The text of a spec sheet · part 2 of 2
Bulletin 700S-CF, Bulletin 700S-P Safety Control Relays, pages 9 to 16
Pages 9 to 16 of 16
The original document is the PDF (5.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 700S-CF620DC
Page 9
Bulletin 700S-P
Safety Control Relays Product Selection Type S-P Safety Control Relays, AC and DC Coil Voltages
Connection Diagrams and terminal markings Coil and Main Contacts
K1
A1Y A2Y A3Y A4Y
K1
A1X
K1
K2
K1
A2X A3X
A1Y
A2Y
A1X
A1Y
24V DC Coils
Cat. No. ➊
Cat. No. ➊
N.O.
N.C., - 3
1
700S-P310⊗
700S-DCP310Z24, - 2
2
700S-P220⊗
700S-DCP220Z24
A3Y, 7
1
700S-P710⊗
700S-DCP710Z24, 6
2
700S-P620⊗
700S-DCP620Z24, 5
3
700S-P530⊗
700S-DCP530Z24, 4
4
700S-P440⊗
700S-DCP440Z24, 3
5
700S-P350⊗
700S-DCP350Z24
10
2
700S-P1020⊗
700S-DCP1020Z24
A4Y
A4X
A2Y
A3Y
A1X A2X A3X
A4X
A4Y
B1X
B2X
B3X
B4X
B1Y
B2Y
B3Y
B4Y
B1X
B2X
B3X
B4X
K2
A1Y A2Y A3Y A4Y
B1Y
B2Y
B3Y
B4Y
K1
A1X
B1X
B2X
B3X
B4X
A2X A3X
A4X
K2
A1Y
A2Y
A3Y
A4Y
B1Y
B2Y
B3Y
B4Y
K1
A1X
A2X A3X
A4X
B1X
B2X
B3X
B4X
K2
A1Y
K1
A1X A2X A3X
K2
AC Coils
A4X
A2X A3X
A2Y
Contacts Additional Contacts
A4X
K2
K2
þ
A1X A2X A3X
Additional Contacts
A3Y
A4Y
B1Y
B2Y
B3Y
B4Y
B1X
B2X
B3X
B4X
A4X
A1Y A2Y A3Y A4Y
K1
A1X
A2X A3X
A4X
K2
A1Y
A2Y
A4Y
A3Y
B1Y
B2Y
B3Y
B4Y
B1X
B2X
B3X
B4X
C1X
C2X
C3X
C4X
B1Y
B2Y
B3Y
B4Y
C1Y
C2Y
C3Y
C4Y
For other coil voltages, consult your local Allen-Bradley Sales Office.
➊ For other coil voltages, consult your local Allen-Bradley Sales Office.
⊗ AC Voltage Suffix Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700S-P310 becomes Cat. No. 700S-P310A1 for a 120V AC coil. Hz 60
24 A24
115-120 A1
230-240 A2
277 A27
460-480 A4
9
Page 10
Bulletin 700S-P
Safety Control Relays Specifications
Type
700S-P Electrical 10 A @ 600V AC 5 A @ 600V DC
Contact Rating Continuous Ratings Make/Break
AC
NEMA A600
DC
NEMA P600
Minimum Contact Switching Ratings
10V, 50 mA Volts DC
Contacts in Series DC Switching
24
64
125
250
500
600
1
5A
2.2 A
1.1 A
.55 A
.24 A
.2 A
2
10 A
10 A
5A
2A
.7 A
.5 A
3, - 7A
3A
1.5 A
1.0 A
4, - 10 A
5A
2.5 A
1.5 A
1.5 million operations at 10A break at 120V AC 14 million operations at 1A break at 120V AC 6 million operations at 1A break at 24V DC
Contact Electrical Life - Resistive Loads
Coil Voltage Range ➊
Coil Consumption
AC DC
AC
85…110%
DC
80…110%
Battery Charging
85…115% 50 Hz
60 Hz
Inrush
132 VA
138 VA
Sealed
19.3 VA
Inrush
19 VA 12.7 W
Sealed
12.7 W
Mechanical Mechanically Linked Contacts
All contacts are mechanically linked per IEC 947-5-1 annex L for 2 to 12 poles Pickup
AC – 10…20 ms DC – 30…50 ms
Dropout
AC – 10…20 ms DC – 20…33 ms
Operating Time
12.5 million operations ➌
Mechanical Life
Construction 2 to 12 Poles, Double Break Contacts N.O. or N.C. (8 N.C. Maximum)
Contact Arrangement Contact Material/Design
Silver Nickel/Bifurcated Panel mount or mount on 700-MP Rail Horizontal Mounting Recommended
Mounting
Environmental Operating ➋
–20…+65°C (–4…149°F)
Temperature Storage
–40…+65°C (–40…149°F)
Wire Terminations Wire size per UL/CSA
1X #18 AWG…2X #12 AWG
Tightening Torque
8…12 lb-in. (0.9…1.4 N•m)
➊ Coil voltage required for proper operation (percent of rated coil voltage). ➋ Temperature inside the panel. ➌ 90% of devices are expected to meet or exceed 12.5 million operations, and 50% of devices are are expected to meet 20 million operations.
