Page 61
General Purpose Relays
Function and Connection Diagrams - 700-HLF Relays
15
A1 U (A1/A2)
1 c/o (SPST) t
R LED
A2
18 16
A1
15
On-Delay
U (A1/A2)
1 c/o (SPST) t
R LED
A2
18 16
A1
15
One Shot
U (A1/A2)
1 c/o (SPST) t
R 0.5s LED
A2
18 16
A1
15
Pulse
1 c/o (SPST)
U (A1/A2)
t t t
R LED
A2
18 16
Flasher
Specifications- 700-HLF Relays Cat. No. 700-HLF… (Relay Output) (1) Electrical Ratings
Pilot Duty Rating
B 300, R 300
Rated Thermal Current (Ith)
1-Pole, 6 A
Rated Insulation Voltage (Ui)
250V IEC, 300V UL/CSA Inductive
Contacts
24V AC, 1-phase
30 A
5A
120V AC, 1phase
30 A
3A
240V AC, 1phase
15 A
1.5 A
Make, Break and Continuous V DC
Inductive Load Min. Permissible Contact Ratings
1-Pole
24V DC
1.0 A
120V DC
0.2 A
240V DC
0.1 A
AC-15 250V, 3 A N.O. Contact, 1.5 A N.C. Contact DC-13 24V, 1 A N.O. and N.C. Contact 12V, 6 mA (72 mW) for Silver Contacts, 8V, 2.5 mA (20 mW) for Gold Contacts
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
61
Page 62
General Purpose Relays
Permissible Coil Voltage Variation
Pickup:
Power Consumption ±10%
AC/DC
85…110% of Nominal Voltage at 50 Hz 85…110% of Nominal Voltage at 60 Hz 80…110% of Nominal Voltage at DC
Must Dropout Voltage:
10% of Nominal Voltage at AC, 5% of Nominal Voltage at DC
0.5 VA Design Specification/Test Requirements
Dielectric Withstand Voltage
Pole to Pole (VRMS)
1000V
Contact to Coil (VRMS)
4000V
Input Voltage
24V AC/DC
Impedance (Ohms)
2K Mechanical
Degree of Protection
IP20
Mechanical Life Operations
1 x 107
Electrical Life Operations
6 A Resistive: 100 000 min. 24V DC, 1 A Inductive: 200 000 min. 120V AC 1 A Inductive: 300 000 min.
Switching Frequency Operations (no-load)
10 cycles/sec
Coil Voltages
See Overview/Product Selection
Timer Functions
On-Delay, One Shot, Pulse, and Flasher
Timer Settings
0.1...3 s, 3...60 s, 1...20 min, and 0.3...6 hr
Timer Adjustments
Min and Max adjustments with Potentionmeter
Timer Accuracy
Repeatability 1%, Recovery Time < 50 ms, Setting Accuracy Full Range 5%
Coil Surge Protection
Per EN 61000-4.5; Surge Immunity (801-5) Class III: 2 kV common and 1 kV differential mode Environmental
Temperature
Operating
–40…+55 °C
Storage
–40…+100 °C
Altitude
2000 m (6560 ft) Construction
Insulating Material Enclosure Contact Material Terminal Markings on Socket
Molded High Dielectric Material Relay IP67 Silver Tin Ox, AgSnO2 or Silver with Gold Plating, AgSnO2 + Au In accordance with EN50 0005
Certifications cULus Listed (File No. E3125, Guide NLDX/NLDX7) with Allen-Bradley socket, CE Marked
Standards
EN60947-4-1,EN60947-5-1,CSA 22.2,UL 508,NEMA IEE MAC Compliant, ICS-2 Compliant
(1) Product shall be installed in an enclosure providing at least IP54 protection. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%.
