Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a spec sheet · part 1 of 2

Bulletin 700-P, -PK, -PH Industrial Relays, pages 1 to 8

Pages 1 to 8 of 15

The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 700-PB40

Page 1 read from a scan by OCR; it may hold reading errors

Bulletin 700-P, -PK, -PH Industrial Relays

Cat. No. 700-PH200 “=

Cat. No. 700-PK400A1

AQ = \S)

TABLE OF CONTENTS

Bulletin 700

Direct Drive™ Convertible Contact Cartridge Relays NEMA and IEC Ratings 600V Maximum AC/DC Contact Ratings:

¢ 10 A 700-CP1-and 700-CPS e 20 A 700-CPM

¢ 35 A 700-CPH e Low Power 700-CPR Easy Accessory Additions: e Adder Decks e Time Delay e Latching

¢« Surge Suppressors e Mounting Strip

For Machine Tool and Other Heavy Duty Applications

Can Accommodate Ring Tongue Terminals

Expands Safety Relay Outputs

Description Page | Description Page Product Selection Accessories ...... 0.0... 0.0.0 235 Electrically Held Relays ......... 0.00.00 0 cece eee eae 229 | Specifications .............. 0.000 ee 240 Time Delay Relays........... 0.0.0.0 cece eee eee eee 233 Operating Coils... 1.2.0.0... 000.00 c eee 241 Safety Control Relays ............ 0.0000: e eee eee eee 235 | Approximate Dimensions .......................-0020005 242 Description

The Bulletin 700-P family of relays has 4 types of contact cartridges to meet your specific switching requirements. Different cartridges can be combined into one relay to yield a custom-tailored application solution. Time delay, latching attachments, overlapping and logic reed contacts are available.

Bulletin 700-P relays use standard 10 A contact cartridges with a double-break and bifurcated design. Bifurcation provides excellent contact reliability and low contact bounce, while the double-break contact design reduced the possibility of contacts welding and enhances the relay’s ability to break DC circuits. These relays are supplied with a max. of 12 contacts (max. 8 N.C.).

Bulletin 700-PK master control relays contain 20 A master contact cartridges with large single-contact pads on each side of the spanner for twice the current rating to control heavy loads and for master control of a system. The Bulletin 700-PK relay also has the same double-break design as the -P relay. These relays are supplied with a max. of 12 contacts (max. 8 N.C.). Time delay and latching attachments are available.

Bulletin 700-P and -PK relays combine the advantages of convertible contacts with Direct Drive, a construction designed to maintain non-overlap operation between N.O. and N.C. contacts (within published ratings).

Bulletin 700-PH tandem contact relays include 35 A jumper kits (Cat. No. 700-CPH) to parallel two 20 A master contact cartridges. A maximum of six poles are supplied, up to four of which can be normally closed. Time delay and latch attachments are available.

Conformity to Standards: Approvals: IEC 947-5-1 CSA Certified IEC 337-1 CENELEC CSA File #LR1234 BS 4794 UL Listed VDE 0660 UL File #E14840, Guide NKCR Listed: U.S. Coast Guard and American CE Certified Bureau of Shipping 228

Your order must include: ° Cat. No. of the relay selected.

* Coil voltage suffix code.

¢ Ifrequired, Cat. No. of any accessories.

Allen-Bradley

Page 2

Bulletin 700-P, -PK, -PH

Industrial Relays Product Selection

Electrically Held Relays Bulletin 700-P Standard Contact Cartridge ➊ ➋ AC-Operated Relays Contacts N.O.

N.C.

2, 4, 6, 8, 10, 12, Contact Arrangement and Markings

K1 A1X ➌ A2X

A3X A4X ➌

K2

A3Y

4-Pole Relay

A1Y A2Y

B1X ➍ B2X

A4Y

B3X B4X

➍

8-Pole Relay

B1Y B2Y

B3Y

B4Y

C1X ➎ C2X

C3X C4X

C1Y C2Y

C3Y C4Y

➎

12-Pole Relay

Open Type – Without Enclosure Cat. No. ➊ ➏

Type 1 General Purpose Enclosure Cat. No. ➏

700-P200⊗

700-P201⊗

700-P400⊗

700-P401⊗

700-P600⊗

700-P601⊗

700-P800⊗

700-P801⊗

700-P1000⊗

700-P1001⊗

700-P1200⊗

700-P1201⊗

⊗ AC Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-P200⊗ becomes Cat. No. 700-P200A48. For other coil voltages, consult your local Allen-Bradley Sales Office.

