General Purpose Electronic Timers and Counters
General Timer Functions- 700-HX Relays Display Section
Operation Key
1. Key Protect Indicator (orange)
4
2. Control Output Indicator (orange)
5 1 2 3 8
3. Reset Indicator (orange) 4. Present Value Display (Main display) (Character height: 12 mm, red *) * Characters on models with screw terminals can be switched between red, green, and orange.
8. Mode Key (Changes modes and setting items)
6 7
10 11
9
Front View
9. Reset Key (Resets present value and output) 10. Up Keys 1 to 4 11. Down Keys 1 to 4
12
5. Time Unit Indicators (Color is same as present value display.) (If the time range is 0 min, 0 h, 0.0 h, or 0 h 0 min, these indicators flash to indicate timing operation.)
Switches 12. Key-protect Switch (Default setting)
6. Set Value Display (Sub-display) (Character height: 6 mm, green) 7. Set Value 1, 2 Indicator (green) Character Size for Present Value Display
12 mm
140
Character Size for Set Value Display
6 mm
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
OFF (Disabled)
ON (Enabled)
Page 142
General Purpose Electronic Timers and Counters
Specifications - 700-HX Relays Attribute
700-HX
Electrical Ratings Pilot Duty Rating
NEMA B300
Rated supply voltage
100 to 240V AC, 24V AC/12 to 24V DC (50/60Hz) (permissible ripple: 20%(p-p) max.)
Operating voltage range
85…110% of rated supply voltage
Power consumption
Inrush Current
Make
Break
100…240V AC
4.3VA
24V AC/12…24V DC
3.4VA/1.7 W
100…240V AC
3A
24V AC/12…24V DC
5A
120V AC
30 A
240V AC
15 A
120V AC
3A
240V AC
1.5 A
Hp at 120V AC
1/4 Hp
Hp at 240V AC
1/3 Hp Mechanical
Mounting Method
Flush mounting, surface mounting, DIN mounting
Display
Seven-segment, negative transmissive LCD; Present value (red, 12 mm high characters); Set value (green, 6 mm high characters)
Digits
Four digits
Timer
Inputs
Time ranges
0.000…9.999 s, 0.00…99.99 s, 0.0…999.9 s, 0…9999 s, 0 min 00 s…99 min 59 s, 0.0…999.9 min, 0 hr 00 min…99 hr 59 min, 0.0 hr…999.9 hr, 0 hr…9999 hr
Timer modes
Elapsed time (Up), remaining time (Down), selectable
Output modes
A, A-1, A-2, A-3, B, B-1, D, E, F, Z, S, tOFF, tON, tOFF-1, or tON-1
Input signals
Start, reset
Input method
No-voltage input via:NPN transistor or switching of contact
Start, reset, gate
Minimum input signal width: 1 or 20 ms (selectable)
Power reset Control output
Minimum power-opening time: 0.5 s (Except for A-3, B-1, and F mode) SPDT contact output: 5 A at 250V AC, resistive load (cosine=1) Minimum applied load: 10 mA at 5 V DC (failure level: P, reference value)
External Power Supply
No
Key Protect
Yes
Memory Backup Accuracy of Operating Time and Setting Error (1)
EEP-ROM (overwritten 100 000 times min), which can store data for 10 years min. Power-ON start: +-0.01% +-50 ms max. (1)to be rated against set value Signal start: +- 0.005% +-30 ms max. (1)to be rated against set value Signal start at transistor output model: +- 0.005% +-3 ms max. (2) If the set value is within the sensor waiting time (250 ms max.)
(1) The values are based on the set value. (2) The value is applied for a minimum pulse width of 1 ms.
