Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a spec sheet · part 10 of 27

Relay and Timer Specifications, Bulletin Number 700: General Purpose Electronic Timers and Counters, pages 89 to 98

Pages 89 to 98 of 250, from Relay and Timer Specifications, Bulletin Number 700

The original document is the PDF (17 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 700S-CFB620EJC

Page 89

Relay and Timer Specifications

General Purpose Electronic Timers and Counters Product Overview

Bulletin No.

700-FE

700-FS

700-HR52, -HRP, -HRS, -HRT, -HRV

700-HRM/-HRC

700-HRF

Type

DIN Rail Timer

DIN Rail Timer

Multifunction Timer

On-Delay Timer

Twin Timer

Features

• Only 17.5 mm wide • 5 A contact rating • Multifunction or single function • No additional socket required

• Only 22.5 mm wide • 8 A contact rating • Multifunction or single function • No additional socket required • Optional: • Star-delta timing function • True off-delay timing function • Hazardous location certification

• Dial timing relays • 5 A contact rating • Multiple programmable timing ranges • Tube base pin style terminals • Multi-voltage inputs • Timed contacts and instantaneous contacts • Transistor outputs • Single function and multifunction • 7 different operating modes

• Dial timing relays • 5 A contact rating • Multiple programmable timing ranges • Tube base pin-style terminals • Multi-voltage inputs • Timed contacts and instantaneous contacts • Transistor outputs • Single function and multifunction

• Independent ON and OFF settings • 14 time ranges • 8-pin models available • Dial timing relays • UL508

Control Outputs: Time Limit Instantaneous

1 N.O. or SPDT timed

SPDT or DPDT or 2 N.O. + 1 common

DPDT Timed, Transistor SPDT Timed/Instantaneous

DPDT Timed, Transistor SPDT Timed/Instantaneous

DPDT Timed

On-delay Off-delay One shot Operation Modes: Repeat cyclepulse Fleeting off-delay Pulse converter

11 timing modes

On-Delay Off-Delay One Shot Repeat Cycle Off Start Repeat Cycle On Start Signal On/Off-Delay On-Delay One Shot

On-Delay

Repeat Cycle Off Start Repeat Cycle On Start

Time Range

0.05 s…10 hr

0.05 s…60 hr

0.05 s…300 h

0.05 s…300 h

0.05 s…300 h

Supply Voltage

24V AC/DC 110…240V AC 24…48V AC/DC 24…240V AC

12V DC 24V…48V DC 24V…240V AC

12…48V DC 24…48V AC 100…240V AC 100…125V DC

12…48V DC 24…48V AC 100…240V AC 100…125V DC

12V DC 24V AC/DC 48…125V DC 100…240V AC

Contact Rating at 120V AC

5A

8A

5A

5A

5A

Certifications

CE, cULus

CE, cULus cURus, CE, C-Tick cURus, CE, C-Tick cURus, CE, C-Tick

Socket Cat. No(s).

DIN Rail or panel mount

DIN Rail or panel mount

700-HN100 OR 700-HN101 700-HN125 OR 700-HN126

700-HN100 700-HN125

700-HN100 700-HN125

Page

92

96

116

117

117

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

89

Page 90

Relay and Timer Specifications

Bulletin No.

700-HRY

700-HRQ

700-HNC

700-HNK

Type

Star-Delta Timer

True Off-Delay Timer

Miniature Timer

Ultra-Slim Timer

Features

• A wide star-time range (up to 120 s) • Star-delta transfer time range (up to 0.5 s) • UL Recognized

• Dial timing relays • Long power Off-delay times • 11-pin and 8-pin models are available • UL Recognized

• Four different operating modes • DIN Rail mount with socket • Pin configuration same as 700-HC relay

• Ultra-slim timing relay • Four different operating modes • Three operating voltages • DIN Rail mount with socket • Pin configuration same as 700-HK relay

Control Outputs: Time Limit Instantaneous

SPST (Star, Delta) Timed SPST - NO Instantaneous

DPDT Timed

4PDT

SPDT, DPST-NO

Operation Modes:

Star-Delta

True OFF-delay Timer True OFF-delay Timer w/reset

On-Delay One Shot Repeat Cycle Off Start Repeat Cycle On Start

On-Delay One Shot Repeat Cycle Off Start Repeat Cycle On Start

Time Range

0.5 s…120 s

0.05 s…12 min.

