The text of a spec sheet · part 3 of 25
Relay and Timer Specifications, Bulletin Number 700, pages 21 to 30
Pages 21 to 30 of 250
The original document is the PDF (23 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 700-HA33Z24, Allen-Bradley 700-HN153, Allen-Bradley 700-HA32Z24 and Allen-Bradley 700-HX
Page 21
General Purpose Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 33.5 (1.32)
33.5 (1.32) 26.9 (1.06)
26.9 (1.06)
11.0 (0.43)
11.0 (0.43)
77.5 (3.05)
3.2 (0.13)
20.4 (0.80)
20.4 (0.80)
49.7 (1.96)
35.5 (1.40)
77.5 (3.05)
3.2 (0.13)
21.6 (0.85)
16.8 (0.66) 38.0 (1.50)
4.0 (0.16)
49.7 (1.96)
16.8 (0.66) 38.0 (1.50)
Cat. No. 700-HN204
35.5 (1.40)
21.6 (0.85)
4.0 (0.16)
Cat. No. 700-HN205
Wire Size: 2 x 2.5 mm2
Wire Size: 2 x 2.5 mm2
Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (14 AWG… 20 AWG) Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (14 AWG …20 AWG) Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
38.0 (1.50)
54 (2.13)
6.3 (0.25)
10.5 (0.41)
Cat. No. 700-HT3
Wire Size: 2 x 1.5 mm2 (#2 – 16 AWG…#1–20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
21
Page 22
General Purpose Relays
700-HB Square Base Relay • 15 A contact rating • DPDT, 3PDT • Blade-style quick connect /solder terminals • Standard ON/OFF flag indicator • Options: LED, push-to-rest, and manual override • Faston 187 (4.8 x 0.5 mm) Photo
Description
DPDT 2-Pole 2 Form C Single AgCdO Contact
Contact Rating
Wiring Diagrams U.S./Canada
International
15 A B300
Sockets
3PDT 3-Pole 3 Form C Single AgCdO Contact
700-HN154
700-HN153
15 A B300 Input
Sockets
700-HN154
700-HN153
(1) LED Option: Add suffix (-4) to the selected 700-HB Relay Cat. No., except for the 240V AC Units, add (-4L). Push-to-test, Manual Override, and LED Option: Add suffix (-3-4) to the selected 700-HB Relay Cat. No., except for the 240V AC units, add (-3-4L) Push-to-test and Manual Override option: Add suffix (-3) to the selected 700-HB relay.
22
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
Cat. No.(1)
6V AC
700-HB32A06
12V AC
700-HB32A12
24V AC
700-HB32A24
32
120V AC
700-HB32A1
34
240V AC
700-HB32A2
6V DC
700-HB32Z06
12V DC
700-HB32Z12
24V DC
700-HB32Z24
48V DC
700-HB32Z48
110V DC
700-HB32Z1
6V AC
700-HB33A06
12V AC
700-HB33A12
24V AC
700-HB33A24
120V AC
700-HB33A1
240V AC
700-HB33A2
6V DC
700-HB33Z06
12V DC
700-HB33Z12
24V DC
700-HB33Z24
48V DC
700-HB33Z48
110V DC
700-HB33Z1
31
Input
Coil Voltage
Page 23
General Purpose Relays
Accessories - 700-HB Relays Photo
Description
Pkg. Qty. Cat. No.