62
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
Page 63
General Purpose Relays
Dimensions- 700-HLF Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
76.0 (2.99)
6.20 (0.24)
88.0 (3.46)
700-HLF Screw Terminal Design Single Wire: 0.14 mm2…2.5 mm2 (#26 AWG…14 AWG) Double Wire: 2 x 0.14 mm2…2 x 1.5 mm2 (2 x #26 AWG…2 x 16 AWG) Wire Type: Solid or stranded, copper only Strip Length: 9 mm (11/32 in.). Torque: 0.5 N•m (4.4 lb•in)
5.2 (13/64)
12.5 (1/2)
6.2 (15/64)
50 (1-63/64)
1.0 (0.04)
35.0 (1.38)
27.0 (1.06)
7.5 (0.3)
1000 (39-3/8)
Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
Cat. No.
A
B
C
D
Approx. Shipping Wt.
199-DR1
35 (1-3/8)
27 (1-1/16)
7.5 (19/64)
1.02 (1/64)
1.85 kg (4.07 lb) (10/pkg)
199-DR4
35 (1-3/8)
27 (1-1/16)
15 (19/32)
2.3 (3/32)
3.68 kg (8 lb) (5/pkg)
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
63
Page 64
General Purpose Relays
700-HP Slim Line Relay • 8 A contact ratings • DPDT/ (2 c/o) contacts • Plug-in PIN style (PCB) terminals (5 mm pinning) • Choice of standard silver nickel contacts, or silver nickel with gold-plated contacts • Available with mechanically linked contacts (Type B) • Safety Control Relay Version (700-HPS) Photo
Description
Contact Rating
Wiring Diagrams U.S./Canada
International
DPDT 2-Pole 2 Form C AgNi + Au Gold Plated Contacts
8A
DPDT 2-Pole 2 Form C AgNi Contacts
Sockets
64
700-HN123
700-HN123
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
Coil Voltage
Pkg. Qty.
Cat. No.
6V AC
10
700-HPX2A06
12V AC
10
700-HPX2A12
24V AC
10
700-HPX2A24
120V AC
10
700-HPX2A1
240V AC
10
700-HPX2A2
6V DC
10
700-HPX2Z06
12V DC
10
700-HPX2Z12
24V DC
10
700-HPX2Z24
48V DC
10
700-HPX2Z48
110V DC
10
700-HPX2Z1
6V AC
10
700-HP32A06
12V AC
10
700-HP32A12
24V AC
10
700-HP32A24
120V AC
10
700-HP32A1
240V AC
10
700-HP32A2
6V DC
10
700-HP32Z06
12V DC
10
700-HP32Z12
24V DC
10
700-HP32Z24
48V DC
10
700-HP32Z48
110V DC
10
700-HP32Z1
Page 65
General Purpose Relays
700-HPS Safety Control Relay Photo
Description
Contact Rating
Wiring Diagrams U.S./Canada
International
DPDT 2-Pole 2 Form C AgNi + Au Gold Plated Mechanically Linked Contacts
8A
DPDT 2-Pole 2 Form C AgNi Mechanically Linked Contacts
700-HPS DPDT
Sockets
700-HN123
700-HN123
Coil Pkg. Voltage Qty.
Cat. No.
6V DC
10
700-HPSXZ06
12V DC
10
700-HPSXZ12
24V DC
10
700-HPSXZ24
48V DC
10
700-HPSXZ48
60V DC
10
700-HPSXZ60
110V DC
10
700-HPSXZ1
125V DC
10
700-HPSXZ01
6V DC
10
700-HPS2Z06
12V DC
10
700-HPS2Z12
24V DC
10
700-HPS2Z24
48V DC
10
700-HPS2Z48
60V DC
10
700-HPS2Z60
110V DC
10
700-HPS2Z1
125V DC
10
700-HPS2Z01
Accessories - 700-HP, -HPS Photo
Description
Pkg. Qty.
Cat. No.
