The text of a spec sheet · part 1 of 2
Bulletin 700-P, -PK, -PH Industrial Relays, pages 1 to 8
Pages 1 to 8 of 15
The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 700-PB40
Page 1
Bulletin 700-P, -PK, -PH Industrial Relays
Cat. No. 700-PH200 “=
Cat. No. 700-PK400A1
AQ = \S)
TABLE OF CONTENTS
Bulletin 700
Direct Drive™ Convertible Contact Cartridge Relays NEMA and IEC Ratings 600V Maximum AC/DC Contact Ratings:
¢ 10 A 700-CP1-and 700-CPS e 20 A 700-CPM
¢ 35 A 700-CPH e Low Power 700-CPR Easy Accessory Additions: e Adder Decks e Time Delay e Latching
¢« Surge Suppressors e Mounting Strip
For Machine Tool and Other Heavy Duty Applications
Can Accommodate Ring Tongue Terminals
Expands Safety Relay Outputs
Description Page | Description Page Product Selection Accessories ...... 0.0... 0.0.0 235 Electrically Held Relays ......... 0.00.00 0 cece eee eae 229 | Specifications .............. 0.000 ee 240 Time Delay Relays........... 0.0.0.0 cece eee eee eee 233 Operating Coils... 1.2.0.0... 000.00 c eee 241 Safety Control Relays ............ 0.0000: e eee eee eee 235 | Approximate Dimensions .......................-0020005 242 Description
The Bulletin 700-P family of relays has 4 types of contact cartridges to meet your specific switching requirements. Different cartridges can be combined into one relay to yield a custom-tailored application solution. Time delay, latching attachments, overlapping and logic reed contacts are available.
Bulletin 700-P relays use standard 10 A contact cartridges with a double-break and bifurcated design. Bifurcation provides excellent contact reliability and low contact bounce, while the double-break contact design reduced the possibility of contacts welding and enhances the relay’s ability to break DC circuits. These relays are supplied with a max. of 12 contacts (max. 8 N.C.).
Bulletin 700-PK master control relays contain 20 A master contact cartridges with large single-contact pads on each side of the spanner for twice the current rating to control heavy loads and for master control of a system. The Bulletin 700-PK relay also has the same double-break design as the -P relay. These relays are supplied with a max. of 12 contacts (max. 8 N.C.). Time delay and latching attachments are available.
Bulletin 700-P and -PK relays combine the advantages of convertible contacts with Direct Drive, a construction designed to maintain non-overlap operation between N.O. and N.C. contacts (within published ratings).
Bulletin 700-PH tandem contact relays include 35 A jumper kits (Cat. No. 700-CPH) to parallel two 20 A master contact cartridges. A maximum of six poles are supplied, up to four of which can be normally closed. Time delay and latch attachments are available.
Conformity to Standards: Approvals: IEC 947-5-1 CSA Certified IEC 337-1 CENELEC CSA File #LR1234 BS 4794 UL Listed VDE 0660 UL File #E14840, Guide NKCR Listed: U.S. Coast Guard and American CE Certified Bureau of Shipping 228
Your order must include: ° Cat. No. of the relay selected.
* Coil voltage suffix code.
¢ Ifrequired, Cat. No. of any accessories.
Allen-Bradley
Page 2
Bulletin 700-P, -PK, -PH
Industrial Relays Product Selection
Electrically Held Relays Bulletin 700-P Standard Contact Cartridge ➊ ➋ AC-Operated Relays Contacts N.O.
N.C.
2, 4, 6, 8, 10, 12, Contact Arrangement and Markings
K1 A1X ➌ A2X
A3X A4X ➌
K2
A3Y
4-Pole Relay
A1Y A2Y
B1X ➍ B2X
A4Y
B3X B4X
➍
8-Pole Relay
B1Y B2Y
B3Y
B4Y
C1X ➎ C2X
C3X C4X
C1Y C2Y
C3Y C4Y
➎
12-Pole Relay
Open Type – Without Enclosure Cat. No. ➊ ➏
Type 1 General Purpose Enclosure Cat. No. ➏
700-P200⊗
700-P201⊗
700-P400⊗
700-P401⊗
700-P600⊗
700-P601⊗
700-P800⊗
700-P801⊗
700-P1000⊗
700-P1001⊗
700-P1200⊗
700-P1201⊗
⊗ AC Voltage Suffix Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-P200⊗ becomes Cat. No. 700-P200A48. For other coil voltages, consult your local Allen-Bradley Sales Office.
