Page 211
IEC Industrial Relays
Dimensions - 700S-CF Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. c2 c1 c
AC and DC Safety Control Relays with 12V or 24V DC Electronic Coil Cat. No.
a b c c1
Ød c2 d1 d2
45
81
119.5
114.5
6
2 - 4.5
60
35
(1-25/32)
(3-3/16)
(4-3/4)
(4-43/64)
(1/4)
(2 - 3/16)
(2-23/64)
(1-25/64)
700S-CF
DC Safety Control Relays with 48...72V, 110...125V or 220...250V DC Electronic Coil Cat. No.
a b c c1
Ød c2 d1 d2
45
105
119.5
114.5
6
2 - 4.5
60
35
(1-25/32)
(4-1/8)
(4-3/4)
(4-43/64)
(1/4)
(2 - 3/16)
(2-23/64)
(1-25/64)
700S-CF
DC Safety Control Relays with Conventional Coil Cat. No.
a b c c1
Ød c2 d1 d2
45
81
145.5
140.5
6
2 - 4.5
60
35
(1-25/32)
(3-3/16)
(5-49/64)
(5-37/64)
(1/4)
(2 - 3/16)
(2-23/64)
(1-25/64)
700S-CF
Accessories - 700S-CF Relays Safety Control Relays with Auxiliary contact block for side mounting 1- or 2-pole Electronic Timing Module on coil terminal side Interface Module on coil terminal side Surge Suppressor on coil terminal side Labeling with label sheet Marking tag sheet with clear cover Marking tag adapter for System Bul. 1492W
Mounting Position AC and DC E Safety Control Relays
Front View
210
Side View
DC Safety Control Relays
Front View
Side View
Rockwell Automation Publication 700-TD552B-EN-P - August 2018 mm
[in.] a+9 b + 24 b+9 b+3 +0 +0 + 5.5
(a + 23/64) (b + 15/16) (b + 23/64) (b + 1/8) (+ 0) (+ 0) (+ 7/32)
Page 212
IEC Industrial Relays
Safety Relay Circuit With 5 Safety Outputs • Use for E-stop control. E-stop will work properly if any one fault occurs (a fault could be one welded contact or one undesired open connection such as a loose wire). • High output switching capability and long contact life. • Circuit complies with EN 954 categories 1, 2, 3, 4. • Helps prevent restart of the 5 safety outputs if there is a single fault anywhere in the system. • Use (3) 700S-CF relays and this diagram to construct the circuit Basic Circuit (1) Output Circuit (3 Relays, 9 Terminal Blocks)
Start
Push To Stop Pull To Reset
Included in factory wired units
LOAD 1 (5) Output Circuit (3 Relays, 17 Terminal Blocks) LOAD 2 LOAD 3 LOAD 4 LOAD 5
* Numbers shown are the line numbers where the contacts for this relay appear. Contact your local Rockwell Automation sales office or Allen-Bradley distributor for availability.
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
211
Page 213
IEC Industrial Relays
700-K Miniature Control Relays • IEC compact industrial relay • IP2X Finger Protection • Bifurcated contacts for low-level signals • Optional integrated coil protection diode
4-Pole AC or DC Coil Voltage AC-12
AC-15 (B600)
Ith [A]
Ie [A]
40 °C
10
60 °C
6
Contacts Pkg. Qty.(2)
Connection Diagrams
24/48V
3
120V
3
240V
400V
2
500V
1
1
600V
0.6
690V
Cat. No.
N.O.
N.C.
4
0
1
700-K40E-⊗
3
1
1
700-K31Z-⊗
2
2
1
700-K22Z-⊗
1
700-KL22Z-⊗
0.6
1+1L (1) 1+1L (1) 1L = Late Break N.C. / Early Make N.O. (2) May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-K40E-ZJM.
