Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Bulletin 700-P, -PK, -PH Industrial Relays

Spec sheet · Allen-Bradley

Bulletin 700-P, -PK, -PH Industrial Relays

Spec sheet15 pagesPDF 1.0 MB

Catalog section for Allen-Bradley Bulletin 700-P, -PK and -PH industrial relays: selection, timers, safety relays, accessories and specs.

Download the PDF1.0 MB

Names · 1 model

The models it names

Filed with · 5 models

Also filed with these models on the old site

Summary

What is in it

Allen-Bradley catalog pages for the Bulletin 700-P, 700-PK and 700-PH industrial relays, convertible contact cartridge relays with NEMA and IEC ratings. They cover product selection for electrically held, time delay and 700S-P safety control relays, accessories such as adder decks, latches, surge suppressors, jumper kits and mounting strips, specifications, operating coils and approximate dimensions. Many selection tables and drawings are poorly extracted in this file.

Its parts

  1. Product Selection
  2. Electrically Held Relays
  3. Time Delay Relays
  4. Safety Control Relays
  5. Accessories
  6. Specifications
  7. Operating Coils
  8. Approximate Dimensions

From the sheet · read page by page

Key facts from this sheet

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

An Allen-Bradley catalog section on Bulletin 700-P, 700-PK and 700-PH industrial relays: selection tables for AC and DC relays, time delay and latching versions, 700S-P safety control relays, accessories, specifications, replacement coils and dimensions. It lists the 700-P200, 700-P400, 700-P800 and 700-PK800 relays with their coil voltage suffix codes, and the 700-PB40 adder deck. It does not name the 700-BR600A1.

Document
Catalog pages for Bulletin 700-P, -PK and -PH industrial relays: product selection, accessories, specifications, operating coils, dimensions p. 1
700-P contacts
700-P: standard 10 A contact cartridges, double-break and bifurcated p. 1
700-PK contacts
700-PK: 20 A master contact cartridges p. 1
Contacts per relay
700-P and 700-PK: up to 12 contacts, at most 8 N.C. p. 1
Convertible contacts
N.O. contacts can be changed to N.C. in the field p. 2
700-PB40
700-PB40: 4-pole second deck (adder deck) p. 9
Coil code A1
AC suffix A1: optimized for 115…120V, 60 Hz; operates at 110V, 50 Hz p. 2
Coil voltage range
AC 85…110%, DC 80…110% p. 13
Operating temperature
–20…+65°C (–4…149°F), inside the panel p. 13
Operating time
Pickup AC 10…20 ms, DC 30…50 ms; dropout AC 10…20 ms, DC 20…33 ms p. 13
Mechanical life
10 million operations p. 13
Shipping weight
2- and 4-pole 700-P or -PK: AC 0.68 kg (1.5 lbs.), DC 1.34 kg (2.95 lbs.) p. 15
Logic reed cartridge
700-CPR for low energy circuits: 150V AC 500 mA 25 VA max; 30V DC 200 mA 6 W max p. 9
Surge suppressors
700-N5 and 700-N24 RC surge suppressors, max 150V AC or DC, 35 VA p. 12

What this sheet walks you through

  • Choosing an AC or DC relay and its coil voltage suffix p. 2, 3, 5
  • Ordering time delay relays with pneumatic timers p. 6
  • Ordering mechanical latching relays p. 7
  • Selecting 700S-P safety control relays with 700-CPS cartridges p. 8
  • Adding adder decks and convertible contact cartridges p. 9
  • Choosing solid-state timers and remote potentiometers p. 10
  • Choosing latch units, mounting strips and enclosures p. 11
  • Fitting surge suppressors and 35 A jumper kits p. 12
  • Finding replacement operating coils p. 14
  • Mounting dimensions and mounting strip screws p. 15

Good to know

  • An open or failed unlatch circuit leaves the relay latched, so a latch unit should not be used where protection against automatic restart after a power failure is needed. p. 7
  • Coils for AC relays cannot be used in DC relays, and the other way around. p. 14
  • 700-CPS cartridges must not be used in timers and latches. p. 8
  • Solid-state timer ranges are approximate: the maximum time may be 50% greater and the minimum 50% less. p. 10
  • The dimensions are not meant for manufacturing use. p. 15

Questions this sheet answers

What is the Allen-Bradley 700-PB40?

It is listed among the adder deck accessories as a 4-pole second deck. p. 9

What does the A1 coil suffix mean on a 700-P relay?

A1 is an AC coil code optimized for 115…120V, 60 Hz; it also operates satisfactorily at 110V, 50 Hz. p. 2

Can 700-P contacts be changed from normally open to normally closed?

Yes. The sheet says the normally open contacts can be changed to normally closed in the field. p. 2

What is the operating temperature of a 700-P relay?

–20…+65°C (–4…149°F), measured inside the panel. p. 13

Which tool holds a 700-P relay in the operated position for troubleshooting?

The check out tool, 700-N23. p. 12

The whole text · 2 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. Pages 9 to 159-15

The file

Size and text

PublisherAllen-Bradley
Pages15
PDF1.0 MB
TextText from the PDF itself; pages 1, 8 and 12 are scans, read by OCR, which may hold reading errors.

The first pages · 4 of 15

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 15
Page 2
Page 2of 15
Page 3
Page 3of 15
Page 4
Page 4of 15