0.1 s…10 h

0.1 s…10 h

Supply Voltage

100…120V AC 200…240V AC

48V DC 24V AC/DC 100…240V AC 100…125V DC

12V DC 24V AC/DC 48…125V DC 100…240V AC

12V DC 24V DC 24V AC

Contact Rating at 120V AC

5A

5A

5A

5A

Certifications cURus, CE, C-Tick cURus, CE, C-Tick cURus, CSA, CE, C-Tick cURus, CE, ACA

Socket Cat. No(s).

700-HN100 700-HN125

700-HN100 OR 700-HN101 700-HN125 OR 700-HN126

700-HN103 700-HN128

700-HN121 700-HN122

Page

117

118

103

109

90

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 91

Relay and Timer Specifications

Bulletin No.

700-HT

700-HV

700-HX

Tube Base Timing Relay

Repeat-Cycle Timing Relay

Digital Timer

Pin-style terminals Single range or fixed timers Available as ON- or OFF-Delays

Pin-style terminals Single-range timer Repeat cycle

Digital timer 5 A contact rating Negative transmissive LCD display 10 functions or modes Environmentally friendly - flash memory, no battery NEMA B300 rated NEMA 4/IP66 DIN Rail or panel mount capable

DPDT

DPDT

SPDT

On-Delay Off-Delay

Repeat Cycle

Signal On-Delay 1 and 2 Signal Off-Delay One Shot Repeat Cycle Off Start Repeat Cycle On Start Signal On/Off-Delay Power On-Delay 1 and 2 Twin Timer Cumulative

Time Range

0.1 s…30 min.

0.1 s…30 min.

0.05 s…300 h

Supply Voltage

12V DC 24V DC 24V AC 120V AC 240V AC

24V DC 24V AC 120V AC 240V AC

12…24V DC 24V AC 100…240V AC

Contact Rating at 120V AC

10 A

10 A

5A

Certifications

UR, UL, CSA, CE

UR, UL, CSA, CE cURus, CE, C-Tick

Socket Cat. No(s).

700-HN100 OR 700-HN101 700-HN125 OR 700-HN126

700-HN100 700-HN125

700-HN100 700-HN125

128

133

138

Type

Features

Control Outputs: Time Limit Instantaneous

Timing Operation Modes:

Page

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

91

Page 92

Relay and Timer Specifications

700-FE Economy Timing Relay • Adjustable function and timing range timing relays • DIN Rail mounted without cost of socket • 17.5 mm wide, multi-function or single function • Available as 1 N.O. or SPDT contact output, 5 A • Timing ranges from 0.05 s…10.0 hr • Coil surge protection

Multi-Function This device offers you the flexibility of selecting one of 4 single timing functions. Operating Mode

Contact Output

Timing Range(1)

Input Voltage

Cat. No. 700-FEM1TU22

700-FEM3TU23

ON-delay, OFF-delay, One Shot, Flasher (repeat cycle starting with pulse)

1 N.O.

0.05 s…10 hr (6 settings)

24V AC/DC (2) 110…240V AC 50/60 Hz

ON-delay, OFF-delay, One Shot, Flasher (repeat cycle starting with pulse)

SPDT (1 C/O)

0.05 s…10 hr (6 settings)§

24V…48V AC/DC 24…240V AC 50/60 Hz

(1) Time ranges: 0.05 s…1 s, 0.5…10 s, 0.05…1 min, 0.5…10 min, 0.05…1 hr, 0.5…10 hr. (2) Voltage is either 24V AC/DC 50/60 Hz.

Single-Function This device offers you one specific timing function. Operating Mode

Contact Output

Timing Range(1)

Input Voltage

Cat. No.