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
141
Page 143
General Purpose Electronic Timers and Counters
Attribute
700-HX Environmental
Installation environment
Setup category II, pollution degree 2 (as per IEC61010-1)
Ambient temperature
-10 to +55 °C (Avoid freezing or condensation)
Ambient humidity
25 % to 85 %
Storage temperature
-25 to +65 °C (Avoid freezing or condensation)
Altitude
MAX. 2,000 m
Characteristics
(1)
Insulation Resistance
100 mΩ min. (at 500V DC)
Dielectric Strength
2000V AC, 50/60Hz for 1 min between current-carrying terminals and non-current- carrying metal parts (1000V AC for 24V AC/12 to 24V DC type), 1000 VAC, 50/60 Hz for 1 min between noncontinuous contacts
Noise Immunity
±1.5 kV (between power terminals) for 100 to 240 VAC, ±480V for 24VAC/12 to 24VDC, and ±600V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static Immunity
±8 kV (malfunction), ±15 kV (destruction)
Vibration Resistance
Malfunction
10…55 Hz with 0.35 mm single amplitude each in three directions for 10 min
Shock Resistance
Malfunction
98 m/s2 (approx. 10 G) each in three directions
Mechanical
10 million operations min. (under no load at 18 000 operation/hr)
Electrical
100 000 operations min. (5 A at 250V AC, resistive load at 1800 operation/hr)
(EMI)
EN61812-1
Life Expectancy
EMC
Emission Enclosure:
EN55011 Group1 class A
Emission AC mains:
EN55011 Group1 class A
(EMS)
EN61812-1
Immunity ESD:
EN61000-4-2: 4 kV contact discharge (level2) 8 kV air discharge (level3)
Immunity RF-interference:
EN61000-4-3: 10 V/m Panel surface:IP66 and NEMA Type 4 (indoors) (2)
Enclosure Ratings Weight
Approx. 100 g
Certifications
CE Certified; cURus (File No. E14843, Guide NRNTZ/NRNT8), C-Tick Marked
Standards
EN61010-1, EN 61326, VDE0106/P 100, CSA C22.2 No. 14, UL 508
(1) More information in the 700-HX User Manual, publication 700-UM002. (2) An attached waterproof packing is necessary to ensure IP66 waterproofing between the 700-HX and installation pan.
142
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
Page 144
General Purpose Electronic Timers and Counters
Timing Charts- 700-HX Relays One-Shot Sustained Output
One-shot outputs can be set to 0.1s, 0.5 s, 1 s, 5 s, 10 s, or 20 s.
Output Mode A Mode: Signal ON-Delay (Timer resets when power comes ON.)
Timing starts when the start signal goes ON. While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF. The control output is controlled using a sustained or one-shot time period.
Power
Start signal
Basic Operation
Gate* Reset t t
Control output t
Power ** Start Signal Input Timing
Set value Timing diagram
UP
Output
0
Set value DOWN 0
*Output is instantaneous when setting is 0. ** Start signal input is enabled during timing. Output Mode A-1: Signal ON-Delay 2 (Timer resets when power comes ON.)
Timing starts when the reset input goes ON and is reset when the start signal goes OFF. While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. The control output is controlled using a sustained or one-shot time period.
Power
Start signal Gate*
Basic Operation
Reset
Power Control output
Start Signal Input
Set value UP Timing diagram
0
Timing
Output
Set value DOWN 0
*Output is instantaneous when setting is 0. Output Mode A-2: Power ON Delay 1 (Timer resets when power comes ON)
Power
Timing starts when the reset input goes OFF. The start signal disables the timing function (i.e., same function as the gate input). The control output is controlled using a sustained or one-shot time period.
Start signal Gate *
Basic Operation
Reset
Power
Control output
Timing Set value Timing diagram
UP
Output
0
*Output is instantaneous when setting is 0.
Set value DOWN 0
Output Mode A-3 Power ON Delay 2 (Timer does not reset when power comes ON) Power
Start signal Gate * Reset Control output Set value Timing diagram
UP
0
Set value DOWN 0
Timing starts when the reset input goes OFF. The start signal disables the timing function (i.e., same function as the gate input). The control output is controlled using a sustained or one-shot time period.
Basic Operation Power Timing Sustained Output *Output is instantaneous when setting is 0.
Gate not included on any mode of this relay.
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
143
Page 145
General Purpose Electronic Timers and Counters
Output Mode B: Repeat Cycle (Timer resets when power comes ON.)
Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF.