Diode Surge Suppressor Voltage Range: 6…220V DC used with 700-HN204 and 700-HN205 socket
10
700-ADR
Diode with LED Surge Suppressor Voltage Range: 6…24V DC used with 700-HN204 and 700-HN205 socket 10
700-ADL1R
Diode with LED Surge Suppressor Voltage Range: 28…60V DC used with 700-HN204 and 700-HN205 socket
10
700-ADL2R
Diode with LED Surge Suppressor Voltage Range: 110…220V DC used with 700-HN204 and 700-HN205 socket
10
700-ADL3R
Varistor with LED Surge Suppressor Voltage Range: 6…24V AC used with 700-HN204 and 700-HN205 socket
10
700-AV1R
Varistor with LED Surge Suppressor Voltage Range: 110…240V AC used with 700-HN204 and 700-HN205 socket
10
700-AV3R
RC Surge Suppressor Voltage Range: 6…24V AC/DC used with 700-HN204 and 700-HN205 socket
10
700-AR1
RC Surge Suppressor Voltage Range: 110…240V AC/DC used with 700-HN204 and 700-HN205 socket
10
700-AR2
Timing Module On-Delay or One-Shot selectable voltage range: 12…24V AC/DC used with sockets that accept plug-in accessory modules.
1
700-AT3
1
700-AT3A1
1
700-AT3A2
1
700-HT3
Timing Module On-Delay or One-Shot selectable voltage range: 110…125V AC used with sockets that accept plug-in accessory modules.
On-Delay U (A1/A2) LED & R t
One-Shot U (A1/A2) LED & R t
Timing Module On-Delay or One-Shot selectable voltage range: 230…240V AC used with sockets that accept plug-in accessory modules. 1. 1 s
0.05 s…1 s
2. 10 s
0.5 s…10 s
3. 100 s
5 s…100 s
4. 10 min
0.5 min…10 min
5. 100 min
5 min…100 min
6. 10 hours
0.5 h…10 h
7. 100 hours
5 h…100 h
8. LED Indicator
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
23
Page 24
General Purpose Relays Photo
Description
Cat. No.
Screw Terminal Socket, Panel or DIN Rail Mounting. Guarded Terminal Construction 11-blade socket for use with 700-HB relays. This socket has coil and contact separation as well as the ability to use optional plug-in modules (700-A__ accessories, LED, surge suppression, timing modules).
10
700-HN153
Screw Terminal Base Socket, Panel or DIN Rail Mounting. Open Style Construction 11-blade for use with 700-HB relays.
10
700-HN154
DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m
10
199-DR1
Retainer Clip For Cat. Nos. 700-HN154 Sockets with 700-HB Relays Secures relay in socket. Order must be for 10 clips or multiples of 10.
10
700-HN156
Retainer Clip For Cat. Nos. 700-HN153 Sockets with 700-HB Relays Secures relay in socket. Order must be for 10 clips or multiples of 10.
10
700-HN158
Relay Identification Snap-in Markers Snap-in markers fit on top of product covers. The following are blank cards. Squares slip into molded slot on top of product covers.
100
1492-MS5X12 1492-MS6X9 1492-MS6X12 1492-MS8X9 1492-MS8X12 1492-MP-Blank
Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
10
700-N40
Blank Identification Tags, contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
10
700-N41
Socket and Retainer Clip Reference Relay Type
Socket Cat. No.
Retainer Clip Cat. No.
700-HB
700-HN153 700-HN154
700-HN158 700-HN156
24
Pkg. Qty.