1 N.O.

0.05 s…10 hr (6 settings)

24V AC/DC 110…240V AC 50/60 Hz(2)

700-FEA1TU22

SPDT (1 C/O)

0.05 s…10 hr (6 settings)

24V…48V AC/DC 24…240V AC 50/60 Hz

700-FEA3TU23

1 N.O.

0.05 s…10 hr (6 settings)

24V AC/DC 110…240V AC 50/60 Hz(2)

700-FEB1TU22

SPDT (1 C/O)

0.05 s…10 hr (6 settings)

24V…48V AC/DC 24…240V AC 50/60 Hz

700-FEB3TU23

1 N.O.

0.05 s…10 hr (6 settings)

24V AC/DC 110…240V AC 50/60 Hz(2)

700-FED1TU22

SPDT (1 C/O)

0.05 s…10 hr (6 settings)

24V…48V AC/DC 24…240V AC 50/60 Hz

700-FED3TU23

SPDT (1 C/O)

0.05 s…10 hr (6 settings)

24V…48V AC/DC 24…240V AC 50/60 Hz

700-FEE3TU23

1 N.O.

0.05 s…10 hr (6 settings)

24V AC/DC 110…240V AC 50/60 Hz(2)

700-FEF1TU22

SPDT (1 C/O)

0.05 s…10 hr (6 settings)

24V…48V AC/DC 24…240V AC 50/60 Hz

700-FEF3TU23

SPDT (1 C/O)

0.05 s…10 hr (6 settings)

24V…48V AC/DC 24…240V AC 50/60 Hz

700-FEL3TU23

ON-delay

OFF-delay

One Shot

Fleeting OFF-delay

Flasher (repeat cycle starting with pulse)

Pulse Converter

(1) Time ranges: 0.05 s…1 s, 0.5…10 s, 0.05…1 min, 0.5…10 min, 0.05…1 hr, 0.5…10 hr. (2) Voltage is either 24V AC 50/60 Hz or 24V DC.

Special Functions Operating Mode

Contact Output

Timing Range(1)

Input Voltage

Cat. No.

Star-Delta

2 N.O. with 1 Common

0.15 s…10 min (4 settings)

24V…48V AC/DC 24…240V AC 50/60 Hz

700-FEY2QU23

(1) Time ranges: 0.15…3 s, 0.5…10 s, 3 s…1 min, 30 s…10 min.

92

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 93

Relay and Timer Specifications

Accessories - 700-FE Relays Description

Pkg. Quantity

Cat. No.

Panel Mounting Adapter For surface mounting according to drilling plan EN 50 002

5

199-FSA

Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm

10

100-FMS

Function and Connection Diagrams - 700-FE Relays (A) On-Delay U Output

(B) Off-Delay A1/A2

15

A1/A3

A2

18

1 N.O. (SPST)

A1/A2 18 15 16 t

Output LED t

15

A1

18 16

15

A2

18

U

A1/A2

S

A1/B1 18 15 16

Output t

A1 B1 S

15

A2

18 16

LED

1 C/O (SPDT)

1 C/O (SPDT)

(D) One Shot

(F) Flasher (Repeat Cycle Starting with Pulse) A1/A2 18 15 t

15

A1

18

A2

U Output

A1/A2

A1/A2 18 15 16 t

A1

15

A2

18

A1

15

A2

18 16

18 t t t t t 15

LED

1 N.O. (SPST) U Output LED

A1 B1 S

1 N.O. (SPST)

A2

U Output LED

A1/B1 18 15

S

LED

U Output LED

A1/A2

U

18 15 t

1 N.O. (SPST) 15

A1

U Output

A2

18 16 t t t t

A1/A2 18 t 1516

LED

1 C/O (SPDT) 1 C/O (SPDT) (E) Fleeting Off-Delay

(L) Pulse Converter 1)

A1/A2 B1

1)

S A1

15

B1 t LED

A2

18 16

1 C/O (SPDT)

U S Output LED

A1/A2 t t

A1/B1 18 15 16

A1 B1

A2

S

15

18 16

(Y) Star-Delta Timing Relay A1/A2

U t

∆ LED

A1

17

A2

18

17/18 17/28 tu = 50...65 ms

28

∆

Bi-color light-emitting diode: 1 C/O (SPDT) or 1 N.O. Contact Timers LED U = green: Supply voltage available. LED Relay = red: Output is energized.

Single Color light-emitting diode: 2 N.O. with Common ON = green OFF = red

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

93

Page 94

Relay and Timer Specifications

Specifications - 700-FE Relays(1) Attribute

700-FE 1 N.O.

