The text of a spec sheet · part 8 of 13
Relays and Timers Specifications, Bulletin Number 700, pages 71 to 80
Pages 71 to 80 of 128
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 700-HN122
Page 71
Relays and Timer Specifications
700-HX Plug-in Timing Relay
Z Mode Output quantity can be adjusted by changing the cycle time set in the adjustment level to 1 and by changing the ON duty (%) set value. The set value shows the ON duty (%) and can be set to a value between 0 and 100 (%). When the cycle time is 0, the output will always be OFF. When the cycle time is not 0 and when ON duty has been set to 0 (%), the output will always be OFF. When ON duty has been set to 100 (%), the output will always be ON. Z mode: ON/OFF-duty Adjustable Repeat Cycle Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF.
Power Start signal
Basic Operation
* Gate
Power
Reset
** Start signal input
Timing ON duty (%)
ON duty setting (%) ON time 0
UP
Timing (cycle time)
Timing (cycle time)
Control Output Cycle time
Timing ON duty (%)
Output
Cycle time Timing diagram
* Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is enabled during timing.
ON duty setting (%) ON time DOWN
0
Output Mode S: Stop Watch (Timer resets when power comes ON) Power
Start signal
Gate/Reset
Timing diagram
9999
The signal starts and stops timing. The display is held and timing is continued if the reset or gate input is received during timing operation. The timer resets if the reset or gate input is received when the timing operation is stopped.
Basic Operation
Set time
Power
UP 0
Start signal input
Set time
Gate/Reset
Timing
DOWN 0
Output
*
Display (for elapsed time)
* RST flashes
Note: Output is instantaneous when setting is 0.
Output Mode T OFF: Twin Timer OFF start
Sustained Output Power
Start signal
Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF.
Basic Operation
* Gate
Reset Control Output
Power ** Start Signal Input Timing OFF
OFF Time UP Timing diagram
ON Time
Timing OFF
Timing ON
Output
0 OFF Time
DOWN
Timing ON
ON Time 0
* Normal output operation will not be possible if the ON/OFF set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing.
Gate not included on any mode of this Relay.
Rockwell Automation Publication 700-TD552A-EN-P
71
Page 72
700-HX Plug-in Timing Relay
Relays and Timer Specifications Output Mode T ON: Twin Timer ON start
Sustained Output
Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF.
Power
Start signal
Basic Operation * Gate
Power ** Start Signal Input
Reset Control Output
Timing ON
OFF Time UP
ON Time
Timing diagram
Timing OFF
Timing ON
Timing OFF
Output
0 OFF Time
DOWN
* Normal output operation will not be possible if the ON/OFF set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing.
ON Time 0
Output Mode TOFF-1: Flicker OFF start 2 (Timer does not reset when power comes ON) Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF.
Power
Start signal
Basic Operation
Gate
Power Reset
* Start signal input
Timing diagram
Control output OFF time UP ON time
Timing OFF
Timing ON
Timing OFF a b
Output (a + b = ON time)
* Start signal input is disabled during timing.
0
Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type).
OFF time DOWN ON time 0
Output Mode TON-1: Flicker ON start 2 (Timer does not reset when power comes ON) Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF.
Basic Operation Power
* Start signal input
Timing ON
Timing OFF
Timing ON a b
Output (a + b = OFF time)
* Start signal input is disabled during timing. Note: Normal output operation will not be possible if the set time is too short.
Gate not included on any mode of this Relay.
72
Rockwell Automation Publication 700-TD552A-EN-P
Page 73
Relays and Timer Specifications
700-HX Plug-in Timing Relay
Approximate Dimensions Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes.
48×48
7.5
14.3
63.7
44.8×44.8
60 min. 45 +0.6 −0 45 +0.6 −0 60 min. 15 min.
Cat. No. 700-HX… Panel Cutout
5.2 (13/64)
6.2 (15/64)
50 (1-63/64)
12.5 (1/2)
1.0 (0.04)
35.0 (1.38)
27.0 (1.06)
7.5 (0.3)
1000 (39-3/8) Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
Terminal Arrangement
Internal circuit Signal Reset
4
5
3
6 7
2 1
8
0V
(–)
(+)
Cat. No. 700-HX…
Rockwell Automation Publication 700-TD552A-EN-P
73
Page 74
700-HXM Plug-in Timing Relay
Relays and Timer Specifications
Bulletin 700-HXM, Preset Counter/Timing Relay General Timer Functions Operation Display 2 No. 1 Display
Indicator
Meaning
RST
Lit during reset using reset input or Reset Key.
OUT
Lit when control output is ON.
TOTAL
Lit when totalizing value is displayed.
Displays the present value or parameter type. When totalizing count is displayed, the leftmost four digits of the 8-digit totalizing count will be displayed (Zeros suppressed).
Operation Display 1
Displays the time unit when the timer function has been selected
Example No. 2 Display Displays set value or set value of the parameter. Displays the rightmost four digits of the count value when the 700-HXM is used as a totalizing counter (Zero suppressed).
5 h 30 min 123.4 s
Level Key
Displays the present value or parameter type. When totalizing count is displayed, the leftmost four digits of the 8-digit totalizing count will be displayed (Zeros suppressed).