Hz 50 60
24 48 110 110-115 115-120 120 127 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600 B24 B48 A1* B11†, - B27, B22 B2, - B3 B41 B44, B50, A24 A48, - A1* B11†, A20 A22 A2 A27 A35, - - A4, A6
* Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. † Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.
DC-Operated Relays Contacts N.O.
N.C.
2, 4, 6, 8, 10, 12, Open Type – Without Enclosure
Contact Arrangement and Markings
A3X A4X ➌
K2
A3Y
4-Pole Relay
B1X➍ B2X
A4Y
B3X B4X ➍
8-Pole Relay
B1Y B2Y
B3Y
B4Y
C1X➎ C2X
C3X C4X ➎
C1Y C2Y
C3Y C4Y
Cat. No. ➏
Cat. No. ➏
K1 A1X➌ A2X
A1Y A2Y
Type 1 General Purpose Enclosure
12-Pole Relay
700DC-P200⊗
700DC-P201⊗
700DC-P400⊗
700DC-P401⊗
700DC-P600⊗
700DC-P601⊗
700DC-P800⊗
700DC-P801⊗
700DC-P1000⊗, 700DC-P1200⊗, ⊗ DC Voltage Suffix Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-P200⊗ becomes Cat. No. 700DC-P200Z48. For other coil voltages, consult your local Allen-Bradley Sales Office. 6 Z06
12 Z12
18 Z18
24 Z24
32 Z32
48 Z48
64 Z64
72 Z72
90 Z90
115-125 Z1
230-250 Z2
500-550 Z5
575-600 Z6
➊ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. ➋ Overlap contacts: To order a relay containing one pair: Use Cat. No. 700-PZ110. To order a relay containing two pairs: Use Cat. No. 700-PZ2220. N.O. contact closes before N.C. contact opens. AC Ratings: NEMA A600, DC Ratings: P150. ➌ Location of contacts in 2-pole relays. ➍ Location of contacts in 6-pole relays: 4-pole relay plus the 2 contacts indicated. ➎ Location of contacts in 10-pole relays: 8-pole relay plus the 2 contacts indicated. ➏ All Cat. Nos. are factory stocked.
229
Page 3
Bulletin 700-P, -PK, -PH
Industrial Relays
Product Selection, Continued Electrically Held Relays Bulletin 700-PK Master Contact Cartridges ➊ AC-Operated Relays Contacts N.O.
N.C.
2, 4
Contact Arrangement and Markings
A1X ➋
A2X
A3X
A4X ➋
K2
A1Y
A2Y
A3Y
A4Y
4-Pole Relay, 6
K1, 8, 10, 12
B1X➌
B2X
B3X
B4X ➌
B1Y
B2Y
B3Y
B4Y
8-Pole Relay
C1X➍
C2X
C3X
C4X ➍
C1Y
C2Y
C3Y
C4Y
12-Pole Relay, Open Type – Without Enclosure Cat. No. ➎
Type 1 General Purpose Enclosure Cat. No. ➎
700-PK200⊗
700-PK201⊗
700-PK400⊗
700-PK401⊗
700-PK600⊗
700-PK601⊗
700-PK800⊗
700-PK801⊗
700-PK1000⊗
700-PK1001⊗
700-PK1200⊗
700-PK1201⊗
⊗ AC Voltage Suffix Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No.700-PK200⊗ becomes Cat. No. 700-PK200A48. For other coil voltages, consult your local Allen-Bradley Sales Office.
Hz
24
127 200-208 220-230 230-240 277 347 380
415 440-480 460-480 500 575-600
50
B24 B48 A1*
48
110 110-115 115-120 120 B11†, - B27, B22
B2, - B3
B41
B44, B50, 60
A24 A48, A1*
B11†, A20
A22
A2
A27 A35, - - A4, A6, * Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. † Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.
DC-Operated Relays Contacts N.O.
N.C.
2, 4, 6
K1
A1X ➋
A2X
A3X
A4X ➋
K2
A1Y
A2Y
A3Y
A4Y
4-Pole Relay, 8, 10, 12
Contact Arrangement and Markings, Open Type – Without Enclosure Cat. No. ➎
Type 1 General Purpose Enclosure Cat. No. ➎
700DC-PK200⊗
700DC-PK201⊗
700DC-PK400⊗
700DC-PK401⊗
700DC-PK600⊗
700DC-PK601⊗
700DC-PK800⊗
700DC-PK801⊗
B1X ➌
B2X
B3X
B4X ➌
B1Y
B2Y
B3Y
B4Y
C1X ➍ C2X
C3X
C4X ➍
700DC-PK1000⊗, C1Y
C3Y
C4Y
700DC-PK1200⊗, 8-Pole Relay
12-Pole Relay
C2Y
⊗ DC Voltage Suffix Code .
