Page 191

IEC Industrial Relays

6- and 8-pole Relays Control Relays with Overlapping Side-Mounted Contacts AC-12

AC-15

Ith [A]

Ie [A] 40 60 24/ °C °C 48V

Main Relay

Side Contacts

190

20

10

20

10

10

6

Left Aux. 120 V

10

6

240 V

10

5

400 V

6

3

500 V

2.5

1.6

600 V

1

1

Relay Arrangement

Right Aux.

690 V

Contacts

Overlapping SideMounted Contacts

Cat. No.

N.O. N.C. N.O.

N.C.

4

0

1

1

700-CFZ1510⊗

3

1

1

1

700-CFZ1420⊗

2

2

1

1

700-CFZ1330⊗

4

0

2

2

700-CFZ2620⊗

3

1

2

2

700-CFZ2530⊗

2

2

2

2

700-CFZ2440⊗

1

1

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 192

IEC Industrial Relays

Control Relays with Standard Side-mounted Contacts AC-12

AC-15

Ith [A]

Ie [A]

Left Aux.

40 60 24/ °C °C 48V

Main Relay

20

20

Side Contacts 10

10

Relay Arrangement

Contacts

Right Aux.

120V 240V 400V 500V 600V 690V

10

10

6

10

6

6

5

2.5

3

1

1.6

1

1

1

Standard SideMounted Contacts

Cat. No. (1)

N.O.

N.C. N.O.

N.C.

4

0

1

1

700CFZ0510⊗

3

1

1

1

700CFZ0420⊗

2

2

1

1

700CFZ0330⊗

4

0

2

2

700CFZ0620⊗

3

1

2

2

700CFZ0530⊗

2

2

2

2

700CFZ0440⊗

(1) All Cat. Nos. are factory stocked.

⊗ AC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CFZ051⊗ becomes Cat. No. 700-CFZ0510F. [V]

12

24

32

36

42

48

100

100... 110

110

120

127

200

200... 220

208

208... 240

220... 230

230

230... 240

240

50 Hz

R

K

V

W

X

Y

KP, D

P

S

KG

L, - F, VA

T

60 Hz

Q

J, V, X, KP, D, - KG

H

L, - - A

50/60 Hz, KJ, - - KY

KP, KD, - KG

KL, - KL

KF, KA

[V]

277

347

380

380... 400

400

400... 415

440

480

500

550

600

50 Hz, - - N, G

B, M

C, 60 Hz

T

I

E, - - N

B, - C

50/60 Hz, - - - KN, KB, - - - Rockwell Automation Publication 700-TD552B-EN-P - August 2018

191

Page 193

IEC Industrial Relays

Assignment of Contacts Device Combinations in Accordance with IEC 60947-1 / -4-1 Auxiliary Contact Blocks Circuit Diagram

Control Relays 700-CF (AC and DC Control) Control

700-CF⊗220

700-CF⊗310

700-CF⊗400

AC/DC

22E + 02E = 24Y

31E + 02E = 33Y

40E + 02E = 42Y

AC/DC

22E + 11E = 33Y

31E + 11E = 42Y

40E + 11E = 51Y

AC/DC

22E + 20E = 42Y

31E + 20E = 51Y

40E + 20E = 60Y

AC/DC

22E + 22E = 44Y

31E + 22E = 53Y

40E + 22E = 62Y

AC/DC

22E + 31E = 53Y

31E + 31E = 62Y

40E + 31E = 71Y

AC/DC

22E + 40E = 62Y

31E + 40E = 71Y

40E + 40E = 80Y

AC/DC

22E + L22E = L44Y

31E + L22E = L53Y

40E + L22E = L62Y

FrontMounting (1) 51 61

100-FA02 52 62 53 61

100-FA11 54 62 53 63

100-FA20 54 64 53 61 71 83

100-FA22 54 62 72 84 53 61 73 83

100-FA31 54 62 74 84

100-FA40

53 63 73 83 54 64 74 84 53 61 75 87

100-FAL22 54 62 76 88

(1) Control relay and auxiliary contact block AC/DC max. 4 N. C.

