DC
12 mA
2.75V DC max.
1.2V DC min.
80…130V AC
13 mA
70V AC max.
30V AC
200...280V AC
13 mA
190V AC max.
90V AC min.
4…32V DC
12 mA
4V DC max.
1V DC min.
20…280V AC/22…48V DC
20 mA
18V AC/DC
6V AC/DC
3…32V DC
12 mA
2.5V DC
1.2V DC
20…280V AC/22…48V DC
20 mA
-32V DC
6V AC/DC
Drop-Out Voltage
4…32V DC
12 mA
3.5V DC
1.2V DC
20…280V AC/22…48V DC
20 mA
18V AC/DC
6V AC/DC
700-SH_ _ W…
Current Control
4…20 mA, - 700-SH_ _ F…
3…32V DC
12 mA
3V DC max.
1.0V DC
700-SH_ _ V…
When specified heatsink is used.
Output Ratings Cat. No.
Load Voltage Range
Applicable Load Current with Heat Sink [A]‡
700-SH5FZ24
3…60V DC
0.001…5 A DC
700-SH10J…
42…265V AC
0.15…10
700-SH10H…
42…530V AC
0.15…10
700-SH25G…
24…265V AC
0.15…25
700-SH25H…
42…530V AC
0.15…25
700-SH25V…
42…660V AC
0.15…25
700-SH25W…
90…280V AC
0.15…25
700-SH50G…
24…265V AC
0.15…50
700-SH50H…
42…530V AC
0.15…50
700-SH50V…
42…660V AC
0.15…50
700-SH50W…
90…280V AC
0.15…50
700-SH75H…
42…530V AC
0.15…75
700-SH75V…
42…660V AC
0.15…75
700-SH100H…
42…530V AC
0.15…100
700-SH100V…
42…660V AC
0.15…100
Cat. Nos. 700-SH10, 25, 50 (not including 700-SH_ _W)
Cat. Nos. 700-SH75, 100
‡ AC unless indicated.
Characteristics Description Pick-up Time
1/2 of load power source cycle time(DC input) 1 of load power source cycle time (AC input)
Drop-out Time
1/2 of load power source cycle time (DC input) 2 of load power source cycle time (AC input)
Output ON Voltage Drop
1.6V (RMS) max.
Output Leakage Current
<3 mArms 100 MΩ min (@ 500V DC)
Insulation Resistance
100 MΩ min. (at 500V DC)
Dielectric Strength
>4000 VACrms
Vibration Resistance
Malfunction: 10…55 Hz, 1.5 mm double amplitude Malfunction: 1000 m/s2
Shock Resistance Ambient Temperature
Operating: –20…+70 °C with no icing or condensation Storage: –40…+100 °C with no icing or condensation
Ambient Humidity
0…95% no condensing
Standards Compliance
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN 61000-6-4
Certifications cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 240924)
Weight
Approx. 60 g
Rockwell Automation Publication 700-TD552A-EN-P
Approx. 100 g
119
Page 120
700-SH Solid State Relays
Relays and Timer Specifications
Characteristics Description
Cat. No. 700-SH_ _W
Pick-up Current
4.2 mA
Drop-out Current
4.1 mA
Voltage Drop
<10V DC @ 20 mA
Leakage Current
<3 mA
Insulation Voltage
<4000 Vrms
Vibration Resistance
Malfunction: 10…55 Hz, 1.5 mm double amplitude
Shock Resistance
Malfunction: 1000 m/s2
Ambient Temperature
Operating: –20…+70 °C with no icing or condensation
Ambient Humidity
0…95% no condensing
Standards Compliance
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN 61000-6-4
Certifications cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 24024)
Weight
Approx. 60 g
Description
Cat. No. 700-SH5FZ24
Pick-up Voltage
<3V DC
Drop-out Voltage
>1V DC
Activating Frequency
<100 Hz
Input Impedance
1kΩ
Response Time Pick-up @ Vin > 5V
<4000 uS
Response Time Drop-out
<1 mS
On-state Voltage Drop @ Rated Current
<1.5V
Off-state Current Drop @ Rated Voltage
<1 mA
Insulation Voltage
<1 mA
Vibration Resistance
Malfunction: 10…55 Hz, 1.5 mm double amplitude
Shock Resistance
Malfunction: 1,000 m/s2
Ambient Temperature
Operating: –20…+70 °C with no icing or condensation
Ambient Humidity
0…95% no condensing
Standards Compliance
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN61000-6-4
Certifications cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 240924)
Weight
Approx. 60 g
Surge Current vs. Ambient Temperature Characterstics
Surge current resistivity for 700-SH50.... 700A
300A
600A
250A
500A
Inrush current (Apk)
Inrush current (Apk)
Surge current resistivity for 700-SH10, 25.... 350A
200A
150A
400A
300A
100A
200A
50A
100A
0A 10ms
100ms
1000ms
10000m s
0A 10ms
Energizing time (ms)
120
100ms
1000ms
Energizing time (ms)
Rockwell Automation Publication 700-TD552A-EN-P
10000m s