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PK200⊗ becomes Cat. No. 700DC-PK200Z12. For other coil voltages, consult your local Allen-Bradley Sales Office 6
12
18
24
32
48
64
72
90
115-125
230-250
500-550
575-600
Z06
Z12
Z18
Z24
Z32
Z48
Z64
Z72
Z90
Z1
Z2
Z5
Z6
➊ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. ➋ Location of contacts in 2-pole relays. ➌ Location of contacts in 6-pole relays: 4-pole relay plus the 2 contacts indicated. ➍ Location of contacts in 10-pole relays: 8-pole relay plus the 2 contacts indicated. ➎ All Cat. Nos. are factory stocked.
230
Page 4
-
EMERGENCY STOP
L1
MASTER CONTROL RELAY
START
STOP
L2
MCR Surge Suppressor
MCR
MCR 20A
700-N5 or 700-N24
Standard Cartridge 700-CP1
L1
EMERGENCY STOP
MASTER CONTROL RELAY
START
STOP
MCR 20A
L2
MCR Surge Suppressor
MCR MCR 35A
700-N5 or 700-N24
Standard Cartridge 700-CP1
Latch
MCR 35A
Latch K1
K2 Reset
Unlatch K3
CRL
K4
CRL Control Heating Lighting Single Phase
Page 5
Bulletin 700-P, -PK, -PH
Industrial Relays
Product Selection, Continued Electrically Held Relays Bulletin 700-PH 35A Tandem Contact Cartridges ➊ ➌ AC-Operated Relays Contacts N.O.
N.C.
1, 2, 3, 4, Contact Arrangement and Markings
K1 A1X ➋
A2X
A3X
A4X
K2
A2Y A3Y
A4Y
B2X B3X
B4X
B2Y B3Y
B4Y
C2X
C4X
A1Y B1X➌, Type 1 General Purpose Enclosure Cat. No. ➎
700-PH100⊗
700-PH101⊗
700-PH200⊗
700-PH201⊗
700-PH300⊗
700-PH301⊗
700-PH400⊗
700-PH401⊗
700-PH600⊗
700-PH601⊗
4-Pole Relay
B1Y C1X➍
6
Open Type – Without Enclosure Cat. No. ➎
C3X
6-Pole Relay
Cat. No. 700-PH200
C1Y
C2Y C3Y
C4Y
⊗ AC Voltage Suffix Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-PH100⊗ becomes Cat. No. 700-PH100A48. For other coil voltages, consult your local Allen-Bradley Sales Office.
Hz
24
127 200-208 220-230 230-240 277 347 380
415 440-480 460-480 500 575-600
50
B24 B48 A1*
48
110 110-115 115-120 120 B11†, - B27, B22
B2, - B3
B41
B44, B50, 60
A24 A48, A1*
B11†, A20
A22
A2
A27 A35, - - A4, A6, * Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. † Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.
DC-Operated Relays
Contacts N.O.
N.C.
1, 2, 3, 4, Contact Arrangement and Markings
K1 A1X ➋
6, A4X
A3Y
A4Y
B2X B3X
B4X
B2Y B3Y
B4Y
C2X
C4X
K2 B1X➌ 4-Pole Relay
B1Y C1X➍
Cat. No. 700DC-PH200
A2X A3X
C3X
6-Pole Relay
C1Y
C2Y C3Y
Open Type – Without Enclosure Cat. No. ➎
Type 1 General Purpose Enclosure Cat. No. ➎
700DC-PH100⊗
700DC-PH101⊗
700DC-PH200⊗
700DC-PH201⊗
700DC-PH300⊗
700DC-PH301⊗
700DC-PH400⊗
700DC-PH401⊗
700DC-PH600⊗, C4Y
⊗ DC Voltage Suffix Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PH200⊗ becomes Cat. No. 700DC-PH200Z12. For other coil voltages, consult your local Allen-Bradley Sales Office. 6 Z06
12 Z12
18 Z18
24 Z24
32 Z32
48 Z48
64 Z64
72 Z72
90 Z90
115-125 Z1
230-250 Z2
500-550 Z5
575-600 Z6
➊ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. ➋ Location of contacts in 1-pole relays. ➌ Location of contacts in 3-pole relays: 2-pole relay plus the contact indicated. ➍ Location of contacts in 6-pole relays: 4-pole relay plus the 2 contacts indicated. ➎ All Cat. Nos. are factory stocked.