Hz 50 60

24 48 110 110-115 115-120 120 127 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600 B24 B48 A1* B11†, - B27, B22 B2, - B3 B41 B44, B50, A24 A48, - A1* B11†, A20 A22 A2 A27 A35, - - A4, A6

* Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. † Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.

DC-Operated Relays Contacts N.O.

N.C.

2, 4, 6, 8, 10, 12, Open Type – Without Enclosure

Contact Arrangement and Markings

A3X A4X ➌

K2

A3Y

4-Pole Relay

B1X➍ B2X

A4Y

B3X B4X ➍

8-Pole Relay

B1Y B2Y

B3Y

B4Y

C1X➎ C2X

C3X C4X ➎

C1Y C2Y

C3Y C4Y

Cat. No. ➏

Cat. No. ➏

K1 A1X➌ A2X

A1Y A2Y

Type 1 General Purpose Enclosure

12-Pole Relay

700DC-P200⊗

700DC-P201⊗

700DC-P400⊗

700DC-P401⊗

700DC-P600⊗

700DC-P601⊗

700DC-P800⊗

700DC-P801⊗

700DC-P1000⊗, 700DC-P1200⊗, ⊗ DC Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-P200⊗ becomes Cat. No. 700DC-P200Z48. For other coil voltages, consult your local Allen-Bradley Sales Office. 6 Z06

12 Z12

18 Z18

24 Z24

32 Z32

48 Z48

64 Z64

72 Z72

90 Z90

115-125 Z1

230-250 Z2

500-550 Z5

575-600 Z6

➊ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. ➋ Overlap contacts: To order a relay containing one pair: Use Cat. No. 700-PZ110. To order a relay containing two pairs: Use Cat. No. 700-PZ2220. N.O. contact closes before N.C. contact opens. AC Ratings: NEMA A600, DC Ratings: P150. ➌ Location of contacts in 2-pole relays. ➍ Location of contacts in 6-pole relays: 4-pole relay plus the 2 contacts indicated. ➎ Location of contacts in 10-pole relays: 8-pole relay plus the 2 contacts indicated. ➏ All Cat. Nos. are factory stocked.

229

Page 3

Bulletin 700-P, -PK, -PH

Industrial Relays

Product Selection, Continued Electrically Held Relays Bulletin 700-PK Master Contact Cartridges ➊ AC-Operated Relays Contacts N.O.

N.C.

2, 4

Contact Arrangement and Markings

A1X ➋

A2X

A3X

A4X ➋

K2

A1Y

A2Y

A3Y

A4Y

4-Pole Relay, 6

K1, 8, 10, 12

B1X➌

B2X

B3X

B4X ➌

B1Y

B2Y

B3Y

B4Y

8-Pole Relay

C1X➍

C2X

C3X

C4X ➍

C1Y

C2Y

C3Y

C4Y

12-Pole Relay, Open Type – Without Enclosure Cat. No. ➎

Type 1 General Purpose Enclosure Cat. No. ➎

700-PK200⊗

700-PK201⊗

700-PK400⊗

700-PK401⊗

700-PK600⊗

700-PK601⊗

700-PK800⊗

700-PK801⊗

700-PK1000⊗

700-PK1001⊗

700-PK1200⊗

700-PK1201⊗

⊗ AC Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No.700-PK200⊗ becomes Cat. No. 700-PK200A48. For other coil voltages, consult your local Allen-Bradley Sales Office.

Hz

24

127 200-208 220-230 230-240 277 347 380

415 440-480 460-480 500 575-600

50

B24 B48 A1*

48

110 110-115 115-120 120 B11†, - B27, B22

B2, - B3

B41

B44, B50, 60

A24 A48, A1*

B11†, A20

A22

A2

A27 A35, - - A4, A6, * Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. † Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.

DC-Operated Relays Contacts N.O.

N.C.

2, 4, 6

K1

A1X ➋

A2X

A3X

A4X ➋

K2

A1Y

A2Y

A3Y

A4Y

4-Pole Relay, 8, 10, 12

Contact Arrangement and Markings, Open Type – Without Enclosure Cat. No. ➎

Type 1 General Purpose Enclosure Cat. No. ➎

700DC-PK200⊗

700DC-PK201⊗

700DC-PK400⊗

700DC-PK401⊗

700DC-PK600⊗

700DC-PK601⊗

700DC-PK800⊗

700DC-PK801⊗

B1X ➌

B2X

B3X

B4X ➌

B1Y

B2Y

B3Y

B4Y

C1X ➍ C2X

C3X

C4X ➍

700DC-PK1000⊗, C1Y

C3Y

C4Y

700DC-PK1200⊗, 8-Pole Relay

12-Pole Relay

C2Y

⊗ DC Voltage Suffix Code .

