Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a spec sheet · part 7 of 25

Relay and Timer Specifications, Bulletin Number 700, pages 61 to 70

Pages 61 to 70 of 250

The original document is the PDF (23 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 700-HA33Z24, Allen-Bradley 700-HN153, Allen-Bradley 700-HA32Z24 and Allen-Bradley 700-HX

Page 61

General Purpose Relays

Function and Connection Diagrams - 700-HLF Relays

15

A1 U (A1/A2)

1 c/o (SPST) t

R LED

A2

18 16

A1

15

On-Delay

U (A1/A2)

1 c/o (SPST) t

R LED

A2

18 16

A1

15

One Shot

U (A1/A2)

1 c/o (SPST) t

R 0.5s LED

A2

18 16

A1

15

Pulse

1 c/o (SPST)

U (A1/A2)

t t t

R LED

A2

18 16

Flasher

Specifications- 700-HLF Relays Cat. No. 700-HLF… (Relay Output) (1) Electrical Ratings

Pilot Duty Rating

B 300, R 300

Rated Thermal Current (Ith)

1-Pole, 6 A

Rated Insulation Voltage (Ui)

250V IEC, 300V UL/CSA Inductive

Contacts

24V AC, 1-phase

30 A

5A

120V AC, 1phase

30 A

3A

240V AC, 1phase

15 A

1.5 A

Make, Break and Continuous V DC

Inductive Load Min. Permissible Contact Ratings

1-Pole

24V DC

1.0 A

120V DC

0.2 A

240V DC

0.1 A

AC-15 250V, 3 A N.O. Contact, 1.5 A N.C. Contact DC-13 24V, 1 A N.O. and N.C. Contact 12V, 6 mA (72 mW) for Silver Contacts, 8V, 2.5 mA (20 mW) for Gold Contacts

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

61

Page 62

General Purpose Relays

Permissible Coil Voltage Variation

Pickup:

Power Consumption ±10%

AC/DC

85…110% of Nominal Voltage at 50 Hz 85…110% of Nominal Voltage at 60 Hz 80…110% of Nominal Voltage at DC

Must Dropout Voltage:

10% of Nominal Voltage at AC, 5% of Nominal Voltage at DC

0.5 VA Design Specification/Test Requirements

Dielectric Withstand Voltage

Pole to Pole (VRMS)

1000V

Contact to Coil (VRMS)

4000V

Input Voltage

24V AC/DC

Impedance (Ohms)

2K Mechanical

Degree of Protection

IP20

Mechanical Life Operations

1 x 107

Electrical Life Operations

6 A Resistive: 100 000 min. 24V DC, 1 A Inductive: 200 000 min. 120V AC 1 A Inductive: 300 000 min.

Switching Frequency Operations (no-load)

10 cycles/sec

Coil Voltages

See Overview/Product Selection

Timer Functions

On-Delay, One Shot, Pulse, and Flasher

Timer Settings

0.1...3 s, 3...60 s, 1...20 min, and 0.3...6 hr

Timer Adjustments

Min and Max adjustments with Potentionmeter

Timer Accuracy

Repeatability 1%, Recovery Time < 50 ms, Setting Accuracy Full Range 5%

Coil Surge Protection

Per EN 61000-4.5; Surge Immunity (801-5) Class III: 2 kV common and 1 kV differential mode Environmental

Temperature

Operating

–40…+55 °C

Storage

–40…+100 °C

Altitude

2000 m (6560 ft) Construction

Insulating Material Enclosure Contact Material Terminal Markings on Socket

Molded High Dielectric Material Relay IP67 Silver Tin Ox, AgSnO2 or Silver with Gold Plating, AgSnO2 + Au In accordance with EN50 0005

Certifications cULus Listed (File No. E3125, Guide NLDX/NLDX7) with Allen-Bradley socket, CE Marked

Standards

EN60947-4-1,EN60947-5-1,CSA 22.2,UL 508,NEMA IEE MAC Compliant, ICS-2 Compliant

(1) Product shall be installed in an enclosure providing at least IP54 protection. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%.

