Page 221

Solid-State Relays

Product Overview

Bulletin No.

700-SF

700-SH

700-SK

Type

Square Base, Socketed

Hockey Puck

Slim Line, Socketed

Features (1)

Compatible with 700-HN116 socket, LED status, zero-cross AC switching

Panel/DIN Mount, High Current, Protective Cover, LED Status

Compatible with 700-HN121 socket. Supports Input (sensor) module or Output (SSR) module

Load Type

AC (47…63 Hz)

DC

AC (47…63 Hz) 3…60V DC

Load Voltage Range

75…264V AC

3 … 52.8V DC

Load Current Max. (Continuous)

3A

Max. Leakage Current to Load

5 mA @ 100V AC, 10 mA @ 200V AC

Zero Cross Load Switching

Yes

Equivalent Electromecha nical Relay Contact Arrangement

Output Module

Input Module

AC (47…63 Hz)

DC

AC (47…63 Hz)

DC

3…50V DC, 24…265V AC 42…530V AC, 42…265V AC, 42…660V AC

75 … 264V AC

4 … 60V DC, 40 … 200V DC

Field Input: 60… 264V AC

Field Input: 6.6… 32V DC

10 A/100 A‡

2A

2 A @ 60V, 1.5 A @ 200V

Supply Current: 0.1…100 mA

Supply Current: 0.1…100 mA

5 mA @ 50V DC

<3 mA

1.5 mA

1 mA

5 μA

5 μA

Not Applicable

Yes

Yes (optional)

N/A

No

N/A

Form A

Form A

Form A

Rated Control (Input) Voltage

4V DC or 24V DC

3…32V DC, 4…32V DC, 80…130V AC, 20…260V AC 20…280V AC/22…48V DC

5… 24 V DC

LED Indicator

Yes

Yes

Yes

Mounting Method

Panel or DIN with socket

Panel without heat sink, Panel, or DIN with heat sink

Panel or DIN with socket

Dielectric Strength

1500V AC, 50/60 Hz, 1 min.

>4000V AC RMS

4000V AC, 50/60 Hz, 1 min.

Certification cURus, CE, VDE cURus, CE, CSA cURus, CE, TÜV

Max. Ambient Operating Temperature

-30…80 °C (no condensation)

-20…70 °C (no condensation)

-30…80 °C (no condensation)

Page

231

235

244

(1) See Solid-state Relay Glossary on page 221 for term definitions.

220

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 222

Solid-State Relays

Solid-state Relay Glossary Terms

Insulation

Circuit functions

Input

Meaning Basic insulation

Insulation for basic protection from electric shock (IEC950 1.2.9.2)

Supplemental insulation

Independent insulation that is provided outside of basic insulation to protect from electric shock when the basic insulation breaks down (IEC950 1.2.9.3)

Reinforced insulation

A single-layer of insulation (IEC950 1.2.9.5) that provides the same protection from electric shock as double insulation (insulation including both basic and supplemental insulation) according to conditions stipulated in IEC950 standards

Zero cross circuit

A circuit that starts operation with the AC load voltage at close to zero-phase.

Trigger circuit

A circuit for controlling the triac or thyristor trigger signal, which turns the load current ON and OFF.

Isolated input circuit

If the external circuit is prone to generating noise, or if wires from external sources are prone to the influence of inductive noise, in order to prevent malfunctions due to noise, it is necessary to electrically isolate internal circuits and external circuits (output circuits). An isolated input circuit is a circuit that isolates inputs and outputs by using components that are not connected electrically but that can transmit signals, such as contact relays or photocouplers.

Photocoupler

A component that runs the electric signal into a light emitter (for example, LED), changes it to a light signal, and then returns it to an electric signal using a photoelectric conversion element, such as a photo transistor. The space that is used for transferring the light signal is isolated thus providing good insulation and a high propagation speed.

Rated voltage

The voltage that serves as the standard value of an input signal voltage

Pickup (must-operate) voltage Minimum input voltage when the output status changes from OFF to ON.

Output

Input impedance

The impedance of the input circuit and the resistance of current-limiting resistors used. Impedance varies with the input signal voltage in case of the constant current input method.

Operating voltage

The permissible voltage range within which the voltage of an input signal voltage may fluctuate.

Dropout (Reset) voltage

Maximum input voltage when the output status changes from ON to OFF.

Input current

The current value when the rated voltage is applied.

Load voltage

This is the effective value for the power supply voltage that can be used for load switching or in the continuous-OFF state.

Maximum load current (continuous)

The effective value of the maximum current that can continuously flow into the output terminals under specified cooling conditions (i.e., the size, materials, thickness of the heat sink, and an ambient temperature radiating condition).