10
Page 11
Bulletin 700S-P
Safety Control Relays Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
AC – 97.63 (3-27/32) DC – 120.49 (4-3/4)
57.15 (2-1/4)
7.94 (5/16)
89.69 (3-17/32) 79.38 (3-1/8)
Provision for 2–#8/#10 Mfg. Screws
2-pole and 4-pole Bulletin 700S-P Relay Approximate Shipping Weight AC – 0.68 kg (1.5 lbs.), DC – 1.34 kg (2.95 lbs.) AC – 130.97 (5-5/32) 57.15 (2-1/4)
DC – 153.83 (6-1/16)
7.94 (5/16)
89.63 (3-17/32) 79.38 (3-1/8)
Provision for 2–#8/#10 Mfg. Screws
6- and 8-pole Bulletin 700S-P Relay Approximate Shipping Weight AC – 0.79 kg (1.75 lbs.), DC – 1.45 kg (3.20 lbs.) AC – 164.31 (6-15/32) DC – 187.17 (7-3/8)
57.15 (2-1/4)
7.94 (5/16)
89.69 (3-17/32) 79.38 (3-1/8)
Provision for 2–#8/#10 Mfg. Screws
10- and 12-pole Bulletin 700S-P Relay Approximate Shipping Weight AC – 1.02 kg (2.25 lbs.), DC – 1.68 kg (3.7 lbs.) Cat. No. 700 34.93 (1-3/8)
{
-MP4 229 (9) -MP8 457 (18) -MP12 686 (27) -MP16 914 (36)
92.08 (3-5/8)
12.7 (1/2)
28.58 (1-1/8)
57.15 (2-1/4)
57.15 (2-1/4)
#8 Screws (Captive)
Universal Mounting Rail for Bulletin 700-P, -PH, -PK, and 700S-P relays. Secure the mounting strip with 2 screws at each end relay position. Use a minimum of one screw at the 3rd, 5th, 7th, etc., relay positions. Alternate between upper and lower horizontal slots.
11
Page 12
Bulletin 700S
Safety Control Relays Overview Safety Relay Output Block Diagram This diagram illustrates how 2 700S safety control relays can be used to expand Allen-Bradely Bulletin 440 safety relay outputs.
Safety Relay Output
K
K
K
13
14 X1
A1
1CR
A2
X2 1CR 21
2CR 22
21
22
A1
2CR
A2
Interlock
SAFETY OUTPUTS 1 CR
2 CR
13
14
13
14
33
34
33
36
43
44
43
44
53
54
53
54
63
64
63
64
73
74
73
74
83
84
83
84
LOAD 1 LOAD 2 LOAD 3 LOAD 4 LOAD 5 LOAD 6 LOAD 7
CR = Industrial Relay ( 700S-P, 700S-CF)
Note: 1 CR and 2 CR are Allen-Bradley 700S safety control relays with mechanically-linked contacts.
12
Page 13
Bulletin 700S
Safety Control Relays Overview, Continued Application Example: EN954-1 Category 3 Safety Circuit This diagram shows how to increase the current rating or number of safety outputs on Allen-Bradely Bulletin 440 safety relay by using 700S relays.