62

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 63

General Purpose Relays

Dimensions- 700-HLF Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.

76.0 (2.99)

6.20 (0.24)

88.0 (3.46)

700-HLF Screw Terminal Design Single Wire: 0.14 mm2…2.5 mm2 (#26 AWG…14 AWG) Double Wire: 2 x 0.14 mm2…2 x 1.5 mm2 (2 x #26 AWG…2 x 16 AWG) Wire Type: Solid or stranded, copper only Strip Length: 9 mm (11/32 in.). Torque: 0.5 N•m (4.4 lb•in)

5.2 (13/64)

12.5 (1/2)

6.2 (15/64)

50 (1-63/64)

1.0 (0.04)

35.0 (1.38)

27.0 (1.06)

7.5 (0.3)

1000 (39-3/8)

Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes

Cat. No.

A

B

C

D

Approx. Shipping Wt.

199-DR1

35 (1-3/8)

27 (1-1/16)

7.5 (19/64)

1.02 (1/64)

1.85 kg (4.07 lb) (10/pkg)

199-DR4

35 (1-3/8)

27 (1-1/16)

15 (19/32)

2.3 (3/32)

3.68 kg (8 lb) (5/pkg)

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

63

Page 64

General Purpose Relays

700-HP Slim Line Relay • 8 A contact ratings • DPDT/ (2 c/o) contacts • Plug-in PIN style (PCB) terminals (5 mm pinning) • Choice of standard silver nickel contacts, or silver nickel with gold-plated contacts • Available with mechanically linked contacts (Type B) • Safety Control Relay Version (700-HPS) Photo

Description

Contact Rating

Wiring Diagrams U.S./Canada

International

DPDT 2-Pole 2 Form C AgNi + Au Gold Plated Contacts

8A

DPDT 2-Pole 2 Form C AgNi Contacts

Sockets

64

700-HN123

700-HN123

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Coil Voltage

Pkg. Qty.

Cat. No.

6V AC

10

700-HPX2A06

12V AC

10

700-HPX2A12

24V AC

10

700-HPX2A24

120V AC

10

700-HPX2A1

240V AC

10

700-HPX2A2

6V DC

10

700-HPX2Z06

12V DC

10

700-HPX2Z12

24V DC

10

700-HPX2Z24

48V DC

10

700-HPX2Z48

110V DC

10

700-HPX2Z1

6V AC

10

700-HP32A06

12V AC

10

700-HP32A12

24V AC

10

700-HP32A24

120V AC

10

700-HP32A1

240V AC

10

700-HP32A2

6V DC

10

700-HP32Z06

12V DC

10

700-HP32Z12

24V DC

10

700-HP32Z24

48V DC

10

700-HP32Z48

110V DC

10

700-HP32Z1

Page 65

General Purpose Relays

700-HPS Safety Control Relay Photo

Description

Contact Rating

Wiring Diagrams U.S./Canada

International

DPDT 2-Pole 2 Form C AgNi + Au Gold Plated Mechanically Linked Contacts

8A

DPDT 2-Pole 2 Form C AgNi Mechanically Linked Contacts

700-HPS DPDT

Sockets

700-HN123

700-HN123

Coil Pkg. Voltage Qty.

Cat. No.

6V DC

10

700-HPSXZ06

12V DC

10

700-HPSXZ12

24V DC

10

700-HPSXZ24

48V DC

10

700-HPSXZ48

60V DC

10

700-HPSXZ60

110V DC

10

700-HPSXZ1

125V DC

10

700-HPSXZ01

6V DC

10

700-HPS2Z06

12V DC

10

700-HPS2Z12

24V DC

10

700-HPS2Z24

48V DC

10

700-HPS2Z48

60V DC

10

700-HPS2Z60

110V DC

10

700-HPS2Z1

125V DC

10

700-HPS2Z01

Accessories - 700-HP, -HPS Photo

Description

Pkg. Qty.

Cat. No.