232
Page 6
Bulletin 700-P, -PK, -PH
Industrial Relays
Product Selection, Continued Time Delay Relays, Open Type With Pneumatic Time-Delay Attachment • Timing Options: (see pages 237 and 253) • Pneumatic Timers, Factory- or Field-Installed • Solid-State Timers, Field-Installed • Factory-Assembled Bulletin 700-PT and PKT Timing Relays • 0, 2, or 4 instantaneous contacts • 2 timed contacts, both ON Delay or both OFF Delay • Convertible from ON Delay to OFF Delay and vice versa • Standard contact cartridges rated NEMA A600 (AC) and P600 (DC) • Master contact cartridges rated 2X NEMA A600 (AC) and 2X P600 (DC) Bulletin 700-P Standard Contact Cartridge ➊ ➋ AC-Operated Relays Contacts
DC-Operated Relays
N.O.
N.C.
Contact Arrangement and Markings
0, Relay with only time delay contacts
2, 4, K1 A1X ➌ A2X
A3X A4X ➌ D1X D2X ➍
K2
A3Y
A1Y A2Y
Cat. No. ➏
Contact Arrangement and Markings
Cat. No. ➏
700-PPT⊗
Relay with only time delay contacts
700DC-PPT⊗
700-PT200⊗
K1 A1X
➌
A2X
A3X A4X
➌
700DC-PT200⊗
D1X D2X ➍
700-PT400⊗
A4Y D1Y D2Y
700DC-PT400⊗
K2
A1Y A2Y
A3Y
A4Y D1Y D2Y
Bulletin 700-PK Master Contact Cartridges ➊ AC-Operated Relays Contact Arrangement Relay with only time delay contacts
700-PPKT⊗
Contacts N.O.
N.C.
0, 2, 4, DC-Operated Relays Open Type Without Enclosure
Contact Arrangement
Open Type Without Enclosure
Relay with only time delay contacts
700DC-PPKT⊗
Cat. No. ➏
K1 A1X ➌ A2X
A3X A4X ➌
D1X D2X ➎
K2
A3Y
D1Y D2Y
A4Y
K1 A1X➌ A2X
A3X A4X ➌
D1X D2X ➎
K2
A3Y
D1Y D2Y
700-PKT200⊗ 700-PKT400⊗
A1Y A2Y
Cat. No. ➏
A1Y A2Y
A4Y
700DC-PKT200⊗ 700DC-PKT400⊗
⊗ AC Voltage Suffix Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No.700-PKT200⊗ becomes Cat. No. 700-PKT200A48. For other coil voltages, consult your local Allen-Bradley Sales Office.
Hz
24
127 200-208 220-230 230-240 277 347 380
415 440-480 460-480 500 575-600
50
B24 B48 A1*
48
110 110-115 115-120 120 B11†, - B27, B22
B2, - B3
B41
B44, B50, 60
A24 A48, A1*
B11†, A20
A22
A2
A27 A35, - - A4, A6, * Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. † Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.
⊗ DC Voltage Suffix Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PKT200⊗ becomes Cat. No. 700DC-PKT200Z12. For other coil voltages, consult your local Allen-Bradley Sales Office. 6
12
18
24
32
48
64
72
90
115-125
230-250
500-550
575-600
Z06
Z12
Z18
Z24
Z32
Z48
Z64
Z72
Z90
Z1
Z2
Z5
Z6
➊ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. ➋ Overlap contacts: N.O. contact closes before N.C. contact opens. To order a relay containing one pair: Use Cat. No. 700-PTZ110. To order a relay containing two pairs: Use Cat. No. 700-PTZ2220. AC Ratings: NEMA A600, DC Ratings: P150. ➌ Location of contacts in 2-pole relays. ➍ Timer has 1 N.O. and 1 N.C. convertible cartridge in addition to the instantaneous cartridges on the relay. Timer is supplied as On-Delay. Convertible to Off-Delay in the field. ➎ The timer has 1 N.O. and 1 N.C convertible master cartridge in addition to the instantaneous master cartridges on the relay. Timer is supplied as On-Delay. It is convertible to Off-Delay in the field. ➏ All Cat. Nos. are factory stocked.
233
Page 7
Bulletin 700-P, -PK, -PH
Industrial Relays
Product Selection, Continued Mechanical Latching Relays • • • • • •
Mechanical latch options, factory- or field-installed Converts all poles to latching AC latch coil, max. 6 poles latching DC latch coil, max. 5 poles latching Latching relays have 2 coils, latch coil is the relay coil, reset coil is on the latch attachment Latch/reset coils can have 2 AC coils, 2 DC coils, or 1 AC and 1 DC coil (e.g., latch with AC power, unlatch with DC battery)
Bulletin 700-P Standard Contact Cartridge ➊ ➋ AC-Operated Relays Contacts
Contact Arrangement and Markings
N.O.
