For the Allen-Bradley 700-PB40

Page 9

Bulletin 700-P, -PK, -PH

Industrial Relays

Accessories, Continued Adder Decks Contacts Description

N.O.

N.C.

Continuous Carrying Current (A)

2, 10

2, 20

Arrangement

Cat. No. ➋

B1X

700-PB20

B4X

Second Deck (2-pole) 700-PKB20

B1Y

Second Deck Cat. No. 700-PB40

4, 10

4, 20

2, 10

2, 20

B4Y

B1X

B2X

B3X

B4X

B1Y

B2Y

B3Y

B4Y

700-PB40

Second Deck (4-pole)

C1X

700-PKB40 700-PC20

C4X

Third Deck (2-pole)

Third Deck Cat. No. 700-PC40

4, 10

4, 20

700-PKC20

C1Y

C4Y

C1X

C2X

C3X

C4X

C1Y

C2Y

C3Y

C4Y

700-PC40

Third Deck (4-pole) 700-PKC40

Contact Cartridges (Convertible from N.O. to N.C. and N.C. to N.O.) Description

Standard Contact Cartridge Cat. No. 700-CP1, -CP11Z

Standard Contact Cartridge AC Rating NEMA A600 DC Rating NEMA P600 Overlap Contact Cartridges ➊ Overlapping Used in pairs. N.O. contact closes before N.C. contact opens on pick-up and vice versa on drop-out.

Master Contact Cartridge Cat. No. 700-CPM

DC Rating NEMA P150 125V DC, 138 VA Make and Break

Master Contact Cartridge AC Rating Twice NEMA A600 DC Rating Twice NEMA P600

Logic Reed Cartridge for Low Energy Circuits ➊ 150V AC 500 mA 25 VA Max. 30V DC 200 mA 6 W Max. Logic Reed Cartridge Cat. No. 700-CPR

➊ Not Direct Drive. ➋ All Cat. Nos. are factory stocked.

236

AC Rating NEMA A600

Continuous Carrying Current (A)

Arrangement

Pkg. Qty.

Cat. No. ➋

10

OR

1

700-CP1

OR

2

700-CP11Z

OR

1

700-CPM

OR

1

700-CPR

10

5

20

Maximum 150V AC

Maximum 30V DC

500 mA

200 mA

Page 10

Bulletin 700-P, -PK, -PH

Industrial Relays

Accessories, Continued Pneumatic Time-Delay Unit – 1 N.O. and 1 N.C. Convertible Contact Cartridge ➊ Description Mode

Continuous Carrying Current (A)

Contacts N.O.

Arrangement

Cat. No. ➌

N.C.

D1X

10

Pneumatic Time-Delay

On-Delay/ Off-Delay

1

Timing Range

Open Type Without Enclosure

D2X

1

700-PT 0.1…60 s. 700-PKT

20

D1Y

D2Y

Bulletin 700-PS and -PSR Solid-State Timers Description

Continuous Carrying Current (A)

Timing Range ➋

Cat. No. ➌

0.1…2 s

700-PSAA1

0.4…8 s

700-PSBA1

1.5…30 s

700-PSCA1

S2

6…120 s

700-PSDA1

ADJ. POT.

0.1…2 s

700-PSPA1

0.4…8 s

700-PSRA1

1.5…30 s

700-PSTA1

6…120 s

700-PSUA1

0.1…2 s

700-PSRAA1

0.4…8 s

700-PSRBA1

1.5…30 s

700-PSRCA1

6…120 s

700-PSRDA1

0.1…2 s

700-PSRPA1

0.4…8 s

700-PSRRA1

1.5…30 s

700-PSRTA1

6…120 s

700-PSRUA1

Arrangement

External Initiating Contact

Self-Contained Potentiometer On-Delay

C1

S1

5 Output Contact (C1, C2)

C2

Off-Delay

L1

L2

110/120V, 50/60 Hz Power

External Potentiometer

C1 Output Contact (C1, C2)

On-Delay 5

C2

S1

S2

R1

R2

L1

L2

Off-Delay

Remote Pot. Max. Shielded Cable Length 50 FT UL Style #2517 or Equivalent ➊ Mounts on 4-pole Bulletin 700-P or -PK relay or 2-pole Bulletin 700-PH relay. ➋ Maximum time may be 50% greater and the minimum time may be 50% less than the value specified. ➌ All Cat. Nos. are factory stocked.