Leakage current

The effective value of the current that can flow into the output terminals when a specified load voltage is applied to the SSR with the output turned OFF.

Output ON voltage drop

The effective value of the AC voltage that appears across the output terminals when the maximum load current flows through the SSR under specified cooling conditions (such as the size, material, and thickness of heat sink, ambient temperature radiation conditions, etc.).

Minimum load current (continuous)

The minimum load current at which the SSR can operate normally.

Snubber circuit

A circuit consisting of a resistor R and capacitor C, which prevents faulty ignition from occurring in the SSR triac by suppressing a sudden rise in the voltage that is applied to the triac.

Semiconductor output element (switching element)

This is a generic name for semiconductors such as the thyristor, triac, power transistor, and power MOS FET. In particular, triacs are often used in SSRs because they allow switching to be performed with one element.

Repetitive peak OFF-state voltage (VDRM)

This is a rating for an output semiconductor that used in an SSR for AC loads.

Collector-emitter voltage (VCEO)

This is a rating for an output semiconductor that used in an SSR for DC loads.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

221

Page 223

Solid-State Relays

Terms

Meaning Operating (pick-up) time

A time lag between the moment a specified signal voltage is imposed to the input terminals and the output is turned ON.

Release (drop-out) time

A time lag between the moment the imposed signal input is turned OFF and the output is turned OFF.

Insulation resistance

The resistance between the input and output terminals or I/O terminals and metal housing (heat sink) when DC voltage is imposed.

Dielectric strength

The effective AC voltage that the SSR can withstand when it is applied between the input terminals and output terminals or I/O terminals and metal housing (heat sink) for more than 1 minute.

Ambient temperature and humidity (operating)

The ranges of temperature and humidity in which the SSR can operate normally under specified cooling, input/output voltage, and current conditions.

Storage temperature

The temperature range in which the SSR can be stored without voltage imposition.

Inrush current resistance

A current, which can be applied for short periods of time to the electrical element.

Counter-electromotive force

Extremely steep voltage rise which occurs when the load switched or turned OFF.

Characteristics

The recommended load capacity which takes into account the safety factors of ambient temperature and inrush Recommended applicable load current.

Others

The resistance connected in parallel to the load in order to increase apparently small load currents, so that the ON/OFF of minute currents functions normally. (It is also used to shunt leakage currents.)

Bleeder resistance

Solid-state Relay Switching Capacity

Relay Type

Equivalent EM Relay Contact Configuration

700-SA

Form A

700-SC Solid-State

700-SF

Form A

700-SH *

Form A

700-S KO

IMPORTANT

222

Form A

Form A

Load Voltage

Maximum AC an d DC Switching Capability Load Zero-Cross Switching 1 mA 10 mA 50 mA 100 mA 1 A 3A 5A 10 A 2 0 A 25 A Device

AC

Yes

Triac

DC

N/A

Transistor

AC

Yes

Triac

DC

N/A

Transistor

AC

Yes

Triac

DC

N/A

Transistor Thyristor or Triac Transistor

AC

Yes

DC

N/A

AC

Yes

Triac

DC

N/A

Transistor

(2 A)

(2 A)

* Requires a heat sink to reach maximum current value.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

30 A

35 A

100 A

Page 224

Solid-State Relays

700-SA Tube Base Relays • 5 A (resistive) max. continuous load (output) current • 264V AC or 125V DC max. load voltage options • Photocoupler isolation between control and load voltage • LED indicator (standard) for input/logic ON/OFF status monitoring • 700-HN100, -HN125, -HN 202, or -HN108 specialty socket compatible • 700-HT2 timing module Input-to-Output Isolation Method Photocoupler

Zero Cross Function Yes

Status Indicator

Yes

Not Applicable

Output (Load) Max. Continuous Current and Rated Voltage Range

Rated Input (Control) Voltage

5 A @ 100…240V AC (47…63 Hz)

5…24V DC

Cat. No. 700-SAZY5Z25

3 A @ 5…110V DC

700-SANY3Z25

Accessories - 700-SA Relays Photo

Description

Pkg. Quantity

Cat. No.

10

700-HN100

10

700-HN108

10

700-HN125

10

199-DR1

Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N40

Blank Identification Tags, contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N41

10

700-HN158

10

700-HN204

Screw Terminal Tube Base Socket, Panel or DIN Rail Mounting; Guarded Terminal Construction. 8 Pin for use with DPDT 700-HA Relays.

Specialty Socket 8 Pin back wired socket with solder terminals

Screw Terminal Tube Base Socket, Panel or DIN Rail Mounting; Open Style Construction. 8 Pin for use with DPDT 700-HA Relays. No retainer clip required.

DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m

Retainer Clip for Sockets with 700-SA AND 700-HB Relays. Secures relay in socket.

8-Pin Socket, Can Be Used With or Without Timing Module or Surge Suppressor. Screw Terminal Tube Base Sockets, panel or DIN Rail mounting. Guarded terminal construction. Used with DPDT 700-HA Relays.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

223

Page 225

Solid-State Relays

Specifications - 700-SA Relays Control/Input Ratings Cat. No.

700-SAZY5Z25 700-SANY3Z25

Rated Control Voltage

Max. Operating Control Voltage Range

Max. Reverse Control Voltage

Impedance

4…32V DC

-32V DC

15 mA max. (1)

4…30V DC

-30V DC

1.5 kΩ (+20% -10%)

5…24V DC

Control Voltage Levels Pick-up Voltage Drop-out Voltage 4V DC max.

1V DC min.

Load/Output Ratings Cat. No.

Rated Load Voltage

Maximum Load Voltage Range

Continuous Load Current (Resistive) [A] Min. Max. (2)

700-SAZY5Z25

100…240V AC

75…264V AC

0.1

5.0

700-SANY3Z25

5…110V DC

3…125V DC

0.1

3.0

Max. Inrush Current (3) 80 A, @ 50/60 Hz for 1 cycle 12 A (10 ms)

Characteristics Description Load Switching Method/Device Pick-up Time Drop-out Time Output ON Voltage Drop Output Leakage Current

Cat. No. 700-SAZY5Z25 Cat. No. 700-SANY3Z25 Triac Transistor 0.5 ms max. 1/2 cycle of load power source cycle time (4) + 1 ms max. 1/2 cycle of load power source cycle time (4) + 1 ms max. 2.5 ms max. 1.6V (RMS) max. 1.5V max. 5 mA max. (at 100V AC); 10 mA max. (at 200V AC) 5 mA max. (at 125V DC) 600 150 50, 500, 41.6, 125 150 100 MΩ min. (at 500V DC) 1500V AC, 50/60 Hz for 1 min 10…55 Hz, 1.5 mm double amplitude (10 G) 1000 m/s2 (100 G) –30…80 °C (–22…176 °F) with no icing or condensation –30…100 °C (–22…212 °F) with no icing or condensation 45…85% (no condensation) UL 508, CSA C22.2 No. 14, EN 60947-1, -4-3 cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified Approx. 70 g

Output VDRM VCEO (V)

Output di/dt (V/uS) Output dv/dt (V/uS) Output I2t (A2S) Output Tj (ºC) Max. Insulation Resistance Dielectric Strength Vibration Resistance (Max.) Shock Resistance (max.) Ambient Temperature

Operating Storage

Ambient Humidity Standards Compliance Certifications Weight

With constant current input system. SSR input impedance varies with a change in input (control) voltage. See the following graph “Load Current Vs. Ambient Temperature Characteristics” for additional load current details. If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See “Inrush Current Resistivity” graph. 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time = 20 ms.

Inrush Current Resistivity (1)

Load Current vs. Ambient Temperature Characteristics 700-SA

700-SA 80

2 1

50 40

700-SAZY5Z25

30 20 10 500

700-SANY3Z25 100

0

200

80

Ambient Temperature [° C]

100

40

60

20

0

-30 -20

0

5000

700-SANY3Z25 3

30 50

Load Current [A]

4

70 60

1000

Inrush Current [A. Peak]

700-SAZY5Z25 5

10

(1) (2) (3) (4)

Energizing Time [ms]

(1) Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.

224

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 226

Solid-State Relays

Terminal Arrangement (Bottom View)

Load

Load

Load power supply

Input

Input voltage Note: The plus and minus symbols shown in parentheses are for DC loads.

Basic Application Considerations High Density Mounting of Multiple Solid-state Relays (SSRs) If multiple SSRs are installed side by side,, the outer case wall of the SSR serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current to half.

Protective Component When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in surge suppression (s 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device. Select a varistor that meets the conditions of the load voltage that is outlined in the table. Load Voltage

Varistor Voltage [V]

100…120V AC

240…270

200…240V AC

440…470

380…480V AC

820…1000

TIP

Varistor Surge Resistance

1000 A min.

For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.

For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load. EMC Directive Compliance 1. AC-switching models comply with EMC Directives under the following conditions:

Load Load power supply

SSR

Input

3 m max. Load Input

700-SA Output

Varistor: 470 V, 0.6 W Film Capacitor: 1µ F, 250 VAC

Varistor

Film Capacitor

• Connect a varistor between the output terminals. • Connect a film capacitor to the load power supply. • The input cable must be less than 3 m. 2. DC-switching models comply with EMC Directives under the following conditions: Less than 10 m Load Input

700-SA Output

• The input cable must be less than 10 m.

