Spec sheet · Allen-Bradley
Relay and Timer Specifications, Bulletin Number 700
Spec sheet250 pagesPDF 23 MB
Technical data for Allen-Bradley Bulletin 700 relays and timers, from the 700-HA and 700-CF relays to the 700-HX digital timing relay.
Names · 4 models
The models it names
Allen-Bradley 700-HA33Z24Control relay from$29.951 in stock
Allen-Bradley 700-HA32Z24Control relay Call for availability
Allen-Bradley 700-HXControl relay Call for availability Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
Rockwell Automation technical data for the Bulletin 700 relay and timer line. It opens with contact data tables, NEMA ratings and surge suppression, then gives selection, accessories, specifications and dimensions for general purpose relays such as the 700-HA tube base relay, electronic timers such as the 700-HX multi-function digital timing relay, NEMA industrial relays, IEC control relays such as the 700-CF, and solid-state relays. Socket and retainer clip numbers are listed for each relay.
Its parts
- General Information
- General Purpose Relays
- General Purpose Electronic Timers and Counters
- NEMA Industrial Relays
- IEC Control Relays
- Solid-state Relays
From the sheet
Key facts from this sheet
Each line names its page in the PDF.
Rockwell Automation technical data (publication 700-TD552B-EN-P, August 2018) for the whole Bulletin 700 line of relays and timers, among them the 700-HA tube base relays, 700-HB square base relays, 700-HX digital timing relay and 700-CF control relays. It gives ordering numbers, sockets, accessories and specifications so a reader can pick or replace a relay and the parts that go with it.
- Document
- Rockwell Automation technical data on Bulletin 700 relays and timers, publication 700-TD552B-EN-P, August 2018 p. 1, 2
- 700-HX timer
- 700-HX: digital timing relay with LCD display, SPDT output, 5 A at 250V AC resistive, B300 p. 139, 142
- 700-HA relay
- 700-HA: tube base relay, DPDT or 3PDT, 10 A, B300, single AgNi contact, pin terminals p. 12
- 700-HN153 socket
- 700-HN153: 11-blade screw terminal socket for 700-HB relays, panel or DIN rail, takes plug-in modules; retainer clip 700-HN158 p. 24
- 700-HX versions
- 700-HX86SA17: 100…240V AC input; 700-HX86SU24: 24V AC or 12…24V DC input; both 8-pin p. 139
- 700-HX supply
- 700-HX: 100 to 240V AC, or 24V AC/12 to 24V DC; works at 85…110% of rated supply p. 142
- 700-HA sockets
- 700-HA32: 8-pin 700-HN100, 700-HN125, 700-HN204; 700-HA33: 11-pin 700-HN101, 700-HN126, 700-HN205 p. 15, 16
- 700-HX sockets
- 700-HX: 8-pin 700-HN100 (retainer clip 700-HN131) or 700-HN125 (no clip); 700-HN108 backwired solder socket p. 139, 140
- 700-HX display
- 700-HX: four-digit LCD, present value red 12 mm, set value green 6 mm p. 142
- 700-HX time ranges
- 700-HX: from 0.000…9.999 s up to 0 hr…9999 hr p. 142
- 700-HX memory
- 700-HX: no battery; settings stored 10 years min. p. 139, 142
- 700-HX environment
- 700-HX: -10 to +55 °C ambient, 25 % to 85 % humidity, approx. 100 g p. 143
- 700-HA coil and timing
- 700-HA: DC coil 1.3 W; max pickup and dropout 10 ms; operating –40…+70 °C p. 16
- 700-HX accessories
- 700-HX: frame adapter 700-HN130 for flush or door mounting; protective cover 700-HN132 p. 140
What this sheet walks you through
- Choosing a 700-HA relay by contact type, poles and coil voltage p. 12, 13
- Adding LED, push-to-test and manual override options to a 700-HA relay p. 12
- Picking sockets, surge suppressors and timing modules for 700-HA relays p. 14, 15
- Setting the ranges and modes of the 700-HT3 time module p. 17
- Selecting 700-HB square base relays, sockets and retainer clips p. 22, 24
- Reading the 700-HX display and using its keys p. 141
- 700-HX ratings, timing and environmental specifications p. 142, 143
- Comparing the 700-CF and 700-K IEC control relays p. 188
- Choosing a 700-CF control relay and its coil voltage code p. 189, 190
Good to know
- This edition removed the standard and standard diode DC coil voltage codes for 700-CF and 700S-CF relays. p. 2
- 700-HX: the attached waterproof packing is needed for IP66 sealing between the timer and the panel. p. 143
- 700-HA: the LED option is not available for 220V DC and 277V AC coils. p. 12
- 700-HX: avoid freezing or condensation; storage -25 to +65 °C. p. 143
- 700-HX: the contact output needs a minimum load of 10 mA at 5 V DC. p. 142
Questions this sheet answers
What socket fits the 700-HX timer?
The 8-pin 700-HN100 (with retainer clip 700-HN131) or the open style 700-HN125, which needs no clip. A 700-HN108 backwired solder socket is also listed. p. 139, 140
What supply voltage does the 700-HX86SU24 need?
24V AC or 12…24V DC. The 700-HX86SA17 takes 100…240V AC. p. 139
Which retainer clip goes with the 700-HN153 socket?
The 700-HN158 clip, sold in packs of 10, holds a 700-HB relay in the 700-HN153 socket. p. 24
What output modes does the 700-HX timing relay have?
A, A-1, A-2, A-3, B, B-1, D, E, F, Z, S, tOFF, tON, tOFF-1 and tON-1, counting elapsed or remaining time. p. 142
What is the contact rating of the 700-HA relay?
10 A for the standard 700-HA and 6 A for the bifurcated gold plated 700-HAX, at 120V and 240V. p. 16
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 25 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 101-10
- Pages 11 to 2011-20
- Pages 21 to 3021-30
- Pages 31 to 4031-40
- Pages 41 to 5041-50
- Pages 51 to 6051-60
- Pages 61 to 7061-70
- Pages 71 to 8071-80
- Pages 81 to 9081-90
- Pages 91 to 10091-100
- Pages 101 to 110101-110
- Pages 111 to 120111-120
- Pages 121 to 130121-130
- Pages 131 to 140131-140
- Pages 141 to 150141-150
- Pages 151 to 160151-160
- Pages 161 to 170161-170
- Pages 171 to 180171-180
- Pages 181 to 190181-190
- Pages 191 to 200191-200
- Pages 201 to 210201-210
- Pages 211 to 220211-220
- Pages 221 to 230221-230
- Pages 231 to 240231-240
- Pages 241 to 250241-250
The file