The text of a spec sheet · part 24 of 25

Relay and Timer Specifications, Bulletin Number 700, pages 231 to 240

Pages 231 to 240 of 250

The original document is the PDF (23 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 700-HA33Z24, Allen-Bradley 700-HN153, Allen-Bradley 700-HA32Z24 and Allen-Bradley 700-HX

Page 231

Solid-State Relays

Dimensions - 700-SC Relays All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for manufacturing purposes. Terminal Arrangement/ Internal Connections (Bottom View)

28 max.

1

4

5

8(+) Load

9

Load

(+)

12(–) (–)

21.5 max.

13

36.5 max.

Input

14

–

42.5 max. –

Note:

Load power supply

+ Input voltage

+

The plus and minus symbols shown in parentheses are for DC loads.

Cat. No 700-SC… (1) (1)

700-SC is compatible with Cat. Nos. 700-HN103, -HN104, and -HN128 socket.

Basic Application Considerations for 700-SC High-density Mounting of Multiple Solid-state Relays (SSRs) If multiple relays are mounted side by side, the outer wall of each SSR works as a radiator. The SSR casing serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.

Connection For DC Load Switching, 700-SC will operate properly if the load is connected to either the positive or negative SSR load terminal.

Protective Component When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in surge suppression (s 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device. Select a varistor that meets the conditions of the load voltage that is outlined in the table below. Load Voltage [V AC]

Varistor Voltage [V]

100…120

240…270

200…240

440…470

380…480

820…1000

TIP

Varistor Surge Resistance

1000 A min.

For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.

Load Input

230

SSR

Load power supply

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 232

Solid-State Relays

700-SF Square Base Relays • 3 A (resistive) max. continuous load (output) current • 264V AC or 52.8V DC max. load voltage options • 4…24V DC control/input voltage • Photocoupler or phototriac isolation option between control and output voltage • LED Indicator for input/logic ON/OFF status monitoring 700-HN116 socket compatible

•

Input-to-Output Isolation Method

Zero Cross Function

Photocoupler

Yes

Phototriac

No

Photocoupler

Not Applicable

Status Indicator

Yes

Output (Load) Max. Continuous Current and Rated Voltage Range

Rated Input Control Voltage

Cat. No.

3 A @ 100…240V AC (47...63 Hz)

5…24V DC

700-SFZY3Z25

24V DC

700-SFTY3Z24

3 A @ 4…48V DC

4…24V DC

700-SFNY3Z25

Accessories-700-SF Relays Photo

(1)

Description

Pkg. Quantity

Cat. No.

Screw Terminal Socket, Panel or DIN Rail Mounting 8-blade miniature socket for use with DPDT HF relays.

10

700-HN116

DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m

10

199-DR1

Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N40

Blank Identification Tags, contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N41

Retainer Clip for Cat. Nos. 700-HN103, -HN104, and -HN128 Sockets with 700-HC Relays. Secures relay in socket.

10

700-HN114(1)

700-SF must use Cat. No. 700-HN114 series B retainer clip.

Specifications- 700-FS Relays Control/Input Ratings Cat. No.

Rated Control Voltage

Max. Operating Control Voltage Range [V DC]

Max. Reverse Control Voltage [V]

Impedance

700-SFZY3Z25

5…24V DC

4…28V DC

–32

700-SFTY3Z24

24V DC

19.2…28.8V DC

700-SFNY3Z25

5…24V DC

4…28V DC

Control Voltage Levels Pick-up Voltage

Drop-out Voltage

15 mA max. (1)

4V DC max.

1V DC min.

–28.8

2 kΩ ± 20%

19.2V DC max.

1V DC min.

–28.8

1.5 kΩ + 20%/– 10% (2)

4V DC max.

1V DC min.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

231

Page 233

Solid-State Relays

Load/Output Ratings Cat. No.

Rated Control Voltage

Max. Load Voltage Range

Continuous Load Current (Resistive) [A]

700-SFZY3Z25

100…240V AC

75…264V AC

4…48V DC

3…52.8V DC

700-SFTY3Z24 700-SFNY3Z25

Max. Inrush Current (4)

Min.