Remote Potentiometers for Cat. No. 700-PSR… Timing Range (s) 0.1…2 0.4…8 1.5…30 6…120

Resistance (MΩ) 0.75 0.75 2.0 3.5

Cat. No. 700-N35 700-N35 700-N36 700-N37

237

Page 11

Bulletin 700-P, -PK, -PH

Industrial Relays

Accessories, Continued Mechanical Latch Units Description

Arrangement D1X

D2X

Continuous Carrying Current (A)

Open Type Without Enclosure

Without

700-PLL⊗

10

700-PLL11⊗

20

700-PKLL11⊗

Without

700DC-PLL⊗

10

700DC-PLL10⊗

20

700DC-PKLL10⊗

K3

AC-Operated Latch Units D1Y

D2Y

K4

Reset Input D1X

D2X

K3

DC-Operated Latch Units

D1Y

Cat. No. ➊

D2Y

K4

⊗ AC Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-PLL⊗ becomes Cat. No. 700-PLLA1. For other coil voltages, consult your local Allen-Bradley Sales Office.

Hz

24

127 200-208 220-230 230-240 277 347 380

415 440-480 460-480 500 575-600

50

B24 B48 A1*

48

110 110-115 115-120 120 B11†, - B27, B22

B2, - B3

B41

B44, B50, 60

A24 A48, A1*

B11†, A20

A22

A2

A27 A35, - - A4, A6, * Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. † Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.

⊗ DC Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PLL⊗ becomes Cat. No. 700DC-PLLZ12. For DC Coils, see page 232. For other coil voltages, consult your local Allen-Bradley Sales Office. 6

12

18

24

32

48

64

72

90

115-125

230-250

500-550

575-600

Z06

Z12

Z18

Z24

Z32

Z48

Z64

Z72

Z90

Z1

Z2

Z5

Z6

Relays Per Strip

Pkg Qty.

Cat. No. ➊

4

5

700-MP4

8

5

700-MP8

12

5

700-MP12

16

5

700-MP16

Type 1 Enclosure – Use for all Bulletin 700-P, -PH and -PK relays except 10- and 12-pole DC relays or 5- and 6-pole DC Bulletin 700-PH relays. Order electrically held relays (Bulletin 700-P, -PH, or -PK) in a NEMA Type 1 enclosure directly from the tables on pages 229…232. This enclosure is also suitable for Bulletin 700-RTC timing relays.

1

700-N31

Type 4/4X Enclosure – For 2- and 4-pole Bulletin 700-P, -PH, -N and -R relays and 2-pole Bulletin 700-PH relays.

1

700-N39

Type 7 & 9 Enclosure – For 2- and 4-pole Bulletin 700-P, -PK, -N and -R relays and 2-pole Bulletin 700-PH relays. 1 conduit hub; top and bottom.

1

700-N33

Description

Mounting Strip Cat. No. 700-MP4

Cat. No. 700-N31

➊ All Cat. Nos. are factory stocked.

238

Universal Mounting Strips – Accepts Bulletin 700-P, -PH, -PK, -R, -RM, and -N control relays, as well as Bulletin 700-RTC timing relays. These strips are easily cut to the required length and bolted, riveted, or spot-welded in place. Relays are installed adjacent to one another on the mounting strip with the captive mounting screws provided. 5 strips/package.

