Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a spec sheet · part 9 of 25

Relay and Timer Specifications, Bulletin Number 700, pages 81 to 90

Pages 81 to 90 of 250

The original document is the PDF (23 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 700-HA33Z24, Allen-Bradley 700-HN153, Allen-Bradley 700-HA32Z24 and Allen-Bradley 700-HX

Page 81

General Purpose Relays

Specifications - 700-HHF Relays Attribute

700-HHF… 85…110% of Nominal Voltage at 50 Hz

Permissible Coil Voltage Variation

85…110% of Nominal Voltage at 60 Hz 80…110% of Nominal Voltage at DC SPST-NO-DM 50 Hz

Coil Consumption ±10%

AC Coils

DPDT 60 Hz

3PDT

50 Hz

60 Hz

50 Hz

60 Hz

Inrush

7.2 VA

6.3 VA

7.2 VA

6.3 VA

7.2 VA

6.3 VA

Sealed

4.8 VA

4.2 VA

4.8 VA

4.2 VA

4.8 VA

4.2 VA

DC Coils

1.4 W 25% of VA

Max. Allowable Leakage

10% of W

Design Specification/Test Requirements Dielectric Withstand Voltage

Pole-to-Pole

2200V AC

Contact-to-Pole

2200V AC

Contact-to-Frame

1600V AC

Mechanical Mechanical Life Operations

5 x 106

Switching Frequency Operations

3600/Hr

Coil Voltages Operating Time at Nominal Voltage at 20 °C

See Overview/Product Selection Pickup

20 ms

Dropout

15 ms

Maximum Operating Rate

4 Ops/s.

Environmental –30…+50 °C

Operating

(–22…+122 °F)

Temperature

–30…+100 °C

Storage

(–22…+212 °F)

Altitude

2000 m (6560 ft)

Construction Insulating Material

Molded High Dielectric Material

Enclosure

Transparent Dust Cover

Contact Material

Silver Cadmium Oxide

Terminal Markings

In accordance with EN50 0005 (2)

Sockets Certifications cURus Recognized, File E3125,Guide NLDX2/NLDX8, CE Marked

Standards

UL 508, CSA 22.2 No.14, EN/IEC 60947-1, -5-1

(1) See NEMA Ratings and Test Values on page 5. (2) 700-HHF relay wiring and terminals are the quick connect / solder type 6.35 x 0.82 mm (0.250 x 0.032 in) termination.

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

81

Page 82

General Purpose Relays

Dimensions - 700-HHF Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.

35.7 (1-13/32)

3.97 (5/32)

63.5 (2-1/2)

38.9 (1-17/32)

73.8 (2-29/32) 700-HHF Relay

82

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 83

General Purpose Relays

700-HTA Alternating Relay • Alternating Relay • Rugged Pin Style Socket Mounting • 10 A, SPDT, DPDT, and Cross Wired • Excellent for Pump Panel Applications

700

– a

HTA

2

A12

7 b c d e

Catalog Number Explanation - 700-HTA Relays a Bulletin Number

-

700 b Relay Type c Model Type d Coil Voltage e Gold Plated Contacts Option

HTA - Tube Base Alternating Relay

1 - SPDT 2 - DPDT 3 -Cross-Wired

A12 - 12V AC 50/60 Hz A24 - 24V AC 50/60 Hz A1 - 120V AC 50/60 Hz A2 - 240V AC 50/60 Hz

Blank - Without switch 7 - With switch

Alternating Relays with Pin-Style Terminations 700-HTA

Alternating Relay

SPDT Form C Contact

SPDT

DPDT 2 Form C Contact

DPDT

Cross-Wired DPDT 2 Form C Contacts

Cross-Wired

Wiring Diagrams U.S./Canada

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

International

83

Page 84

General Purpose Relays

Accessories - 700-HTA Relays Photo

84

Description

Pkg. Qty. Cat. No.

Screw Terminal Tube Base Socket, Panel or DIN Rail Mounting; Guarded Terminal Construction. 8-Pin for use with 700-HTA1A or -HTA3A alternating relays. Order ten or multiples of ten.

10

700-HN100

Screw Terminal Tube Base Socket, Panel or DIN Rail Mounting; Open Style Construction. 8-Pin for use with 700-HTA1A or -HTA3A alternating relays. Order ten or multiples of ten. No retainer clip required.

10

700-HN125

Screw Terminal Tube Base Sockets, Panel or DIN Rail Mounting; Guarded Terminal Construction. 11pin for use with 700-HTA2A alternating relays. Order in multiples of 10.