Dimensions - 700-SA Relays

All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for manufacturing purposes. 700-SA (1)

+ 35 max.

+ 35 max. (1)

52.5 max.

700-SA is compatible with Cat. Nos. 700-HN100, -108, -125, and -204 (sockets).

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

225

Page 227

Solid-State Relays

700-SC Ice Cube Relays • 3 A (resistive) max. continuous load (output) current • 264V AC, 48V DC or 125V DC max. load voltage options • 5…24V DC or 110/220V AC control (input) voltage options • LED indicator (optional) for input/logic On/Off status monitoring • 700-HN103, 700-HN104, or 700-HN128 socket compatible • Compatible with 700-AT1 or 700-AT2 timer modules Input-to-Output Isolation Method

Photocoupler

Zero Cross Function

Status Indicator

Yes

Photocoupler

Rated Input (Control) Voltage

Cat. No.

3 A @ 100…240V AC(1)

5…24V DC

700-SCZY3Z25

100/110V AC

700-SCZY2A1

2 A @ 100…240V AC(1)

200/220V AC

700-SCZY2A2

No

3 A @ 100…240V AC (1)

24V DC

700-SCTY3Z24

Not Applicable

3 A @ 4…48V DC

5…24V DC

700-SCNY3Z25

4…24V DC

700-SCZN3Z26

24V DC

700-SCTN3Z24

3 A @ 4…48V DC

4…24V DC

700-SCNN3Z26

2 A @ 5…110V DC

5…24V DC

700-SCNN2Z25

Yes Phototriac

Output (Load) Max. Continuous Current and Rated Voltage Range

Yes

Phototriac

No

Photocoupler

Not Applicable

3 A @ 100…240V AC (1) No

(1) 47…63 Hz

Accessories - 700-SC Relays Photo

226

Description

Pkg. Quantity

Cat. No.

Screw Terminal Socket, Panel or DIN Rail Mounting; Guarded Terminal Construction.Ith = 10 A per pole. 14-blade miniature socket for use with 700-SC Relays.

10

700-HN103

Screw Terminal Socket, Panel or DIN Rail Mounting; Guarded Terminal Construction Ith = 10 A per pole. 14-blade miniature socket for use with 700-SC relays. This socket has coil and contact separation and the ability to plug in optional plug-in modules (700-A__ accessories: LED, Surge Suppression, Timing Modules)

10

700-HN104

Screw Terminal Base Socket, Panel or DIN Rail Mounting; Open-Style Construction Ith = 10 A per pole. 14-blade miniature socket for use with 700-SC Relays.

10

700-HN128

DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m

10

199-DR1

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 228

Solid-State Relays

Photo

Description

Pkg. Quantity

Cat. No.

Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N40

Blank Identification Tags, contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N41 (1)

Retainer Clip for Cat. Nos. 700-HN103, -HN104, and -HN128 Sockets with 700-HC Relays. Secures relay in socket.

10

700-HN114

(1) Series B retainer clip must be used with 700-SC

Specifications- 700-SC Relays Control/Input Ratings Max. Reverse Control Voltage [V]

Impedance

700-SCTY3Z24

5…24V DC 100/110V AC 200/220V AC 24V DC

Max. Operating Control Voltage Range 4…28V DC 75…125V AC 150…250V AC 19.2…28.8V DC

-28.8 NA NA -28.8

4V DC max. 75V AC max. 150V AC max. 19.2V DC max.

700-SCNY3Z25

5…24V DC

4…28V DC

-28

15mA max.(1) 41 kΩ ±20% 72 kΩ ±20% 2 kΩ ±20% 1.5 kΩ +20%/ -10% (2)

4V DC max.

15mA max. (1) 2 kΩ ±20%

3V DC max. 19.2V DC max.

1.5 kΩ +20%/ -10%

3V DC max.

Cat. No.

Rated Control Voltage

700-SCZY3Z25 700-SCZY2A1 700-SCZY2A2

700-SCZN3Z26 700-SCTN3Z24 700-SCNN3Z26 700-SCNN2Z25

4…24V DC 24V DC 4…24V DC 5…24V DC

3…28V DC 19.2…28.8V DC 3…28V DC

-28.8 -28.8 -28 -28.8

(2)

Control Voltage Levels Pick-up Voltage Drop-out Voltage 1V DC min. 20V AC min. 40V AC min.

1V DC min.