⊗ Coil Voltage Codes The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 230V, 50/60 Hz: Cat. No. 700K40E-⊗ becomes Cat. No. 700-K40E-KF. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. For Screw Type Terminal Versions [V]
12
24
110
120
125
220
230
240
250
400
440
480
525
600
AC, 50 Hz, - D, - - - - - - B, VC, AC, 60 Hz, - - D, - - - - - - B, VC
AC, 50/60 Hz, KJ, - - - KF
KA, KN, - - - ZQ
ZJ
ZD, ZS
ZA, - ZT, - - - - - DJ, - - - - - - - - - - - Standard Standard diode
DC
For Spring Clamp Type Terminal Versions AC, 50 Hz, - D, - - - - - - - - - - AC, 60 Hz, - - D, - - - - - - - - - AC, 50/60 Hz, KJ, - - - KF, - - - - - - - ZJ
ZD, - - - - - - - - - - - DJ, - - - - - - - - - - - Standard Standard diode
212
DC
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
Page 214
IEC Industrial Relays
Assignment of Contacts Device Combinations in Accordance with IEC 60947-1 / -4-1 Table valid for: AC / DC = 0.85…1.1 x Us, Tamb. = -25 °C…+60 °C, normal position (horizontal rail mounting). Also valid for 700-KR relays and 100-KR auxiliary contacts. (3) Auxiliary Contact Blocks Cat. No.
Circuit Diagram
Control Relays 700-K (AC and DC Control) Control
700-K22Z-
700-K31Z-
700-K40E-
700-KL22Z-
A1 13 43 21 31
A1 13 33 43 21
A1 13 23 33 43
A1 13 47 21 35
A2 14 44 22 32
A2 14 34 44 22
A2 14 24 34 44
A2 14 48 22 36
AC/DC, 31Z + 02E = 33Y (1)
40E + 02E = 42Y, AC/DC
22Z + 11E = 33Y
31Z + 11E = 42Y
40E + 11E = 51Y
L22Z + 11E = L33Y
AC/DC
22Z + 20E = 42Y
31Z + 20E = 51Y
40E + 20E = 60Y
L22Z + 20E = L42Y
AC/DC, - 40E + 04E = 44Y (1), AC/DC, 31Z + 13E = 44Y (1)
40E + 13E = 53Y, AC/DC, 31Z + 22Z = 53Y (1)
40E + 22Z = 62Y, AC/DC, - 40E + 31Z = 71Y (2), AC/DC
22Z + 40E = 62Y
31Z + 40E = 71Y
40E + 40E = 80Y
L22Z + 40E = L62Y
Front Mounting 51 61
100-KFA02E 52 62 53 61
100-KFA11E 54 62 53 63
100-KFA20E 54 64 51 61 71 81
100-KFA04E 52 62 72 82 53 61 71 81
100-KFA13E 54 62 72 82 53 83 61 71
100-KFA22Z 54 84 62 72 53 73 83 61
100-KFA31Z 54 74 84 62 53 63 73 83
100-KFA40E 54 64 74 84
(1) Tamb. max. +40 °C (2) Tamb. max. +40 °C and only allowed for coil voltage 24V DC or 230V AC (3) For other operating limits, please contact our technical consultant.
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
213
Page 215
IEC Industrial Relays
Auxiliary Contact Blocks Photo
Description
Connection Diagrams
For Use With
Pkg. Qty.
Screw Type Terminals
Spring Clamp Terminals
Cat. No.
Cat. No.
(1)
N.O.
N.C.