Max. (3)

0.1

3

0.1

3

45 A @ 50/60 Hz, 1 cycle

0.1

3

18 A (10 ms)

Characteristics Description Load Switching Method/Device

Output VDRM, VCEO (V)

Cat. No. 700-SFZY3Z25 Cat. No. 700-SFTY3Z24 Triac Transistor 1/2 cycle of load power source 1 ms max. cycle time (5) + 1 ms max. 1/2 cycle of load power source cycle time (5) + 1 ms max. 1.6V (RMS) max. 5 mA max. (@ 100V AC); 2.5 mA max. (@ 100V AC); 5 mA max. (@ 200V AC) 10 mA max. (@ 200V AC) 600 600

Output di/dt (A/uS) Output dv/dt (V/uS) Output I2t (A2S)

50 250 18

50 250 18, - - Output Tj (°C) Max. Insulation Resistance Dielectric Strength Vibration Resistance (Max.) Shock Resistance (Max.)

125 100 MΩ min. (at 500V DC) 1,500V AC, 50/60 Hz for 1 min 10…55 Hz, 1.5 mm double amplitude (10 G) 1000 m/s2 (100 G)

125

150

Ambient Temperature

Operating: –30…+80 °C (–22…+176 °F) with no icing or condensation Storage: –30…+100 °C (–22…=212 °F) with no icing or condensation

Ambient Humidity Standards Compliance Certifications Weight

45…85% (no condensation) UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-3, EN/IEC 60950 cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified Approx. 50 g

Pick-up Time Drop-out Time Output ON Voltage Drop Output Leakage Current

Cat. No. 700-SFNY3Z25 0.5 ms max. 2 ms max. 1.5V max. 5 mA max. (@ 50V DC) 80

(1) With constant current input circuit system, SSR impedance varies with a change in input voltage. (2) (3) (4) (5)

Input impedance reaches its maximum at the operating voltage. If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See the “Inrush Current Resistivity” graphs on page 116 for more details. See “Load Current vs. Ambient Temperature Characteristics” on page 116 for additional load current details. 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time 20 ms.

IMPORTANT

232

This data is non-repetitive. Keep the inrush current to half the rated value if it occurs repetitively. Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 234

Solid-State Relays

Inrush Current Resistivity (1)

Inrush Current Resistivity (1)

700-SFZ… 700SFT…

700-SFN…

Ambient Temperature [° C]

2000

1000

500

200 300

5000

1000

10

100

80

60

40

20

-30

-20

0

0

0

500

10

50 70 100

Inrush Current [A]

20

200

1

30

100

2

40

30 50

3

30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 20 30

50

Inrush Current [A Peak]

Load Current [A]

4

10

Load Current vs. Ambient Temperature Characteristics 700-SF

Energizing Time [ms]

Energizing Time [ms]

(1) Inrush current resistivity is defined as the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.

EMC Directive Compliance 1. AC-switching models comply with EMC Directives under the following conditions 3 m max. Load Input

700-SF

Varistor: 470 V, 0.6 W Film capacitor: 1µ F, 250 VAC

Output

Varistor

Film capacitor

• Connect a varistor between the output terminals. • Connect a film capacitor to the load power supply. • The input cable must be less than 3 m.

2. DC-switching models comply with EMC Directives under the following conditions Less than 10 m Load Input

700-SF

Output

• The input cable must be less than 10 m.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

233

Page 235

Solid-State Relays

Dimensions - 700-SF Relays All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for manufacturing purposes.

Terminal Arrangement/Input Connections (Bottom View)

28 max

1

2

3

4(+)

5

Load

6(-)

7

Input

8

Load

(+)

(-)

-

36.5 max 42.5 max

21.5 max

-

+

Input Voltage

+

Notes: 1. The plus and minus symbols shown in parentheses are for DC loads. 2. The coil has no polarity.

IMPORTANT

700-SF is compatible with Cat. No. 700-HN116 socket.

Basic Application Considerations of 700-SF High-density Mounting of Multiple Solid-state Relays (SSRs) If multiple SSRs are mounted side by side, the outer case wall of the SSR acts as a radiator. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.

Connection For DC load switching, the Bul. 700-SF SSR will operate properly if the load is connected to either the positive or negative load terminals.

Protective Component to Extend SSR Life When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in surge suppression (700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device. Select a varistor that meets the conditions of the load voltage that is outlined in the table. Load Voltage [V AC]

Varistor Voltage [V]

100…120

240…270

200…240

440…470

380…480

820…1000

TIP

Varistor Surge Resistance

1000 A min.

For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.

For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load.