Sustained Output
Basic Operation
Power
Start signal
Power Gate*
** Start Signal Input
Reset
Timing
Control output
Timing diagram
UP
Timing
Timing
Timing
Output
Set value 0
* Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled diring timing.
Set value DOWN 0
Timing starts when the start signal goes ON. The control output is turned ON when time is up. While the start signal is ON, the timer starts when the power cones ON or when the reset input goes OFF.
One-Shot Output Power
Basic Operation
Start Signal
Power
Gate*
** Start Signal Input
Reset
Timing
Control Output
Timing
Timing
Timing
Output
* Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing.
Set Value 0 Timing UP Set Value Diagram 0 DOWN
Output Mode B-1: Repeat Cycle 2 (Timer does not reset when power comes ON) Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at the start). While the start signal is ON, the timer starts when the power comes ON or when the rest input goes OFF.
Sustained Output
Basic Operation
Power
Power ** Start Signal Input
Start signal Gate*
Timing
Reset
Set value Timing diagram
Timing
Output
Control output
UP
Sustained
* Normal output operation will not be possible if the set time is too short Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during.
0
Set value DOWN 0
One-Shot Output
Timing starts when the start signal goes ON. The control output comes ON when time is up. While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF.
Basic Operation Power
Power Start signal Gate*
** Start Signal Input
Timing
Timing
Reset
Output Control output Set value Timing diagram
UP
0
Set value DOWN 0
Gate not included on any mode of this relay.
144
Sustaining
* Normal outout operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing.
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
Page 146
General Purpose Electronic Timers and Counters
Output Mode D: Signal OFF-Delay (Timer resets when power comes ON.)
The control output is ON when the start signal is ON (except when the power is OFF or the reset is ON). The timer is reset when the time is up.
Power
Start signal
Basic Operation Gate*
Power ** Start Signal Input
Reset Control output
Timing
Set value Timing diagram
UP
Output
0
* Output functions only during start signal input when setting is 0. ** Start signal input is enabled during timing.
Set value DOWN 0
Output Mode E: Interval (Timer resets when power comes ON.)
Timing starts when the start signal comes ON. The control output is reset when time is up. While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF.
Power
Basic Operation
Start signal Gate*
Power
Reset
** Start Signal Input
Control output
Timing
Set value Timing diagram
UP
0
Output
Set value DOWN 0
* Output is disabled when the setting is 0. ** Start signal input is enabled during timing. Output Mode F: Cumulative (Timer does not reset when power comes ON) Start signal enables timing (timing is stopped when the start signal is OFF or when the power is OFF). A sustained control output is used.
Basic Operation Power Start Signal Input Timing
Output
Timing Sustained
*Output is instantaneous when setting is 0.
Gate not included on any mode of this relay.
Z Mode Output quantity can be adjusted by changing the cycle time set in the adjustment level to 1 and by changing the ON duty (%) set value. The set value shows the ON duty (%) and can be set to a value between 0 and 100 (%). When the cycle time is 0, the output will always be OFF. When the cycle time is not 0 and when ON duty has been set to 0 (%), the output will always be OFF. When ON duty has been set to 100 (%), the output will always be ON.
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
145
Page 147
General Purpose Electronic Timers and Counters
Z mode: ON/OFF-duty Adjustable Repeat Cycle Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF.
Power
Basic Operation
Start signal * Gate
Power
Reset
** Start signal input
Timing ON duty (%)
ON duty setting (%) ON time 0
UP
Timing (cycle time)
Timing (cycle time)
Control Output Cycle time
Timing ON duty (%)
Output
Cycle time Timing diagram
* Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is enabled during timing.
ON duty setting (%) ON time 0
DOWN
Output Mode S: Stop Watch (Timer resets when power comes ON) Power
Start signal
Gate/Reset
The signal starts and stops timing. The display is held and timing is continued if the reset or gate input is received during timing operation. The timer resets if the reset or gate input is received when the timing operation is stopped.
Basic Operation
9999
Power
Timing diagram
Set time Start signal input
UP
Timing
Gate/Reset
0 Set time DOWN 0
Output
*
Display (for elapsed time)
* RST flashes
Note: Output is instantaneous when setting is 0.