0
2
100/104-K, 700-K
1
100-KFA02E
100-KRFA02E
1
1
100/104-K, 700-K
1
100-KFA11E
100-KRFA11E
2
0
100/104-K, 700-K
1
100-KFA20E
100-KRFA20E
0
4
100/104-K, 700-K
1
100-KFA04E
100-KRFA04E
1
3
100/104-K, 700-K
1
100-KFA13E
100-KRFA13E
2
2
100/104-K, 700-K
1
100-KFA22Z
100-KRFA22Z
3
1
100/104-K, 700-K
1
100-KFA31Z
100-KRFA31Z
4
0
100/104-K, 700-K
1
100-KFA40E
100-KRFA40E
51 61 52 62 53 61 54 62 53 63 54 64
Front-mounted auxiliary contacts
• Auxiliary Contact Blocks • 2- and 4-pole versions • Choice of contact configurations • Snap on, no tools required • Electronic-compatible bifurcated contacts for signals down to 15V / 2 mA
51 61 71 81 52 62 72 82 53 61 71 81 54 62 72 82 53 83 61 71 54 84 62 72 53 73 83 61 54 74 84 62 53 63 73 83 54 64 74 84
(1) May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFA02EM.
Control Modules Description
Photo
Connection Diagrams
For Use With
Pkg. Qty.
Cat. No.
1
100-KMCH
1 (1)
100-KFSC50
(1)
100-KFSC280
1 (1)
100-KFSC480
1 (1)
100-KFSV55
1 (1)
100-KFSV136
1 (1)
100-KFSV277
1 (1)
100-KFSD250
Mechanical Interlock
• For interlocking of two adjacent contactors • No added width to contactor assembly • Front mount plug-in type • Optional auxiliary contact blocks and suppressor modules mount onto the interlock 24…48V AC RC Suppressor
110…280V AC 380…480V AC
100/104-K/KR, 700-K/- KR
12…55V AC, 12…77V DC
Surge Suppressor
• Plug-in type • Limits surge voltage on coil drop-off
100/104-K/KR, 700-K/- KR
MOV Suppressor
56…136V AC, 78…180V DC
100/104-K/KR, 700-K/- KR
137…277V AC, 181…250V DC Diode Suppressor
12…250V DC
(1) May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFSC50M.
214
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
100/104-K/KR, 700-K/- KR
1
Page 216
IEC Industrial Relays
Accessories Photo
Description
Pkg. Qty.
Cat. No.
Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm
10
100-FMS
Snap-In Marker Card
5
1492-M6X12
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
215
Page 217
IEC Industrial Relays
IEC Specifications - 700-K... Relays 700-K
700-KR
AC-12 Rated Thermal Current Ambient temperature 40°C
Ith
24…240V
[A]
10
230…500V
[A]
10
230…690V
[A]
10
24…240V
[A]
6
230…500V
[A]
6
230…690V
[A]
6
24V
[A]
3
48V
[A]
3
120V
[A]
3
230V
[A]
2
240V
[A]
2
400V
[A]
1.2
480V
[A]
1
Ambient temperature 60°C
Ith
AC-15/B600 Switching of Solenoids and contactors
Ie
500V
[A]
1
600V
[A]
0.6
690V
[A]
0.6
Fuse gG
[A]
10
[mA]
2
Main current circuit resistance, 1 pole
[mΩ]
6.5
Power dissipation, 4 poles
[W]
2.6
AC control, warm
[W]
4.4
DC control, warm
[W]
5.2
Mechanical
[Mio. op.]
15
Electrical AC-15 (240V / 2 A)
[Mio. op.]
0.7
AC control kg (lbs.)
0.16 (0.35)
DC control kg (lbs.)