The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PK200⊗ becomes Cat. No. 700DC-PK200Z12. For other coil voltages, consult your local Allen-Bradley Sales Office 6

12

18

24

32

48

64

72

90

115-125

230-250

500-550

575-600

Z06

Z12

Z18

Z24

Z32

Z48

Z64

Z72

Z90

Z1

Z2

Z5

Z6

➊ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. ➋ Location of contacts in 2-pole relays. ➌ Location of contacts in 6-pole relays: 4-pole relay plus the 2 contacts indicated. ➍ Location of contacts in 10-pole relays: 8-pole relay plus the 2 contacts indicated. ➎ All Cat. Nos. are factory stocked.

230

Page 4

-

EMERGENCY STOP

L1

MASTER CONTROL RELAY

START

STOP

L2

MCR Surge Suppressor

MCR

MCR 20A

700-N5 or 700-N24

Standard Cartridge 700-CP1

L1

EMERGENCY STOP

MASTER CONTROL RELAY

START

STOP

MCR 20A

L2

MCR Surge Suppressor

MCR MCR 35A

700-N5 or 700-N24

Standard Cartridge 700-CP1

Latch

MCR 35A

Latch K1

K2 Reset

Unlatch K3

CRL

K4

CRL Control Heating Lighting Single Phase

Page 5

Bulletin 700-P, -PK, -PH

Industrial Relays

Product Selection, Continued Electrically Held Relays Bulletin 700-PH 35A Tandem Contact Cartridges ➊ ➌ AC-Operated Relays Contacts N.O.

N.C.

1, 2, 3, 4, Contact Arrangement and Markings

K1 A1X ➋

A2X

A3X

A4X

K2

A2Y A3Y

A4Y

B2X B3X

B4X

B2Y B3Y

B4Y

C2X

C4X

A1Y B1X➌, Type 1 General Purpose Enclosure Cat. No. ➎

700-PH100⊗

700-PH101⊗

700-PH200⊗

700-PH201⊗

700-PH300⊗

700-PH301⊗

700-PH400⊗

700-PH401⊗

700-PH600⊗

700-PH601⊗

4-Pole Relay

B1Y C1X➍

6

Open Type – Without Enclosure Cat. No. ➎

C3X

6-Pole Relay

Cat. No. 700-PH200

C1Y

C2Y C3Y

C4Y

⊗ AC Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-PH100⊗ becomes Cat. No. 700-PH100A48. For other coil voltages, consult your local Allen-Bradley Sales Office.

Hz

24

127 200-208 220-230 230-240 277 347 380

415 440-480 460-480 500 575-600

50

B24 B48 A1*

48

110 110-115 115-120 120 B11†, - B27, B22

B2, - B3

B41

B44, B50, 60

A24 A48, A1*

B11†, A20

A22

A2

A27 A35, - - A4, A6, * Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. † Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.

DC-Operated Relays

Contacts N.O.

N.C.

1, 2, 3, 4, Contact Arrangement and Markings

K1 A1X ➋

6, A4X

A3Y

A4Y

B2X B3X

B4X

B2Y B3Y

B4Y

C2X

C4X

K2 B1X➌ 4-Pole Relay

B1Y C1X➍

Cat. No. 700DC-PH200

A2X A3X

C3X

6-Pole Relay

C1Y

C2Y C3Y

Open Type – Without Enclosure Cat. No. ➎

Type 1 General Purpose Enclosure Cat. No. ➎

700DC-PH100⊗

700DC-PH101⊗

700DC-PH200⊗

700DC-PH201⊗

700DC-PH300⊗

700DC-PH301⊗

700DC-PH400⊗

700DC-PH401⊗

700DC-PH600⊗, C4Y

⊗ DC Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PH200⊗ becomes Cat. No. 700DC-PH200Z12. For other coil voltages, consult your local Allen-Bradley Sales Office. 6 Z06

12 Z12

18 Z18

24 Z24

32 Z32

48 Z48

64 Z64

72 Z72

90 Z90

115-125 Z1

230-250 Z2

500-550 Z5

575-600 Z6

➊ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. ➋ Location of contacts in 1-pole relays. ➌ Location of contacts in 3-pole relays: 2-pole relay plus the contact indicated. ➍ Location of contacts in 6-pole relays: 4-pole relay plus the 2 contacts indicated. ➎ All Cat. Nos. are factory stocked.