Diode Surge Suppressor Voltage Range: 6…220V DC used with 700-HN123 socket

10

700-ADR

Diode with LED Surge Suppressor Voltage Range: 6…24V DC used with 700-HN123 socket

10

700-ADL1R

Diode with LED Surge Suppressor Voltage Range: 28…60V DC used with 700-HN123 socket

10

700-ADL2R

Diode with LED Surge Suppressor Voltage Range: 110…220V DC used with 700-HN123 socket

10

700-ADL3R

Diode with LED Surge Suppressor Voltage Range: 6…24V AC used with 700-HN123 socket

10

700-AV1R

Varistor with LED Surge Suppressor Voltage Range: 110…240V AC used with 700-HN123 socket

10

700-AV3R

RC Surge Suppressor Voltage Range: 6…24V AC/DC used with 700-HN123 socket

10

700-AR1

RC Surge Suppressor Voltage Range: 110…240V AC/DC used with 700-HN123 socket

10

700-AR2

Timing Module On-Delay or One-Shot selectable voltage range: 12…24V AC/DC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 110…125V AC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 230…240V AC used with sockets that accept plug-in accessory modules.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

700-AT3

1

700-AT3A1

700-AT3A2

65

Page 66

General Purpose Relays

Photo

Description

Pkg. Qty.

Cat. No.

Screw Terminal Socket, Panel or DIN Rail Mounting 8-pin miniature socket for use with 2-pole, 700-HP relays. Incorporates coil and contact separation.

10

700-HN123

Color 8-Way Jumper can be cut to required length. Rated 10 A – 250V

1

Red Gray Blue

Plastic Retainer and Ejection Lever For use with the 700-HN123 sockets Built-in ability to accept 1492 snap-in markers

10

700-HN119

Spring Clamp Terminal Socket, Panel or DIN Rail Mounting 8-pin miniature socket for use with 2-pole, 700-HP relays. Incorporates coil and contact separation.

10

700-HN230

Plastic Retainer and Ejection Lever For use with the 700-HN230 sockets Built-in ability to accept 1492 snap-in markers

10

700-HN232

DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m

10

199-DR1

5

1492-MS5X12

5

1492-MS6X9

5

1492-MS6X12

5

1492-MS8X9

5

1492-MS8X12

100

1492-MP-Blank

Relay Identification Snap-in Markers Note - These markers can only be used when the Plastic Retainer and Ejection Lever accessory (part # 700HN119) is used because the markers snap into the Ejection Lever (and not into the relay itself).

700-N40

Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

Socket, and Retainer Clip Reference Relay Type

Socket Cat. No.

Retainer Clip Cat. No.

700-HPX2

700-HN123

700-HN119

66

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

10

700-N41

Page 67

General Purpose Relays

Socket, and Retainer Clip Reference 700-HP32

700-HN123

700-HN119

700-HPS2

700-HN123

700-HN119

700-HPSX

700-HN123

700-HN119

Specifications (1) - 700-HP Relays Cat. No. 700-HP…

Cat. No. 700-HP3…, 700-HPX

Cat. No. 700-HPS…

AC 15 @ 500V AC

V AC

C300

B300

1/3 Hp @ 240V AC

1/2 Hp @ 240V AC

1/6 Hp @ 120V AC

1/3 Hp @ 120V AC

Inductive

AC-1 2000VA R300, Contacts V DC

Resistive

DC-1: 8A @ 30V DC DC-1: 0.3A @ 110V DC

DC-1: 0.65A @ 110V DC

DC-1: 0.1A @ 220V DC

DC-1: 0.2A @ 220V DC

AC

8 A @ 277V AC (per pole)

DC

8 A @ 30V DC (per pole) 700-HP32: 300mW (5V, 5 mA) 700-HPX2: 50mW (5V, 5 mA)

700-HPS2: 500 mW (10V, 10 mA) 700-HPSX: 50 mW (5V, 5 mA)

Nominal Coil Power (AC/DC)

1.2 VA / 0.65 W

0.7 W

Operating Range (AC/DC)

80...110% / 73...150% Nominal Voltage

75...120% Nominal Voltage DC

Holding Voltage (AC/DC)