Diode Surge Suppressor Voltage Range: 6…220V DC used with 700-HN123 socket
10
700-ADR
Diode with LED Surge Suppressor Voltage Range: 6…24V DC used with 700-HN123 socket
10
700-ADL1R
Diode with LED Surge Suppressor Voltage Range: 28…60V DC used with 700-HN123 socket
10
700-ADL2R
Diode with LED Surge Suppressor Voltage Range: 110…220V DC used with 700-HN123 socket
10
700-ADL3R
Diode with LED Surge Suppressor Voltage Range: 6…24V AC used with 700-HN123 socket
10
700-AV1R
Varistor with LED Surge Suppressor Voltage Range: 110…240V AC used with 700-HN123 socket
10
700-AV3R
RC Surge Suppressor Voltage Range: 6…24V AC/DC used with 700-HN123 socket
10
700-AR1
RC Surge Suppressor Voltage Range: 110…240V AC/DC used with 700-HN123 socket
10
700-AR2
Timing Module On-Delay or One-Shot selectable voltage range: 12…24V AC/DC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 110…125V AC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 230…240V AC used with sockets that accept plug-in accessory modules.
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
700-AT3
1
700-AT3A1
700-AT3A2
65
Page 66
General Purpose Relays
Photo
Description
Pkg. Qty.
Cat. No.
Screw Terminal Socket, Panel or DIN Rail Mounting 8-pin miniature socket for use with 2-pole, 700-HP relays. Incorporates coil and contact separation.
10
700-HN123
Color 8-Way Jumper can be cut to required length. Rated 10 A – 250V
1
Red Gray Blue
Plastic Retainer and Ejection Lever For use with the 700-HN123 sockets Built-in ability to accept 1492 snap-in markers
10
700-HN119
Spring Clamp Terminal Socket, Panel or DIN Rail Mounting 8-pin miniature socket for use with 2-pole, 700-HP relays. Incorporates coil and contact separation.
10
700-HN230
Plastic Retainer and Ejection Lever For use with the 700-HN230 sockets Built-in ability to accept 1492 snap-in markers
10
700-HN232
DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m
10
199-DR1
5
1492-MS5X12
5
1492-MS6X9
5
1492-MS6X12
5
1492-MS8X9
5
1492-MS8X12
100
1492-MP-Blank
Relay Identification Snap-in Markers Note - These markers can only be used when the Plastic Retainer and Ejection Lever accessory (part # 700HN119) is used because the markers snap into the Ejection Lever (and not into the relay itself).
700-N40
Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
Socket, and Retainer Clip Reference Relay Type
Socket Cat. No.
Retainer Clip Cat. No.
700-HPX2
700-HN123
700-HN119
66
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
10
700-N41
Page 67
General Purpose Relays
Socket, and Retainer Clip Reference 700-HP32
700-HN123
700-HN119
700-HPS2
700-HN123
700-HN119
700-HPSX
700-HN123
700-HN119
Specifications (1) - 700-HP Relays Cat. No. 700-HP…
Cat. No. 700-HP3…, 700-HPX
Cat. No. 700-HPS…
AC 15 @ 500V AC
V AC
C300
B300
1/3 Hp @ 240V AC
1/2 Hp @ 240V AC
1/6 Hp @ 120V AC
1/3 Hp @ 120V AC
Inductive
AC-1 2000VA R300, Contacts V DC
Resistive
DC-1: 8A @ 30V DC DC-1: 0.3A @ 110V DC
DC-1: 0.65A @ 110V DC
DC-1: 0.1A @ 220V DC
DC-1: 0.2A @ 220V DC
AC
8 A @ 277V AC (per pole)
DC
8 A @ 30V DC (per pole) 700-HP32: 300mW (5V, 5 mA) 700-HPX2: 50mW (5V, 5 mA)
700-HPS2: 500 mW (10V, 10 mA) 700-HPSX: 50 mW (5V, 5 mA)
Nominal Coil Power (AC/DC)
1.2 VA / 0.65 W