N.C.
0, 2, 4, DC-Operated Relays Open Type with Mechanical Latch Attachment (Read ATTENTION Below)
Open Type with Mechanical Latch Attachment (Read ATTENTION Below)
Contact Arrangement and Markings
Cat. No. ➏, Cat. No. ➏, K1 A1X A2X A3X A4X D1X D2X K3 ➍
➍
➌ ➌
K2 A1Y A2Y A3Y A4Y D1Y D2Y K4, - 700-PL200⊗
K1 A1X A2X A3X A4X D1X D2X ➌ ➍ ➍ ➌
700-PL400⊗
K2 A1Y A2Y A3Y A4Y D1Y
K3
K4
D2Y 6, 6-pole Relay
700-PL600⊗
5-pole Relay
700DC-PL200⊗ 700DC-PL400⊗ 700DC-PL500⊗
⊗ AC Voltage Suffix Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-PT200⊗ becomes Cat. No. 700-PT200A48. For other coil voltages, consult your local Allen-Bradley Sales Office. Relays with latch attachments: if the latch attachment coil is to be a different voltage other than the relay coil, add a second coil code suffix. Example: Cat. No. 700-PL400A1A24. Only one suffix is required if both coils are the same voltage.
Hz
24
50
B24 B48 A1*
48
110 110-115 115-120 120 B11†, - B27, B22
B2, - B3
B41
B44, B50, 60
A24 A48, A1*
B11†, A20
A22
A2
A27 A35, - - A4, A6, 127 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600
* Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. † Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.
⊗ DC Voltage Suffix Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PT200⊗ becomes Cat. No. 700DC-PT200Z12. For other coil voltages, consult your local Allen-Bradley Sales Office. 6
12
18
24
32
48
64
72
90
115-125
230-250
500-550
575-600
Z06
Z12
Z18
Z24
Z32
Z48
Z64
Z72
Z90
Z1
Z2
Z5
Z6
➊ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. ➋ Overlap contacts: To order a relay containing one pair: Use Cat. No. 700-PTZ110. To order a relay containing two pairs: Use Cat. No. 700-PTZ2220. N.O. contact closes before N.C. contact opens. AC Ratings: NEMA A600, DC Ratings: P150. ➌ Location of contacts in 2-pole relays. ➍ Location of contacts in 4-pole relays: 2-pole relay plus the 2 contacts indicated. ➏ All Cat. Nos. are factory stocked.
ATTENTION – An open or failed unlatch control circuit will fail to unlatch the relay. For this reason, a mechanical latch unit should not be used where protection is needed against automatic restart after a power failure or where reliability to a control function is critical to safety.
234
Page 8
Bulletin 700-P, -PK, -PH
Industrial Relays Product Selection, Continued
700S-P Safety Control Relays
Contacts Relays with 120V AC Coils N.O. N.C. Cat. No. 1 700S-P310A1 2 2 700S-P220A1 6 2 700S-P620A1 5 3 700S-P530A1 Contacts Relays with 24V DC Coils N.O. N.C. Cat. No. 3 1 700S-DCP310Z24 2 2 700S-DCP220Z24 6 2 700S-DCP620Z24 5 3 700S-DCP530Z24 Accessories Continuous Pk Description Carrying Product Label Onn Cat.No. @ Current (A) y- 10 Acartridge meeting IEC 947-5 ® L _ Note: Use this cartridge when full compliance to \ PSS f IEC 947-5 is required. M ni) ° 700-P relays equipped with CPS cartridges fully 10 ane 700-CPS meet the IEC 947-5 spec for mechanically linked contacts. 8 ©
@ IEC 947-5 Annex L has 2 requirements for a relay to meet for mechanically linked contacts: 1.) Ifa N.O. contact welds, all the N.C. contacts will remain open and meet a 2500V impulse test. 2.) Ifa N.C. contact welds, all the N.O. contacts will remain open and meet a 2500V impulse test. 700-P relays equipped with the 700-CPS cartridge meet these requirements including the 2500V impulse test. @ The relays shown on this page are shipped from the factory with the 700-CPS cartridge installed. Relays with factory-installed 700-CPS cartridges have the international symbol (shown below) for mechanically linked contacts prominently displayed on the face plate. ® These cartridges must not be used in timers and latches.
@ All Cat. Nos. are factory stocked.
International Symbol for Mechanically Linked Contacts
Allen-Bradley 235