232

Page 6

Bulletin 700-P, -PK, -PH

Industrial Relays

Product Selection, Continued Time Delay Relays, Open Type With Pneumatic Time-Delay Attachment • Timing Options: (see pages 237 and 253) • Pneumatic Timers, Factory- or Field-Installed • Solid-State Timers, Field-Installed • Factory-Assembled Bulletin 700-PT and PKT Timing Relays • 0, 2, or 4 instantaneous contacts • 2 timed contacts, both ON Delay or both OFF Delay • Convertible from ON Delay to OFF Delay and vice versa • Standard contact cartridges rated NEMA A600 (AC) and P600 (DC) • Master contact cartridges rated 2X NEMA A600 (AC) and 2X P600 (DC) Bulletin 700-P Standard Contact Cartridge ➊ ➋ AC-Operated Relays Contacts

DC-Operated Relays

N.O.

N.C.

Contact Arrangement and Markings

0, Relay with only time delay contacts

2, 4, K1 A1X ➌ A2X

A3X A4X ➌ D1X D2X ➍

K2

A3Y

A1Y A2Y

Cat. No. ➏

Contact Arrangement and Markings

Cat. No. ➏

700-PPT⊗

Relay with only time delay contacts

700DC-PPT⊗

700-PT200⊗

K1 A1X

➌

A2X

A3X A4X

➌

700DC-PT200⊗

D1X D2X ➍

700-PT400⊗

A4Y D1Y D2Y

700DC-PT400⊗

K2

A1Y A2Y

A3Y

A4Y D1Y D2Y

Bulletin 700-PK Master Contact Cartridges ➊ AC-Operated Relays Contact Arrangement Relay with only time delay contacts

700-PPKT⊗

Contacts N.O.

N.C.

0, 2, 4, DC-Operated Relays Open Type Without Enclosure

Contact Arrangement

Open Type Without Enclosure

Relay with only time delay contacts

700DC-PPKT⊗

Cat. No. ➏

K1 A1X ➌ A2X

A3X A4X ➌

D1X D2X ➎

K2

A3Y

D1Y D2Y

A4Y

K1 A1X➌ A2X

A3X A4X ➌

D1X D2X ➎

K2

A3Y

D1Y D2Y

700-PKT200⊗ 700-PKT400⊗

A1Y A2Y

Cat. No. ➏

A1Y A2Y

A4Y

700DC-PKT200⊗ 700DC-PKT400⊗

⊗ AC Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No.700-PKT200⊗ becomes Cat. No. 700-PKT200A48. For other coil voltages, consult your local Allen-Bradley Sales Office.

Hz

24

127 200-208 220-230 230-240 277 347 380

415 440-480 460-480 500 575-600

50

B24 B48 A1*

48

110 110-115 115-120 120 B11†, - B27, B22

B2, - B3

B41

B44, B50, 60

A24 A48, A1*

B11†, A20

A22

A2

A27 A35, - - A4, A6, * Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. † Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.

⊗ DC Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PKT200⊗ becomes Cat. No. 700DC-PKT200Z12. For other coil voltages, consult your local Allen-Bradley Sales Office. 6

12

18

24

32

48

64

72

90

115-125

230-250

500-550

575-600

Z06

Z12

Z18

Z24

Z32

Z48

Z64

Z72

Z90

Z1

Z2

Z5

Z6

➊ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. ➋ Overlap contacts: N.O. contact closes before N.C. contact opens. To order a relay containing one pair: Use Cat. No. 700-PTZ110. To order a relay containing two pairs: Use Cat. No. 700-PTZ2220. AC Ratings: NEMA A600, DC Ratings: P150. ➌ Location of contacts in 2-pole relays. ➍ Timer has 1 N.O. and 1 N.C. convertible cartridge in addition to the instantaneous cartridges on the relay. Timer is supplied as On-Delay. Convertible to Off-Delay in the field. ➎ The timer has 1 N.O. and 1 N.C convertible master cartridge in addition to the instantaneous master cartridges on the relay. Timer is supplied as On-Delay. It is convertible to Off-Delay in the field. ➏ All Cat. Nos. are factory stocked.

233

Page 7

Bulletin 700-P, -PK, -PH

Industrial Relays

Product Selection, Continued Mechanical Latching Relays • • • • • •

Mechanical latch options, factory- or field-installed Converts all poles to latching AC latch coil, max. 6 poles latching DC latch coil, max. 5 poles latching Latching relays have 2 coils, latch coil is the relay coil, reset coil is on the latch attachment Latch/reset coils can have 2 AC coils, 2 DC coils, or 1 AC and 1 DC coil (e.g., latch with AC power, unlatch with DC battery)

Bulletin 700-P Standard Contact Cartridge ➊ ➋ AC-Operated Relays Contacts

Contact Arrangement and Markings

N.O.