Output Mode T OFF: Twin Timer OFF start
Sustained Output Power
Start signal
Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF.
Basic Operation
* Gate
Reset Control Output
Power ** Start Signal Input Timing OFF
OFF Time UP Timing diagram
ON Time
ON Time 0
Timing ON
Output * Normal output operation will not be possible if the ON/OFF set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing.
Gate not included on any mode of this Relay.
146
Timing OFF
0 OFF Time
DOWN
Timing ON
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
Page 148
General Purpose Electronic Timers and Counters
Output Mode T ON: Twin Timer ON start
Sustained Output
Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF.
Power
Start signal
Basic Operation * Gate
Power ** Start Signal Input
Reset Control Output
Timing ON
OFF Time UP
ON Time
Timing diagram
Timing OFF
Timing ON
Timing OFF
Output
0 OFF Time
DOWN
* Normal output operation will not be possible if the ON/OFF set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing.
ON Time 0
Output Mode TOFF-1: Flicker OFF start 2 (Timer does not reset when power comes ON) Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF.
Power
Start signal
Basic Operation Gate
Power Reset
* Start signal input
Timing diagram
Control output
Timing OFF
Timing ON
Timing OFF a b
Output
OFF time UP ON time
(a + b = ON time)
* Start signal input is disabled during timing. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type).
0 OFF time DOWN ON time 0
Output Mode TON-1: Flicker ON start 2 (Timer does not reset when power comes ON) Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF.
Basic Operation Power
* Start signal input
Timing ON
Timing OFF
Timing ON a b
Output (a + b = OFF time)
* Start signal input is disabled during timing. Note: Normal output operation will not be possible if the set time is too short.
Gate not included on any mode of this Relay.
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
147
Page 149
General Purpose Electronic Timers and Counters
Dimensions- 700-HX Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 48×48
7.5
14.3
63.7
44.8×44.8
60 min. 45 +0.6 −0 45 +0.6 −0 60 min. 15 min.
Cat. No. 700-HX… Panel Cutout
5.2 (13/64)
6.2 (15/64)
50 (1-63/64)
12.5 (1/2)
1.0 (0.04)
35.0 (1.38)
7.5 (0.3)
1000 (39-3/8) Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
Terminal Arrangement
Internal circuit Signal Reset
4
5
3
6 7
2 1
8
0V
(–) (+) Cat. No. 700-HX…
148
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
27.0 (1.06)
Page 150
NEMA Heavy-Duty Industrial Relays
NEMA Industrial Relays Product Overview
Bulletin No.
700-P
700S-P
700-N
Type
Heavy-duty control relay
Heavy-duty control relay
Industrial Relay
Features
• Convertible contacts • Up to 600V AC & DC • Very long life • Timer & latch options • Mechanically linked
• Convertible contacts • Up to 600V AC & DC • Very long life • Timer & latch options • Mechanically linked
• Contact cartridges convertible from N.O. to N.C. and vice versa • NEMA A300 AC • 24…250V AC coils • Pneumatic timing unit • Solid-state timing unit • Overlap contacts • Logic reed contacts
Contact Form
2…12 poles, double break
2…12 poles, double break
2- or 4-poles
Contact Type
Bifurcated double break
Bifurcated double break, Contact Material
Bifurcated silver nickel
Bifurcated silver nickel
Silver
Max. Current AC Resistive
10 A
10 A
10 A
Min. load
10V, 50 mA 1 mA, 5V with 700-CPR
10V, 50 mA 1 mA, 5V with 700-CPR, Coil Voltage
24…600V AC 6…600V DC
24…600V AC 6…600V DC, Coil Voltage Pickup
85…110% AC coils, 80…110% DC coils
85…110% AC coils, 80…110% DC coils, Dielectric Withstand
2640V
2640V, Electric Service Life (cycles)
10 million at 10 A 120V AC
10 million at 10 A 120V AC, Certifications cULus, CE cULus, CE
UL, CSA, CE
Sockets
DIN Rail, relay rail, or panel mount
DIN Rail, relay rail, or panel mount, Product Selection
151
151
172
Electrical
Reference