192

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 194

IEC Industrial Relays

Auxiliary Contacts Photo

Description

N.O.

Auxiliary Contact Blocks for Front Mounting§ 2- and 4-pole Quick and easy mounting without tools Electronic-compatible contacts down to 17V, 5 mA Mechanically linked performance between N.O. and N.C. poles and to the main relay poles (except for L types) Models with equal function with several terminal numbering choices 1L = Late break N.C./early make N.O. Bifurcated version for switching down to 5V, 3 mA

N.C.

Connection Diagrams

For Use With

Standard Contacts (1)

Bifurcated Contacts

Cat. No.

Cat. No.

0

2

100-FA02

100-FAB02

1

1

100-FA11

100-FAB11

2

0

100-FA20

100-FAB20

1L

1L

100-FAL11, 0

4

100-FA04

100-FAB04

1

3

100-FA13

100-FAB13

100-FA22

100-FAB22

700-CF

2

2

3

1

100-FA31

100-FAB31

4

0

100-FA40

100-FAB40

1+1L

1+1L

100-FAL22, (1) For spring clamp terminals, insert CR after 100-. Example: Cat. No. 100-CRFA02.

Photo

Description

Auxiliary Contact Blocks for Side Mounting without Sequence Terminal Designations§ 1- and 2-pole Two-way numbering for right or left mounting on the contactor Quick and easy mounting without tools Electronic-compatible contacts down to 17V, 10 mA Mirror contact performance to the main relay poles 1L = Late break N.C./early make N.O.

N.O.

N.C.

0

1

100-SA01

1

0

100-SA10

0

2

100-SA02

1

1

100-SA11

2

0

100-SA20

For Use With

Cat. No.

700-CF

1L

IMPORTANT

Connection Diagrams

1L

100-SAL11

For maximum number of contacts, see the following tables.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

193

Page 195

IEC Industrial Relays

700-CF (AC electronic coils), vertical mounting, 60 °C(1) Cat. No. 700…

Max. N.O. Side Aux.

Max. N.C. Side Aux.

Max. N.O. Front Aux.

Max. N.C. Front Aux.

Max. N.O. Front + Side Aux.

Max. N.C. Front + Side Aux.

Max. N.O. + N.C. Front + Side Aux.

CF400 CF310 CF220 CF040

2 2 4 2

4 4 (2) 4 (2) 2

4 4 4 4

4 4(3) 2 0

6 6 8 6

7 5 5 2

8 8 8 6

(1) For other operating conditions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor. (2) With no front auxiliary contacts installed. Otherwise 3 N.C. Maximum (3) With no side auxiliary contacts installed. Otherwise 3 N.C. Maximum

700-CF (DC conventional coils), vertical mounting, 60 °C(1) Cat. No. 700…

Max. N.O. Side Aux.

Max. N.C. Side Aux.

Max. N.O. Front Aux.

Max. N.C. Front Aux.

Max. N.O. Front + Side Aux.

Max. N.C. Front + Side Aux.

Max. N.O. + N.C. Front + Side Aux.

CF400 CF310 CF220

2 2 2

2 2 2

4 4 4

4 (2) 4 (2) 2

6 6 6

5 5 4

8 8 8

(1) For other operating conditions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor. (2) With no side auxiliary contacts installed. Otherwise 3 N.C. Maximum

194

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 196

IEC Industrial Relays

Control Modules Photo

Description

Connection Diagrams

Pneumatic Timing Modules(1) ON-Delay Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay.

Reset Time

Repeat Accuracy

25…90 ms for AC Coils +/-10%

Pneumatic Timing Modules OFF-Delay Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay.