Load/Output Ratings Cat. No.

Rated Control Voltage

Max. Load Voltage Range

100…240V AC

75…264V AC

Continuous Load Current (Resistive) [A] Min. Max. (3)

Max. Inrush Current (4)

700-SCZY3Z25 700-SCTY3Z24 700-SCZN3Z26 700-SCTN3Z24

0.1

700-SCZY2A1 700-SCZY2A2 700-SCNN3Z26 700-SCNY3Z25 700-SCNN2Z25 (1) (2) (3) (4)

3 45 A (@50/60 Hz, 1 cycle)

0.1

2

4…48V DC

3…52.8V DC

0.1

3

18 A (10 ms)

5…110V DC

3…125V DC

0.1

2

10 A (10 ms)

With constant current input circuit system. SSR impedance varies with a change in input (control) voltage. Input impedance attains its maximum at the operating voltage. If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See “Inrush Current Resistivity” graphs on page 112 for details See the following “Load Current Versus Ambient Temperature Characteristics” graphs on page 112 for additional load current details.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

227

Page 229

Solid-State Relays

Characteristics Description

Cat. No. 700-SCZ…

Load Switching Method/Device

Pick-up time

Drop-out time Output On Voltage Drop Output Leakage Current Output VDRM, VCEO (V) Output di/dt (A/uS) Output dv/dt (V/uS) Output I2t (A2S) Output Tj (°C) Max. Insulation Resistance Dielectric Strength Vibration Resistance (max.) Shock Resistance (max.) Ambient Temperature Standards Compliance Certifications Ambient Humidity Weight

Cat. No. 700-SCT

Cat. Nos. 700-SCNY, 700Cat. Nos. 700-SCNN2… SCNN3… Transistor

Triac 1/2 of load power source cycle time (1) + 1 ms max. (DC input) 3/2 of load power source cycle time (1) + 1 ms max. (AC input) 1/2 of load power source cycle time (1) + 1 ms max. (DC input) 1/2 of load power source cycle 2 ms max. 2.5 ms max. time (1) + 1 ms max. 3/2 of load power source cycle (1) time + 1 ms max. (AC input) 1.6V (RMS) max. 1.6V (RMS) 1.5V max. 1.5V max. 5 mA max (@ 100V AC) 2.5 mA max (@ 100V AC) 5 mA max (@ 50V DC) 0.1 mA max (@ 100V DC) 10 mA max (@ 200V AC) 5 mA max (at 200V AC) 600 600 80 80 50 50, - 250 250, - 18 18, - 125 125 150 150 100 MΩ min (@500V DC) 1500V AC, 50/60 Hz for 1 minute 10…55 Hz, 1.5 mm double amplitude (10 G) 1000 m/s2 (100 G) Operating: -30…+80 °C (-22...+176 °F) with no icing or condensation Storage: -30…+100 °C (-22...+212 °F) with no icing or condensation UL 508, CSA C22.2 No. 14, EN/IEC 60950, EN 50011, EN 61000-6-2, EN/IEC 60947-1, -4-3 cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified Operating: 45…85% (no condensation) Approx. 50 g

(1) 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time = 20 ms

Load Current Versus Ambient Temperature Characteristics

700-SC_ _2... 5

4

4

Ambient Temperature [° C]

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

100

80

60

40

100

80

60

0 40

0 20

1

0

1

Ambient Temperature [° C]

228

2

20

2

3

0

3

-30 -20

Load Current [A]

5

-30 -20

Load Current [A]

700-SC_ _3...

Page 230

Solid-State Relays

Inrush Current Resistivity (1) 700-SCNN3...

8 6 4

5000

3000

1000

300 500

0

100

2

20 30 50

Inrush Current [A. Peak] Energizing Time [ms]

Energizing Time [ms]

10

10

5000

500

1000

200

10

0

100

10

2000

20

700-SCNN2... 12

1000

30

700-SCNY3

200 300 500

Inrush Current [A. Peak]

40

30 50

Inrush Current [A. Peak]

50

30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0

20 30 50 70 100

700-SCT...

10

700-SCZ....

Energizing Time [ms]

(1) Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.

EMC Directive Compliance 1. AC-switching models comply with EMC Directives under the following conditions 3 m max. Load Input

700-SC

Varistor: 470 V, 0.6 W Film capacitor: 1µ F, 250 VAC

Output

Varistor

Film capacitor

• Connect a varistor between the output terminals. • Connect a film capacitor to the load power supply. • The input cable must be less than 3 m.

2. DC-switching models comply with EMC Directives under the following conditions Less than 10 m Load Input

700-SC

Output

• The input cable must be less than 10 m.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

229