10

700-HN101

Screw Terminal Tube Base Sockets, Panel or DIN Rail Mounting; Open Style Terminal Construction. 11-pin for use with 700-HTA2A alternating relays. Order in multiples of 10. No retainer clip required. 10

700-HN126

DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m

10

199-DR1

Retainer Clip for Cat. Nos. 700-HN100 and -HN101 Sockets with 700-HT Timing Relays, and 700-HTA Alternating Relays Secures relay in socket. Order must be for 10 clips or multiples of 10.

10

700-HN110

Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N40

Blank Identification Tags, contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N41

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 85

General Purpose Relays

Specifications - 700-HTA Relays Attribute

700-HTA Electrical Ratings

Pilot Duty Rating (1)

NEMA B300 AC 15

Rated Thermal Current (Ith)

10 A

Rated Insulation Voltage (Ui)

250V IEC, 300V UL/CSA Inductive

Contacts

Make

Break

120V AC

30 A

3A

1/3

240V AC

15 A

1.5 A

1/2

Resistive 30V DC

10 A

10 A, 85…110% of Nominal Voltage at 50 Hz 85…110% of Nominal Voltage at 60 Hz

Permissible Coil Voltage Variation

Power Consumption ±10%

HP

AC

24V AC

2 VA

120V AC

4 VA

240V AC

4 VA

Design Specification/Test Requirements

Dielectric Withstand Voltage

Pole-to-Pole, same circuit (VRMS)

1000V AC

Pole-to-Pole, different circuits (VRMS)

2000V AC

Contact-to-Coil (VRMS)

2000V AC

Electrical Life Operations

100,000 minimum

Switching Frequency Operations

1800/hr

Coil Voltages

See product selection Mechanical

Degree of Protection

Open Type (Guarded Terminal Sockets)

Mechanical Life Operations

10 x 106

Switching Frequency Operations

18,000/hr

Start-up Time (max. time from power application until unit is timing)

0.05 sec

Max. Function Time (max. time power can drop out and unit continues timing)

0.01 sec

Min. Cycle Time

100 ms on release of the control switch

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

85

Page 86

General Purpose Relays

Specifications - 700-HTA Relays Attribute

700-HTA Environmental

Operating

–28…+65 °C (50 °C max., 240V AC coil) (–18…+149 °F) (122 °F max., 240V AC coil)

Storage

–55…+85 °C (–67…+185 °F)

Temperature

Altitude

2000 m (6560 ft) Construction

Insulating Material

Molded High Dielectric Material

Enclosure

Impact Resistant Dust Cover

Contact Material

Silver Tin Oxide

Terminal Markings on Socket Sockets

In accordance with EN50 005 8- or 11-Pin Socket 700-HN100, -HN125 700-HN101, -HN126

Certifications

CSA Certified, File 223833, UL Recognized (File E3125 Guide NLDX2/NLDX8), cULus Listed with 700-HN100, 700-HN101, 700-HN125, and 700-HN126 Sockets (File No. E3125 Guide NLDX/NLDX7), CE-Marked (per EU Low Voltage Directive)

Standards

EN 61812-1, CSA 22.2 No. 14, UL 508

(1) See NEMA Ratings and Test Values on page 5

86

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 87

General Purpose Relays

Trigger Signal Cat. Nos. 700-HTA Contact closure provides signal to timer. The 700-HTA alternating relay generates a low energy signal. For optimum reliability, use contacts designed for low energy switching (10V, 1 mA) (Example: Bul. 800F-X_V, 800T-X_V). No external voltage can be connected to the contact signal.

Load Diagrams - 700-HTA Relays Cross Wired Lead/Lag/Lag/lead Sequence

Common Input/Output SPDT/DPDT Lead

B1 Load A

Lag

Load B

Load A

LED A

Load B

LED B

LED A LED B

Power

Power Socket Pinout Map SPDT Relay Socket 4 A1 3 A2

Socket Pinout Map DPDT Relay Socket 4 A1 8 A2

Note: pin out in wiring diagram may not match actual printed socket see pinout map for wiring up the power source

Socket Pinout Map Cross-Wired Relay Socket 3 A1 6 A2

Note: pin out in wiring diagram may not match actual printed socket see pinout map for wiring up the power source

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

87

Page 88

General Purpose Relays

Dimensions - 700-HTA Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.