Load Input

234

SSR

Load power supply

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 236

Solid-State Relays

700-SH Hockey Puck Relays • 100 A max. continuous load (output) current with appropriate heat sink • 264V AC, 530V AC, or 660V AC max. load voltage options • 3…32V DC, 4…32V DC, 80…130V AC, 200…260V AC, 20…280V AC/22…48V DC control (input) voltage options • LED indicator for input/logic ON/OFF status monitoring • Protective cover for added safety

Photo

Input-toOutput Isolation Method

Zero Cross Function

Yes

Status Indicator

Yes

Output (Load) Max. Continuous Current and Rated Voltage Range (1)

Rated Input Control Voltage

Cat. No.(2)

10 A @ 42…265V AC

3…32V DC

700-SH10JZ24

10 A @ 42…265V AC

80…130V AC

700-SH10JA12

10 A @ 42…265V AC

200…260V AC

700-SH10JA22

10 A @ 42…530V AC

4…32V DC

700-SH10HZ25 (Series B)

25 A @ 42…530V AC

4…32V DC

700-SH25HZ25 (Series B)

25 A @ 24…265V AC

3…32V DC

700-SH25GZ24

25 A @ 24…265V AC

20…280V AC/ 22…48V DC

700-SH25GA24

50 A @ 24…265V AC

3…32V DC

700-SH50GZ24

50 A @ 24…265V AC

20…280V AC/ 22…48V DC

700-SH50GA24

50 A @ 42…530V AC

4…32V DC

700-SH50HZ25

25 A @ 42…660V AC

4…32V DC

700-SH25VZ25

25 A @ 42…660V AC

20…280V AC/ 22…48V DC

700-SH25VA24

50 A @ 42…660V AC

4…32V DC

700-SH50VZ25

50 A @ 42…660V AC

20…280V AC/ 22…48V DC

700-SH50VA24

75 A @ 42…530V AC

4…32V DC

700-SH75HZ25

75 A @ 42…660V AC

4…32V DC

700-SH75VZ25

75 A @ 42…530V AC

20…280V AC/ 22…48V DC

700-SH75HA24

75 A @ 42…660V AC

20…280V AC/ 22…48V DC

700-SH75VA24

100 A @ 42…530V AC

4…32V DC

700-SH100HZ25

100 A @ 42…530V AC

20…280V AC/ 22…48V DC

700-SH100HA24

100 A @ 42…660V AC

4…32V DC

700-SH100VZ25

100 A @ 42…660V AC

20…280V AC/ 22…48V DC

700-SH100VA24

5 A @ 3...60V DC

3…32V DC

700-SH5FZ24

25 A @ 90…280V AC

4…20 mA DC

700-SH25WA25

50 A @ 90…280V AC

4…20 mA DC

700-SH50WA25

Optocoupler

Yes

No

Yes

Yes

(1) When used with heat sink. (2) All catalog numbers are Series A unless noted.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

235

Page 237

Solid-State Relays

Accessories - 700-SH Relays Photo

236

Description

Pkg. Quantity

Cat. No.

Heat Sink - Panel or DIN Rail Mount

1

700-SN10

Heat Sink - Panel or DIN Rail Mount

1

700-SN25

Heat Sink - Panel or DIN Rail Mount

1

700-SN50

Heat Sink - Panel or DIN Rail Mount

1

700-SN50HC

Heat Sink - Panel or DIN Rail Mount

1

700-SN50VHC

DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m

10

199-DR1

Thermal Conductive Pads

50

700-SHCPAD

Plastic Covers, for DC output version

25

700-SHCOV

Thermal Adapters - for 100 A Wire

10

700-SHTRMA

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 238

Solid-State Relays

Specifications- 700-SH Relays Control/Input Ratings Cat. No.

Operating Voltage

Input Current @ Max. Voltage

Voltage Level Pickup Voltage

Drop-out Voltage

3…32V DC

12 mA

2.75V DC max.

1.2V DC min.

80…130V AC

13 mA

70V AC max.

30V AC min. (1)

200...280V AC

13 mA

190V AC max.

90V AC min.

4…32V DC

12 mA

4V DC max.

1V DC min.

20…280V AC/22…48V DC

20 mA

18V AC/DC

6V AC/DC

3…32V DC

12 mA

2.5V DC

1.2V DC

20…280V AC/22…48V DC

20 mA

-32V DC

6V AC/DC

4…32V DC

12 mA

3.5V DC

1.2V DC

20…280V AC/22…48V DC

20 mA

18V AC/DC

6V AC/DC

700-SH_ _ W…

Current Control

4…20 mA, - 700-SH_ _ F…

3…32V DC

12 mA

3V DC max.

1.0V DC

700-SH10J…

700-SH_ _ H…

700-SH_ _ G…

700-SH_ _ V…

(1) When specified heatsink is used.