74
Mode Key
Press this key to select parameters within each level.
Down Key
Each press of this key decreases values displayed on the No. 2 display. Hold down this key continuously to decrease values quickly. Also returns setting items.
Up/Reset Key
Each press of this key increases values displayed on the No. 2 display. Hold down this key continuously to increase values quickly. Also advances setting items. To reset the present value, press this key while the present value is displayed. If this key is pressed while the totalizing count value is displayed, the totalizing count value and the present value will be reset.
Rockwell Automation Publication 700-TD552A-EN-P
Page 75
Relays and Timer Specifications
700-HXM Plug-in Timing Relay
Specifications Electrical Ratings Pilot Duty Rating
NEMA B300
Rated Supply Voltage
24V DC
Operating Voltage Range
85…110% of rated supply voltage
Power Consumption
1.5 W max. (for max. DC load) (Inrush current: 15 A max.) 120V AC
Make Break
30 A
240V AC
15 A
120V AC
3A
240V AC
1.5 A
Hp at 120V AC
1/4 Hp
Hp at 240V AC
1/3 Hp Mechanical
Mounting Method
Flush mounting (Panel or door)
Terminal Screw Tightening Torque
0.5 N•m max.
Display
Seven-segment, negative transmissive LCD; time display (hr, min, s); CMW, OUT, RST, TOTAL Present value (red, 7 mm high characters); Set value (green, 3.4 mm high characters)
Digits
PV: Four digits SV: Four digits When total count value is displayed: eight digits (Zeros suppressed)
Memory Backup
Counter
EEPROM (non-volatile memory) (number of writes: 100 000 times) Maximum counting speed
30 Hz or 5
Counting range
-999…9,999
Input modes
Increment, decrement, individual, quadrature inputs
Output modes
N, F, C, or K
Time ranges
0.000…9.999 s, 0.00…99.99 s, 0.0…999.9 s, 0…9999 s, 0 min 00 s…99 min 59 s, 0.0…999.9 min, 0 h 00 min…99 h 59 min, 0.0…999.9 hr, 0 h…9999 hr
Timer
Inputs (OV input)
Control Output
Timer modes
Elapsed time (Up), remaining time (Down)
Output modes
A, B, D, E, F, or Z
Input signals
For Counter: CP1, CP2, and reset For Timer: Start, gate, and reset
Input method
No-voltage input (contact short-circuit and open input) Short-circuit (ON) impedance: 1 KΩ max. (Approx. 2 mA runoff current at 0Ω) Short-circuit (ON) residual voltage: 2V DC max. Open (OFF) impedance: 100 kΩ min. Applied voltage: 30V DC max.
Start, reset, gate
Minimum input signal width: 1 or 20 ms (selectable)
Power reset
Minimum power-opening time: 0.5 s SPDT contact output: 5 A at 250V AC/30V DC, resistive load (cos φ = 1)
Minimum Applied Load
10 mA at 5V DC (failure level: P, reference value)
Reset System
External, manual, and power supply resets (for timer in A, B, D, E, or Z modes)
Sensor Waiting Time
260 ms max. (Inputs cannot be received during sensor wait time if control outputs are turned OFF.)
The figures given for maximum counting speed are for incrementing or decrementing operation with a prescale value of x1. If prescaling is used and 5 kHz is set, the maximum counting speed will be reduced to about half. The non-prescaling maximum counting speed will also be reduced to about half when the up/down mode is selected. ‡ “700-HXM User Manual” pub. no. 700-UM001*
Rockwell Automation Publication 700-TD552A-EN-P
75
Page 76
700-HXM Plug-in Timing Relay
Relays and Timer Specifications Characteristics
Timer Function
Signal start: ±0.03% ±30 ms max. Power-ON start: ±0.03% ±50 ms max.
Insulation Resistance
100 mΩ min. (at 500V DC)
Dielectric Strength
1500V AC, 50/60 Hz for 1 min between output terminals and non-current-carrying metal parts 510V AC, 50/60 Hz for 1 min between current-carrying terminals (except output terminals) and non-current-carrying metal parts 1500V AC, 50/60 Hz for 1 min between output terminals and current-carrying terminals (except output terminals) 500V AC, 50/60 Hz for 1 min between communications terminals and current-carrying terminals (except output terminals) 1000V AC, 50/60 Hz for 1 min between contacts not located next to each other
Noise Immunity
Square-wave noise by noise simulator; ±480V (between power terminals), ±600 V (between input terminals)
Static Immunity
±8 kV (malfunction), ±15 kV (destruction)
Vibration Resistance
Malfunction
10…55 Hz with 0.35 mm single amplitude each in three directions for 10 min.