47…85 ms for DC coils

Delay

For Use With

0.3…30 s

100-FPTA30

1.8…180 s

100-FPTA180

0.3…30 s

700-CF all (1)

1.8…180 s

0.1…3 s 1…30 s

Electronic Timing Modules, On-Delay Delay of the control relay coil assembly. The control relay is energized at the end of the delay time.

10…180 s 100 ms

+/-1%

10…180 s 0.3…3 s 1…30 s 10…180 s 100 ms

+/-1%

700-CF 110…240V AC 110…250V DC conventional coils

10…180 s

100-ETA3 100-ETA30 100-ETA180 100-ETAZJ3

700-CF 24…48V DC coils

700-CF 110…240V AC coils

0.3…3 s 1…30 s

100-FPTB30

100-FPTB180

0.1…3 s 1…30 s

Electronic Timing Modules, Off-Delay Delay of the control relay coil assembly. After interruption of the control signal, the control relay is deenergized at the end of the delay time.

Cat. No.

100-ETAZJ30 100-ETAZJ180 100-ETB3 100-ETB30 100-ETB180 100-ETBKJ3

700-CF 24V AC coils

100-ETBKJ30 100-ETBKJ180

(1) On-Delay modules cannot be used with side-mounted auxiliary contacts on DC coil relays.

Photo

Connection Diagrams

Description

Mechanical Latch Following relay latching, the relay coil is immediately de-energized (off) by the N.C. auxiliary contact (65-66). Electrical or manual release 1 N.O. + 1 N.C. auxiliary contacts

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

For Use With

Cat. No.

700-CF with AC coils

100-FL11⊗

195

Page 197

IEC Industrial Relays

Photo

Connection Diagrams

Description

Cat. No. (1)

For Use With

24…48V 50/60 Hz RC Module AC Operating Mechanism

Surge Suppressors For limitation of coil switching transients. Plug-in, coil mounted

Varistor Module AC/DC Operating Mechanism

Diode Module DC Operating Mechanism Dropout Time 70…95 ms

100-FSC48

110…280V 50/60 Hz

700-CF with AC coils

100-FSC280

380…480V 50/60 Hz

100-FSC480

12…55V AC/ 12…77V DC

100-FSV55

56…136V AC/ 78…180V DC

100-FSV136

700-CF all

137…277V AC/ 181…350V DC

100-FSV277

278…575V AC

100-FSV575

12…250V DC

700-CF with Conventional DC 100-FSD250 coils

(1) For spring clamp terminals, insert CR after 100-. Example: Cat. No. 100-CRFSC48.

Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 100-FL11⊗ becomes Cat. No. 100-FL11J. [V] (1)

24

48

100

110

120

230...240

240

277

380...400

400...415

440

480

50 Hz

K

Y

KP

D, VA

T, N

G

B, 60 Hz

J, - - D, A

T, - N

B

(1) For special voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.

Photo

Connection Diagrams

Description (Relays)

DC Interface (electronic) Interface between the DC control signal (PLC) and the AC operating mechanism of the control relay. Control (input) voltage 12V DC 24V DC 48V DC Requires no additional surge suppression on the relay coils

196

For Use With (Relays)

Input: 24V DC Output: 110…240V AC Input: 12V DC Output: 110…240V AC Input: 48V DC Output: 110…240V AC

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Cat. No.

100-JE

700-CF with 110…240V AC coils

100-JE12

100-JE48

Page 198

IEC Industrial Relays

Specifications 100-J... DC Interfaces Cat. No. 100-JE

Cat. No. 100-JE12

Cat. No. 100-JE48

Electrical Input Voltage

24V DC

12V DC

48V DC

Input Voltage Range

18…30V DC

6…12V DC

35…48V DC

Output Voltage

110…240V AC

110…240V AC

110…240V AC

Power Consumption

0.1…0.4 W

0.02…0.12 W

0.2…0.5 W

Minimum Actuation

5V DC, 2 mA DC

5V DC, 2 mA DC

5V DC, 2 mA DC

IP20

IP20

IP20

Pickup Time

0…10 ms + pickup time of the contactor

0…10 ms + pickup time of the contactor

0…10 ms + pickup time of the contactor

Dropout Time

0…10 ms + dropout time of the contactor

0…10 ms + dropout time of the contactor

0…10 ms + dropout time of the contactor

2 (1)