SPDT

Setting Accuracy

±5% of full scale

Repeatability

±1% of setting (typical) By voltage: ±0.01%/%ΔU By temperature: ±0.25%/°C

Tolerance

By voltage: ±0.001%/%ΔU By temperature: ±0.025%/°C

Supply (1) and 110…240V AC, 50/60 Hz

Supply Voltage

24…48V DC and 24…240V AC, 50/60 Hz

24V AC/DC AC

–15%/+10%

DC

–15%/+20%

Voltage Tolerance Power Consumption

0.5 W at 24V DC, 5VA at 240V AC

Time Energized

100%

Reset Time

100 ms

Cable Length (Supply Voltage Control)

Max. 250 m (750 feet) Pulse Control (B1) ≥ 250 ms

Impulse Duration

≥ 50 ms (AC), ≥ 30 ms (DC)

Input Voltage supply voltage range

Input Current

1 mA

Cable Length

Max. 250 m without parallel load between B1 and A2 Max. 50 m with load (< 3 kΩ between B1 and A2 Outputs

Contact Type Dielectric Withstand Voltage

Switching Capacity

1 N.O. contact

1 Form C – SPDT contact

Contact-to-coil

4000V

Power

1250VA

According to IEC 9475-1 According to UL 508

Short circuit Resistance

AC-1

5 A /250V AC (resistive load)

AC-14

1 A/250V AC (inductive load)

DC-13

1 A/24V DC (inductive load) NEMA D300 - 1 A/300V AC 6 A gL (Fast Blow Fuse)

Mechanical

20 million operations

Electrical

0.4 million at 1 A/250V AC, resistive 0.4 million at 0.5 A/250V AC, cos φ = 0.4 0.4 million at 1 A/24V DC, resistive

Life

State Indicator

1 bicolor light-emitting diode (Supply; Relay)

Certifications cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked

Standards

EN/IEC 60947-1, EN/IEC 60947-5-1, UL 508, CSA 22.2 No. 14

Insulation Characteristics

2 kV AC/50 Hz test voltage according to VDE 0435 and 4 kV 1.2/50 μs surge voltage according to IEC 60947-1 between all inputs and outputs

EMC/Interference Immunity

The following requirements are fulfilled: Surge capacity of the supply voltage according to IEC 61000-4-5: Level 3 Burst according to IEC 61000-4-4: Level 3 ESD discharge according to IEC 61000-4-2: Level 3

EMC / Emission electromagnetic fields according to EN 55 022: Class B

(1) Time Characteristics (according to VDE 0435, part 2021)

94

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 95

Relay and Timer Specifications

Attribute

700-FE

Safe Isolation according to VDE 0106 T 101

Climatic Withstand

56 cycles (24 hr) at 25…40 °C and 95% relative humidity according to IEC 60068-2-30

Vibration Resistance

4 g in three axes at 10…500 Hz, test FC according to IEC 60068-2-6

Shock Resistance

50 g according to IEC 68-2-27 Enclosure: IP 40 Terminal: IP 20

Protection Class IEC 60947-1 Weight Certifications

60 g

60 g cULus, CE Certified cULus, Germanischer Lloyd, CE Certified Open: –25…+60 °C Enclosed: –25…+45 °C Storage: –40…+85 °C

Ambient Temperature

Connections

Screw terminal M3 for Pozidriv No.1, Philips, and slotted screws No.2. suitable for power screwdriver. Rated tightening torque 8.8 lb.-in. (max. 1.0 Nm) For terminal cross-sections of 1 x 0.5 mm2…2 x 1.5 mm2 (solid) or 2 x 1.5 mm2 (stranded with sleeve), #20…14 AWG. Finger protection according to EN 50274

Mounting

For surface mounting in any position; snap-on mounting on 35 mm DIN Rail or by adapter and two screws (M4 type)

Disposal

Synthetic materials without dioxin according to EC/EFTA-Notification No. 93/0141/D electrical contacts are AgCdO

(1) Voltage is either 24V DC or AC 50/60 Hz.

Dimensions - 700-FE Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.