0.2 (0.44)
Rated voltage
AC
[V]
Continuous rating
40 °C
[A]
Switching capacity
AC
[A]
B 600
Rated voltage
DC
[V] max. 600
Switching capacity
DC
[A]
Q 600
Short-circuit Protection
Min. Switching Capacity 15V
Resistance and Power Dissipation
Total power dissipation
Lifespan
Weight
Load Carrying Capacity per UL/CSA
216 max. 600 10
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
6
Page 218
IEC Industrial Relays
700-K DC-13/Q600
1 pole
24V
[A]
2.3
48V
[A]
1
110V
[A]
0.55
125V
[A]
0.55
220V
[A]
0.27
250V
[A]
0.27
400V
[A]
0.15
440V
[A]
0.15
600V
[A]
0.1
Cross Sections Conductor Cross Sections - Main Contacts, Auxiliary Contacts, and Coil Terminals
700-K
700-KR (1)
Terminal type
Fine stranded with ferrule
(1) Conductor (2) Conductors
[mm2]
Solid or coarse stranded
(1) Conductor (2) Conductors
[mm2]
0.75…2.5 0.75…2.5
0.50…2.5 0.50…2.5
[mm2]
1…4 1…2.5 + 1…4
0.75…2.5 (3) 0.75…2.5 (3)
[Nm]
1.2, Cross section per UL/CSA
[AWG]
18…12 (2)
18…14 (3)
Recommended torque
[lb-in]
10.6, Recommended torque
[mm2]
(1) Pozidriv No. 2 / Blade No. 3 screw (2) Use same cross sections (3) Stranded wire only
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
217
Page 219
IEC Industrial Relays
Coil Data 700-K Operating Limits pick-up
[x Us]
0.85…1.1 dropout
[x Us]
0.2…0.75 pick-up
[x Us]
0.8…1.1 9, 12, 24, 110V DC: 0.7…1.25 dropout
[x Us]
0.1…0.75 pick-up
[VA/W]
35/32 hold-in
[VA/W]
5/1.8 pick-up
[W] cold 3.0, warm 2.6 hold-in
[W] cold 3.0, warm 2.6 closing delay
[ms]
15…40 opening delay
[ms]
15…33 opening delay
[ms]
15…28 closing delay
[ms]
18…40 opening delay
[ms]
6…12
With integrated diode closing delay
[ms]
8…12
With external diode opening delay
[ms]
35…50
AC control 50 Hz, 60 Hz, 50/60 Hz
DC control Coil Consumption
AC control 50 Hz, 60 Hz, 50/60 Hz DC control Operating Times
AC With RC module DC
Dimensions - 700-K... Relays Approximate dimensions are shown in millimeters. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for manufacturing purposes.
(mm)
12 35 45
4
35.2
*)
*) -Minimum distance to grounded parts or walls
49 79
218
180°
54
56
50
25° 25°
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
Page 220
Solid-State Relays
Solid-state Relays Product Overview
Bulletin No.
700-SA
700-SC
Type
Tube Base, Socketed
Miniature, Ice Cube Socketed
Features
Compatible with 700-HN100, 125,108, and 204 socket, LED status, zero-cross switching
Compatible with 700-HN103 or 128 socket, LED Status, and Zerocross AC Switching Options
Load Type
AC (47…63 Hz)
DC
AC (47…63 Hz)
DC
Load Voltage Range
75…264V AC
3…125V DC
75…264V AC
3…52.8V DC or 3…125V DC
Load Current Max. (Continuous)
5A
3A
3A
3 A @ 48V DC or 2 A @ 110V DC
Max. Leakage Current to Load
5 mA @ 100V, 10 mA @ 200V
5 mA @ 125V
5 mA @ 100V AC
10 mA @ 200V AC, 5 mA @ 50V DC or 0.1 mA @ 100V DC
Zero Cross Load Switching
Yes
Not Applicable
Yes (optional)
Not Applicable
Equivalent Electromechanical Relay Contact Arrangement
Form A
Form A
Rated Control (Input) Voltage
5…24V DC
5…24V DC, 100…110V AC, 200/220V AC
5...24V DC
LED Indicator
Yes
Yes (optional)
Yes (optional for 48V DC)
Mounting Method
Panel or DIN with socket
Panel or DIN with socket
Dielectric Strength
1500V AC, 50/60 Hz, 1 min.
1500V AC, 50/60 Hz, 1 min.
Certification cURus, CE, VDE cURus, CE, VDE
Max. Ambient Operating Temperature
-30…80 °C (no condensation)
-30…80 °C (no condensation)
Page
221
226
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
219