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
Page 25
General Purpose Relays
Specifications - 700-HB Relays Attribute
700-HB Electrical Ratings
Pilot Duty Rating (1) Rated Thermal Current (Ith)
NEMA B300 15 A – 120V, 240V 250V IEC-300V UL/CSA
Rated Insulation Voltage (Ui) Make
Break
Hp
Inductive Contacts
120V AC 240V AC General-purpose Resistive Min. Low Energy Permissible Load
2 -Pole 60 A 30 A
3 -Pole 30 A 15 A
Permissible Coil Voltage Variation
Coil Consumption ±10%
AC Coils Inrush Sealed DC Coils
2 -Pole 3 -Pole 6A 3A 3A 1.5 A 15 A, 240V AC 15 A, 30V DC 1000 mW (10V, 10 mA) 80…110% of Nominal Voltage at 50 Hz 80…110% of Nominal Voltage at 60 Hz 80…110% of Nominal Voltage at DC
50 Hz
60 Hz
3.3VA 2.2VA
2.85VA 1.9VA
3/4 2
1.3 W 25% of VA 10% of W 50 MΩ
Max. Allowable Leakage Max. Contact Resistance Design Specification/Test Requirements
Dielectric Withstand Voltage Pole-to-Pole Contact to Coil
2500V 4000V Mechanical
Degree of Protection (Open Type) IEC 529 Mechanical lifecycles (AC/DC) Switching Frequency Operations Coil Voltages Pickup Operating Time (ms) Dropout Maximum Operating Rate Endurance Vibration Operational Endurance Shock Operational
IP 40 > 10 x 106/30 x 106 3600/HR See Overview/Product Selection 20 ms 4 ms 4 Ops/s 5G 1.5 G 50 G 15 G Environmental
Temperature
Operating Storage
AC/DC AC/DC
–40…+70 °C –40…+100 °C
Altitude
2000 m (6560 ft) Construction
Insulating Material Enclosure Contact Material Terminal Markings on Socket Sockets Certifications Standards
Molded High Dielectric Material Transparent Dust Cover AgCdO In accordance with EN50 0005 700-HN153, -HN154 cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN sockets noted UL508, CSA C22.2 No. 14, EN 61810-1
(1) See NEMA Ratings and Test Values on page 5
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
25
Page 26
General Purpose Relays
Cycles
Technical Data - 700-HB Relays
Load (kVA)
Maximum Switching Current (A)
Contact life versus AC1 load at 600 cycles/h.
Voltage DC (V)
Reduction Factor
Breaking capacity for DC1 load at 600 cycles/h. Load applied to one contact. A = for N.O. types B= other types
(Highly Resistive)
COS φ
(Inductive)
Load Reduction factor versus cos φ
26
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
Page 27
General Purpose Relays
Dimensions - 700-HB Relays Approximate Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 60.9 (2.40)
35.8 (1.41)
30.25 (1.19)
38.2 (1.50)
27.0 (1.06)
40 (1.57)
34.3 (1.35) Ø 3.2 (0.13)
91.3 (3.59)
51.4 (2.02)
35.4 (1.39)
95.3 (3.75) 46.3 (1.82)
21.6 (0.85)
32.0 (1.26)
35.5 (1.40)
700-HB Relay
Cat. No. 700-HN153 2
Wire Size: 2 x 2.5 mm Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (14 AWG… 20 AWG), Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
49.5 (1.95)
25.6 (1.01)
35.4 (1.40)
38.0 (1.50)
84.85 (3.34) 54 (2.13)
84.3 (3.32)
41.5 (1.63)
6.3 (0.25)
4.0 (0.16)
Cat. No. 700-HN154
10.5 (0.41)
Cat. No. 700-HT3
Wire Size: 2 x 2.5 mm2
Wire Size: 2 x 1.5 mm2 (#2 – 16 AWG…#1–20 AWG)
Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (14 AWG… 20 AWG), Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
(Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
27
Page 28
General Purpose Relays
700-HD Flange Mount Square Base Relay • Flange-mounted/panel-mounted • 15 A contact rating • DPDT, 3PDT • Blade-style quick connect terminals (0.187 x 0.020) • Solder terminals (no socket required)
Photo
Wiring Diagrams U.S./Canada
Contact Rating
DPDT 2-Pole 2 Form C AgCdO Contacts
International
32
15 A
34 31
Input
3PDT 3-Pole 3 Form C AgCdO Contacts
15 A
Input
Coil Voltage
Cat. No.