80 / 40% Nominal Voltage

40% Nominal Voltage DC

Must Drop Out Voltage (AC/DC)

20 / 10% Nominal Voltage

10% Nominal Voltage DC

Minimum Load

Insulation Voltage

250V AC

Design Specification/Test Requirements Dielectric Withstand Voltage for 1 minute

700-HP3, 700-HPX

700-HPS

Pole to Pole (VRMS)

2000V AC

Contact to Coil (VRMS)

4000V AC

Mechanical Degree of Protection

Open Type (Sockets) 6

Mechanical lifecycles Switching Frequency Operations

10 x 10 (AC Coils), 20 x 106 (DC coils)

10 x 106 (DC Coils)

1800/hr (no load)

900/hr (no load)

Coil Voltages Operating Time at Nominal Voltage at 20 °C (ms)

See Overview/Product Selection Pickup Dropout

Maximum Operating Rate Vibration

Shock

12

10 4

16 Ops/s (full load)

8 Ops/s (full load)

Enclosure

5G

Fragility

2.5 G

Endurance

50 G

Fragility

15 G

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

67

Page 68

General Purpose Relays

Specifications (1) - 700-HP Relays Max. Socket Torque

0.5 N•m (4.4 lb•in)

Environmental Temperature

Operating

–40…+85 °C

–40…+70 °C

Storage

–45…+100 °C

–50…+80 °C

Altitude

2000 m (6560 ft)

Construction Insulating Material Enclosure Contact Material

Molded High-Dielectric Material Transparent Dust Cover

Red Transparent Dust Cover

Silver Nickel, (AgNi) (700-HP32 and 700-HPS2), Silver Nickel + Gold Plating (AgNi + Au) (700-HPX2 and 700-HPSX)

Terminal Markings on Socket

In accordance with EN50 0005 2-Pole

Sockets

700-HN123

Approvals Certifications cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN123 socket (File No. E3125, Guide NLDX/NLDC7), CSA Certified (files 229473), CE Marked, LR Certified (700-HP), IMQ & TÜV Certified (700- HPS)

Standards

UL 508, CSA 22.2 No. 14, EN 61810-1, EN 50205 (700-HPS)

(1) The inrush VA equals 1.5 times the sealed VA.

68

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 69

General Purpose Relays

Dimensions - 700-HP Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.

29.0 (1.14)

12.4 (0.49)

25.0 (0.98)

700-HP Relay

5.2 (13/64)

12.5 (1/2)

6.2 (15/64)

50 (1-63/64)

1.0 (0.04)

35.0 (1.38)

27.0 (1.06)

7.5 (0.3)

1000 (39-3/8)

Cat. No. 700-HN123 Single Wire: 0.2.....2.5 mm2 (#24.....14 AWG) Double Wire: 2 X 0.2.....2 X 2.5 mm2 (#2 X 24....2 X 14 AWG) Wire Type: solid or stranded, copper only Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)

Cat. No.

A

B

C

D

Approx. Shipping Wt.

199-DR1

35 (1-3/8)

27 (1-1/16)

7.5 (19/64)

1.02 (1/64)

1.85 kg (4.07 lb) (10/pkg)

199-DR4

35 (1-3/8)

27 (1-1/16)

15 (19/32)

2.3 (3/32)

3.68 kg (8 lb) (5/pkg)

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

69

Page 70

General Purpose Relays

Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.

21 6

11 3

24 5

14 4

22 7

12 2

17.5 (0.69)

60.9 (2.40) 17.5 (0.69)

Ø 3.2 (0.12) Use M3 Screws

78.6 (3.09)

8 (+) A1

1 (-) A2

4.0 (0.16) 15.8 (0.62)

Cat. No. 700-HN123 Single Wire: 0.2.....2.5 mm2 (#24.....14 AWG) Double Wire: 2 X 0.2.....2 X 2.5 mm2 (#2 X 24....2 X 14 AWG) Wire Type: solid or stranded, copper only Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)

70

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

21.6 (0.85)

35.4 (1.39)

21.6 (0.85)