Page 12 read from a scan by OCR; it may hold reading errors

Bulletin 700-P, -PK, -PH

Industrial Relays Accessories, Continued

Description ot Cat. No. ® Mounting behind 1 700-N5 Surge Suppressors (RC Circuit), Surge suppressors _ [relay reduce the high transient voltages generated when the coil Surge Suppressor circuit is opened. These suppressors can be used with a Bulletin 700-P, -PH, -PK and -N relays, and other electromechanical devices. They contain a resistor and capacitor. Maximum ratings: 150V, AC or DC, 35 VA. eS ; Cat. No. 700-N5 requires 1 in. additional depth of Mounting on 00 ame enclosure. : i 1 700-N24 coil terminal Surge Suppressor Cat. No. 700-N24 24...48V AC/DC 1 199-FSMAQ MOV Surge Suppressors 15 J Used on Bulletin 700-P, -PH, -PK, -N, -F, -R (DC Only) and | 50...120V AC/DC 1 499-FSMA10 -RM (DC Only) relays. Mounting on coil terminal. 15J 1J=1Vx1Ax18 130...250V AC/DC 4 199-FSMA11 Surge Suppressor Cat. No. 199-FSMA1 Diode Surge Suppressor, for 6...300V DC voltage coils. Used on Bulletin 700-P, 1 199-ESMZ-1 -PH, -PK, -N, -F, and -R relays. << 35 A Jumper Kit, CSA Approved, UL Listed e@ This 35 A Jumper Kit can be used with any Bulletin 700-P and -PK AC or DC relay, Time-Delay relay or Latch Unit equipped with 20 A Master Cartridges. It does not require any additional panel space. Vo Jumper Kit terminals are designed for one #8 AWG wire or two #10 AWG wires. 1 700-CPH When connecting the two 20 A Master Cartridges in parallel, it is important that 35A Jumper Kit they be the same configuration (Normally Open or Normally Closed). Cat. No. 700-CPH . . Jumpers can be added to any contact cartridge location on a relay except the two center poles because of the wide spacing. An adhesive label is included with each < a kit listing the contact ratings. Le = Jumpers (Not applicable for Bulletin 700-PH or Jumper, For outer ys 2 -PK relays), For connection between a middle pole and an 700-N3 : : poles Jumper Jumper outer pole on the left or right side of the relay. Ip Ip. 50 Cat. No. 700-N3__ - Cat. No. 700-N4 Jumpers (Not applicable for Bulletin 700-PH or Jumper, For middle 700-N4 -PK relays), For connection between two middle poles. | poles Check Out Tool, Mechanically holds the Bulletin 700-P, -PH or -PK relay in the 700-N23 operated position for troubleshooting purposes. 1 Adapter Plate, Simplified relay conversion. Allows you to use the existing Check Out Tool mounting holes when you replace a Bulletin 700-B, -BR, -BX or -D relay with a 700-N34 Cat. No. 700-N23 Bulletin 700-P, -PH, or -PK relay. Protective Cover - For 700-PT Timing Adjustment Knob. Helps prevent tampering “ab at : 5 700-N38 with time setting. @ All Cat. Nos. are factory stocked. Allen-Bradley 239

Page 13

Bulletin 700-P, -PK, -PH

Industrial Relays Specifications Type

700-P, PLL, PT

700-PK, PKLL, PKT

700-PH

Electrical 10 A @ 600V AC 5 A @ 600V DC

Contact Rating Continuous Ratings Make/Break

35 A @ 600V AC 20 A @ 600V DC

AC

NEMA A600

2 x NEMA A600

2 x NEMA A600

DC

NEMA P600

2 x NEMA P600

2 x NEMA P600

Additional Contact Ratings for AC single-phase loads

Cartridge Cat. No. 700-CP1

Contacts in Series DC Switching

5 Hp @ 240V AC - N.O. 3 Hp @ 240V AC - N.O./N.C. 2 Hp @ 120V AC - N.O./N.C. 35 A General Use At 0.75 PF to 600V AC 35 A Tungsten Lighting Load to 480V AC

3 Hp @ 240V AC - N.O. 2 Hp @ 240V AC - N.O./N.C. 1 Hp @ 120V AC - N.O./N.C. 20 A Resistive Heating to 600V AC 20 A Tungsten Lighting Load to 480V AC, DC Current Ratings Make/Break