Output Ratings Load Voltage Range

Applicable Load Current with Heat Sink [A] (2)

700-SH5FZ24

3…60V DC

0.001…5 A DC

700-SH10J…

42…265V AC

0.15…10

700-SH10H…

42…530V AC

0.15…10

700-SH25G…

24…265V AC

0.15…25

700-SH25H…

42…530V AC

0.15…25

700-SH25V…

42…660V AC

0.15…25

700-SH25W…

90…280V AC

0.15…25

700-SH50G…

24…265V AC

0.15…50

700-SH50H…

42…530V AC

0.15…50

700-SH50V…

42…660V AC

0.15…50

700-SH50W…

90…280V AC

0.15…50

700-SH75H…

42…530V AC

0.15…75

700-SH75V…

42…660V AC

0.15…75

700-SH100H…

42…530V AC

0.15…100

700-SH100V…

42…660V AC

0.15…100

Cat. No.

(2) AC unless indicated.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

237

Page 239

Solid-State Relays

Characteristics Description

Cat. Nos. 700-SH10, 25, 50 (not including 700-SH_ _W)

Cat. Nos. 700-SH75, 100

Pick-up Time

1/2 of load power source cycle time(DC input) / 1 of load power source cycle time (AC input)

Drop-out Time

1/2 of load power source cycle time (DC input) / 2 of load power source cycle time (AC input)

Output ON Voltage Drop

1.6V (RMS) max.

Output Leakage Current

<3 mARMS 100 MΩ min (@ 500V DC)

Insulation Resistance

100 MΩ min. (at 500V DC)

Dielectric Strength

>4000V ACRMS

Vibration Resistance

Malfunction: 10…55 Hz, 1.5 mm double amplitude

Shock Resistance

Malfunction: 1000 m/s2 Operating: –20…+70 °C with no icing or condensation

Ambient Temperature Storage: –40…+100 °C with no icing or condensation Ambient Humidity

0…95% no condensing

Standards Compliance

UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN 61000-6-4

Certifications cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 240924)

Weight

Approx. 60 g

Description

Approx. 100 g

Cat. No. 700-SH_ _W

Pick-up Current

4.2 mA

Drop-out Current

4.1 mA

Voltage Drop

<10V DC @ 20 mA

Leakage Current

<3 mA

Insulation Voltage

<4000 VRMS

Vibration Resistance

Malfunction: 10…55 Hz, 1.5 mm double amplitude

Shock Resistance

Malfunction: 1000 m/s2

Ambient Temperature

Operating: –20…+70 °C with no icing or condensation

Ambient Humidity

0…95% no condensing

Standards Compliance

UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN 61000-6-4

Certifications cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 24024)

Weight

Approx. 60 g

Description

Cat. No. 700-SH5FZ24

Pick-up Voltage

<3V DC

Drop-out Voltage

>1V DC

Activating Frequency

<100 Hz

Input Impedance

1 kΩ

Response Time Pick-up @ Vin > 5V

<4000 uS

Response Time Drop-out

<1 mS

On-state Voltage Drop @ Rated Current

<1.5V

238

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 240

Solid-State Relays

Description

Cat. No. 700-SH5FZ24

Off-state Current Drop @ Rated Voltage

<1 mA

Insulation Voltage

<1 mA

Vibration Resistance

Malfunction: 10…55 Hz, 1.5 mm double amplitude

Shock Resistance

Malfunction: 1,000 m/s2

Ambient Temperature

Operating: –20…+70 °C with no icing or condensation

Ambient Humidity

0…95% no condensing

Standards Compliance

UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN61000-6-4 cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 240924)

Certifications Weight

Approx. 60 g

Surge Current vs. Ambient Temperature Characteristics Surge current resistivity for 700-SH50....

Surge current resistivity for 700-SH10, 25.... 700A

300A

600A

250A

500A

Inrush current (Apk)

Inrush current (Apk)

350A

200A

150A

100A

400A

300A

200A

50A

100A

0A 10ms

100ms

1000ms

0A 10ms

10000m s

Energizing time (ms)

100ms

1000ms

10000m s

Energizing time (ms)

Surge current resistivity for 700-SH75....

Surge current resistivity for 700SH100....

1200A

2000A 1800A 1000A

1600A 1400A

Inrush current (Apk)

Inrush current (Apk)

800A

600A

400A

1200A 1000A 800A 600A

200A

400A 200A

0A 10ms

100ms

1000ms

Energizing time (ms)

10000m s

0A 10ms

100ms

1000ms

10000m s

Energizing time (ms)

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

239