N.C.

0, 2, 4, DC-Operated Relays Open Type with Mechanical Latch Attachment (Read ATTENTION Below)

Open Type with Mechanical Latch Attachment (Read ATTENTION Below)

Contact Arrangement and Markings

Cat. No. ➏, Cat. No. ➏, K1 A1X A2X A3X A4X D1X D2X K3 ➍

➍

➌ ➌

K2 A1Y A2Y A3Y A4Y D1Y D2Y K4, - 700-PL200⊗

K1 A1X A2X A3X A4X D1X D2X ➌ ➍ ➍ ➌

700-PL400⊗

K2 A1Y A2Y A3Y A4Y D1Y

K3

K4

D2Y 6, 6-pole Relay

700-PL600⊗

5-pole Relay

700DC-PL200⊗ 700DC-PL400⊗ 700DC-PL500⊗

⊗ AC Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-PT200⊗ becomes Cat. No. 700-PT200A48. For other coil voltages, consult your local Allen-Bradley Sales Office. Relays with latch attachments: if the latch attachment coil is to be a different voltage other than the relay coil, add a second coil code suffix. Example: Cat. No. 700-PL400A1A24. Only one suffix is required if both coils are the same voltage.

Hz

24

50

B24 B48 A1*

48

110 110-115 115-120 120 B11†, - B27, B22

B2, - B3

B41

B44, B50, 60

A24 A48, A1*

B11†, A20

A22

A2

A27 A35, - - A4, A6, 127 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600

* Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. † Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.

⊗ DC Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PT200⊗ becomes Cat. No. 700DC-PT200Z12. For other coil voltages, consult your local Allen-Bradley Sales Office. 6

12

18

24

32

48

64

72

90

115-125

230-250

500-550

575-600

Z06

Z12

Z18

Z24

Z32

Z48

Z64

Z72

Z90

Z1

Z2

Z5

Z6

➊ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. ➋ Overlap contacts: To order a relay containing one pair: Use Cat. No. 700-PTZ110. To order a relay containing two pairs: Use Cat. No. 700-PTZ2220. N.O. contact closes before N.C. contact opens. AC Ratings: NEMA A600, DC Ratings: P150. ➌ Location of contacts in 2-pole relays. ➍ Location of contacts in 4-pole relays: 2-pole relay plus the 2 contacts indicated. ➏ All Cat. Nos. are factory stocked.

ATTENTION – An open or failed unlatch control circuit will fail to unlatch the relay. For this reason, a mechanical latch unit should not be used where protection is needed against automatic restart after a power failure or where reliability to a control function is critical to safety.

234

Page 8 read from a scan by OCR; it may hold reading errors

Bulletin 700-P, -PK, -PH

Industrial Relays Product Selection, Continued

700S-P Safety Control Relays

Contacts Relays with 120V AC Coils N.O. N.C. Cat. No. 1 700S-P310A1 2 2 700S-P220A1 6 2 700S-P620A1 5 3 700S-P530A1 Contacts Relays with 24V DC Coils N.O. N.C. Cat. No. 3 1 700S-DCP310Z24 2 2 700S-DCP220Z24 6 2 700S-DCP620Z24 5 3 700S-DCP530Z24 Accessories Continuous Pk Description Carrying Product Label Onn Cat.No. @ Current (A) y- 10 Acartridge meeting IEC 947-5 ® L _ Note: Use this cartridge when full compliance to \ PSS f IEC 947-5 is required. M ni) ° 700-P relays equipped with CPS cartridges fully 10 ane 700-CPS meet the IEC 947-5 spec for mechanically linked contacts. 8 ©

@ IEC 947-5 Annex L has 2 requirements for a relay to meet for mechanically linked contacts: 1.) Ifa N.O. contact welds, all the N.C. contacts will remain open and meet a 2500V impulse test. 2.) Ifa N.C. contact welds, all the N.O. contacts will remain open and meet a 2500V impulse test. 700-P relays equipped with the 700-CPS cartridge meet these requirements including the 2500V impulse test. @ The relays shown on this page are shipped from the factory with the 700-CPS cartridge installed. Relays with factory-installed 700-CPS cartridges have the international symbol (shown below) for mechanically linked contacts prominently displayed on the face plate. ® These cartridges must not be used in timers and latches.

@ All Cat. Nos. are factory stocked.

International Symbol for Mechanically Linked Contacts

Allen-Bradley 235