6V AC 12V AC 24V AC 120V AC 208V AC 240V AC 6V DC 12V DC 24V DC 48V DC 110V DC 6V AC 12V AC 24V AC 120V AC 208V AC 240V AC 6V DC 12V DC 24V DC 48V DC 110V DC
700-HD32A06 700-HD32A12 700-HD32A24 700-HD32A1 700-HD32A20 700-HD32A2 700-HD32Z06 700-HD32Z12 700-HD32Z24 700-HD32Z48 700-HD32Z1 700-HD33A06 700-HD33A12 700-HD33A24 700-HD33A1 700-HD33A20 700-HD33A2 700-HD33Z06 700-HD33Z12 700-HD33Z24 700-HD33Z48 700-HD33Z1
Accessories - 700-HD Relays Photo
28
Pkg. Cat. No. Qty.
Description
Relay Identification Snap-in Markers Snap-in markers fit on top of product covers. The following are blank cards. Squares slip into molded slot on top of product covers.
100
1492-MS5X12 1492-MS6X9 1492-MS6X12 1492-MS8X9 1492-MS8X12 1492-MP-Blank
Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
10
700-N40
Blank Identification Tags, contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
10
700-N41
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
Page 29
General Purpose Relays
Specifications - 700-HD Relays Attribute
700-HD Electrical Ratings
Pilot Duty Rating
(1)
NEMA B300
Rated Thermal Current (Ith)
15 A(2) – 120V 15 A (2) – 240V,
Rated Insulation Voltage (Ui)
250V IEC-300V UL/CSA
Inductive
Contacts
Make
Hp
Break 2-Pole
3-Pole
2-Pole
3-Pole
120V AC
60 A
30 A
6A
3A
3/4
240V AC
30 A
15 A
3A
1.5 A
2
General-purpose
15 A, 240V AC
Resistive
15 A, 30V DC
Min. Low Energy Permissible Load
1000 mW (10V, 10 mA)
Permissible Coil Voltage Variation
80…110% of Nominal Voltage at 50 Hz 80…110% of Nominal Voltage at 60 Hz 80…110% of Nominal Voltage at DC
Coil Consumption ±10%
AC Coils
50 Hz
60 Hz
Inrush
3.3VA
2.85VA
Sealed
2.2VA
1.9VA
DC Coils
1.3 W
Maximum Contact Resistance
50 MΩ 20% of Nominal V AC 10% of Nominal V DC
Must Dropout Voltage
Design Specification/Test Requirements Electrical Dielectric Withstand Voltage
Pole-to-Pole
2500V
Contact to Coil
4000V Mechanical
Degree of Protection (Open Type) IEC 529
IP 40
Mechanical lifecycles (AC/DC)
See Overview/Product Selection
Switching Frequency Operations
3600/HR > 10 x 106 / 30 x 106
Coil Voltages Operating Time
Pickup
20 ms
Dropout
4 ms
Maximum Operating Rate
4 Ops/s
Minimum Low Energy Permissible Load
1000 mN (10V, 10 mA) Environmental
Temperature Altitude
Operating
–40…+70 °C
Storage
–40…+100 °C 2000 m (6560 ft)
Rockwell Automation Publication 700-TD552B-EN-P - August 2018
29
Page 30
General Purpose Relays
Attribute
700-HD Construction
Insulating Material
Molded High Dielectric Material
Enclosure
Transparent Dust Cover
Contact Material
Silver Cad. Ox.
Terminal Markings
In accordance with EN50 0005
Certifications cURs Recognized (File No. E3125, Guide NLDX2/NLDX8), CSA Certified (File No. 229473), CE Marked, UR Certified
Standards
UL 508, CSA C22.2 No. 14, EN 61810-1
Cycles
Maximum Switching Current (A)
(1) See NEMA Ratings and Test Values on page 5 (2) 3-pole relays have a 20 A maximum total current rating for all three poles.
Voltage DC (V)
Load (kVA)
Contact life versus AC1 load at 600 cycles/h.
Breaking capacity for DC1 load at 600 cycles/h.
Reduction Factor
Load applied to one contact. A = for N.O. types B = other types
(Highly Resistive)
COS φ
(Inductive)
Load Reduction factor versus cos φ
30
Rockwell Automation Publication 700-TD552B-EN-P - August 2018