0.7 W
Operating Range (AC/DC)
80...110% / 73...150% Nominal Voltage
75...120% Nominal Voltage DC
Holding Voltage (AC/DC)
80 / 40% Nominal Voltage
40% Nominal Voltage DC
Must Drop Out Voltage (AC/DC)
20 / 10% Nominal Voltage
10% Nominal Voltage DC
Minimum Load
Insulation Voltage
250V AC
Design Specification/Test Requirements Dielectric Withstand Voltage for 1 minute
700-HP3, 700-HPX
700-HPS
Pole to Pole (VRMS)
2000V AC
Contact to Coil (VRMS)
4000V AC
Mechanical Degree of Protection
Open Type (Sockets) 6
Mechanical lifecycles Switching Frequency Operations
10 x 10 (AC Coils), 20 x 106 (DC coils)
10 x 106 (DC Coils)
1800/hr (no load)
900/hr (no load)
Coil Voltages Operating Time at Nominal Voltage at 20 °C (ms)
See Overview/Product Selection Pickup Dropout
Maximum Operating Rate Vibration
Shock
12
10 4
16 Ops/s (full load)
8 Ops/s (full load)
Enclosure
5G
Fragility
2.5 G
Endurance
50 G
Fragility
15 G
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
67
Page 68
General Purpose Relays
Specifications (1) - 700-HP Relays Max. Socket Torque
0.5 N•m (4.4 lb•in)
Environmental Temperature
Operating
–40…+85 °C
–40…+70 °C
Storage
–45…+100 °C
–50…+80 °C
Altitude
2000 m (6560 ft)
Construction Insulating Material Enclosure Contact Material
Molded High-Dielectric Material Transparent Dust Cover
Red Transparent Dust Cover
Silver Nickel, (AgNi) (700-HP32 and 700-HPS2), Silver Nickel + Gold Plating (AgNi + Au) (700-HPX2 and 700-HPSX)
Terminal Markings on Socket
In accordance with EN50 0005 2-Pole
Sockets
700-HN123
Approvals Certifications cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN123 socket (File No. E3125, Guide NLDX/NLDC7), CSA Certified (files 229473), CE Marked, LR Certified (700-HP), IMQ & TÜV Certified (700- HPS)
Standards
UL 508, CSA 22.2 No. 14, EN 61810-1, EN 50205 (700-HPS)
(1) The inrush VA equals 1.5 times the sealed VA.
68
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
Page 69
General Purpose Relays
Dimensions - 700-HP Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
29.0 (1.14)
12.4 (0.49)
25.0 (0.98)
700-HP Relay
5.2 (13/64)
12.5 (1/2)
6.2 (15/64)
50 (1-63/64)
1.0 (0.04)
35.0 (1.38)
27.0 (1.06)
7.5 (0.3)
1000 (39-3/8)
Cat. No. 700-HN123 Single Wire: 0.2.....2.5 mm2 (#24.....14 AWG) Double Wire: 2 X 0.2.....2 X 2.5 mm2 (#2 X 24....2 X 14 AWG) Wire Type: solid or stranded, copper only Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)
Cat. No.
A
B
C
D
Approx. Shipping Wt.
199-DR1
35 (1-3/8)
27 (1-1/16)
7.5 (19/64)
1.02 (1/64)
1.85 kg (4.07 lb) (10/pkg)
199-DR4
35 (1-3/8)
27 (1-1/16)
15 (19/32)
2.3 (3/32)
3.68 kg (8 lb) (5/pkg)
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
69
Page 70
General Purpose Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
21 6
11 3
24 5
14 4
22 7
12 2
17.5 (0.69)
60.9 (2.40) 17.5 (0.69)
Ø 3.2 (0.12) Use M3 Screws
78.6 (3.09)
8 (+) A1
1 (-) A2
4.0 (0.16) 15.8 (0.62)
Cat. No. 700-HN123 Single Wire: 0.2.....2.5 mm2 (#24.....14 AWG) Double Wire: 2 X 0.2.....2 X 2.5 mm2 (#2 X 24....2 X 14 AWG) Wire Type: solid or stranded, copper only Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)
70
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
21.6 (0.85)
35.4 (1.39)
21.6 (0.85)