24VAC/DC, 110VAC, 230VAC K1 (AUX)
MOTION BUS
K2 (AUX)
START MOMENTARY PUSH BUTTON
L1 L2 L3
BULLETIN 700S SAFETY CONTROL RELAY
STOP GUARD CLOSED
11
23 IMP
12
24 SWITCH
MOMENTARY PUSH BUTTON
INTERLOCK
A1 S13 S21
31 13 23 X1
N.C. MECHANICALLY LINKED CONTACT
MINOTAUR MSR9T
K2
IMP 23 INTERLOCK
12
24
A2 S14 S22
SWITCH STOP
E-STOP LATCHING E-STOP BUTTON
32 14 24 X2 AUXILIARY CIRCUIT (ALARM OR INDICATION)
11
K1
FUSES
K1
K2
BULLETIN 700S SAFETY COROL RELAY
13
Page 14
Bulletin 700S
Safety Control Relays Overview, Continued Safety Relay Circuit With 5 Safety Outputs Using 700S-CF Safety Control Relays • Circuit complies with EN 954 categories 1, 2, 3 • Use for E-stop control. E-stop will work properly if any one fault occurs (a fault could be one welded contact or one undesired open connection such as a loose wire). • Prevents restart of the 5 safety outputs if there is a single fault anywhere in the system. • High output switching capability and long contact life. • Provides greater user flexibility for the number of N.O. and N.C. contacts. Use (3) 700S-CF relays and this diagram to construct the circuit.
Basic Circuit (1) Output Circuit (3 Relays, 9 Terminal Blocks)
13
14
13
14
33
34
A1
2 4 5 7 8 9 10 11 ➊ 700S-CF 620* C
A2
700-Z Included in Factory Wired Units
21
22
21
22
A1
A2
1 3 5 7 8 9 10 11 ➊ 700S-CF 350* C
61
62
43
44
A1
A2
4 6 7 8 9 10 11 700S-CF 620* C
13
14
33
34
21
22
43
44
51
52
53
54
61
62
73
74
71
72
83
84
81
82
33
LOAD 1
34
(5) Output Circuit (3 Relays, 17 Terminal Blocks) 14
15
18
16
19
22
53
54
63
64
73
74
21
24
27
25
28
➊ Numbers shown are the line numbers where the contacts for this relay appear.
14
44
20
23
26
17
43
29
LOAD 2
LOAD 3
LOAD 4 LOAD 5
➊
Page 15
Bulletin 700S
Safety Control Relays Overview, Continued Safety Relay Circuit With 8 Safety Outputs Using 700S-P Safety Control Relays
700-Z 700-ZP Included in Factory Wired Units
(A3X)
14
15 (B1X)
(B1Y)
(B2X)
(B2Y)
(B3X)
(B3Y)
(B4X)
(B4Y)
(C1X)
(C1Y)
(C2X)
(C2Y)
(C3X)
(C3Y)
18
16 (B1Y)
(B1X)
(B2Y)
(B2X)
(B3Y)
(B3X)
(B4Y)
(B4X)
(C1Y)
(C1X)
(C2Y)
(C2X)
(C3Y)
(C3X)
19
22
17 (B1X)
(B1Y)
(B2X)
(B2Y)
(B3X)
(B3Y)
(B4X)
(B4Y)
(C1X)
(C1Y)
(C2X)
(C2Y)
(C3X)
(C3Y)
20
23
26
LOAD 1
(A3Y)
21
24
27
25
28
29
LOAD 2
LOAD 3
LOAD 4 LOAD 5
. 30
31
34
32
35
38
33
36
39
37
40
41
LOAD 6
LOAD 7
LOAD 8
15
Page 16
Safety Control Relays Solutions to Meet Your Needs
Learn more about Complete Automation Safety Control Relays from Allen-Bradley on our website: www.ab.com or call your local Allen-Bradley distributor.
Our experienced representatives will support the integration of our Relays into all phases of your operation.
Get It Now! Three ways to get more information: • View publications online at: www.ab.com/ • Order publications online at: www.theautomationbookstore.com • Contact your local Allen-Bradley distributor Rockwell Automation Technical Response Center representatives are available to support your Complete Automation solution.
www.rockwellautomation.com Corporate Headquarters Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 53202-5302 USA, Tel: (1) 414.212.5200, Fax: (1) 414.212.5201 Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444 Europe: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36-BP 3A/B, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacific: Rockwell Automation, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 Headquarters for Dodge and Reliance Electric Products Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC 29615-4617 USA, Tel: (1) 864.297.4800, Fax: (1) 864.281.2433 Europe: Rockwell Automation, Brühlstraße 22, D-74834 Elztal-Dallau, Germany, Tel: (49) 6261 9410, Fax: (49) 6261 17741 Asia Pacific: Rockwell Automation, 55 Newton Road, #11-01/02 Revenue House, Singapore 307987, Tel: (65) 351 6723, Fax: (65) 355 1733 Publication 700S-SG001A-EN-E – October 2001
Copyright © 2001 Rockwell Automation. All rights reserved. Printed in USA.