2 (1)

2 (1)

In: 50V, Out: 250V

In: 50V, Out: 250V

In: 50V, Out: 250V

4 kV

4 kV

4 kV

Ambient Temperature Range

-25…+60 °C

-25…+60 °C

-25…+60 °C

Storage Temperature Range

-50…+80 °C

-50…+80 °C

-50…+80 °C

Operating Life

100 + million ops

100 + million ops

100 + million ops

1 Wire

0.5…2.5 mm2

0.5…2.5 mm2

0.5…2.5 mm2

2 Wire

0.75…2.5 mm2

0.75…2.5 mm2

0.75…2.5 mm2

1 Wire

1.0…2.5 mm2

1.0…2.5 mm2

1.0…2.5 mm2

2 Wire

1.0…2.5 mm2

1.0…2.5 mm2

1.0…2.5 mm2

18…14 AWG

18…14 AWG

18…14 AWG

1…1.5 N•m / 7…15 lb•in

1…1.5 N•m / 7…15 lb•in

1…1.5 N•m / 7…15 lb•in

LED

LED

LED

Mechanical Finger Protection

Max. Cycles Per Second Isolation/Breakdown Voltage Rated Impulse Withstand Voltage Environmental

Construction Flexible wire Wire Size Range

Solid wire Solid and Stranded

Tightening Torque Type of Light (1) To consider the maximum operations/hour of the relays.

Assembly Components Photo

Description

For Use With

Pkg Qty. (1)

Cat. No.

Protective Covers Provides protection against unintended manual operation

700-CF all

1

100-SCCA

Protective Covers • Provides protection against unintended manual operation • For contactors and front-mounted auxiliary contacts, pneumatic timers, and latches

100-FA, -FB, -FC, -FP, -FL; 10

100-SCFA

(1) All Cat. Nos. are factory stocked.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

197

Page 199

IEC Industrial Relays

Accessories Uniform labeling materials for contactors, motor startup equipment, relays, and circuit breakers. Photo

Pkg. Qty. (1)

Cat. No.

Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm

10

100-FMS

Marking Tag Sheet 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover

10

100-FMP

Transparent Cover To be used with marking tag sheets

100

100-FMC

Marking Tag Adapters To be used with marking tag: System V4/V5

100

100-FMA1

Description

100-FMA2

System 1492 W (1) Must be ordered in multiples of package quantities.

198

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 200

IEC Industrial Relays

Coils Photo

AC Coil Code Q R J K KJ V W X Y KY KP D KD P S KG H L KL A F KF VA T KA I E N KN G B KB M C

50Hz, 12V, 24V, 32V 36V 42V 48V, 100V 110V, 120V 127V 200V, 200 - 220V, 220V 220 - 230V, 230 - 240V 240V, - - 380 - 400V, 400-415V 440V, 500V 550V

AC Voltages 60Hz 12V, 24V, - 36V, 48V, - 100 - 110V 120V, - - 200 - 220V 208V 208 - 240V, 240V 260V, - 277V, 347V 380V 440V, - 480V, - 600V

50/60Hz, - - - 24V, - - - 48V 100V, 110V, - 200V, - 200 - 230V, - 230V, - 240V, - - 400V, - 440V, - Cat. No. 700-CF TA006 TA404 TA013 TA407 TA855 TA481 TA410 TA482 TA414 TA860 TA861 TA473 TA856 TA425 TA428 TA862 TA049 TA296 TA864 TA474 TA441 TA851 TA440 TA480 TA858 TA065 TA067 TA071 TA863 TA457 TA475 TA859 TA479 TA476

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

199