Coil Voltage Range

20 A @ 600V AC 10 A @ 600V DC

Cartridge Cat. No. 700-CPM

Cartridge Cat. No. 700-CPH

Volts DC 24

64

125 250

500

600

24

64

125

250

500

600

24 480W

64 480W

125 275W

250 138W

500 135W

1

5 A 2.2 A 1.1 A .55 A .24 A .2 A

10 A

5A

2.2 A

.55 A

.24 A

.2 A

10 A

5A

2.2 A

.55 A

.24 A

.2 A

2

10 A 10 A

20 A

10 A

5A

2A

.7 A

.5 A

20 A

10 A

5A

2A

.7 A

.5 A

5A

2A

.7 A

.5 A

3, - 7A

3 A 1.5 A 1.0 A, 15 A

7A

3A

1.5 A

1.0 A, 15 A

7A

3A

1.5 A

1.0 A

4, - 10 A 5 A 2.5 A 1.5 A, 20 A

10 A

5A

2.5 A

1.5 A, 20 A

10 A

5A

2.5 A

1.5 A

AC

85…110%

85…110%

85…110%

DC

80…110%

80…110%

80…110%

Battery Charging

85…115%

85…115%

85…115%

A Inrush Coil Consumption C Sealed P-PH-PK D Inrush C Sealed

50 Hz

60 Hz

50 Hz

60 Hz

50 Hz

60 Hz

132 VA

138 VA

132 VA

132 VA

19 VA

19.3 VA

138 VA 19 VA

138 VA 19 VA

19.3 VA 12.7 VA

12.7 VA

12.7 VA

12.7 VA

19.3 VA 12.7 VA 12.7 VA

PLL - PKLL

Inrush

15 VA

15.6 VA

5 VA

15.6 VA

15 VA

AC Latch Unit

Sealed

5.4 VA

5.5 VA

5.4 VA

5.5 VA

5.4 VA

PLL - PKLL

Unlatch

35 VA

35 VA

35 VA

DL Latch Unit

Intermitten t

35 W

35 W, Reset Time

PT – PKT

75 ms

75 ms, Minimum Pulse

PLL–PKLL

75 ms

15.6 VA

75 ms, 5.5 VA

Mechanical Pickup

AC – 10…20 ms DC – 30…50 ms

AC – 10…20 ms DC – 30…50 ms

AC – 10…20 ms DC – 30…50 ms

Dropout

AC – 10…20 ms DC – 20…33 ms

AC – 10…20 ms DC – 20…33 ms

AC – 10…20 ms DC – 20…33 ms

Operating Time Mechanical Life

10 million operations

Construction Contact Arrangement

Up to 12 Poles, Convertible to N.O. or N.C. (8 N.C. Maximum)

Up to 12 Poles, Convertible to N.O. or N.C. (8 N.C. Maximum)

Up to 6 Poles, Convertible to N.O. or N.C. (4 N.C. Maximum)

Nickel Silver

Silver Cadmium Oxide

Silver Cadmium Oxide

Panel or Strip Mount Horizontal Mounting Recommended

Panel or Strip Mount Horizontal Mounting Recommended

Panel or Strip Mount Horizontal Mounting Recommended

Contact Material Mounting

Environmental Temperature

Operating ➊

–20…+65°C (–4…149°F)

–20…+65°C (–4…149°F)

–20…+65°C (–4…149°F)

Storage

–40…+65°C (–40…149°F)

–40…+65°C (–40…149°F)

–40…+65°C (–40…149°F)

➊ Temperature inside the panel.

240

600 120W

Page 14

Bulletin 700-P, -PK, -PH

Industrial Relays

Specifications, Continued Operating Coils Bulletin 700 Bulletin 700-P-PH-PK Relays, Bulletin 700-PLL-PKLL Mechanical Latch Attachments ➊ Coil Volts 24

Bulletin 700-P Operating Coil

Bulletin 700-PL Unlatch Coil and Magnet Assembly

Bulletin 700-P, -PK 2-…12-pole, Bulletin 700-PH 1-…6-pole AC

Bulletin 700-PLL–PKLL AC Mechanical Latch Attachment

Bulletin 700-P-PK 2-…12-pole, Bulletin 700-PH 1-…6-pole DC

60 Hz

50 Hz

60 Hz

50 Hz, PA013

PA407

PL013

PL407

PD714 PD718

32, - - - 48

PA222

PA314

PL222

PL314

PD724

110 ➋, PA236, PL236

PD733 ➍ (100…110)

115…120 ➋

PA236, PL236, - 110…115 ➌, PA322, PL322, 115…125, - - - PD735

120 ➌

PA322, PL322, - 130…140, - - - PD738

200…208

PA249, PL249, - 220…230

PA251

PA339, PL339, 230…240

PA254

PA342

PL254

PL342, 230…250, - PD748, PD748

277

PA260, - - - 380, PA354, PL354, 415, PA357, PL357, 440…460, PA360, PL360, 460…480

PA273, PL273, - 500, PA364, PL364

PD759

575…600

PA273, PL278, PD758

➊ Coils for AC relays cannot be used in DC relays and vice versa. ➋ This coil is optimized for 115…120V, 60 Hz applications and will operate satisfactorily at 110V, 50 Hz. ➌ This coil is optimized for 110…115V, 50 Hz applications and will operate satisfactorily at 120V, 60 Hz. ➍ This coil is designed and marked for use at 100…110V DC.