79 (3-7/64)

74 (2-29/32)

60 (2-23/64) 43 (1-11/16)

24.6 (31/32)

40.1 (1-37/64)

20.8 (53/64)

30.0 (1-3/16) 26 (1-1/32)

24.9 (63/64)

65.0 (2-35/64)

54.9 (2-5/32) 51.1 (2-1/64)

4.2 (5/32) 38.0 (1-1/2) #4–40 M3

Cat. No. 700-HN100 Panel Mounting Double Wire, 2 x 2.5 mm2 (#2 – 14 AWG…#2 – 20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in) – Torque: 0.8 N•m (7 lb•in)

33.0 (1-19/64)

14.7 (37/64)

Cat. No. 700-HN125 Wire Size: 2 x 2.5 mm2 Single Wire, Up to #12 AWG Double Wire, 2 x 2.5 mm2 (#2 – 14 AWG… #2 – 20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in), Torque: 0.8 N•m (7 lb•in)

59.2 (2-1/3) 30 (1-3/16)

26 (1-1/32)

7.9 (0.31)

24.6 (31/32) 20.8 (53/64) 26.9 (1.06) 54.9 (2-5/32)

65.0 (2-35/64)

4.2 (5/32)

51.1 (2-1/64)

38.0 (1-1/2) #4-40 M3

Cat. No. 700-HN101 Panel Mounting Double Wire – 2 x 2.5 mm2 (#2 – 14 AWG…#2 – 20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in) – Torque: 0.8 N•m (7 lb•in)

88

52.3 (2.06)

Cat. No. 700-HN126 Wire Size: 2 x 2.5 mm2 Single Wire, Up to 12 AWG Double Wire, 2 x 2.5 mm2 (#2 – 14 AWG…#2 – 20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in), Torque: 0.8 N•m (7 lb•in)

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

Page 89

General Purpose Relays

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

89

Page 90

General Purpose Electronic Timers and Counters

General Purpose Electronic Timers and Counters Product Overview

Bulletin No.

700-FE

700-FS

700-HR52, -HRP, -HRS, -HRT, -HRV

700-HRM/-HRC

700-HRF

Type

DIN Rail Timer

DIN Rail Timer

Multifunction Timer

On-Delay Timer

Twin Timer

Features

• Only 17.5 mm wide • 5 A contact rating • Multifunction or single function • No additional socket required

• Only 22.5 mm wide • 8 A contact rating • Multifunction or single function • No additional socket required • Optional: • Star-delta timing function • True off-delay timing function • Hazardous location certification

• Dial timing relays • 5 A contact rating • Multiple programmable timing ranges • Tube base pin style terminals • Multi-voltage inputs • Timed contacts and instantaneous contacts • Transistor outputs • Single function and multifunction • 7 different operating modes

• Dial timing relays • 5 A contact rating • Multiple programmable timing ranges • Tube base pin-style terminals • Multi-voltage inputs • Timed contacts and instantaneous contacts • Transistor outputs • Single function and multifunction

• Independent ON and OFF settings • 14 time ranges • 8-pin models available • Dial timing relays • UL508

Control Outputs: Time Limit Instantaneous

1 N.O. or SPDT timed

SPDT or DPDT or 2 N.O. + 1 common

DPDT Timed, Transistor SPDT Timed/Instantaneous

DPDT Timed, Transistor SPDT Timed/Instantaneous

DPDT Timed

On-delay Off-delay One shot Operation Modes: Repeat cyclepulse Fleeting off-delay Pulse converter

11 timing modes

On-Delay Off-Delay One Shot Repeat Cycle Off Start Repeat Cycle On Start Signal On/Off-Delay On-Delay One Shot

On-Delay

Repeat Cycle Off Start Repeat Cycle On Start

Time Range

0.05 s…10 hr

0.05 s…60 hr

0.05 s…300 h

0.05 s…300 h

0.05 s…300 h

Supply Voltage

24V AC/DC 110…240V AC 24…48V AC/DC 24…240V AC

12V DC 24V…48V DC 24V…240V AC

12…48V DC 24…48V AC 100…240V AC 100…125V DC

12…48V DC 24…48V AC 100…240V AC 100…125V DC

12V DC 24V AC/DC 48…125V DC 100…240V AC

Contact Rating at 120V AC

5A

8A

5A

5A

5A

Certifications

CE, cULus

CE, cULus cURus, CE, C-Tick cURus, CE, C-Tick cURus, CE, C-Tick

Socket Cat. No(s).

DIN Rail or panel mount

DIN Rail or panel mount

700-HN100 OR 700-HN101 700-HN125 OR 700-HN126

700-HN100 700-HN125

700-HN100 700-HN125

Page

92

96

116

117

117

Rockwell Automation Publication 700-TD552B-EN-P - August 2018

89