80.0 (3-5/32)

13 (0.51)

22.5 (0.89)

43.0 (1-11/16)

45.0 (1-25/32)

75.0 (2.95)

4.3 (0.17)

35.0 (1.38)58.0 (2.28) 17 12 (0.67) (0.47)

66.0 (2-9/16) 70.0 (2-49/64)

17.5 (11/16)

2.0 (0.08)

4.3 (0.17) 9.0 (0.35)

Cat. No. 700-FE…

5.5 (0.22) Cat. No. 199-FSA…

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

95

Page 96

Relay and Timer Specifications

700-FS High Performance Timing Relay • Adjustable function and timing range timing relays • DIN Rail mounted without cost of socket • 22.5 mm wide multi-function or single functions • Available as SPDT or DPDT contact output, 8 A • Timing Ranges From 0.05 s…60 hr • Coil surge protection • Hazardous location version available

Catalog Number Explanation - 700-FS Relays 700

– a a Bulletin Number b -

FS

H

3

U b c d e c Operating Mode

Type of Relay

700

FS

A–On-delay B–Off-delay C–On- and off-delay D–One shot E–Fleeting off-delay F–Flasher (repeat cycle starts with pulse) G–Flasher (repeat cycle starts with pause) I–On-delay pulse generator J–On-delay (pulse controlled) K–One shot/watch dog (pulse controlled) L–Pulse converter

–

U23 f d Contact Output e Timing Range

3–One changeover contact (SPDT)1 C/O

A–0.05…1 s B–0.15…3 s C–0.5…10 s D–1.5…30 s E–0.05…1 min F–0.15…3 min G–0.5…10 min H–1.5…30 min I–0.05…1 hr J–0.15…3 hr K–0.5…10 hr L–3.0…60 hr U–0.05 s…60 hr (1)

f Input Voltage

Z12–12V DC U23–24…48V DC | 24…240V AC 50/60 Hz

(1) Valid for functions "A" and "B" only.

Single Function (With 2PDT 2 C/O contacts) Timing Range(1)

Input Voltage

Cat. No.

(DPDT) 2 C/O

12V DC

700-FSA4UZ12

(DPDT) 2 C/O

24…48V DC 24…240V AC, 50/60 Hz

700-FSA4UU23

12V DC

700-FSB4UZ12

24…48V DC 24…240V AC, 50/60 Hz

700-FSB4UU23

Operating Mode

Contact Output

On-delay On-delay Off-delay

(DPDT) 2 C/O

Off-delay

(DPDT) 2 C/O

0.05 s…60 hr

(1) The time range of "0.05 s…60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs.

Single Function With Hazardous Location Certification(1) (With SPDT 1 C/O contacts) Operating Mode

Contact Output

One Shot / Watch Dog (Pulse Controlled)

(SPDT) 1 C/O

96

Timing Range

Input Voltage

Cat. No.

0.05 s…1 s

24…48V DC 24…240V AC 50/60 Hz

700-FSK3AU23-EX

0.5 s…10 s

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

700-FSK3CU23-EX

Page 97

Relay and Timer Specifications

Multi-Function This device allows the flexibility of selecting one of 8 single timing functions. Operating Mode

Contact Output

Multi-function timing relays 8 Single-functions: A, B, C, D, E, F, I, and L ON and OFF function additional (for installation and maintenance) note: See connection diagrams for further description.

Timing Range

Input Voltage

Cat. No.

(SPDT) 1 C/O

12V DC

700-FSM3UZ12

(SPDT) 1 C/O

24…48V DC 24…240V AC 50/60 Hz

700-FSM3UU23

12V DC

700-FSM4UZ12

24…48V DC 24…240V AC 50/60 Hz

700-FSM4UU23

0.05 s…60 hr

(DPDT) 2 C/O (DPDT) 2 C/O

Multi-Function With Hazardous Location Certification (1) This device allows the flexibility of selecting one of 8 single timing functions. Operating Mode

Contact Output

M Multi-function timing relays 8 Single-functions: A, B, C, D, E, F, I, and L ON and OFF function additional (for installation and maintenance) Note: See connection diagrams for further description.