241

Page 15

Bulletin 700-P, -PK, -PH

Industrial Relays

Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Bulletin 700-P, -PH and -PK Relays AC – 97.63 (3-27/32) DC – 120.49 (4-3/4)

57.15 (2-1/4)

AC – 165.89 (6-17/32)

57.15 (2-1/4)

7.94 (5/16)

DC – 188.75 (7-7/16)

7.94 (5/16)

89.69 (3-17/32) 79.38 (3-1/8)

89.69 (3-17/32) 79.38 (3-1/8)

Provision for 2–#8/#10 Mfg. Screws Provision for 2–#8/#10 Mfg. Screws

2- and 4-pole Bulletin 700-P or -PK Relay, 2-pole Bulletin 700-PH Relay Approximate Shipping Weight AC – 0.68 kg (1.5 lbs.), DC – 1.34 kg (2.95 lbs.)

2- and 4-pole Bulletin 700-P or -PK Relay or 2-pole Bulletin 700-PH Relay with Pneumatic Time Delay Attachment Approximate Shipping Weight AC – 0.85 kg (1.88 lbs.), DC – 1.5 kg (3.33 lbs.)

AC – 130.97 (5-5/32) 57.15 (2-1/4)

DC – 153.83 (6-1/16)

AC – 165.89 (6-17/32) 7.94 (5/16)

57.15 (2-1/4)

DC – 188.75 (7-7/16)

7.94 (5/16)

89.63 (3-17/32)

89.63 (3-17/32) 79.38 (3-1/8)

79.38 (3-1/8)

Provision for 2–#8/#10 Mfg. Screws

Provision for 2–#8/#10 Mfg. Screws

2- and 4-pole Bulletin 700-P or -PK Relay or 2-pole Bulletin 700-PH Relay with Mechanical Latch Attachment Approximate Shipping Weight AC – 0.97 kg (2.13 lbs.), DC – 1.62 kg (3.58 lbs.)

6- and 8-pole Bulletin 700-P or -PK Relay, 4-pole Bulletin 700-PH Relay Approximate Shipping Weight AC – 0.79 kg (1.75 lbs.), DC – 1.45 kg (3.20 lbs.) AC – 164.31 (6-15/32) DC – 187.17 (7-3/8)

57.15 (2-1/4)

Cat. No. 700

7.94 (5/16)

34.93 (1-3/8)

89.69 (3-17/32) 79.38 (3-1/8)

{

-MP4 229 (9) -MP8 457 (18) -MP12 686 (27) -MP16 914 (36)

92.08 (3-5/8)

12.7 (1/2)

Provision for 2–#8/#10 Mfg. Screws

10- and 12-pole Bulletin 700-PPK Relay, 6-pole Bulletin 700-PH Relay Approximate Shipping Weight AC – 1.02 kg (2.25 lbs.), DC – 1.68 kg (3.7 lbs.) 109.54 (4-5/16)

123.83 (4-7/8)

28.58 (1-1/8)

57.15 (2-1/4)

57.15 (2-1/4)

#8 Screws (Captive)

Universal Mounting Strip for Bulletin 700-P, -PH, -PK, -N, -NM, -R, -RM, -RT, -RTA Relays Secure the mounting strip with 2 screws at each end relay position. Use a minimum of one screw at the 3rd, 5th, 7th, etc., relay positions. Alternate between upper and lower horizontal slots. AC – 164.7 (6-1/2) DC – 187 (7-25/64)

142.88 (5-5/8)

195.26 (7-11/16)

700-PS Timer

95.25 (3-3/4)

Type 1 Enclosure (Approximate Shipping Weight 1.04 kg (2.3 lb.) for Bulletin 700-P or -PK Relay (2…4-pole); Bulletin 700-PH Relay (1…2-pole only); Cat. No. 700-N31 NEMA Type 1 Enclosure for other Bulletin 700-P, -PH, -PK, -RTC Relays has same dimensions except the depth is 178 mm (7"). Approximate Shipping Weight 1.26 kg (2.8 lb.)

242

Bulletin 700-PS Timer Mounted on a 4-pole Bulletin 700 Bulletin 700-P or -PK Relay or 2-pole Bulletin 700-PH Relay. Approximate Shipping Weight AC – 0.68 kg (1.5 lbs.) without 700-PS, eDC – 1.34 kg (2.9 lbs.) without 700-PS