Shock Resistance
Malfunction
100 m/s2 (approx. 10 G), 3 times each in six directions
Mechanical
10 million operations
Electrical
100 000 operations min (3 A at 250V AC, resistive load)
Operating
-10…55 °C (with no icing or condensation)
Life Expectancy Ambient Temperature
Storage
-25…65 °C (with no icing or condensation)
Ambient humidity
25…85%
EMC
(EMI): Emission Enclosure: EN61326 Class A (EMS): EN61326 Immunity ESD:EN61000-4-2:4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference:EN61000-4-3:10 V/m (Amplitude-modulated, 80 MHz…1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) Immunity Conducted Disturbance:EN61000-4-6:3 V (0.15…80 MHz) (level 2) Immunity Burst:EN61000-4-4:2 kV power-line (level 3); 1 kV I/O signal-line (level 4); 1 kV communications-line (level 3) Immunity Surge:EN61000-4-5:1 kV between lines (power and output lines) (level 3); 2 kV between grounds (power and output lines) (level 3)
Enclosure Ratings
Panel surface: IP66 and NEMA Type 4 (indoors) Rear case: IP20 Terminal block: IP20
Weight
Approx. 80 g
Certifications cURus Recognized Component (File No. E14843, Guide NRNT2/NRNT8), CE Marked, C-Tick Marked
Standards
EN61010-1, EN 61326, UL 508, CSA C22.2 No. 14
76
Rockwell Automation Publication 700-TD552A-EN-P
Page 77
Relays and Timer Specifications
700-HXM Plug-in Timing Relay
Input/Output Modes and Count Values Up (Increment) Mode CP1: Count Input
Down (Decrement) Mode CP1: Count Input
CP2: Count Prohibit input
CP1
CP1
CP2
CP2
CP2: Count prohibit input
UP Count
Input edge
CP1: Count Input
CP2: Count prohibit input
CP1: Count input H CP1 L
CP1
H L
CP2
CP2
CP2: Count prohibit input
DOWN Count
Count
Up/Down C Quadrature
Up/Down B Individual Input CP1
CP1
CP2
CP2
Count
Count
Note: H = Short-circuited L = Open (A) indicates the minimum signal width and (B) requires at least 1/2 the minimum signal width. If these conditions are not met, a counting error (+1 or -1) may occur.
Rockwell Automation Publication 700-TD552A-EN-P
77
Page 78
700-HXM Plug-in Timing Relay
Relays and Timer Specifications
Input/Output Mode Settings Counter Function If there is a power failure during output ON, output will turn ON again when the power supply has recovered. For one-shot output, an output will be made again for the duration of the output time setting once the power supply has resumed. Output timing restarted during one-shot outputs is ignored. Input Mode Up
Down
Up/Down B.C
Reset 9999 SV
N 0 -999 Output
Reset 9999 SV
F 0 -999 Output
Output mode
Reset 9999 SV
C 0 -999 t t t t t-a t t t-a t
Output Reset 9999 SV
K 0 -999 t-a t t-a t-a t t-a t
Output
Note: t-a: Less than the output time t: Output time
Totalizing Counter Operation Reset Totalizing Count Reset (Reset Key) PV
Totalizing counter continues to count the present value, regardless of whether an reset input (by the reset key) has been made to reset the PV. When totalizing count value has reset, the PV is reset at the same time. The totalizing count range is 0…99999999. If the totalizing count exceeds 99999999, the count returns to 0. If the count drops below 0, it becomes 99999999.
Totalizing Count Value
78
Rockwell Automation Publication 700-TD552A-EN-P
Page 79
Relays and Timer Specifications
700-HXM Plug-in Timing Relay
Timer Function A Mode: Signal
B Mode: Repeat Power supply
Start
Start
Gate
Gate
Reset Control output SV Up 0 SV Down 0
Reset Control output SV Up 0 SV Down 0
Time display
Time display
Power supply
D Mode: Signal OFF-Delay
E Mode: One Shot Power supply
Start
Start
Gate
Gate
Reset Control output SV Up 0 SV Down 0
Reset Control output SV Up 0 SV Down 0
Time display
Time display
Power supply
F Mode: Accumulative
Z Mode: ON/OFF-Duty Adjustable Repeat Cycle Power supply
Power supply
Start
Start
Gate
Time display
Time display
Gate Reset Control output SV Up 0 SV Down 0
Reset Control output Cycle time ON duty setting (%) ON time Up 0 Cycle time ON duty setting (%) ON time Down 0
Z Mode Output quantity can be adjusted by changing the cycle time set in the adjustment level to 1 and by changing the ON duty (%) set value. The set value shows the ON duty (%) and can be set to a value between 0 and 100 (%). When the cycle time is 0, the output will always be OFF. When the cycle time is not 0 and when ON duty has been set to 0 (%), the output will always be OFF. When ON duty has been set to 100 (%), the output will always be ON. Cycle time ON duty (%)
Cycle time
One-shot output or HOLD output can be selected for output:
Rockwell Automation Publication 700-TD552A-EN-P
79
Page 80
700-HXM Plug-in Timing Relay
Relays and Timer Specifications
Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes.
Cat. No. 700-HXM…
Terminal Arrangement RS-485
Not Not Connected connected
Output Output
Out
CP1/ Start
24-VDC 24V DC power supply power supply
CP2/ Gate
Reset Reset
Contact inputs Contact Inputs
Open-collector inputs Open-collector inputs Cat. No. 700-HXM…
80
Rockwell Automation Publication 700-TD552A-EN-P