(SPDT) 1 C/O

Timing Range(1)

Input Voltage

0.05 s…60 h

24…48V DC 24…240V AC 50/60 Hz

Cat. No. 700-FSM3UU23-EX

(DPDT) 2 C/O

700-FSM4UU23-EX

(1) The time range of "0.05 s…60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs.

Special Function Operating Mode

Contact Output

Input Voltage

Cat. No.

12V DC

700-FSH3UZ12

24…48V DC 24…240V AC 50/60 Hz

700-FSH3UU23

12V DC

700-FSH3VZ12

24…48V DC 24…240V AC, 50/60 Hz

700-FSH3VU23

0.15 s…10 min(3)

24…240V DC 24…240V AC 50/60 Hz

700-FSQ3QU18

0.5 s…10 s

24…48V DC

700-FSY2CU23

Timing Range

0.05 s…60 hr Flasher (repeat cycle starting with pulse or pause)

(2)

(SPDT) 1 C/O 2 x 0.05 s…60 hr (2 ranges)

OFF-delay without supply voltages (True OFF-delay)(1)

(SPDT) 1 C/O (DPDT) 2 C/O

700-FSY2DU23

1.5…30 s Star-Delta

2 N.O. + 1 Common

0.05 s…1 min 0.15…3 min

700-FSQ4QU18

24…240V AC 50/60 Hz

0.5…10 min

700-FSY2EU23 700-FSY2FU23 700-FSY2GU23

(1) Due to shock during shipment, the state of the contacts should be verified before initial use. Minimum power on time is 800 msec (2) The time range of "0.05 s…60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs. (3) This time range is selectable in four smaller ranges: 0.15 s…2.5 s, 0.5 s…10 s, 4 s…80 s, 30 s…10 min.

(1)Temp. Code T4A 2A 32VDC MAX.: II 3 G, EEx nL IIC T4 DEMKO 04 ATEX 0404974X 2A 32VDC MAX. Ta 70 °C Ind. Cont. Eq. for Hazardous Location Listed 87SL Class 1, Div. 2, Groups A,B,C,D Class 1, Zn 2, Group IIC Subject devices are to be installed in an ATEX Certified IP54 (as defined in IEC 60529) enclosure and accessible only by the use of a tool.

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

97

Page 98

Relay and Timer Specifications

Multi-Function Timing Relay Function and Time Range Settings - 700-FS Relays Description

SPDT Multi-function timing relays 700-FSM3U includes 10 setting functions:

DPDT

Multi-Time Setting Range 0.05 s…60 h

(A)On-Delay (B)Off-Delay (C)On- and Off-Delay (D)One shot (E)Fleeting Off-Delay (F)Flasher (repeat cycle starts with pulse) (I)On-Delay pulse generator (L)Pulse converter

(1 s) 0.05…1 s (3 s) 0.15…3 s (10 s) 0.5…10 s (1 min) 0.05…1 min (3 min) 0.15…3 min (10 min) 0.5…10 min (1 hr) 0.05…1 hr (3 hr) 0.15…3 hr (10 hr) 0.5…10 hr (60 hr) 3.…60 hr

(On)ON-Function (1) (Off)OFF-Function(1) Note: Switch ⊗ is on DPDT relays only. When switch is down, one contact is instantaneous and one is timed. When switch is up, both contacts are timed. (1) For installation and maintenance.

Accessories - 700-FS Relays Description

Pkg. Quantity

Cat. No.

Setting Knob with Scale (for time setting without tools)

10

700-FSK

Panel Mounting Adapter For surface mounting according to drilling plan EN 50 002

5

199-FSA

Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm

10

100-FMS

Marking Tag Sheet 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover

10

100-FMP

Transparent Cover To be used with marking tag sheets

100

100-FMC

Marking Tag Adapters To be used with marking tag: System 1492 W

100

(1)

100-FMA2

(1) Cat. No. 100-FMA2 is only a marking tag carrier. Please refer to the Terminal Block Accessories section, Marking Solutions of this publication for appropriate marker cards to be used with this carrier.

IMPORTANT

98

Versatile Mounting: The 700-FS timing relay can be panel or DIN rail mounted. For best long-term performance, allow at least 5 mm (0.2 in.) of space on each side of the relay for proper ventilation.

Rockwell Automation Publication 700-TD552C-EN-P - October 2018